메뉴 건너뛰기




Volumn 14, Issue 7, 2004, Pages 1291-1296

3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent

Author keywords

Contrast media; Lung; Magnetic resonance; Perfusion; Pulmonary embolism

Indexed keywords

GADOLINIUM PENTETATE; GADOMER 17;

EID: 3242808247     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-004-2282-8     Document Type: Article
Times cited : (31)

References (21)
  • 1
    • 0037452502 scopus 로고    scopus 로고
    • Single-detector helical computed tomography as the primary diagnostic test in suspected pulmonary embolism: A multicenter clinical management study of 510 patients
    • van Strijen MJ, de Monye W, Schiereck J, Kieft GJ, Prins MH, Huisman MV, Pattynama PM (2003) Single-detector helical computed tomography as the primary diagnostic test in suspected pulmonary embolism: a multicenter clinical management study of 510 patients. Ann Int Med 138:307-314
    • (2003) Ann. Int. Med. , vol.138 , pp. 307-314
    • van Strijen, M.J.1    de Monye, W.2    Schiereck, J.3    Kieft, G.J.4    Prins, M.H.5    Huisman, M.V.6    Pattynama, P.M.7
  • 4
    • 0037062132 scopus 로고    scopus 로고
    • Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: A prospective study
    • Oudkerk M, van Beek EJ, Wielopolski P, van Ooijen PM, Brouwers-Kuyper EM, Bongaerts AH, Berghout A (2002) Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study. Lancet 359:1643-1647
    • (2002) Lancet , vol.359 , pp. 1643-1647
    • Oudkerk, M.1    van Beek, E.J.2    Wielopolski, P.3    van Ooijen, P.M.4    Brouwers-Kuyper, E.M.5    Bongaerts, A.H.6    Berghout, A.7
  • 6
    • 0029760132 scopus 로고    scopus 로고
    • Pulmonary perfusion: Qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH
    • Hatabu H, Gaa J, Kim D, Li W, Prasad PV, Edelman RR (1996) Pulmonary perfusion: qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH. Magn Reson Med 36:503-508
    • (1996) Magn. Reson. Med. , vol.36 , pp. 503-508
    • Hatabu, H.1    Gaa, J.2    Kim, D.3    Li, W.4    Prasad, P.V.5    Edelman, R.R.6
  • 7
    • 0032613270 scopus 로고    scopus 로고
    • Evolution of pulmonary perfusion defects demonstrated with contrast-enhanced dynamic MR perfusion imaging
    • Howarth NR, Beziat C, Berthezene Y (1999) Evolution of pulmonary perfusion defects demonstrated with contrast-enhanced dynamic MR perfusion imaging. Eur Radiol 9:1574-1576
    • (1999) Eur. Radiol. , vol.9 , pp. 1574-1576
    • Howarth, N.R.1    Beziat, C.2    Berthezene, Y.3
  • 8
    • 0038383241 scopus 로고    scopus 로고
    • Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion - Initial results
    • Fink C, Bock M, Puderbach M, Schmahl A, Delorme S (2003) Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion - initial results. Invest Radiol 38:482-488
    • (2003) Invest. Radiol. , vol.38 , pp. 482-488
    • Fink, C.1    Bock, M.2    Puderbach, M.3    Schmahl, A.4    Delorme, S.5
  • 10
    • 0036199278 scopus 로고    scopus 로고
    • Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilation-perfusion scintigraphy: An intra-modality and inter-modality agreement study
    • Amundsen T, Torheim G, Kvistad KA, Waage A, Bjermer L, Nordlid KK, Johnsen H, Asberg A, Haraldseth O (2002) Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilation-perfusion scintigraphy: an intra-modality and inter-modality agreement study. J Magn Reson Imaging 15:386-394
    • (2002) J. Magn. Reson. Imaging , vol.15 , pp. 386-394
    • Amundsen, T.1    Torheim, G.2    Kvistad, K.A.3    Waage, A.4    Bjermer, L.5    Nordlid, K.K.6    Johnsen, H.7    Asberg, A.8    Haraldseth, O.9
  • 12
    • 0036514601 scopus 로고    scopus 로고
    • Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigs
    • Abolmaali ND, Hietschold V, Appold S, Ebert W, Vogl TJ (2002) Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigs. Eur Radiol 12:692-697
    • (2002) Eur. Radiol. , vol.12 , pp. 692-697
    • Abolmaali, N.D.1    Hietschold, V.2    Appold, S.3    Ebert, W.4    Vogl, T.J.5
  • 13
    • 0028348575 scopus 로고
    • Contrast-enhanced thin slice ultrafast computed tomography for the detection of small pulmonary emboli. Studies using autologous emboli in the pig
    • Stanford W, Reiners TJ, Thompson BH, Landas SK, Galvin JR (1994) Contrast-enhanced thin slice ultrafast computed tomography for the detection of small pulmonary emboli. Studies using autologous emboli in the pig. Invest Radiol 29:184-187
    • (1994) Invest. Radiol. , vol.29 , pp. 184-187
    • Stanford, W.1    Reiners, T.J.2    Thompson, B.H.3    Landas, S.K.4    Galvin, J.R.5
  • 14
    • 0034981548 scopus 로고    scopus 로고
    • Pharmacokinetics of Gadomer-17, a new dendritic magnetic resonance contrast agent
    • Misselwitz B, Schmitt-Willich H, Ebert W, Frenzel T, Weinmann HJ (2001) Pharmacokinetics of Gadomer-17, a new dendritic magnetic resonance contrast agent. MAGMA 12:128-134
    • (2001) MAGMA , vol.12 , pp. 128-134
    • Misselwitz, B.1    Schmitt-Willich, H.2    Ebert, W.3    Frenzel, T.4    Weinmann, H.J.5
  • 16
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ (1997) Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 38:591-603
    • (1997) Magn. Reson. Med. , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 18
    • 0344842109 scopus 로고    scopus 로고
    • Parallel acquisition techniques for cardiac cine MRA: Comparison of image quality
    • 2002
    • Hunold P, Maderwald S, Ladd ME et al (2002) Parallel acquisition techniques for cardiac cine MRA: comparison of image quality. Proc ISMRM 2002:1664
    • (2002) Proc. ISMRM , pp. 1664
    • Hunold, P.1    Maderwald, S.2    Ladd, M.E.3
  • 19
    • 0026689081 scopus 로고
    • Magnetic resonance imaging detection of an experimental pulmonary perfusion deficit using a macromolecular contrast agent. Polylysine-gadolinium-DTPA40
    • Berthezene Y, Vexler V, Price DC, Wisner-Dupon J, Moseley ME, Aicher KP, Brasch RC (1992) Magnetic resonance imaging detection of an experimental pulmonary perfusion deficit using a macromolecular contrast agent. Polylysine-gadolinium-DTPA40. Invest Radiol 27:346-351
    • (1992) Invest. Radiol. , vol.27 , pp. 346-351
    • Berthezene, Y.1    Vexler, V.2    Price, D.C.3    Wisner-Dupon, J.4    Moseley, M.E.5    Aicher, K.P.6    Brasch, R.C.7
  • 21
    • 0036690272 scopus 로고    scopus 로고
    • Assessment of lung ventilation by MR imaging: Current status and future perspectives
    • Kauczor HU, Hanke A, Van Beek EJ (2002) Assessment of lung ventilation by MR imaging: current status and future perspectives. Eur Radiol 12:1962-1970
    • (2002) Eur. Radiol. , vol.12 , pp. 1962-1970
    • Kauczor, H.U.1    Hanke, A.2    Van Beek, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.