메뉴 건너뛰기




Volumn 54, Issue 2, 2010, Pages 145-156

Myocardial perfusion PET/CT to evaluate known and suspected coronary artery disease

Author keywords

Coronary artery disease; Diagnostic imaging; Myocardial perfusion imaging; Positron emission tomography

Indexed keywords

AMMONIA N 13; CALCIUM; DOBUTAMINE; RUBIDIUM 82; TRACER;

EID: 77958547565     PISSN: 18244785     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (17)

References (53)
  • 1
    • 51349097346 scopus 로고    scopus 로고
    • Radiopharmaceuticals for nuclear cardiology: Radiation dosimetry, uncertainties, and risk
    • Stabin MG. Radiopharmaceuticals for nuclear cardiology: radiation dosimetry, uncertainties, and risk. J Nucl Med 2008;49:1555-63.
    • (2008) J Nucl Med , vol.49 , pp. 1555-1563
    • Stabin, M.G.1
  • 2
    • 34147101153 scopus 로고    scopus 로고
    • New technology for non-invasive evaluation of coronary artery disease
    • Di Carli MF, Hachamovitch R. New technology for non-invasive evaluation of coronary artery disease. Circulation 2007;115:1464-80.
    • (2007) Circulation , vol.115 , pp. 1464-1480
    • Di Carli, M.F.1    Hachamovitch, R.2
  • 3
    • 33847410522 scopus 로고    scopus 로고
    • Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease
    • Sampson UK, Dorbala S, Limaye A, Kwong R, Di Carli MF. Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease. J Am Coll Cardiol 2007;49:1052-8.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 1052-1058
    • Sampson, U.K.1    Dorbala, S.2    Limaye, A.3    Kwong, R.4    Di Carli, M.F.5
  • 4
    • 32044472882 scopus 로고    scopus 로고
    • Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    • Bateman TM, Heller GV, McGhie AI, Friedman JD, Case JA, Bryngelson JR et al. Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT. J Nucl Cardiol 2006;13:24-33.
    • (2006) J Nucl Cardiol , vol.13 , pp. 24-33
    • Bateman, T.M.1    Heller, G.V.2    McGhie, A.I.3    Friedman, J.D.4    Case, J.A.5    Bryngelson, J.R.6
  • 5
    • 0026857579 scopus 로고
    • Diagnosis of coronary artery disease using exercise echocardiography and positron emission tomography: Comparison and analysis of discrepant results
    • Marwick TH, Nemec JJ, Stewart WJ, Salcedo EE. Diagnosis of coronary artery disease using exercise echocardiography and positron emission tomography: comparison and analysis of discrepant results. J Am Soc Echocardiogr 1992;5:231-8.
    • (1992) J Am Soc Echocardiogr , vol.5 , pp. 231-238
    • Marwick, T.H.1    Nemec, J.J.2    Stewart, W.J.3    Salcedo, E.E.4
  • 7
    • 0025913219 scopus 로고
    • Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease
    • Stewart RE, Schwaiger M, Molina E, Popma J, Gacioch GM, Kalus M et al. Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease. Am J Cardiol 1991;67:1303-10.
    • (1991) Am J Cardiol , vol.67 , pp. 1303-1310
    • Stewart, R.E.1    Schwaiger, M.2    Molina, E.3    Popma, J.4    Gacioch, G.M.5    Kalus, M.6
  • 8
    • 0025605314 scopus 로고
    • A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease
    • see comments
    • Go RT, Marwick TH, MacIntyre WJ, Saha GB, Neumann DR, Underwood DA et al. A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease [see comments]. J Nucl Med 1990;31:1899-905.
    • (1990) J Nucl Med , vol.31 , pp. 1899-1905
    • Go, R.T.1    Marwick, T.H.2    MacIntyre, W.J.3    Saha, G.B.4    Neumann, D.R.5    Underwood, D.A.6
  • 9
    • 0024544514 scopus 로고
    • Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients
    • Demer LL, Gould KL, Goldstein RA, Kirkeeide RL, Mullani NA, Smalling RW et al. Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients. Circulation 1989;79:825-35.
