메뉴 건너뛰기




Volumn 56, Issue 5, 2010, Pages 488-501

A review of indoor air pollution and health problems from the viewpoint of environmental hygiene: Focusing on the studies of indoor air environment in japan compared to those of foreign countries

Author keywords

Health; Indoor air quality; Multi chemical sensitivity; Sick building syndrome; Sick house syndrome; Volatile organic compounds

Indexed keywords

1,4 DICHLOROBENZENE; 2 ETHYLHEXANOL; ACETALDEHYDE; CHLORPYRIFOS; DIAGINON; ETHYLBENZENE; FENOBUCARB; FORMALDEHYDE; HEAVY METAL; LEAD; NANOMATERIAL; NANOPARTICLE; PHTHALIC ACID BIS(2 ETHYLHEXYL) ESTER; PHTHALIC ACID DIBUTYL ESTER; RADON; STYRENE; TETRADECANE; TITANIUM DIOXIDE; TOLUENE; UNCLASSIFIED DRUG; VOLATILE ORGANIC COMPOUND; XYLENE;

EID: 78049284853     PISSN: 13449702     EISSN: 13475207     Source Type: Journal    
DOI: 10.1248/jhs.56.488     Document Type: Review
Times cited : (27)

References (152)
  • 1
    • 13444249636 scopus 로고    scopus 로고
    • Indoor air quality and human health: Truth vs mass hysteria
    • Chang, C. and Gershwin, M. E. (2004) Indoor air quality and human health: truth vs mass hysteria. Clin. Rev. Allergy Immunol., 27, 219-239.
    • (2004) Clin Rev. Allergy Immunol , vol.27 , pp. 219-239
    • Chang, C.1    Gershwin, M.E.2
  • 2
    • 85036733998 scopus 로고    scopus 로고
    • The Ministry of Health Labour and Welfare, The guideline value of indoor formaldehyde concentration report of chemical substances small committee, specialty section to establish standards for health residences, (cited 19 May, 2010)
    • The Ministry of Health Labour and Welfare, The guideline value of indoor formaldehyde concentration report of chemical substances small committee, specialty section to establish standards for health residences, http://www1.mhlw.go.jp/houdou/ 1206/h0629-2 13.html, (cited 19 May, 2010).
  • 3
    • 85036752665 scopus 로고    scopus 로고
    • TheMinistry of land, Infrastructure and Transport in Japan, The amendments of Building Standard Law, (cited 19 May, 2010)
    • TheMinistry of land, Infrastructure and Transport in Japan, The amendments of Building Standard Law, http://www.mlit.go.jp/jutakukentiku/build/sickhouse.html, (cited 19 May, 2010).
  • 4
    • 78049289571 scopus 로고    scopus 로고
    • Back-to-Back housing, courts, and privies: The slums of 19th century England
    • Ashton, J. R. (2006) Back-to-Back housing, courts, and privies: the slums of 19th century England. J. Epidemiol. Community Health, 60, 654.
    • (2006) J. Epidemiol. Community Health , vol.60 , pp. 654
    • Ashton, J.R.1
  • 5
    • 85036748621 scopus 로고
    • JYUKYO TO EISEI, Kouseikan
    • (in Japanese)
    • Miura, U. (1957) JYUKYO TO EISEI, Kouseikan, Tokyo, pp. 1-8 (in Japanese).
    • (1957) Tokyo , pp. 1-8
    • Miura, U.1
  • 6
    • 85036748574 scopus 로고
    • SEIKATSU NO EISEIGAKU, Roudoukagakukenkyusho
    • (in Japanese)
    • Miura, T. (1981) SEIKATSU NO EISEIGAKU, Roudoukagakukenkyusho, Tokyo, pp. 142-147 (in Japanese).
    • (1981) Tokyo , pp. 142-147
    • Miura, T.1
  • 7
    • 85036742223 scopus 로고
    • KAITEKIKANKYOU NO FOHKUROA-SIZEN TO JINKOUKANKYOU-, Roudoukagakukenkyusho
    • (in Japanese)
    • Miura, T. (1993) KAITEKIKANKYOU NO FOHKUROA-SIZEN TO JINKOUKANKYOU-, Roudoukagakukenkyusho, Tokyo, pp. 279-307 (in Japanese).
    • (1993) Tokyo , pp. 279-307
    • Miura, T.1
  • 8
    • 85036732923 scopus 로고    scopus 로고
    • SEKIYUKIKI NI ABURIDASARETA HIYOWANA NIPPON
    • The Asahi Shinbun Company (in Japanese)
    • The Asahi Shinbun Company (1999) "SEKIYUKIKI" NI ABURIDASARETA HIYOWANA NIPPON. Asahi Chronicle/Weekly the 20th Century, 31, 2-6 (in Japanese).
    • (1999) Asahi Chronicle/Weekly the 20th Century , vol.31 , pp. 2-6
  • 9
    • 85036740677 scopus 로고    scopus 로고
    • U.S. Department of State, Second Arab Oil Embargo, 1973-1974 (cited 13 February, 2010)
    • U.S. Department of State, Second Arab Oil Embargo, 1973-1974, http://www.state.gov/r/pa/ho/ time/dr/96057.htm, (cited 13 February, 2010)
  • 10
    • 0021702613 scopus 로고
    • Health policy and epidemiology: The scientific evidence for a ban of ureaformaldehyde foam insulation
    • Elinson, L. (1984) Health policy and epidemiology: The scientific evidence for a ban of ureaformaldehyde foam insulation. J. Public Health Policy, 5, 513-537.
    • (1984) J. Public Health Policy , vol.5 , pp. 513-537
    • Elinson, L.1
  • 11
    • 0021056972 scopus 로고
    • Indoor air pollutants; Exposure and Health Effects Assessments. Working Group Report, Nordlingen
    • World Health Organization
    • World Health Organization (1983) Indoor air pollutants; Exposure and Health Effects Assessments. Working Group Report, Nordlingen, Euro Reports and Studies, 78, 1-42.
    • (1983) Euro Reports and Studies , vol.78 , pp. 1-42
  • 12
    • 85036742270 scopus 로고    scopus 로고
    • Study of Indoor Air Pollution
    • (in Japanese)
    • Arashidani, K., Akiyama, Y. and Kunugita, N. (2009) Study of Indoor Air Pollution. Indoor Environ., 12, 71-86 (in Japanese).
    • (2009) Indoor Environ , vol.12 , pp. 71-86
    • Arashidani, K.1    Akiyama, Y.2    Kunugita, N.3
  • 13
    • 85036737675 scopus 로고    scopus 로고
    • Historical review on the indoor environment and health
    • (in Japanese)
    • Irie, T. (2007) Historical review on the indoor environment and health. Indoor Environ., 10, 129-135 (in Japanese).
    • (2007) Indoor Environ , vol.10 , pp. 129-135
    • Irie, T.1
  • 14
    • 85036763327 scopus 로고    scopus 로고
    • Committee on sick house syndrome, Indoor air pollution progress report No. 4, (cited 20 February, 2010)
    • Committee on sick house syndrome, Indoor air pollution progress report No. 4, http://www.nihs.go. jp/mhlw/chemical/situnai/kentoukai/rep-eng4.html, (cited 20 February, 2010)
  • 17
  • 18
    • 47649123138 scopus 로고    scopus 로고
    • Evaluating buildingrelated symptoms using the US EPA BASE study results
    • Brightman, H. S., Milton, D. K., Wypij, D., Burge, H. S. and Spengler, J. D. (2008) Evaluating buildingrelated symptoms using the US EPA BASE study results. Indoor Air, 18, 335-345.
    • (2008) Indoor Air , vol.18 , pp. 335-345
    • Brightman, H.S.1    Milton, D.K.2    Wypij, D.3    Burge, H.S.4    Spengler, J.D.5
  • 19
    • 66049113465 scopus 로고    scopus 로고
    • Residential air pollution by chemicals (HCHO, NO2, VOC and SVOC) under normal living conditions in Osaka prefecture
    • (in Japanese)
    • Yoshida, T., Matsunaga, I., Oda, H., Miyake, Y., Sasaki, S., Ohya, Y., Miyamoto, S. and Hirota, Y. (2007) Residential air pollution by chemicals (HCHO, NO2, VOC and SVOC) under normal living conditions in Osaka prefecture. Indoor Environ., 9, 83-85 (in Japanese).
