Evaluation of the soft tissue biocompatibility of MgCa0.8 and surgical steel 316L in vivo: A comparative study in rabbits

Author keywords

[No Author keywords available]

Indexed keywords

ANTI-CD3; B LYMPHOCYTES; CELL TYPES; CELLULAR INFILTRATION; COMMONLY USED; COMPARATIVE STUDIES; FIBROUS TISSUE; FOLLOW UP; GEOMETRICAL CONFORMATION; GIANT CELLS; HAEMATOXYLIN; HUMORAL IMMUNITY; IMPLANT MATERIALS; IN-VIVO; MAGNESIUM-CALCIUM ALLOYS; OBSERVATION PERIOD; SCREW HEAD; SEMI-QUANTITATIVE; SOFT TISSUE; SYNOVIOCYTES; TIME-PERIODS; TISSUE NECROSIS;

EID: 77958149036     PISSN: 1475925X     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-9-63     Document Type: Article
Times cited : (76)

References (46)
  • 1
    • 0034448368 scopus 로고    scopus 로고
    • Unalloyed titanium for implants in bone surgery
    • Pohler OEM. Unalloyed titanium for implants in bone surgery. Injury 2000, 31(Suppl 4):7-13.
    • (2000) Injury , vol.31 , Issue.SUPPL 4 , pp. 7-13
    • Pohler, O.E.M.1
  • 2
    • 0034450007 scopus 로고    scopus 로고
    • Stainless steel in bone surgery
    • 10.1016/S0020-1383(00)80015-7, 11270076
    • Disegi JA, Eschbach L. Stainless steel in bone surgery. Injury 2000, 31(Suppl 4):2-6. 10.1016/S0020-1383(00)80015-7, 11270076.
    • (2000) Injury , vol.31 , Issue.SUPPL 4 , pp. 2-6
    • Disegi, J.A.1    Eschbach, L.2
  • 3
    • 0038052037 scopus 로고    scopus 로고
    • Stress shielding and bone resorption in shoulder arthroplasty
    • 10.1067/mse.2003.22, 12610484
    • Nagels J, Stokdijk M, Rozing PM. Stress shielding and bone resorption in shoulder arthroplasty. J Shoulder Elbow Surg 2003, 12:35-39. 10.1067/mse.2003.22, 12610484.
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 35-39
    • Nagels, J.1    Stokdijk, M.2    Rozing, P.M.3
  • 4
    • 0035108321 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopaedic implants
    • Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 2001, 83-A:428-436.
    • (2001) J Bone Joint Surg Am , vol.83 A , pp. 428-436
    • Hallab, N.1    Merritt, K.2    Jacobs, J.J.3
  • 5
    • 0028918524 scopus 로고
    • Biodegradable implants in traumatology: a review on the state-of-the-art
    • 10.1007/BF00443385, 7619632
    • Hofmann GO. Biodegradable implants in traumatology: a review on the state-of-the-art. Arch Orthop Trauma Surg 1995, 114:123-132. 10.1007/BF00443385, 7619632.
    • (1995) Arch Orthop Trauma Surg , vol.114 , pp. 123-132
    • Hofmann, G.O.1
  • 6
    • 49949095955 scopus 로고    scopus 로고
    • Biomaterials in orthopaedics
    • 10.1098/rsif.2008.0151, 2706047, 18667387
    • Navarro M, Michiardi A, Castaño O, Planell JA. Biomaterials in orthopaedics. J R Soc Interface 2008, 5:1137-1158. 10.1098/rsif.2008.0151, 2706047, 18667387.
    • (2008) J R Soc Interface , vol.5 , pp. 1137-1158
    • Navarro, M.1    Michiardi, A.2    Castaño, O.3    Planell, J.A.4
  • 7
    • 84942386047 scopus 로고
    • Absorbable Metal in Bone Surgery
    • McBride ED. Absorbable Metal in Bone Surgery. J Am Med Assoc 1938, 111:2464-2467.
    • (1938) J Am Med Assoc , vol.111 , pp. 2464-2467
    • McBride, E.D.1
  • 8
    • 11144261578 scopus 로고
    • Le Matériel Métallique Résorbable En Chirurgie Osseuse
    • Verbrugge J. Le Matériel Métallique Résorbable En Chirurgie Osseuse. La Press Med 1934, 23:460-465.
    • (1934) La Press Med , vol.23 , pp. 460-465
    • Verbrugge, J.1
  • 9
    • 33747740694 scopus 로고    scopus 로고
    • Are resorbable implants about to become a reality?
    • 10.1017/S1047951106000011, 16553970
    • Peuster M, Beerbaum P, Bach FW, Hauser H. Are resorbable implants about to become a reality?. Cardiol Young 2006, 16:107-116. 10.1017/S1047951106000011, 16553970.
    • (2006) Cardiol Young , vol.16 , pp. 107-116
    • Peuster, M.1    Beerbaum, P.2    Bach, F.W.3    Hauser, H.4
  • 10
    • 33847621267 scopus 로고    scopus 로고
    • Control of biodegradation of biocompatable magnesium alloys
    • Song G. Control of biodegradation of biocompatable magnesium alloys. Corros Sci 2007, 49:1696-1701.
    • (2007) Corros Sci , vol.49 , pp. 1696-1701
    • Song, G.1
  • 11
    • 70350466588 scopus 로고    scopus 로고
    • MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
    • 10.1038/nmat2542, 19783982
    • Zberg B, Uggowitzer PJ, Löffler JF. MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants. Nat Mater 2009, 8:887-891. 10.1038/nmat2542, 19783982.