    • (1989) Circulation , vol.79 , pp. 825-835
    • Demer, L.L.1    Gould, K.L.2    Goldstein, R.A.3    Kirkeeide, R.L.4    Mullani, N.A.5    Smalling, R.W.6
  • 10
    • 0023885887 scopus 로고
    • Value and limitation of stress thallium-201 single photon emission computed tomography: Comparison with nitrogen-13 ammonia positron tomography
    • Tamaki N, Yonekura Y, Senda M, Yamashita K, Koide H, Saji H et al. Value and limitation of stress thallium-201 single photon emission computed tomography: comparison with nitrogen-13 ammonia positron tomography. J Nucl Med 1988;29:1181-8.
    • (1988) J Nucl Med , vol.29 , pp. 1181-1188
    • Tamaki, N.1    Yonekura, Y.2    Senda, M.3    Yamashita, K.4    Koide, H.5    Saji, H.6
  • 11
    • 0022632854 scopus 로고
    • Non-invasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VIII. Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82
    • Gould KL, Goldstein RA, Mullani NA, Kirkeeide RL, Wong WH, Tewson TJ et al. Non-invasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VIII. Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82. J Am Coll Cardiol 1986;7:775-89.
    • (1986) J Am Coll Cardiol , vol.7 , pp. 775-789
    • Gould, K.L.1    Goldstein, R.A.2    Mullani, N.A.3    Kirkeeide, R.L.4    Wong, W.H.5    Tewson, T.J.6
  • 12
    • 34247208691 scopus 로고    scopus 로고
    • Value of vasodilator left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: A 82Rb PET/CT study
    • Dorbala S, Vangala D, Sampson U, Limaye A, Kwong R, Di Carli MF. Value of vasodilator left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: a 82Rb PET/CT study. J Nucl Med 2007;48:349-58.
    • (2007) J Nucl Med , vol.48 , pp. 349-358
    • Dorbala, S.1    Vangala, D.2    Sampson, U.3    Limaye, A.4    Kwong, R.5    Di Carli, M.F.6
  • 13
    • 38349154101 scopus 로고    scopus 로고
    • Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated (82)rubidium myocardial perfusion PET
    • Brown TL, Merrill J, Volokh L, Bengel FM. Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated (82)rubidium myocardial perfusion PET. Eur J Nucl Med Mol Imaging 2008;35:336-42.
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 336-342
    • Brown, T.L.1    Merrill, J.2    Volokh, L.3    Bengel, F.M.4
  • 14
    • 4344684086 scopus 로고    scopus 로고
    • Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease
    • Parkash R, deKemp RA, Ruddy TD, Kitsikis A, Hart R, Beauchesne L et al. Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease. J Nucl Cardiol 2004;11:440-9.
    • (2004) J Nucl Cardiol , vol.11 , pp. 440-449
    • Parkash, R.1    DeKemp, R.A.2    Ruddy, T.D.3    Kitsikis, A.4    Hart, R.5    Beauchesne, L.6
  • 15
    • 33845329177 scopus 로고    scopus 로고
    • Relationship between non-invasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging
    • Schuijf JD, Wijns W, Jukema JW, Atsma DE, de Roos A, Lamb HJ et al. Relationship between non-invasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging. J Am Coll Cardiol 2006;48:2508-14.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2508-2514
    • Schuijf, J.D.1    Wijns, W.2    Jukema, J.W.3    Atsma, D.E.4    De Roos, A.5    Lamb, H.J.6
  • 16
    • 36148932978 scopus 로고    scopus 로고
    • Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging
    • Di Carli MF, Dorbala S, Curillova Z, Kwong RJ, Goldhaber SZ, Rybicki FJ et al. Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging. J Nucl Cardiol 2007;14:799-809.
