메뉴 건너뛰기




Volumn 17, Issue 12, 2010, Pages 1550-1559

Detection of Pulmonary Embolism: Comparison Between Dual Energy CT and MR Angiography in a Rabbit Model

Author keywords

Angiography; Dual energy; Magnetic resonance imaging; Pulmonary embolism; X ray computed tomography

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; ARTIFICIAL EMBOLISM; BLOOD FLOW; CLINICAL EVALUATION; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; FEMORAL VEIN; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HISTOPATHOLOGY; INTERMETHOD COMPARISON; LUNG EMBOLISM; MAGNETIC RESONANCE ANGIOGRAPHY; NONHUMAN; PRIORITY JOURNAL; RADIOLOGIST; SENSITIVITY AND SPECIFICITY;

EID: 78149394060     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2010.09.004     Document Type: Article
Times cited : (14)

References (27)
  • 2
    • 40449118680 scopus 로고    scopus 로고
    • Acute pulmonary embolism
    • Tapson V.F. Acute pulmonary embolism. N Engl J Med 2008, 358:1037-1052.
    • (2008) N Engl J Med , vol.358 , pp. 1037-1052
    • Tapson, V.F.1
  • 3
    • 35349026173 scopus 로고    scopus 로고
    • Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society
    • Remy-Jardin M., Pistolesi M., Goodman L.R., et al. Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology 2007, 245:315-329.
    • (2007) Radiology , vol.245 , pp. 315-329
    • Remy-Jardin, M.1    Pistolesi, M.2    Goodman, L.R.3
  • 4
    • 34248673159 scopus 로고    scopus 로고
    • Material differentiation by dual energy CT: initial experience
    • Johnson T.R., Krauss B., Sedlmair M., et al. Material differentiation by dual energy CT: initial experience. Eur Radiol 2007, 17:1510-1517.
    • (2007) Eur Radiol , vol.17 , pp. 1510-1517
    • Johnson, T.R.1    Krauss, B.2    Sedlmair, M.3
  • 6
    • 67650075304 scopus 로고    scopus 로고
    • Pulmonary embolism detection with dual-energy CT: experimental study of dual-source CT in rabbits
    • Zhang L.J., Zhao Y.E., Wu S.Y., et al. Pulmonary embolism detection with dual-energy CT: experimental study of dual-source CT in rabbits. Radiology 2009, 252:61-70.
    • (2009) Radiology , vol.252 , pp. 61-70
    • Zhang, L.J.1    Zhao, Y.E.2    Wu, S.Y.3
  • 7
    • 71449105418 scopus 로고    scopus 로고
    • Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits
    • Zhang L.J., Chai X., Wu S.Y., et al. Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits. Eur Radiol 2009, 19:1844-1854.
    • (2009) Eur Radiol , vol.19 , pp. 1844-1854
    • Zhang, L.J.1    Chai, X.2    Wu, S.Y.3
  • 8
    • 78149382051 scopus 로고    scopus 로고
    • Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution. Eur J Radiol. In press.
    • Ferda J, Ferdová E, Mírka H, et al. Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution. Eur J Radiol. In press.
    • Ferda, J.1    Ferdová, E.2    Mírka, H.3
  • 9
    • 70350003930 scopus 로고    scopus 로고
    • Detection of pulmonary embolism using dual-energy computed tomography and correlation with cardiovascular measurements: a preliminary study
    • Zhang L.J., Yang G.F., Zhao Y.E., et al. Detection of pulmonary embolism using dual-energy computed tomography and correlation with cardiovascular measurements: a preliminary study. Acta Radiol 2009, 50:892-901.
    • (2009) Acta Radiol , vol.50 , pp. 892-901
    • Zhang, L.J.1    Yang, G.F.2    Zhao, Y.E.3
  • 10
    • 67650306387 scopus 로고    scopus 로고
    • Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma
    • Thieme S.F., Johnson T.R., Lee C., et al. Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma. AJR Am J Roentgenol 2009, 193:144-149.
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 144-149
    • Thieme, S.F.1    Johnson, T.R.2    Lee, C.3
  • 11
    • 67049158054 scopus 로고    scopus 로고