    • (2007) Indoor Environ , vol.9 , pp. 83-85
    • Yoshida, T.1    Matsunaga, I.2    Oda, H.3    Miyake, Y.4    Sasaki, S.5    Ohya, Y.6    Miyamoto, S.7    Hirota, Y.8
  • 20
    • 33847790876 scopus 로고    scopus 로고
    • Survey on the symptoms of illness possibly related to chemical substances in living environments
    • (in Japanese)
    • Azuma, M., Niiya, M., Morita, Y. and Hikita, Y. (2000) Survey on the symptoms of illness possibly related to chemical substances in living environments. Indoor Environ., 3, 23-33 (in Japanese).
    • (2000) Indoor Environ , vol.3 , pp. 23-33
    • Azuma, M.1    Niiya, M.2    Morita, Y.3    Hikita, Y.4
  • 21
    • 33846515660 scopus 로고    scopus 로고
    • Trial of isolation of sick house syndrome and unclassified multiple chemical sensitivities-Definition of sick house syndrome, and symptoms
    • (in Japanese)
    • Torii, S., Hirayama, K., Akiyama, K., Ikezawa, Z., Uchino, E., Okamoto, Y., Ogura, H., Takahashi, K., Nishima, S. and Torii, S. (2006) Trial of isolation of sick house syndrome and unclassified multiple chemical sensitivities-Definition of sick house syndrome, and symptoms. Arerugi, 55, 1515-1530 (in Japanese).
    • (2006) Arerugi , vol.55 , pp. 1515-1530
    • Torii, S.1    Hirayama, K.2    Akiyama, K.3    Ikezawa, Z.4    Uchino, E.5    Okamoto, Y.6    Ogura, H.7    Takahashi, K.8    Nishima, S.9    Torii, S.10
  • 23
    • 43249110118 scopus 로고    scopus 로고
    • Psychosocial Factors that aggravate the symptoms of sick house syndrome in Japan
    • Imai, N., Imai, Y. and Kido, Y. (2008) Psychosocial Factors that aggravate the symptoms of sick house syndrome in Japan. Nurs. Health Sci., 10, 101-109.
    • (2008) Nurs. Health Sci , vol.10 , pp. 101-109
    • Imai, N.1    Imai, Y.2    Kido, Y.3
  • 24
    • 85036728214 scopus 로고    scopus 로고
    • An Opinion against Sick House Syndrome
    • 60, preface (in Japanese)
    • Aizawa, K. (2005) An Opinion against Sick House Syndrome. Jpn. J. Hyg., 60, preface (in Japanese).
    • (2005) Jpn. J. Hyg
    • Aizawa, K.1
  • 25
    • 78049232873 scopus 로고    scopus 로고
    • Questionnaire survey on multiple chemical sensitivity-like symptoms in schoolchildren (6-12 years of age)
    • (in Japanese)
    • Sugita, O., Nakagawa, I., Nigorikawa, A., Soda, K., Murooka, K. and Sakamoto, C. (2007) Questionnaire survey on multiple chemical sensitivity-like symptoms in schoolchildren (6-12 years of age). Indoor Environ., 10, 137-145 (in Japanese).
    • (2007) Indoor Environ , vol.10 , pp. 137-145
    • Sugita, O.1    Nakagawa, I.2    Nigorikawa, A.3    Soda, K.4    Murooka, K.5    Sakamoto, C.6
  • 27
    • 0032991629 scopus 로고    scopus 로고
    • Multiple Chemical Sensitivity: A 1999 Consensus
    • 1999 Consensus on Multiple Chemical Sensitivity
    • Consensus on Multiple Chemical Sensitivity (1999) Multiple Chemical Sensitivity: A 1999 Consensus. Arch. Environ. Health, 54, 147-149.
    • (1999) Arch. Environ. Health , vol.54 , pp. 147-149
  • 28
    • 0031037113 scopus 로고    scopus 로고
    • Report of a multiple chemical sensitivities (MCS) workshop: International Program on Chemical Safety (IPCS)/German Workshop on Multiple Chemical Sensitivities, Berlin, Germany, 21-23 February 1996
    • Anonymous
    • Anonymous (1997) Report of a multiple chemical sensitivities (MCS) workshop: International Program on Chemical Safety (IPCS)/German Workshop on Multiple Chemical Sensitivities, Berlin, Germany, 21-23 February 1996. Int. Arch. Occup. Environ. Health, 69, 224-226.
    • (1997) Int. Arch. Occup. Environ. Health , vol.69 , pp. 224-226
  • 29
    • 85036733884 scopus 로고    scopus 로고
    • Sikkuhausu-shoukougunn no ekigaku- saikinn no tikenn-
    • in Japanese
    • Kishi, R., Takeda, M., Kanazawa, H. and Araki, A. (2008) Sikkuhausu-shoukougunn no ekigaku- saikinn no tikenn-, Nippon Iji Shinpo, 4370, 73-76 (in Japanese).
    • (2008) Nippon Iji Shinpo , vol.4370 , pp. 73-76
    • Kishi, R.1    Takeda, M.2    Kanazawa, H.3    Araki, A.4
  • 30
    • 17844364606 scopus 로고    scopus 로고
    • Multiple Chemical Sensitivity Syndrome (MCS)-suggestions for an extension of the US MCS-case definition
    • Lacour, M., Zunder, T., Schmidtke, K., Vaith, P. and Scheidt, C. (2005) Multiple Chemical Sensitivity Syndrome (MCS)-suggestions for an extension of the US MCS-case definition. Int. J. Hyg. Environ. Health, 208, 141-151.
    • (2005) Int. J. Hyg. Environ. Health , vol.208 , pp. 141-151
    • Lacour, M.1    Zunder, T.2    Schmidtke, K.3    Vaith, P.4    Scheidt, C.5
  • 31
    • 64949095616 scopus 로고    scopus 로고
    • Diagnosis of multiple chemical sensitivity by chemical compounds exposure tests
    • in Japanese
    • Hasegawa, M., Ohtomo, M., Mizuki, M. and Akiyama, K. (2009) Diagnosis of multiple chemical sensitivity by chemical compounds exposure tests. Arerugi, 58, 112-118 (in Japanese).
    • (2009) Arerugi , vol.58 , pp. 112-118
    • Hasegawa, M.1    Ohtomo, M.2    Mizuki, M.3    Akiyama, K.4
  • 32
    • 33845185900 scopus 로고    scopus 로고
    • Multiple Chemical Sensitivities: A systematic review of provocation studies
    • Das-Munshi, J., James Rubin, G. J. and Wessely, S. (2006) Multiple Chemical Sensitivities: A systematic review of provocation studies, J. Allergy Clin. Immunol., 118, 1257-1264
    • (2006) J. Allergy Clin. Immunol , vol.118 , pp. 1257-1264
    • Das-Munshi, J.1    James Rubin, G.J.2    Wessely, S.3
  • 33
    • 77249173779 scopus 로고    scopus 로고
    • Evaluation of subjective symptoms of Japanese patients with multiple chemical sensitivity using QEESI_ c. Environ
    • Hojo, S., Sakabe, K., Ishikawa, S., Miyata, M. and Kumano, H. (2009) Evaluation of subjective symptoms of Japanese patients with multiple chemical sensitivity using QEESI_c. Environ. Health Prev. Med., 14, 267-275.
    • (2009) Health Prev. Med , vol.14 , pp. 267-275
    • Hojo, S.1    Sakabe, K.2    Ishikawa, S.3    Miyata, M.4    Kumano, H.5
  • 34
    • 0035013791 scopus 로고    scopus 로고
    • Sick building syndrome in relation to building dampness in multi-family residential building in Stockholm
    • Engvall, K., Norrby, C. and Norback, D. (2001) Sick building syndrome in relation to building dampness in multi-family residential building in Stockholm. Int. Arch. Occup. Environ. Health, 74, 270-278.
    • (2001) Int. Arch. Occup. Environ. Health , vol.74 , pp. 270-278
    • Engvall, K.1    Norrby, C.2    Norback, D.3
  • 35
    • 70349584354 scopus 로고    scopus 로고
    • Relation of dampness to sick building syndrome in Japanese public apartment houses
    • Saijo, Y., Nakagi, Y., Ito, T., Sugioka, Y., Endo, H. and Yoshida, Y. (2009) Relation of dampness to sick building syndrome in Japanese public apartment houses. Environ. Health Prev.Med., 14, 26-35.
    • (2009) Environ. Health Prev.Med , vol.14 , pp. 26-35
    • Saijo, Y.1    Nakagi, Y.2    Ito, T.3    Sugioka, Y.4    Endo, H.5    Yoshida, Y.6
  • 37
    • 69849087215 scopus 로고    scopus 로고
    • Dampness, Biological Factors and Sick House Syndrome
    • in Japanese
    • Saijo, Y., Yoshida, T. and Kishi, R. (2009) Dampness, Biological Factors and Sick House Syndrome. Jpn. J. Hyg., 64, 665-671 (in Japanese).