    • (2007) J Nucl Cardiol , vol.14 , pp. 799-809
    • Di Carli, M.F.1    Dorbala, S.2    Curillova, Z.3    Kwong, R.J.4    Goldhaber, S.Z.5    Rybicki, F.J.6
  • 17
    • 2542451179 scopus 로고    scopus 로고
    • Prognostic value of gated myocardial perfusion SPECT
    • Shaw LJ, Iskandrian AE. Prognostic value of gated myocardial perfusion SPECT. J Nucl Cardiol 2004;11:171-85.
    • (2004) J Nucl Cardiol , vol.11 , pp. 171-185
    • Shaw, L.J.1    Iskandrian, A.E.2
  • 18
    • 0030711754 scopus 로고    scopus 로고
    • Incremental value of rubidium-82 positron emission tomography for prognostic assessment of known or suspected coronary artery disease
    • Marwick TH, Shan K, Patel S, Go RT, Lauer MS. Incremental value of rubidium-82 positron emission tomography for prognostic assessment of known or suspected coronary artery disease. Am J Cardiol 1997;80:865-70.
    • (1997) Am J Cardiol , vol.80 , pp. 865-870
    • Marwick, T.H.1    Shan, K.2    Patel, S.3    Go, R.T.4    Lauer, M.S.5
  • 19
    • 33747879780 scopus 로고    scopus 로고
    • What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography?
    • Shinaga K, Chow BJ, Williams K, Chen L, deKemp RA, Garrard L et al. What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography? J Am Coll Cardiol 2006;48:1029-39.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1029-1039
    • Shinaga, K.1    Chow, B.J.2    Williams, K.3    Chen, L.4    DeKemp, R.A.5    Garrard, L.6
  • 20
    • 67650112190 scopus 로고    scopus 로고
    • Incremental prognostic value of gated Rb-82 positron emission tomography myocardial perfusion imaging over clinical variables and rest LVEF
    • Dorbala S, Hachamovitch R, Curillova Z, Thomas D, Vangala D, Kwong RY et al. Incremental prognostic value of gated Rb-82 positron emission tomography myocardial perfusion imaging over clinical variables and rest LVEF. JACC Cardiovasc Imaging 2009;2:846-54.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 846-854
    • Dorbala, S.1    Hachamovitch, R.2    Curillova, Z.3    Thomas, D.4    Vangala, D.5    Kwong, R.Y.6
  • 21
    • 54449089322 scopus 로고    scopus 로고
    • Independent and incremental prognostic value of left ventricular ejection fraction determined by stress gated rubidium 82 PET imaging in patients with known or suspected coronary artery disease
    • Lertsburapa K, Ahlberg AW, Bateman TM, Katten D, Volker L, Cullom SJ et al. Independent and incremental prognostic value of left ventricular ejection fraction determined by stress gated rubidium 82 PET imaging in patients with known or suspected coronary artery disease. J Nucl Cardiol 2008;15:745-53.
    • (2008) J Nucl Cardiol , vol.15 , pp. 745-753
    • Lertsburapa, K.1    Ahlberg, A.W.2    Bateman, T.M.3    Katten, D.4    Volker, L.5    Cullom, S.J.6
  • 23
    • 0037080528 scopus 로고    scopus 로고
    • Prognostic role of myocardial blood flow impairment in idiopathic left ventricular dysfunction
    • Neglia D, Michelassi C, Trivieri MG, Sambuceti G, Giorgetti A, Pratali L et al. Prognostic role of myocardial blood flow impairment in idiopathic left ventricular dysfunction. Circulation 2002;105:186-93.
    • (2002) Circulation , vol.105 , pp. 186-193
    • Neglia, D.1    Michelassi, C.2    Trivieri, M.G.3    Sambuceti, G.4    Giorgetti, A.5    Pratali, L.6
  • 24
    • 33845382725 scopus 로고    scopus 로고
    • Coronary vasodilator reserve and Framingham risk scores in subjects at risk for coronary artery disease
    • Dorbala S, Hassan A, Heinonen T, Schelbert HR, Di Carli MF. Coronary vasodilator reserve and Framingham risk scores in subjects at risk for coronary artery disease. J Nucl Cardiol 2006;13:761-7.
