메뉴 건너뛰기




Volumn 15, Issue 6, 2008, Pages 783-790

Lowering radiation dose for integrated assessment of coronary morphology and physiology: First experience with step-and-shoot CT angiography in a rubidium 82 PET-CT protocol

Author keywords

computed tomography coronary angiography; Positron emission tomography computed tomography; radiation dose; rubidium 82

Indexed keywords

IODIXANOL; RUBIDIUM 82;

EID: 54449086666     PISSN: 10713581     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03007359     Document Type: Article
Times cited : (38)

References (20)
  • 1
    • 34147101153 scopus 로고    scopus 로고
    • New technology for noninvasive evaluation of coronary artery disease
    • Di Carli M.F., and Hachamovitch R. New technology for noninvasive evaluation of coronary artery disease. Circulation 115 (2007) 1464-1480
    • (2007) Circulation , vol.115 , pp. 1464-1480
    • Di Carli, M.F.1    Hachamovitch, R.2
  • 2
    • 33747136300 scopus 로고    scopus 로고
    • Roles of nuclear cardiology, cardiac computed tomography, and cardiac magnetic resonance: Noninvasive risk stratification and a conceptual framework for the selection of noninvasive imaging tests in patients with known or suspected coronary artery disease
    • Berman D.S., Hachamovitch R., Shaw L.J., Friedman J.D., Hayes S.W., Thomson L.E., et al. Roles of nuclear cardiology, cardiac computed tomography, and cardiac magnetic resonance: Noninvasive risk stratification and a conceptual framework for the selection of noninvasive imaging tests in patients with known or suspected coronary artery disease. J Nucl Med 47 (2006) 1107-1118
    • (2006) J Nucl Med , vol.47 , pp. 1107-1118
    • Berman, D.S.1    Hachamovitch, R.2    Shaw, L.J.3    Friedman, J.D.4    Hayes, S.W.5    Thomson, L.E.6
  • 3
    • 33845293410 scopus 로고    scopus 로고
    • Myocardial perfusion imaging and multidetector computed tomographic coronary angiography: Appropriate for all patients with suspected coronary artery disease?
    • Dorbala S., Hachamovitch R., and Di Carli M.F. Myocardial perfusion imaging and multidetector computed tomographic coronary angiography: Appropriate for all patients with suspected coronary artery disease?. J Am Coll Cardiol 48 (2006) 2515-2517
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2515-2517
    • Dorbala, S.1    Hachamovitch, R.2    Di Carli, M.F.3
  • 5
    • 38849143266 scopus 로고    scopus 로고
    • Hybrid PET/CT is greater than the sum of its parts
    • Di Carli M.F., and Hachamovitch R. Hybrid PET/CT is greater than the sum of its parts. J Nucl Cardiol 15 (2008) 118-122
    • (2008) J Nucl Cardiol , vol.15 , pp. 118-122
    • Di Carli, M.F.1    Hachamovitch, R.2
  • 6
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • Einstein A.J., Henzlova M.J., and Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298 (2007) 317-323
    • (2007) JAMA , vol.298 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 8
    • 33750547401 scopus 로고    scopus 로고
    • Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography
    • Hsieh J., Londt J., Vass M., Li J., Tang X., and Okerlund D. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys 33 (2006) 4236-4248
    • (2006) Med Phys , vol.33 , pp. 4236-4248
    • Hsieh, J.1    Londt, J.2    Vass, M.3    Li, J.4    Tang, X.5    Okerlund, D.6
  • 9
    • 38349134611 scopus 로고    scopus 로고
    • Feasibility of low-dose coronary CT angiography: First experience with prospective ECG-gating
    • Husmann L., Valenta I., Gaemperli O., Adda O., Treyer V., Wyss C.A., et al. Feasibility of low-dose coronary CT angiography: First experience with prospective ECG-gating. Eur Heart J 29 (2008) 191-197
    • (2008) Eur Heart J , vol.29 , pp. 191-197
    • Husmann, L.1    Valenta, I.2    Gaemperli, O.3    Adda, O.4    Treyer, V.5    Wyss, C.A.6
  • 10
    • 38349117091 scopus 로고    scopus 로고
    • CT-based attenuation correction in (82)Rb-myocardial perfusion PET-CT: Incidence of misalignment and effect on regional tracer distribution