    • (2009) Jpn. J. Hyg , vol.64 , pp. 665-671
    • Saijo, Y.1    Yoshida, T.2    Kishi, R.3
  • 38
    • 85036747700 scopus 로고
    • Physiological and Psychological Effects of Low Humidity and Low Air Pressure Environment in Passenger Aircrafts
    • Maehara, N.,Watanabe, A. and Kurosawa, in JapaneseS
    • Maehara, N.,Watanabe, A. and Kurosawa, S. (1991) Physiological and Psychological Effects of Low Humidity and Low Air Pressure Environment in Passenger Aircrafts. J. Sci. Labour, 67, 1275-1292 (in Japanese).
    • (1991) J. Sci. Labour , vol.67 , pp. 1275-1292
  • 39
    • 0345734087 scopus 로고    scopus 로고
    • Significance of humidity and temperature on skin and upper airway symptoms
    • Reinikainen, L. M. and Jaakkola, J. J. (2003) Significance of humidity and temperature on skin and upper airway symptoms. Indoor Air, 13, 344-352.
    • (2003) Indoor Air , vol.13 , pp. 344-352
    • Reinikainen, L.M.1    Jaakkola, J.J.2
  • 40
    • 85036729233 scopus 로고    scopus 로고
    • Study on effect of building materials to regulate an indoor humidity on indoor environment and psychophysiologicconditions
    • in Japanese
    • Ogawa, H., Nakamura, M., Shibahara, K., Nishigaki, Y., Itou, K., Naruse, T., Fujimaki, G., Matsui, E., Orii, K. and Kondo, N. (2009) Study on effect of building materials to regulate an indoor humidity on indoor environment and psychophysiologicconditions. Indoor Environ., 12, 125-131 (in Japanese).
    • (2009) Indoor Environ , vol.12 , pp. 125-131
    • Ogawa, H.1    Nakamura, M.2    Shibahara, K.3    Nishigaki, Y.4    Itou, K.5    Naruse, T.6    Fujimaki, G.7    Matsui, E.8    Orii, K.9    Kondo, N.10
  • 41
    • 67749104667 scopus 로고    scopus 로고
    • Indoor thermal factors and symptoms in office workers: Findings from the US EPA BASE study
    • Mendell, M. J. and Mirer, A. G. (2009) Indoor thermal factors and symptoms in office workers: findings from the US EPA BASE study. Indoor Air, 19, 291-302.
    • (2009) Indoor Air , vol.19 , pp. 291-302
    • Mendell, M.J.1    Mirer, A.G.2
  • 43
    • 70249108418 scopus 로고    scopus 로고
    • Short-term impact of particulate matter (PM2.5) on dairy mortality among the over-75 age group in Madrid (Spain)
    • Jimenez, E., Linares, C., Rodriguez, L. F., Bleda, M. J. and Diaz, J. (2009) Short-term impact of particulate matter (PM2.5) on dairy mortality among the over-75 age group in Madrid (Spain). Sci. Total Environ., 407, 5486-5492.
    • (2009) Sci. Total Environ , vol.407 , pp. 5486-5492
    • Jimenez, E.1    Linares, C.2    Rodriguez, L.F.3    Bleda, M.J.4    Diaz, J.5
  • 44
    • 85036759471 scopus 로고    scopus 로고
    • World Health Organization, Air quality guidelines global update 2005, Particulate matter, Ozone, nitrogen dioxide and sulfur dioxide, (cited 3 July, 2010)
    • World Health Organization, Air quality guidelines global update 2005, Particulate matter, Ozone, nitrogen dioxide and sulfur dioxide, http://www.euro.who.int/ data/assets/pdf file/0005/ 78638/E90038.pdf, (cited 3 July, 2010).
  • 45
    • 85036771400 scopus 로고    scopus 로고
    • World Health Organization, WHO Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide, global update 2005, Summary of risk assessment, (cited 7 July, 2010)
    • World Health Organization, WHO Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide, global update 2005, Summary of risk assessment, http://whqlibdoc.who. int/hq/2006/WHO SDE PHE OEH 06.02 eng.pdf, (cited 7 July, 2010).
  • 46
    • 85036754097 scopus 로고    scopus 로고
    • World Health Organization, Development of WHO guidelines for indoor air quality, Report on a working group meeting, Bonn, Germany, 23-24 October 2006, (cited 3 July, 2010)
    • World Health Organization, Development of WHO guidelines for indoor air quality, Report on a working group meeting, Bonn, Germany, 23-24 October 2006, http://www.euro.who.int/ data/ assets/pdf file/0007/78613/AIQIAQ mtgrep Bonn Oct06.pdf, (cited 3 July, 2010).
  • 47
    • 85036762071 scopus 로고    scopus 로고
    • Behavior of nitrogen dioxide in the indoor environment
    • (in Japanese)
    • Okudaira, J. and Tanaka, T. (2005) Behavior of nitrogen dioxide in the indoor environment. Indoor Environ., 8, 27-34 (in Japanese).
    • (2005) Indoor Environ , vol.8 , pp. 27-34
    • Okudaira, J.1    Tanaka, T.2
  • 48
    • 50049109302 scopus 로고    scopus 로고
    • Environmental Issues in Managing asthma
    • Diette, G. B., McCormack, M. C., Hansel, N, N., Breysse, P. N. and Matsui, E. C. (2008) Environmental Issues in Managing asthma. Respir. Care, 53, 602-617.
    • (2008) Respir. Care , vol.53 , pp. 602-617
    • Diette, G.B.1    McCormack, M.C.2    Hansel, N.3
  • 51
    • 85036731605 scopus 로고    scopus 로고
    • Measurement results of personal exposure levels of nitrogen dioxide and formaldehyde
    • (in Japanese)
    • Matsumura, T., Osada, E. and Ando, M. (1998) Measurement results of personal exposure levels of nitrogen dioxide and formaldehyde. Indoor Environ., 1, 19-26 (in Japanese).
    • (1998) Indoor Environ , vol.1 , pp. 19-26
    • Matsumura, T.1    Osada, E.2    Ando, M.3
  • 52
    • 84913030009 scopus 로고
    • Sulfur oxides and suspended particulate matter
    • International Program on Chemical Safety (IPCS) 8, World Health Organization, Geneva
    • International Program on Chemical Safety (IPCS) (1979) Sulfur oxides and suspended particulate matter. Environmental Health Criteria 8, World Health Organization, Geneva.
    • (1979) Environmental Health Criteria
  • 54
    • 85036735325 scopus 로고    scopus 로고
    • Indoor airborne fungi in the house of a patient with pulmonary aspergillosis
    • (in Japanese)
    • Kawakami, Y. and Takahashi, Y. (2007) Indoor airborne fungi in the house of a patient with pulmonary aspergillosis. Indoor Environ., 10, 155-162 (in Japanese)
    • (2007) Indoor Environ , vol.10 , pp. 155-162
    • Kawakami, Y.1    Takahashi, Y.2
  • 56
    • 85036750837 scopus 로고    scopus 로고
    • Damage case by fungi caused because of wrong utility work, and about the trial afterwards
    • (in Japanese)
    • Nishiguchi, T., Kawakami, Y. and Miyaoka, T. (2009) Damage case by fungi caused because of wrong utility work, and about the trial afterwards. Indoor Environ., 12, 13-24 (in Japanese).
    • (2009) Indoor Environ , vol.12 , pp. 13-24
    • Nishiguchi, T.1    Kawakami, Y.2    Miyaoka, T.3
  • 57
    • 0347720025 scopus 로고    scopus 로고
    • Fungal Index and Contamination in Air Conditioners when cooled
    • (in Japanese)
    • Abe, K. (1998) Fungal Index and Contamination in Air Conditioners when cooled. Indoor Environ., 1, 41-50 (in Japanese).
    • (1998) Indoor Environ , vol.1 , pp. 41-50
    • Abe, K.1
  • 58
    • 85036744978 scopus 로고    scopus 로고
    • Inhibitive Effect for Mold Growth Inside of the Room using a Heat Exchange Type of Ventilator Equipped with Dehumidification Function
    • (in Japanese)
    • Yamashita, N., Matsumoto, Y. and Abe, K. (2009) Inhibitive Effect for Mold Growth Inside of the Room using a Heat Exchange Type of Ventilator Equipped with Dehumidification Function. Indoor Environ., 12, 143-150 (in Japanese).