    • (2006) J Nucl Cardiol , vol.13 , pp. 761-767
    • Dorbala, S.1    Hassan, A.2    Heinonen, T.3    Schelbert, H.R.4    Di Carli, M.F.5
  • 25
    • 67649385766 scopus 로고    scopus 로고
    • Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve
    • Herzog BA, Husmann L, Valenta I, Gaemperli O, Siegrist PT, Tay FM et al. Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve. J Am Coll Cardiol 2009;54:150-6.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 150-156
    • Herzog, B.A.1    Husmann, L.2    Valenta, I.3    Gaemperli, O.4    Siegrist, P.T.5    Tay, F.M.6
  • 26
    • 54549122949 scopus 로고    scopus 로고
    • Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: Results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial
    • Budoff MJ, Dowe D, Jollis JG, Gitter M, Sutherland J, Halamert E et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial. J Am Coll Cardiol 2008;52:1724-32.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1724-1732
    • Budoff, M.J.1    Dowe, D.2    Jollis, J.G.3    Gitter, M.4    Sutherland, J.5    Halamert, E.6
  • 28
    • 57449115879 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography coronary angiography: A prospective, multicenter, multi-vendor study
    • Meijboom WB, Meijs MF, Schuijf JD, Cramer MJ, Mollet NR, van Mieghem CA et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multi-vendor study. J Am Coll Cardiol 2008;52:2135-44.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 2135-2144
    • Meijboom, W.B.1    Meijs, M.F.2    Schuijf, J.D.3    Cramer, M.J.4    Mollet, N.R.5    Van Mieghem, C.A.6
  • 29
    • 77950297322 scopus 로고    scopus 로고
    • Integration of coronary anatomy and myocardial perfusion imaging
    • Blankstein R, Di Carli MF. Integration of coronary anatomy and myocardial perfusion imaging. Nat Rev Cardiol 2010;7:226-36.
    • (2010) Nat Rev Cardiol , vol.7 , pp. 226-236
    • Blankstein, R.1    Di Carli, M.F.2
  • 30
    • 44149085425 scopus 로고    scopus 로고
    • Reducing radiation dose in rest-stress cardiac PET/CT by single poststress cine CT for attenuation correction: Quantitative validation
    • DOI 10.2967/jnumed.107.049163
    • Gould KL, Pan T, Loghin C, Johnson NP, Sdringola S. Reducing radiation dose in rest-stress cardiac PET/CT by single poststress cine CT for attenuation correction: quantitative validation. J Nucl Med 2008;49:738-45. (Pubitemid 351717538)
    • (2008) Journal of Nuclear Medicine , vol.49 , Issue.5 , pp. 738-745
    • Gould, K.L.1    Pan, T.2    Loghin, C.3    Johnson, N.P.4    Sdringola, S.5
  • 31
    • 38349117091 scopus 로고    scopus 로고
    • CT-based attenuation correction in (82)Rb-myocardial perfusion PET-CT: Incidence of misalignment and effect on regional tracer distribution
    • Lautamaki R, Brown TL, Merrill J, Bengel FM. CT-based attenuation correction in (82)Rb-myocardial perfusion PET-CT: incidence of misalignment and effect on regional tracer distribution. Eur J Nucl Med Mol Imaging 2008;35:305-10.
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 305-310
    • Lautamaki, R.1    Brown, T.L.2    Merrill, J.3    Bengel, F.M.4
  • 33
    • 34447306296 scopus 로고    scopus 로고
    • Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: A definitive analysis of causes, consequences, and corrections
    • Gould KL, Pan T, Loghin C, Johnson NP, Guha A, Sdringola S. Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections. J Nucl Med 2007;48:1112-21.
    • (2007) J Nucl Med , vol.48 , pp. 1112-1121
    • Gould, K.L.1    Pan, T.2    Loghin, C.3    Johnson, N.P.4    Guha, A.5    Sdringola, S.6
  • 34
    • 33947374389 scopus 로고    scopus 로고
    • Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    • Goetze S, Wahl RL. Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT. J Nucl Cardiol 2007;14:200-6.