    • Dual-energy CT pulmonary angiography: a new horizon in the imaging of acute pulmonary thromboembolism
    • Hoey E.T., Gopalan D., Screaton N.J. Dual-energy CT pulmonary angiography: a new horizon in the imaging of acute pulmonary thromboembolism. AJR Am J Roentgenol 2009, 192:W341-W342.
    • (2009) AJR Am J Roentgenol , vol.192
    • Hoey, E.T.1    Gopalan, D.2    Screaton, N.J.3
  • 12
    • 60949113925 scopus 로고    scopus 로고
    • Dual-energy CT pulmonary angiography: a novel technique for assessing acute and chronic pulmonary thromboembolism
    • Hoey E.T., Gopalan D., Ganesh V., et al. Dual-energy CT pulmonary angiography: a novel technique for assessing acute and chronic pulmonary thromboembolism. Clin Radiol 2009, 64:414-419.
    • (2009) Clin Radiol , vol.64 , pp. 414-419
    • Hoey, E.T.1    Gopalan, D.2    Ganesh, V.3
  • 13
    • 53849098569 scopus 로고    scopus 로고
    • Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results
    • Fink C., Johnson T.R., Michaely H.J., et al. Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results. Rofo 2008, 180:879-883.
    • (2008) Rofo , vol.180 , pp. 879-883
    • Fink, C.1    Johnson, T.R.2    Michaely, H.J.3
  • 14
    • 55349095807 scopus 로고    scopus 로고
    • Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients
    • Pontana F., Faivre J.B., Remy-Jardin M., et al. Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol 2008, 15:1494-1504.
    • (2008) Acad Radiol , vol.15 , pp. 1494-1504
    • Pontana, F.1    Faivre, J.B.2    Remy-Jardin, M.3
  • 15
    • 77749277564 scopus 로고    scopus 로고
    • Dual-energy CT for assessment of the severity of acute pulmonary embolism: pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio
    • Chae E.J., Seo J.B., Jang Y.M., et al. Dual-energy CT for assessment of the severity of acute pulmonary embolism: pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio. AJR Am J Roentgenol 2010, 194:604-610.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 604-610
    • Chae, E.J.1    Seo, J.B.2    Jang, Y.M.3
  • 16
    • 0030939253 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with magnetic resonance angiography
    • Meaney J.F., Weg J.G., Chenevert T.L., et al. Diagnosis of pulmonary embolism with magnetic resonance angiography. N Engl J Med 1997, 336:1422-1427.
    • (1997) N Engl J Med , vol.336 , pp. 1422-1427
    • Meaney, J.F.1    Weg, J.G.2    Chenevert, T.L.3
  • 17
    • 0037062132 scopus 로고    scopus 로고
    • Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study
    • Oudkerk M., van Beek E.J., Wielopolski P., et al. Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study. Lancet 2002, 359:1643-1647.
    • (2002) Lancet , vol.359 , pp. 1643-1647
    • Oudkerk, M.1    van Beek, E.J.2    Wielopolski, P.3
  • 18
    • 2942709854 scopus 로고    scopus 로고
    • MR angiography with sensitivity encoding (SENSE) for suspected pulmonary embolism: comparison with MDCT and ventilation-perfusion scintigraphy
    • Ohno Y., Higashino T., Takenaka D., et al. MR angiography with sensitivity encoding (SENSE) for suspected pulmonary embolism: comparison with MDCT and ventilation-perfusion scintigraphy. AJR Am J Roentgenol 2004, 183:91-98.
    • (2004) AJR Am J Roentgenol , vol.183 , pp. 91-98
    • Ohno, Y.1    Higashino, T.2    Takenaka, D.3
  • 19
    • 71049129449 scopus 로고    scopus 로고
    • Time-resolved and high-resolution MRA in a rabbit model of pulmonary embolism at 7 T: preliminary results
    • Mata J.F., Bozlar U., Mugler J.P., et al. Time-resolved and high-resolution MRA in a rabbit model of pulmonary embolism at 7 T: preliminary results. Magn Reson Imaging 2010, 28:139-145.
    • (2010) Magn Reson Imaging , vol.28 , pp. 139-145