    • (2009) Indoor Environ , vol.12 , pp. 143-150
    • Yamashita, N.1    Matsumoto, Y.2    Abe, K.3
  • 59
    • 85036739920 scopus 로고    scopus 로고
    • Healthy influence and the regulations on mold
    • (in Japanese)
    • Yanagi, U. (2008) Healthy influence and the regulations on mold. Indoor Environ., 11, 111-116 (in Japanese).
    • (2008) Indoor Environ , vol.11 , pp. 111-116
    • Yanagi, U.1
  • 60
    • 85036767907 scopus 로고    scopus 로고
    • An outbreak of Aspergillus ochraceusWilhelm in a House in Yokohama, Kanagawa Prefecture
    • (in Japanese)
    • Kawakami, Y. (2006) An outbreak of Aspergillus ochraceusWilhelm in a House in Yokohama, Kanagawa Prefecture. Indoor Environ., 9, 37-43 (in Japanese).
    • (2006) Indoor Environ , vol.9 , pp. 37-43
    • Kawakami, Y.1
  • 61
    • 34247355265 scopus 로고    scopus 로고
    • Relationship between indoor air pollutants and living environment and subjective symptoms
    • (in Japanese)
    • Yamasaki, Y., Wang, B., Sakano, N., Wang, D. and Takigawa, T. (2006) Relationship between indoor air pollutants and living environment and subjective symptoms. Indoor Environ., 9, 25-36 (in Japanese).
    • (2006) Indoor Environ , vol.9 , pp. 25-36
    • Yamasaki, Y.1    Wang, B.2    Sakano, N.3    Wang, D.4    Takigawa, T.5
  • 62
    • 0038627911 scopus 로고    scopus 로고
    • Adverse human health effects associated with molds in the indoor environment: American College of Occupational and Environmental Medicine (ACOEM) evidence-based statement
    • Hardin, B. D., Kelman, B. J. and Saxon, A. (2003) Adverse human health effects associated with molds in the indoor environment: American College of Occupational and Environmental Medicine (ACOEM) evidence-based statement. J. Occup. Environ. Med., 45, 470-478.
    • (2003) J. Occup. Environ. Med , vol.45 , pp. 470-478
    • Hardin, B.D.1    Kelman, B.J.2    Saxon, A.3
  • 63
    • 85036771583 scopus 로고    scopus 로고
    • Introduction to mold in American buildings
    • (in Japanese)
    • Shimizu, S. (2007) Introduction to mold in American buildings. Indoor Environ., 11, 167-168 (in Japanese).
    • (2007) Indoor Environ , vol.11 , pp. 167-168
    • Shimizu, S.1
  • 64
    • 0001553616 scopus 로고    scopus 로고
    • Ten minutes in a clothes dryer kills all mites in blankets
    • Miller, J. D. and Miller, A. (1996) Ten minutes in a clothes dryer kills all mites in blankets. J. Allergy Clin. Immunol., 97, 423.
    • (1996) J. Allergy Clin. Immunol , vol.97 , pp. 423
    • Miller, J.D.1    Miller, A.2
  • 65
    • 85036729351 scopus 로고    scopus 로고
    • Themeasurement of house dustmite allergen by several tools for determination and the comparison of their value
    • (in Japanese)
    • Takeda, S., Mori, Y., Inada, T., Sato, Y. and Itagaki, K. (2008) Themeasurement of house dustmite allergen by several tools for determination and the comparison of their value. Indoor Environ., 11, 1-9 (in Japanese).
    • (2008) Indoor Environ , vol.11 , pp. 1-9
    • Takeda, S.1    Mori, Y.2    Inada, T.3    Sato, Y.4    Itagaki, K.5
  • 66
  • 67
    • 85036730354 scopus 로고    scopus 로고
    • World Health Organization, Air quality and health; WHO air quality guidelines for Europe, 2nd Ed, (cited 3 July, 2010)
    • World Health Organization, Air quality and health; WHO air quality guidelines for Europe, 2nd Ed., http://www.euro.who.int/ data/assets/pdf file/0005/ 74732/E71922.pdf, (cited 3 July, 2010).
  • 68
    • 85036736471 scopus 로고    scopus 로고
    • Ministry of Health Labour and Welfare, Committee on Sick House Syndrome: Indoor Air Pollution Progress Report No. 4-Summary on the discussions at the 8th and 9th meetings, (cited 7 July, 2010)
    • Ministry of Health Labour and Welfare, Committee on Sick House Syndrome: Indoor Air Pollution Progress Report No. 4-Summary on the discussions at the 8th and 9th meetings-, http:// www.nihs.go.jp/mhlw/chemical/situnai/kentoukai/ rep-eng4.html, (cited 7 July, 2010)
  • 69
    • 85036767537 scopus 로고    scopus 로고
    • Current status and progress of research on the effects of volatile organic compounds (VOCs) on fetuses and infants
    • (in Japanese)
    • Nakajima, D., Tsukahara, S., Kageyama, S., Shiraishi, F. and Fujikami, H. (2008) Current status and progress of research on the effects of volatile organic compounds (VOCs) on fetuses and infants. Indoor Environ., 11, 103-109 (in Japanese).
    • (2008) Indoor Environ , vol.11 , pp. 103-109
    • Nakajima, D.1    Tsukahara, S.2    Kageyama, S.3    Shiraishi, F.4    Fujikami, H.5
  • 70
    • 85036766264 scopus 로고    scopus 로고
    • Annual changes of the amount of volatile organic compounds (VOC) in indoor air
    • (in Japanese)
    • Inoue, H., Sera, Y., Ohtani, M., Sato, M., Ichinose, M. and Tamura, Y. (2007) Annual changes of the amount of volatile organic compounds (VOC) in indoor air. Indoor Environ., 10, 147-154 (in Japanese).
    • (2007) Indoor Environ , vol.10 , pp. 147-154
    • Inoue, H.1    Sera, Y.2    Ohtani, M.3    Sato, M.4    Ichinose, M.5    Tamura, Y.6
  • 71
    • 69849100165 scopus 로고    scopus 로고
    • Indoor Air Pollution of volatile organic compounds-Indoor/Outdoor concentration, sources and exposure
    • (in Japanese)
    • Chikara, H., Iwamoto, S. and Yoshimura, T. (2009) Indoor Air Pollution of volatile organic compounds-Indoor/Outdoor concentration, sources and exposure-. Jpn. J. Hyg., 64, 683-688 (in Japanese).
    • (2009) Jpn J. Hyg , vol.64 , pp. 683-688
    • Chikara, H.1    Iwamoto, S.2    Yoshimura, T.3
  • 72
    • 69849093039 scopus 로고    scopus 로고
    • Potential risk of indoor semivolatile organic compounds indoors to human health
    • (in Japanese)
    • Kanazawa, A. and Kishi, R. (2009) Potential risk of indoor semivolatile organic compounds indoors to human health. Jpn. J. Hyg., 64, 672-682 (in Japanese).
    • (2009) Jpn. J. Hyg , vol.64 , pp. 64
    • Kanazawa, A.1    Kishi, R.2
  • 73
    • 85036731596 scopus 로고
    • IPCS Environmental Health Criteria 89 Formaldehyde, WorldHealth Organization, Geneva
    • IPCS (1989) Environmental Health Criteria 89 Formaldehyde, WorldHealth Organization, Geneva
    • (1989)
  • 74
    • 63349095488 scopus 로고    scopus 로고
    • Relationship between sick building syndrome and indoor environmental factors in newly built Japanese dwellings
    • Takeda, M., Saijo, Y., Yuasa, M., Kanazawa, A., Araki, A. and Kishi, R. (2009) Relationship between sick building syndrome and indoor environmental factors in newly built Japanese dwellings. Int. Arch. Occup. Environ. Health, 82, 583-593.
    • (2009) Int. Arch. Occup. Environ. Health , vol.82 , pp. 583-593
  • 75
    • 85036727142 scopus 로고    scopus 로고
    • Changes in the airborne concentrations of formaldehyde and volatile organic compounds in an elementary schoolroom over two years after renovation
    • (in Japanese)
    • Hara, K., Mori, M., Ishitake, T., Harada, K., Wei, C. N., Ohmori, S. and Ueda, A. (2007) Changes in the airborne concentrations of formaldehyde and volatile organic compounds in an elementary schoolroom over two years after renovation. Indoor Environ., 9, 97-103 (in Japanese).