    • (2007) J Nucl Cardiol , vol.14 , pp. 200-206
    • Goetze, S.1    Wahl, R.L.2
  • 35
    • 43749118153 scopus 로고    scopus 로고
    • Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT
    • McQuaid SJ, Hutton BF. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT. Eur J Nucl Med Mol Imaging 2008;35:1117-23.
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 1117-1123
    • McQuaid, S.J.1    Hutton, B.F.2
  • 36
    • 57149095873 scopus 로고    scopus 로고
    • Comparison of myocardial perfusion 82Rb PET performed with CT- and transmission CT-based attenuation correction
    • Slomka PJ, Le Meunier L, Hayes SW, Acampa W, Oba M, Haemer GG et al. Comparison of myocardial perfusion 82Rb PET performed with CT- and transmission CT-based attenuation correction. J Nucl Med 2008;49:1992-8.
    • (2008) J Nucl Med , vol.49 , pp. 1992-1998
    • Slomka, P.J.1    Le Meunier, L.2    Hayes, S.W.3    Acampa, W.4    Oba, M.5    Haemer, G.G.6
  • 37
    • 0037062656 scopus 로고    scopus 로고
    • Imaging atherosclerotic plaque inflammation with [18F]-fluorodeoxyglucose positron emission tomography
    • Rudd JH, Warburton EA, Fryer TD, Jones HA, Clark JC, Antoun N et al. Imaging atherosclerotic plaque inflammation with [18F]-fluorodeoxyglucose positron emission tomography. Circulation 2002;105:2708-11.
    • (2002) Circulation , vol.105 , pp. 2708-2711
    • Rudd, J.H.1    Warburton, E.A.2    Fryer, T.D.3    Jones, H.A.4    Clark, J.C.5    Antoun, N.6
  • 39
    • 0031931187 scopus 로고    scopus 로고
    • Arterial calcification and not lumen stenosis is highly correlated with atherosclerotic plaque burden in humans: A histologic study of 723 coronary artery segments using nondecalcifying methodology
    • Sangiorgi G, Rumberger JA, Severson A, Edwards WD, Gregoire J, Fitzpatrick LA et al. Arterial calcification and not lumen stenosis is highly correlated with atherosclerotic plaque burden in humans: a histologic study of 723 coronary artery segments using nondecalcifying methodology. J Am Coll Cardiol 1998;31:126-33.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 126-133
    • Sangiorgi, G.1    Rumberger, J.A.2    Severson, A.3    Edwards, W.D.4    Gregoire, J.5    Fitzpatrick, L.A.6
  • 40
    • 41649101202 scopus 로고    scopus 로고
    • Interrelation of coronary calcification, myocardial ischemia, and outcomes in patients with intermediate likelihood of coronary artery disease: A combined positron emission tomography/computed tomography study
    • Schenker MP, Dorbala S, Hong EC, Rybicki FJ, Hachamovitch R, Kwong RY et al. Interrelation of coronary calcification, myocardial ischemia, and outcomes in patients with intermediate likelihood of coronary artery disease: a combined positron emission tomography/computed tomography study. Circulation 2008;117:1693-700.
    • (2008) Circulation , vol.117 , pp. 1693-1700
    • Schenker, M.P.1    Dorbala, S.2    Hong, E.C.3    Rybicki, F.J.4    Hachamovitch, R.5    Kwong, R.Y.6
  • 41
    • 34548542221 scopus 로고    scopus 로고
    • Computed tomography coronary angiography as an anatomic basis for risk stratification: Deja vu or something new?
    • Mahmarian JJ. Computed tomography coronary angiography as an anatomic basis for risk stratification: deja vu or something new? J Am Coll Cardiol 2007;50:1171-3.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1171-1173
    • Mahmarian, J.J.1
  • 42
    • 34249775027 scopus 로고    scopus 로고
    • Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT
    • Gaemperli O, Schepis T, Koepfli P, Valenta I, Soyka J, Leschka S et al. Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT. Eur J Nucl Med Mol Imaging 2007;34:1162-71.