    • Lautamäki R., Brown T.L., Merrill J., and Bengel F.M. CT-based attenuation correction in (82)Rb-myocardial perfusion PET-CT: Incidence of misalignment and effect on regional tracer distribution. Eur J Nucl Med Mol Imaging 35 (2008) 305-310
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 305-310
    • Lautamäki, R.1    Brown, T.L.2    Merrill, J.3    Bengel, F.M.4
  • 11
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
    • Austen W.G., Edwards J.E., Frye R.L., Gensini G.G., Gott V.L., Griffith L.S., et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51 (1975) 5-40
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3    Gensini, G.G.4    Gott, V.L.5    Griffith, L.S.6
  • 12
    • 34748902221 scopus 로고    scopus 로고
    • In vivo dosimetry for estimation of effective doses in multislice CT coronary angiography
    • de Denaro M., Bregant P., Severgnini M., and de Guarrini F. In vivo dosimetry for estimation of effective doses in multislice CT coronary angiography. Med Phys 34 (2007) 3705-3710
    • (2007) Med Phys , vol.34 , pp. 3705-3710
    • de Denaro, M.1    Bregant, P.2    Severgnini, M.3    de Guarrini, F.4
  • 13
    • 0028329726 scopus 로고
    • Comparison of two methods for assessing patient dose from computed tomography
    • Geleijns J., Van Unnik J.G., Zoetelief J., Zweers D., and Broerse J.J. Comparison of two methods for assessing patient dose from computed tomography. Br J Radiol 67 (1994) 360-365
    • (1994) Br J Radiol , vol.67 , pp. 360-365
    • Geleijns, J.1    Van Unnik, J.G.2    Zoetelief, J.3    Zweers, D.4    Broerse, J.J.5
  • 14
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    • Earls J.P., Berman E.L., Urban B.A., Curry C.A., Lane J.L., Jennings R.S., et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose. Radiology 246 (2008) 742-753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3    Curry, C.A.4    Lane, J.L.5    Jennings, R.S.6
  • 16
    • 23044484009 scopus 로고    scopus 로고
    • Integrated PET/CT for the assessment of coronary artery disease: A feasibility study
    • Namdar M., Hany T.F., Koepfli P., Siegrist P.T., Burger C., Wyss C.A., et al. Integrated PET/CT for the assessment of coronary artery disease: A feasibility study. J Nucl Med 46 (2005) 930-935
    • (2005) J Nucl Med , vol.46 , pp. 930-935
    • Namdar, M.1    Hany, T.F.2    Koepfli, P.3    Siegrist, P.T.4    Burger, C.5    Wyss, C.A.6
  • 17
    • 36148932978 scopus 로고    scopus 로고
    • Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging
    • Di Carli M.F., Dorbala S., Curillova Z., Kwong R.J., Goldhaber S.Z., Rybicki F.J., et al. Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging. J Nucl Cardiol 14 (2007) 799-809
    • (2007) J Nucl Cardiol , vol.14 , pp. 799-809
    • Di Carli, M.F.1    Dorbala, S.2    Curillova, Z.3    Kwong, R.J.4    Goldhaber, S.Z.5    Rybicki, F.J.6
  • 18
    • 38349154101 scopus 로고    scopus 로고
    • Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated (82)rubidium myocardial perfusion PET
    • Brown T.L., Merrill J., Volokh L., and Bengel F.M. Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated (82)rubidium myocardial perfusion PET. Eur J Nucl Med Mol Imaging 35 (2008) 336-342
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 336-342
    • Brown, T.L.1    Merrill, J.2    Volokh, L.3    Bengel, F.M.4
  • 19
    • 34247208691 scopus 로고    scopus 로고
    • Value of vasodilator left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: A 82Rb PET/CT study
    • Dorbala S., Vangala D., Sampson U., Limaye A., Kwong R., and Di Carli M.F. Value of vasodilator left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: A 82Rb PET/CT study. J Nucl Med 48 (2007) 349-358
    • (2007) J Nucl Med , vol.48 , pp. 349-358
    • Dorbala, S.1    Vangala, D.2    Sampson, U.3    Limaye, A.4    Kwong, R.5    Di Carli, M.F.6
  • 20
    • 34948891623 scopus 로고    scopus 로고
    • Physics of cardiac imaging with multiple-row detector CT
    • Mahesh M., and Cody D.D. Physics of cardiac imaging with multiple-row detector CT. Radiographics 27 (2007) 1495-1509
    • (2007) Radiographics , vol.27 , pp. 1495-1509
    • Mahesh, M.1    Cody, D.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.