    • (2007) Indoor Environ , vol.9 , pp. 97-103
    • Hara, K.1    Mori, M.2    Ishitake, T.3    Harada, K.4    Wei, C.N.5    Ohmori, S.6    Ueda, A.7
  • 76
    • 85036745354 scopus 로고    scopus 로고
    • A survey of chemical substances in residences
    • (in Japanese)
    • Otsuka, K., Matsumura, T. and Hamada, M. (2002) A survey of chemical substances in residences. Indoor Environ., 5, 23-35 (in Japanese).
    • (2002) Indoor Environ , vol.5 , pp. 23-35
    • Otsuka, K.1    Matsumura, T.2    Hamada, M.3
  • 77
    • 29144511457 scopus 로고    scopus 로고
    • A survey of Indoor and Outdoor air pollution by aldehydes in summer in Fuji, Shizuoka
    • (in Japanese)
    • Amagai, T., Ohmura, T., Sugiyama, T., Fusaya, M. and Matsushita, H. (2000) A survey of Indoor and Outdoor air pollution by aldehydes in summer in Fuji, Shizuoka. Indoor Environ., 3, 35-43 (in Japanese).
    • (2000) Indoor Environ , vol.3 , pp. 35-43
    • Amagai, T.1    Ohmura, T.2    Sugiyama, T.3    Fusaya, M.4    Matsushita, H.5
  • 79
    • 2442551520 scopus 로고    scopus 로고
    • Effects of pollution from personal computers on Perceived air Quality, SBS symptoms and productivity in offices
    • Bako-Biro, Z. Waargocki, P, Weschler, C. J. and Fanger, P. O. (2004) Effects of pollution from personal computers on Perceived air Quality, SBS symptoms and productivity in offices. Indoor Air, 14, 178-187.
    • (2004) Indoor Air , vol.14 , pp. 178-187
    • Bako-Biro, Z.1    Waargocki, P.2    Weshler, C.J.3    Fanger, P.O.4
  • 81
    • 85036732925 scopus 로고    scopus 로고
    • IPCS, Chemical Safety Information from Intergovernmental Organizations, (cited 4 July, 2010)
    • IPCS, Chemical Safety Information from Intergovernmental Organizations, http://www.inchem.org/, (cited 4 July, 2010).
  • 82
    • 37249074418 scopus 로고    scopus 로고
    • The Risk Screening for Indoor Air Pollution Chemicals in Japan
    • Azuma, K., Uchiyama, I. and Ikeda, K. (2007) The Risk Screening for Indoor Air Pollution Chemicals in Japan. Risk Anal., 27, 1623-1638.
    • (2007) Risk Anal , vol.27 , pp. 1623-1638
    • Azuma, K.1    Uchiyama, I.2    Ikeda, K.3
  • 87
    • 33644877617 scopus 로고    scopus 로고
    • Significance of laboratory studies of neurobehavioral and developmental toxicities-Transgenerational effects of styrene exposure
    • (in Japanese)
    • Katakura, Y. and Kishi, R. (2005) Significance of laboratory studies of neurobehavioral and developmental toxicities-Transgenerational effects of styrene exposure-. Jpn. J. Hyg., 60, 411-417 (in Japanese).
    • (2005) Jpn J. Hyg , vol.60 , pp. 411-417
    • Katakura, Y.1    Kishi, R.2
  • 88
    • 33644877617 scopus 로고    scopus 로고
    • Significance of laboratory studies of neurobehavioral and developmental toxicities-Transgenerational effects of styrene exposure
    • Katakura, Y. and Kishi, R. (2005) Significance of laboratory studies of neurobehavioral and developmental toxicities-Transgenerational effects of styrene exposure-. Jpn. J. Hyg., 60, 411-417
    • (2005) Jpn. J. Hyg , vol.60 , pp. 411-417
    • Katakura, Y.1    Kishi, R.2
  • 90
    • 21044445368 scopus 로고    scopus 로고
    • Chlorpyrifos and S-421 residue in indoor airand polished rice around nine years after application for termite control
    • (in Japanese)
    • Yoshida, S., Taguchi, S., Hori, S. and Hori, S. (2004) Chlorpyrifos and S-421 residue in indoor airand polished rice around nine years after application for termite control. Indoor Environ., 7, 7-15 (in Japanese).
    • (2004) Indoor Environ , vol.7 , pp. 7-15
    • Yoshida, S.1    Taguchi, S.2    Hori, S.3    Hori, S.4
  • 91
    • 85036761667 scopus 로고    scopus 로고
    • Investigation of insecticide residue in household dust as an index for residential exposure to pesticide
    • (in Japanese)
    • Yoshida, S., Taguchi, S., Tanaka, Y. and Hori, S. (2003) Investigation of insecticide residue in household dust as an index for residential exposure to pesticide. Indoor Environ., 6, 1-8 (in Japanese).
    • (2003) Indoor Environ , vol.6 , pp. 1-8
    • Yoshida, S.1    Taguchi, S.2    Tanaka, Y.3    Hori, S.4
  • 93
    • 4544368700 scopus 로고    scopus 로고
    • Determination of phthalates in indoor air
    • (in Japanese)
    • Saito, I., Seto, H. and Seto, H. (2002) Determination of phthalates in indoor air. Indoor Environ., 5, 13-22 (in Japanese).
    • (2002) Indoor Environ , vol.5 , pp. 13-22
    • Saito, I.1    Seto, H.2    Seto, H.3
  • 94
    • 2442466688 scopus 로고    scopus 로고
    • Occurrence of phthalates and milk fragrances in indoor air and dust from apartments and kindergartens in Berlin (Germany)
    • Fromme, H., Lahrz, T., Piloty, M., Gehhart, H., Oddoy, A. and Ruden, H. (2004) Occurrence of phthalates and milk fragrances in indoor air and dust from apartments and kindergartens in Berlin (Germany). Indoor Air, 14, 188-195
    • (2004) Indoor Air , vol.14 , pp. 188-195
    • Fromme, H.1    Lahrz, T.2    Piloty, M.3    Gehhart, H.4    Oddoy, A.5    Ruden, H.6
  • 95
    • 85036766412 scopus 로고    scopus 로고
    • Japan Chemical Substance Dictionary Web service,Easy Textual Search, Advanced Textual Search, Chemical Structure Search, (cited 4 July, 2010)
    • Japan Chemical Substance Dictionary Web service,Easy Textual Search, Advanced Textual Search, Chemical Structure Search, http://nikkajiweb.jst. go.jp/nikkaji web/pages/top e.html, (cited 4 July, 2010).
  • 96
    • 0037084096 scopus 로고    scopus 로고
    • Predicting the Emission Rate of Volatile Organic Compounds from Vinyl Flooring
    • Steven, S. C., Little, J. C. and Hodgson, A. T. (2002) Predicting the Emission Rate of Volatile Organic Compounds from Vinyl Flooring. Environ. Sci. Technol., 36, 709-714.
    • (2002) Environ. Sci. Technol , vol.36 , pp. 709-714
    • Steven, S.C.1    Little, J.C.2    Hodgson, A.T.3
  • 98
    • 78049309028 scopus 로고    scopus 로고
    • Risk assessment of chemical via house dust ingestion in Japanese children
    • Takagi, M. and Yoshinaga, J. (2009) Risk assessment of chemical via house dust ingestion in Japanese children. Indoor Environ., 12, 103-114 (in Japanese).
    • (2009) Indoor Environ , vol.12 , pp. 103-114
    • Takagi, M.1    Yoshinaga, J.2
  • 99
    • 33746517515 scopus 로고    scopus 로고
    • Estimation of Intake Level of Di (2-ethylhecyl) phthalate (DEHP) of Japanese pregnant woman based on measurement of concentrations of three urinarymetabolites
    • (in Japanese)
    • Fujimaki, K., Yoshinaga, J., Watanabe, C., Serizawa, S., Shiraishi, H. and Mizumoto, Y. (2006) Estimation of Intake Level of Di (2-ethylhecyl) phthalate (DEHP) of Japanese pregnant woman based on measurement of concentrations of three urinarymetabolites. Jpn. J. Hyg., 61, 340-347 (in Japanese).
    • (2006) Jpn. J. Hyg , vol.61 , pp. 340-347
    • Fujimaki, K.1    Yoshinaga, J.2    Watanabe, C.3    Serizawa, S.4    Shiraishi, H.5    Mizumoto, Y.6
  • 101
    • 85036761903 scopus 로고    scopus 로고
    • IPCS (1998) Environmental Health Criteria 198 Diazinon, World Health Organization, Geneva
    • IPCS (1998) Environmental Health Criteria 198 Diazinon, World Health Organization, Geneva.