    • (2007) Eur J Nucl Med Mol Imaging , vol.34 , pp. 1162-1171
    • Gaemperli, O.1    Schepis, T.2    Koepfli, P.3    Valenta, I.4    Soyka, J.5    Leschka, S.6
  • 45
    • 67650004076 scopus 로고    scopus 로고
    • Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography
    • Santana CA, Garcia EV, Faber TL, Sirineni GK, Esteves FP, Sanyal R et al. Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography. J Nucl Cardiol 2009;16:201-11.
    • (2009) J Nucl Cardiol , vol.16 , pp. 201-211
    • Santana, C.A.1    Garcia, E.V.2    Faber, T.L.3    Sirineni, G.K.4    Esteves, F.P.5    Sanyal, R.6
  • 46
    • 34249825903 scopus 로고    scopus 로고
    • Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography
    • Gaemperli O, Schepis T, Kalff V, Namdar M, Valenta I, Stefani L et al. Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography. Eur J Nucl Med Mol Imaging 2007;34:1097-106.
    • (2007) Eur J Nucl Med Mol Imaging , vol.34 , pp. 1097-1106
    • Gaemperli, O.1    Schepis, T.2    Kalff, V.3    Namdar, M.4    Valenta, I.5    Stefani, L.6
  • 48
    • 1642586981 scopus 로고    scopus 로고
    • Software approach to merging molecular with anatomic information
    • Slomka PJ. Software approach to merging molecular with anatomic information. J Nucl Med 2004;45(Suppl 1):36S-45S.
    • (2004) J Nucl Med , vol.45 , Issue.SUPPL. 1
    • Slomka, P.J.1
  • 49
    • 14244259420 scopus 로고    scopus 로고
    • Non-invasive multislice CT coronary imaging
    • Mollet NR, Cademartiri F, de Feyter PJ. Non-invasive multislice CT coronary imaging. Heart 2005;91:401-7.
    • (2005) Heart , vol.91 , pp. 401-407
    • Mollet, N.R.1    Cademartiri, F.2    De Feyter, P.J.3
  • 50
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates
    • Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M, Martinoff S et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 2006;113:1305-10.
    • (2006) Circulation , vol.113 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3    Huber, E.4    Zankl, M.5    Martinoff, S.6
  • 51
    • 43449084671 scopus 로고    scopus 로고
    • Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: A comparison with coronary angiography
    • Husmann L, Wiegand M, Valenta I, Gaemperli O, Schepis T, Siegrist PT et al. Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: a comparison with coronary angiography. Int J Cardiovasc Imaging 2008;24:511-8.
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 511-518
    • Husmann, L.1    Wiegand, M.2    Valenta, I.3    Gaemperli, O.4    Schepis, T.5    Siegrist, P.T.6
  • 52
    • 64949145381 scopus 로고    scopus 로고
    • Low-dose computed tomography coronary angiography and myocardial perfusion imaging: Cardiac hybrid imaging below 3mSv
    • Herzog BA, Husmann L, Landmesser U, Kaufmann PA. Low-dose computed tomography coronary angiography and myocardial perfusion imaging: cardiac hybrid imaging below 3mSv. Eur Heart J 2009;30:644.
    • (2009) Eur Heart J , vol.30 , pp. 644
    • Herzog, B.A.1    Husmann, L.2    Landmesser, U.3    Kaufmann, P.A.4
  • 53
    • 54449086666 scopus 로고    scopus 로고
    • Lowering radiation dose for integrated assessment of coronary morphology and physiology: First experience with step-and-shoot CT angiography in a rubidium 82 PET-CT protocol
    • Javadi M, Mahesh M, McBride G, Voicu C, Epley W, Merrill J et al. Lowering radiation dose for integrated assessment of coronary morphology and physiology: first experience with step-and-shoot CT angiography in a rubidium 82 PET-CT protocol. J Nucl Cardiol 2008;15:783-90.
    • (2008) J Nucl Cardiol , vol.15 , pp. 783-790
    • Javadi, M.1    Mahesh, M.2    McBride, G.3    Voicu, C.4    Epley, W.5    Merrill, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.