    • Mata, J.F.1    Bozlar, U.2    Mugler, J.P.3
  • 20
    • 3242808247 scopus 로고    scopus 로고
    • 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent
    • Fink C., Ley S., Puderbach M., Plathow C., et al. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent. Eur Radiol 2004, 14:1291-1296.
    • (2004) Eur Radiol , vol.14 , pp. 1291-1296
    • Fink, C.1    Ley, S.2    Puderbach, M.3    Plathow, C.4
  • 21
    • 0032927120 scopus 로고    scopus 로고
    • Acute pulmonary embolism: diagnosis with MR angiography
    • Gupta A., Frazer C.K., Ferguson J.M., et al. Acute pulmonary embolism: diagnosis with MR angiography. Radiology 1999, 210:353-359.
    • (1999) Radiology , vol.210 , pp. 353-359
    • Gupta, A.1    Frazer, C.K.2    Ferguson, J.M.3
  • 22
    • 33846217773 scopus 로고    scopus 로고
    • Acute pulmonary embolism to the subsegmental level: diagnostic accuracy of three MRI techniques compared with 16-MDCT
    • Kluge A., Luboldt W., Bachmann G. Acute pulmonary embolism to the subsegmental level: diagnostic accuracy of three MRI techniques compared with 16-MDCT. AJR Am J Roentgenol 2006, 187:W7-W14.
    • (2006) AJR Am J Roentgenol , vol.187
    • Kluge, A.1    Luboldt, W.2    Bachmann, G.3
  • 23
    • 33646055466 scopus 로고    scopus 로고
    • Gadolinium-enhanced pulmonary magnetic resonance angiography in the diagnosis of acute pulmonary embolism: a prospective study on 48 patients
    • Pleszewski B., Chartrand-Lefebvre C., Qanadli S.D., et al. Gadolinium-enhanced pulmonary magnetic resonance angiography in the diagnosis of acute pulmonary embolism: a prospective study on 48 patients. Clin Imaging 2006, 30:166-172.
    • (2006) Clin Imaging , vol.30 , pp. 166-172
    • Pleszewski, B.1    Chartrand-Lefebvre, C.2    Qanadli, S.D.3
  • 24
    • 77951230096 scopus 로고    scopus 로고
    • PIOPED III (Prospective Investigation of Pulmonary Embolism Diagnosis III) Investigators. Gadolinium-enhanced magnetic resonance angiography for pulmonary embolism: a multicenter prospective study (PIOPED III)
    • Stein P.D., Chenevert T.L., Fowler S.E., et al. PIOPED III (Prospective Investigation of Pulmonary Embolism Diagnosis III) Investigators. Gadolinium-enhanced magnetic resonance angiography for pulmonary embolism: a multicenter prospective study (PIOPED III). Ann Intern Med 2010, 152:434-443.
    • (2010) Ann Intern Med , vol.152 , pp. 434-443
    • Stein, P.D.1    Chenevert, T.L.2    Fowler, S.E.3
  • 25
    • 77951244822 scopus 로고    scopus 로고
    • Why can't magnetic resonance imaging reliably diagnose pulmonary embolism?
    • Davidson B.L., Lacrampe M.J. Why can't magnetic resonance imaging reliably diagnose pulmonary embolism?. Ann Intern Med 2010, 152:467-468.
    • (2010) Ann Intern Med , vol.152 , pp. 467-468
    • Davidson, B.L.1    Lacrampe, M.J.2
  • 26
    • 34548512667 scopus 로고    scopus 로고
    • Magnetic resonance imaging of acute pulmonary embolism
    • Fink C., Ley S., Schoenberg S.O., et al. Magnetic resonance imaging of acute pulmonary embolism. Eur Radiol 2007, 17:2546-2553.
    • (2007) Eur Radiol , vol.17 , pp. 2546-2553
    • Fink, C.1    Ley, S.2    Schoenberg, S.O.3
  • 27
    • 70349170220 scopus 로고    scopus 로고
    • MR diagnosis of a pulmonary embolism: comparison of P792 and Gd-DOTA for first-pass perfusion MRI and contrast-enhanced 3D MRA in a rabbit model
    • Keilholz S.D., Bozlar U., Fujiwara N., et al. MR diagnosis of a pulmonary embolism: comparison of P792 and Gd-DOTA for first-pass perfusion MRI and contrast-enhanced 3D MRA in a rabbit model. Korean J Radiol 2009, 10:447-454.
    • (2009) Korean J Radiol , vol.10 , pp. 447-454
    • Keilholz, S.D.1    Bozlar, U.2    Fujiwara, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.