  • 102
    • 44649191135 scopus 로고    scopus 로고
    • An observational study of thepotential for human exposure to pet-borne diazinon residue following lawn applications
    • Morgan, M. K., Stout, D. M., Jones, P. A. and Barr, D. B. (2008) An observational study of thepotential for human exposure to pet-borne diazinon residue following lawn applications. Environ. Res., 107, 336-342.
    • (2008) Environ. Res , vol.107 , pp. 336-342
    • Morgan, M.K.1    Stout, D.M.2    Jones, P.A.3    Barr, D.B.4
  • 103
    • 85036727925 scopus 로고    scopus 로고
    • Establishment of an analysis method for nonanal and decanal using 2,4- dinitrophenylhydrazine-HPLC and a survey of indoor air
    • in Japanese
    • Onuki, A., Saito, I., Seto, H. and Urehara, S. (2005) Establishment of an analysis method for nonanal and decanal using 2,4- dinitrophenylhydrazine-HPLC and a survey of indoor air. Indoor Environ., 8, 1-8 (in Japanese).
    • (2005) Indoor Environ , vol.8 , pp. 1-8
    • Onuki, A.1    Saito, I.2    Seto, H.3    Urehara, S.4
  • 104
    • 85036743118 scopus 로고    scopus 로고
    • IPCS(1995) Environmental Health Criteria 167 Acetaldehyde, World Health Organization, Geneva
    • IPCS(1995) Environmental Health Criteria 167 Acetaldehyde, World Health Organization, Geneva
  • 105
    • 85036770274 scopus 로고    scopus 로고
    • Measurement of carbonyl compounds in air of household refrigerators by DNPH-HPLC system
    • in Japanese
    • Murata, S., Sekine, Y. and Butugan, M. (2008) Measurement of carbonyl compounds in air of household refrigerators by DNPH-HPLC system. Indoor Environ., 11, 75-82 (in Japanese).
    • (2008) Indoor Environ , vol.11 , pp. 75-82
    • Murata, S.1    Sekine, Y.2    Butugan, M.3
  • 106
    • 85036763280 scopus 로고    scopus 로고
    • IPCS(1986) Environmental Health Criteria 64 Carbamate Pesticides; A General Introduction, WorldHealth Organization, Geneva
    • IPCS(1986) Environmental Health Criteria 64 Carbamate Pesticides; A General Introduction, WorldHealth Organization, Geneva.
  • 107
    • 2342619321 scopus 로고    scopus 로고
    • WHO Recommended Classification Ofpesticides By Hazard and Guidelines to Classification
    • IPCS, The, (cited 4 July, 2010)
    • IPCS, The WHO recommended classification ofpesticides by hazard and guidelines to classification 2004, http://www.who.int/ipcs/publications/ pesticides hazard rev 3.pdf, (cited 4 July, 2010).
    • (2004)
  • 108
    • 78049282924 scopus 로고    scopus 로고
    • Termiticidal efficacies of Fenobucarb and permethrin against Japanese subterranean termites Coptotermes formosunus ans Reticulitermes speratus (Isoptera: Rhinotermitidae)
    • Kubota, S., Shono, Y., Mito, N. and Tsunoda, K. (2008) Termiticidal efficacies of Fenobucarb and permethrin against Japanese subterranean termites Coptotermes formosunus ans Reticulitermes speratus (Isoptera: Rhinotermitidae). Jpn. J. Environ. Entomol. Zool., 19, 31-37.
    • (2008) Jpn. J. Environ. Entomol. Zool , vol.19 , pp. 31-37
    • Kubota, S.1    Shono, Y.2    Mito, N.3    Tsunoda, K.4
  • 109
    • 85036733642 scopus 로고    scopus 로고
    • Ministry of Health Labour and Welfare, Committee on sick house syndrome: Indoor air pollution, Progress repot No.1-Summary on the discussions from the 1st to 3rd meetings, (cited 4 July, 2010)
    • Ministry of Health Labour and Welfare, Committee on sick house syndrome: Indoor air pollution, Progress repot No.1-Summary on the discussions from the 1st to 3rd meetings-, http://www.nihs.go. jp/mhlw/chemical/situnai/kentoukai/rep-eng1.html, (cited 4 July, 2010).
  • 110
    • 85036729573 scopus 로고    scopus 로고
    • Study on measurement of formaldehyde, VOC, and SVOC for IAQ improvement in apartment houses
    • (in Japanese)
    • Mizoguchi, T. and Hori, M. (2008) Study on measurement of formaldehyde, VOC, and SVOC for IAQ improvement in apartment houses. ndoor Environ., 11, 83-92 (in Japanese).
    • (2008) Ndoor Environ , vol.11 , pp. 83-92
    • Mizoguchi, T.1    Hori, M.2
  • 111
    • 0033762459 scopus 로고    scopus 로고
    • Asthma symptoms in relation to measured building dampness in upper concrete floor construction, and 2-ethyl-1-hexanol in indoor air
    • Norback, D., Wieslander, G., Nordstrom, K. andWalinder, R. (2000) Asthma symptoms in relation to measured building dampness in upper concrete floor construction, and 2-ethyl-1-hexanol in indoor air. Int. J. Tuberc. Lung Dis., 4, 1016-1025.
    • (2000) Int. J. Tuberc. Lung Dis , vol.4 , pp. 1016-1025
    • Norback, D.1    Wieslander, G.2    Nordstrom, K.3    Walinder, R.4
  • 112
  • 113
    • 70449505885 scopus 로고    scopus 로고
    • Seasonal variation of indoor air pollution levels of 2-ethyl-1- hexanol in large-scale buildings in Nagoya, Japan
    • Sakai, K., Kamijima, M., Shibata, E., Ohno, H. and seasonal variation of indoor air pollution levels of 2-ethyl-1- hexanol in large-scale buildings in Nagoya, Japan. J. Environ. Monit., 11, 2068-2076.
    • J. Environ. Monit , vol.11 , pp. 2068-2076
    • Sakai, K.1    Kamijima, M.2    Shibata, E.3    Ohno, H.4
  • 116
    • 5444238373 scopus 로고    scopus 로고
    • 4-Heptanone is a metabolite of the plasticizer di(2-ethylhexyl) phthalate (DEHP) in haemodialysis patients
    • Wahl, H. G., Hong, Q., Hildenbrand, S., Risler, T., Luft, D. and Liebich, H. (2004) 4-Heptanone is a metabolite of the plasticizer di(2-ethylhexyl) phthalate (DEHP) in haemodialysis patients. Nephrol. Dial. Transplant., 19, 2576-2583.
    • (2004) Nephrol. Dial. Transplant , vol.19 , pp. 2576-2583
    • Wahl, H.G.1    Hong, Q.2    Hildenbrand, S.3    Risler, T.4    Luft, D.5    Liebich, H.6
  • 117
    • 41649100126 scopus 로고    scopus 로고
    • Health effects of nanoparticles and nanomaterials (I) recent overview of health effects of nanopartocles
    • (in Japanese)
    • Hirano, S. (2008) Health effects of nanoparticles and nanomaterials (I) recent overview of health effects of nanopartocles. Jpn. J. Hyg., 63, 36-41 (in Japanese).
    • (2008) Jpn. J. Hyg , vol.63 , pp. 36-41
    • Hirano, S.1
  • 118
    • 49049093098 scopus 로고    scopus 로고
    • Health effects of nanoparticles and nanomaterials (II) Methods for Measurement of Nanoparticles and Their Presencein the Air
    • (in Japanese)
    • Fujitani, Y. and Hirano, S. (2008) Health effects of nanoparticles and nanomaterials (II) Methods for Measurement of Nanoparticles and Their Presencein the Air. Jpn. J. Hyg., 63, 663-669 (in Japanese).
    • (2008) Jpn. J. Hyg , vol.63 , pp. 663-669
    • Fujitani, Y.1    Hirano, S.2
  • 119
    • 78049307595 scopus 로고    scopus 로고
    • Health effects of nanoparticles and nanomaterials (III) Toxicity and Health effects of Nanoparticles
    • (in Japanese)
    • Hirose, A. and Hirano, S. (2008) Health effects of nanoparticles and nanomaterials (III) Toxicity and Health effects of Nanoparticles. Jpn. J. Hyg., 63, 739-745 (in Japanese).
    • (2008) Jpn. J. Hyg , vol.63 , pp. 739-745
    • Hirose, A.1    Hirano, S.2
  • 120
    • 77249168698 scopus 로고    scopus 로고
    • A current overview of health effect research on nanoparticles
    • Hirano, S. (2009) A current overview of health effect research on nanoparticles. Environ.Health Prev. Med., 14, 223-225.
    • (2009) Environ.Health Prev. Med , vol.14 , pp. 223-225
    • Hirano, S.1
  • 121
    • 21744441208 scopus 로고    scopus 로고
    • Cytotoxicity Assessment of Some Carbon Nanotubes and Related Carbon Nanoparticle Aggregates and Implications for Anthropogenic Carbon Nanotube Aggregates in the Environment
    • III
    • Murr, L. E., Garza, K. M., Soto, K. F., Carrasco, A., Powell, T. G., Ramirez, D. A., Guerrero, P. A., Lopez, D. A. and Venzor, J., III (2005) Cytotoxicity Assessment of Some Carbon Nanotubes and Related Carbon Nanoparticle Aggregates and Implications for Anthropogenic Carbon Nanotube Aggregates in the Environment. Int. J. Environ. Res. Public Health, 2, 31-42.
    • (2005) Int. J. Environ. Res. Public Health , vol.2 , pp. 31-42
    • Murr, L.E.1    Garza, K.M.2    Soto, K.F.3    Carrasco, A.4    Powell, T.G.5    Ramirez, D.A.6    Guerrero, P.A.7    Lopez, D.A.8
  • 122
    • 78049276831 scopus 로고    scopus 로고
    • Lead and cadmium in indoor dust in Japanese houses-relationship with outdoor sources
    • (in Japanese)
    • Ishibashi, Y.,Yoshinaga, J., Tanaka, A., Seyama, H. and Shibata, Y. (2008) Lead and cadmium in indoor dust in Japanese houses-relationship with outdoor sources. Indoor Environ., 11, 93-101 (in Japanese).
    • (2008) Indoor Environ , vol.11 , pp. 93-101
    • Ishibashi, Y.1
  • 123
    • 78049243521 scopus 로고    scopus 로고
    • Element Composition of Japanese House Dust and the Source of Lead
    • (in Japanese)
    • Nakamura, Y., Yakagi, M., Yoshinaga, J., Tanaka, A., Seyama, H. and Shibata, Y. (2008) Element Composition of Japanese House Dust and the Source of Lead. Indoor Environ., 11, 11-20 (in Japanese).
    • (2008) Indoor Environ , vol.11 , pp. 11-20
    • Nakamura, Y.1    Yakagi, M.2    Yoshinaga, J.3    Tanaka, A.4    Seyama, H.5    Shibata, Y.6
  • 124
  • 125
    • 34548610629 scopus 로고
    • The Application of Semiconductor-based Odor Sensors Capable of Measuring and Evaluating Indoor Air Quality
    • (in Japanese)
    • Yamaguchi, M., Okada, H., Tomioka, K. and Suzuki, M. (1989) The Application of Semiconductor-based Odor Sensors Capable of Measuring and Evaluating Indoor Air Quality. Indoor Environ., 1, 27-34 (in Japanese).
    • (1989) Indoor Environ , vol.1 , pp. 27-34
    • Yamaguchi, M.1    Okada, H.2    Tomioka, K.3    Suzuki, M.4
  • 126
    • 65949114661 scopus 로고    scopus 로고
    • Regional differences in residential environmenets and the association of dwellings and residential factors with the sick house syndrome: A nationwide cross-sectional questionnaire study in Japan
    • Kishi, R., Saijo, Y., Kanazawa, A., Tanaka, M., Yoshimura, T., Chikara, H., Takigawa, T., Morimoto, K., Nakayama, K. and Shibata, E. (2009) Regional differences in residential environmenets and the association of dwellings and residential factors with the sick house syndrome: a nationwide cross-sectional questionnaire study in Japan. Indoor Air, 19, 243-254.
    • (2009) Indoor Air , vol.19 , pp. 243-254
    • Kishi, R.1    Saijo, Y.2    Kanazawa, A.3    Tanaka, M.4    Yoshimura, T.5    Chikara, H.6    Takigawa, T.7    Morimoto, K.8    Nakayama, K.9    Shibata, E.10
  • 127
    • 33645243567 scopus 로고    scopus 로고
    • Organic compounds in office environments-sensory irritation, odor, measurements and the role of reactive chemistry
    • Wolkoff, P., Wilkins, C. K., Clausen, P. A. and Nielsen, G. D. (2006) Organic compounds in office environments-sensory irritation, odor, measurements and the role of reactive chemistry. IndoorAir, 16, 7-19.
    • (2006) IndoorAir , vol.16 , pp. 7-19
    • Wolkoff, P.1    Wilkins, C.K.2    Clausen, P.A.3    Nielsen, G.D.4
  • 128
    • 85036729018 scopus 로고    scopus 로고
    • World Health Organization (WHO), fact sheet No.291 Radon and cancer, (cited 4 July, 2010)
    • World Health Organization (WHO), fact sheet No.291 Radon and cancer, http://www.who.int/mediacentre/factsheets/fs291/en/, (cited 4 July, 2010).
  • 130
    • 85036754620 scopus 로고    scopus 로고
    • Indoor light environment and visual environment
    • (in Japanese)
    • Iwata, T. (2008) Indoor light environment and visual environment. Indoor Environ., 11, 117-123 (in Japanese).
    • (2008) Indoor Environ , vol.11 , pp. 117-123
    • Iwata, T.1
  • 131
    • 60349117306 scopus 로고    scopus 로고
    • A newly proposed disease condition produced by light exposure during night: Asynchronization
    • Kohyama, J. (2009) A newly proposed disease condition produced by light exposure during night: Asynchronization. Brain Dev., 31, 255-273.
    • (2009) Brain Dev , vol.31 , pp. 255-273
    • Kohyama, J.1
  • 132
    • 69849106815 scopus 로고    scopus 로고
    • Risk factors for lifestyle and way of living for symptoms of sick building syndrome: Epidemiological Survey in Japan
    • (in Japanese)
    • Nakayama, K. and Morimoto, K. (2009) Risk factors for lifestyle and way of living for symptoms of sick building syndrome: Epidemiological Survey in Japan. Jpn. J. Hyg., 64, 689-698 (in Japanese).
    • (2009) Jpn. J. Hyg , vol.64 , pp. 689-698
    • Nakayama, K.1    Morimoto, K.2
  • 133
    • 78049320395 scopus 로고    scopus 로고
    • Survey of possession of furniture, items and electrical appliances in each room of Japanese residential houses, categorized according to the activity
    • Shinohara, N., Futatsuyama, M. and Gamo, M. (2009) Survey of possession of furniture, items and electrical appliances in each room of Japanese residential houses, categorized according to the activity. Indoor Environ., 12, 115-124 (in Japanese).
    • (2009) Indoor Environ , vol.12 , pp. 115-124
    • Shinohara, N.1    Futatsuyama, M.2    Gamo, M.3
  • 134
    • 33745388746 scopus 로고    scopus 로고
    • A nationwide study of indoor and outdoor environments in allergen avoidance and conventional daycare centers in Sweden
    • Brroms, K., Svardsudd, K., Sundelin, C. and Norback, D. (2006) A nationwide study of indoor and outdoor environments in allergen avoidance and conventional daycare centers in Sweden. Indoor Air, 16, 227-235.
    • (2006) Indoor Air , vol.16 , pp. 227-235
    • Brroms, K.1    Svardsudd, K.2    Sundelin, C.3    Norback, D.4
  • 135
    • 85036756656 scopus 로고    scopus 로고
    • Measures for reducing the levels of chemical compounds in the indoor air of schools-A study of the effect of ventilation-
    • (in Japanese)
    • Takekuma, M., Ohmura, A. and Saito, K. (2005) Measures for reducing the levels of chemical compounds in the indoor air of schools-A study of the effect of ventilation-. Indoor Environ., 8, 35-39 (in Japanese).
    • (2005) Indoor Environ , vol.8 , pp. 35-39
    • Takekuma, M.1    Ohmura, A.2    Saito, K.3
  • 136
    • 38349026554 scopus 로고    scopus 로고
    • Lab-scale test of a ventilation system including a dielectric barrier discharger and UVphotocatalyst filters for simultaneous removal of gaseous and particulate contaminants
    • Park, J. H., Byeon, J. H., Yoon, K. Y. and Hwang, J. (2008) Lab-scale test of a ventilation system including a dielectric barrier discharger and UVphotocatalyst filters for simultaneous removal of gaseous and particulate contaminants. Indoor Air, 18, 44-50.
    • (2008) Indoor Air , vol.18 , pp. 44-50
    • Park, J.H.1    Byeon, J.H.2    Yoon, K.Y.3    Hwang, J.4
  • 137
    • 85036748075 scopus 로고    scopus 로고
    • Indoor environment of a nursery school
    • (in Japanese)
    • Otsuki, C. (2008) Indoor environment of a nursery school. Indoor Environ., 11, 33-35 (in Japanese).
    • (2008) Indoor Environ , vol.11 , pp. 33-35
    • Otsuki, C.1
  • 138
    • 77249133222 scopus 로고    scopus 로고
    • Use of a mathematical model to estimate turberculosis transmission risk in an Internet caf ́e
    • Furusawa, H., Nagamine, M. and Watanabe, T. (2009) Use of a mathematical model to estimate turberculosis transmission risk in an Internet caf ́e. Environ. Health Prev. Med., 14, 96-102.
    • (2009) Environ. Health Prev. Med , vol.14 , pp. 96-102
    • Furusawa, H.1    Nagamine, M.2    Watanabe, T.3
  • 139
    • 85036759262 scopus 로고    scopus 로고
    • Evaluation of the bake-out method to decrease indoor air pollution caused by volatile organic compounds
    • (in Japanese)
    • Liu, Y. (2002) Evaluation of the bake-out method to decrease indoor air pollution caused by volatile organic compounds. Indoor Environ., 5, 1-6 (in Japanese).
    • (2002) Indoor Environ , vol.5 , pp. 1-6
    • Liu, Y.1
  • 140
    • 85036725667 scopus 로고    scopus 로고
    • Examination of reduction of indoor chemical pollutants using air conditioners
    • (in Japanese)
    • Kitamura, Y., Otani, M., Okada, M., Omura, M. and Monna, Y. (2005) Examination of reduction of indoor chemical pollutants using air conditioners. IndoorEnviron., 8, 41-46 (in Japanese).
    • (2005) IndoorEnviron , vol.8 , pp. 41-46
    • Kitamura, Y.1    Otani, M.2    Okada, M.3    Omura, M.4    Monna, Y.5
  • 141
    • 78049250464 scopus 로고    scopus 로고
    • An activity news flash of microbe working group-Evaluation of an air cleaner on removal performance of airborne microbe-
    • (in Japanese)
    • Abe, K., Suyama, Y., Yagami, U., Okuda, S. and Otsuka, T. (2007) An activity news flash of microbe working group-Evaluation of an air cleaner on removal performance of airborne microbe-. Indoor Environ., 10, 163-166 (in Japanese).
    • (2007) Indoor Environ , vol.10 , pp. 63-166
    • Abe, K.1    Suyama, Y.2    Yagami, U.3    Okuda, S.4    Otsuka, T.5
  • 142
    • 72449184816 scopus 로고    scopus 로고
    • The effective of carbonization temperature on the ability of charcoal to adsorb mixed volatile organic compounds
    • (in Japanese)
    • Nakajima, D., Suzuki, K., Goto, S., Yajima, H., Ishii, T., Yoshizawa, S., Watanabe, I. and Sakai, S. (2005) The effective of carbonization temperature on the ability of charcoal to adsorb mixed volatile organic compounds. Indoor Environ., 8, 9-14 (in Japanese).
    • (2005) Indoor Environ , vol.8 , pp. 9-14
    • Nakajima, D.1    Suzuki, K.2    Goto, S.3    Yajima, H.4    Ishii, T.5    Yoshizawa, S.6    Watanabe, I.7    Sakai, S.8
  • 143
    • 78049238698 scopus 로고    scopus 로고
    • Suppression of fungal growth inside air-conditioners using the intermittent short-time-heating method
    • (in Japanese)
    • Sato, S. and Abe, K. (2004) Suppression of fungal growth inside air-conditioners using the intermittent short-time-heating method. Indoor Environ., 7, 25- 30 (in Japanese).
    • (2004) Indoor Environ , vol.7 , pp. 25-30
    • Sato, S.1    Abe, K.2
  • 144
    • 35348875044 scopus 로고
    • Electrochemi photolysis of water at a semiconductor electrode
    • Fujishima, A. and Honda, K. (1972) Electrochemi photolysis of water at a semiconductor electrode. Nature, 238, 37-38.
    • (1972) Nature , vol.238 , pp. 37-38
    • Fujishima, A.1    Honda, K.2
  • 145
    • 61349180727 scopus 로고    scopus 로고
    • Application of visible-light photocatalysis with nitrogen-doped or unmodified titanium dioxide for control of indoorlevel volatile organic compounds
    • Jo, W. K. and Kim, J. T. (2009) Application of visible-light photocatalysis with nitrogen-doped or unmodified titanium dioxide for control of indoorlevel volatile organic compounds. J. Hazard.Mater., 164, 360-366.
    • (2009) J. Hazard.Mater , vol.164 , pp. 360-366
    • Jo, W.K.1    Kim, J.T.2
  • 146
    • 51449097300 scopus 로고    scopus 로고
    • Innovative PCDD/F-containing gas generating system applied in catalytic decomposition of gaseous dioxins over V2O5-WO3/TiO2-based catalysts
    • Yang, C. C., Chang, S. H., Hong, B. Z., Chi, K. H. and Chang, M. B. (2008) Innovative PCDD/F-containing gas generating system applied in catalytic decomposition of gaseous dioxins over V2O5-WO3/TiO2-based catalysts. Chemosphere, 73, 890-895
    • (2008) Chemosphere , vol.73 , pp. 890-895
    • Yang, C.C.1    Chang, S.H.2    Hong, B.Z.3    Chi, K.H.4    Chang, M.B.5
  • 147
    • 67349103765 scopus 로고    scopus 로고
    • Effect of TiO2/adsorbent hybrid photocatalysts for toluene decomposition in gas phase
    • Mo, J.,Zhang, Y., Xu, Q. and Yang, R. (2009) Effect of TiO2/adsorbent hybrid photocatalysts for toluene decomposition in gas phase. J. Hazard. Mater., 168, 276-281.
    • (2009) J. Hazard. Mater , vol.168 , pp. 276-281
    • Mo, J.1
  • 148
    • 66149178841 scopus 로고    scopus 로고
    • Study of catalytic decomposition of formaldehyde on Pt/TiO2 alumite catalyst at ambient temperature
    • Wang, L., Sakurai, M. and Kameyama, H. (2009) Study of catalytic decomposition of formaldehyde on Pt/TiO2 alumite catalyst at ambient temperature. J. Hazard. Mater., 167, 399-405.
    • (2009) J. Hazard. Mater , vol.167 , pp. 399-405
    • Wang, L.1    Sakurai, M.2    Kameyama, H.3
  • 149
    • 69249208466 scopus 로고    scopus 로고
    • Photocatalytic activity of titanium dioxide modified concrete materials-Influence of utilizing recycled glass cullets as aggregates
    • Chen, J. and Poon, C. S. (2009) Photocatalytic activity of titanium dioxide modified concrete materials-Influence of utilizing recycled glass cullets as aggregates, J. Environ. Manage., 90, 3436- 3442.
    • (2009) J. Environ. Manage , vol.90 , pp. 3436-3442
    • Chen, J.1    Poon, C.S.2
  • 150
    • 46449133619 scopus 로고    scopus 로고
    • Preparation of titanium dioxide photocatalyst loaded onto activated carbon support using chemical vapor deposition: A review paper
    • Puma, C. L., Bono, A., Krishnaiah, D. and Collin, J. G. (2008) Preparation of titanium dioxide photocatalyst loaded onto activated carbon support using chemical vapor deposition: A review paper. J. Hazard. Mater., 157, 209-219.
    • (2008) J. Hazard. Mater , vol.157 , pp. 209-219
    • Puma, C.L.1    Bono, A.2    Krishnaiah, D.3    Collin, J.G.4
  • 151
    • 85036724447 scopus 로고    scopus 로고
    • Determination of the emission of volatile organic compounds and aldehydes for building products- small chamber method, JIS A 1901:2003
    • Determination of the emission of volatile organic compounds and aldehydes for building products- small chamber method, JIS A 1901:2003.
  • 152
    • 69849094456 scopus 로고    scopus 로고
    • Sick house syndrome: Government actions and challenges
    • Hasegawa, T. and Kigawa, M. (2009) Sick house syndrome: government actions and challenges. Jpn.J. Hyg., 64, 699-703 (in Japanese).
    • (2009) Jpn.J. Hyg , vol.64 , pp. 699-703
    • Hasegawa, T.1    Kigawa, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.