    • (2009) Nat Mater , vol.8 , pp. 887-891
    • Zberg, B.1    Uggowitzer, P.J.2    Löffler, J.F.3
  • 12
    • 77951531120 scopus 로고    scopus 로고
    • In vivo evaluation of biodegradable magnesium alloy bone implant in the first 6 months implantation
    • Zhang E, Xu L, Yu G, Pan F, Yang K. In vivo evaluation of biodegradable magnesium alloy bone implant in the first 6 months implantation. J Biomed Mater Res A 2009, 90:882-893.
    • (2009) J Biomed Mater Res A , vol.90 , pp. 882-893
    • Zhang, E.1    Xu, L.2    Yu, G.3    Pan, F.4    Yang, K.5
  • 13
    • 28844481103 scopus 로고    scopus 로고
    • Magnesium and its alloys as orthopedic biomaterials: a review
    • 10.1016/j.biomaterials.2005.10.003, 16246414
    • Staiger MP, Pietak AM, Huadmai J, Dias G. Magnesium and its alloys as orthopedic biomaterials: a review. Biomaterials 2006, 27:1728-1734. 10.1016/j.biomaterials.2005.10.003, 16246414.
    • (2006) Biomaterials , vol.27 , pp. 1728-1734
    • Staiger, M.P.1    Pietak, A.M.2    Huadmai, J.3    Dias, G.4
  • 14
    • 0033135945 scopus 로고    scopus 로고
    • Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-L-lactide (PLLA): Part I. Basic characteristics
    • 10.1016/S0142-9612(98)00241-5, 10226712
    • Shikinami Y, Okuno M. Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-L-lactide (PLLA): Part I. Basic characteristics. Biomaterials 1999, 20:859-877. 10.1016/S0142-9612(98)00241-5, 10226712.
    • (1999) Biomaterials , vol.20 , pp. 859-877
    • Shikinami, Y.1    Okuno, M.2
  • 15
    • 0343247711 scopus 로고    scopus 로고
    • Biodegradation and biocompatibility of PLA and PLGA microspheres
    • 10.1016/S0169-409X(97)00048-3, 10837562
    • Shive A. Biodegradation and biocompatibility of PLA and PLGA microspheres. Adv Drug Deliv Rev 1997, 28:5-24. 10.1016/S0169-409X(97)00048-3, 10837562.
    • (1997) Adv Drug Deliv Rev , vol.28 , pp. 5-24
    • Shive, A.1
  • 16
    • 0016938496 scopus 로고
    • The influence of surface chemistry on implant interface histology: a theoretical basis for implant materials selection
    • 10.1002/jbm.820100202, 1254612
    • Clark AE, Hench LL, Paschall HA. The influence of surface chemistry on implant interface histology: a theoretical basis for implant materials selection. J Biomed Mater Res 1976, 10:161-174. 10.1002/jbm.820100202, 1254612.
    • (1976) J Biomed Mater Res , vol.10 , pp. 161-174
    • Clark, A.E.1    Hench, L.L.2    Paschall, H.A.3
  • 17
    • 56349103543 scopus 로고    scopus 로고
    • On the biodegradation performance of an Mg-Y-RE alloy with various surface conditions in simulated body fluid
    • 10.1016/j.actbio.2008.07.034, 18762463
    • Hänzi AC, Gunde P, Schinhammer M, Uggowitzer PJ. On the biodegradation performance of an Mg-Y-RE alloy with various surface conditions in simulated body fluid. Acta Biomater 2009, 5:162-171. 10.1016/j.actbio.2008.07.034, 18762463.
    • (2009) Acta Biomater , vol.5 , pp. 162-171
    • Hänzi, A.C.1    Gunde, P.2    Schinhammer, M.3    Uggowitzer, P.J.4
  • 18
    • 34249010154 scopus 로고    scopus 로고
    • Biodegradable magnesium scaffolds: Part 1: appropriate inflammatory response
    • Witte F, Ulrich H, Rudert M, Willbold E. Biodegradable magnesium scaffolds: Part 1: appropriate inflammatory response. J Biomed Mater Res A 2007, 81:748-756.
    • (2007) J Biomed Mater Res A , vol.81 , pp. 748-756
    • Witte, F.1    Ulrich, H.2    Rudert, M.3    Willbold, E.4
  • 19
    • 11144301699 scopus 로고    scopus 로고
    • In vivo corrosion of four magnesium alloys and the associated bone response
    • 10.1016/j.biomaterials.2004.09.049, 15621246
    • Witte F, Kaese V, Haferkamp H, Switzer E, Meyer-Lindenberg A, Wirth CJ, Windhagen H. In vivo corrosion of four magnesium alloys and the associated bone response. Biomaterials 2005, 26:3557-3563. 10.1016/j.biomaterials.2004.09.049, 15621246.
    • (2005) Biomaterials , vol.26 , pp. 3557-3563
    • Witte, F.1    Kaese, V.2    Haferkamp, H.3    Switzer, E.4    Meyer-Lindenberg, A.5    Wirth, C.J.6    Windhagen, H.7
  • 21
    • 77950219251 scopus 로고    scopus 로고
    • Development and biocompatibility of a novel corrodible fluoride-coated magnesium-calcium alloy with improved degradation kinetics and adequate mechanical properties for cardiovascular applications
    • Drynda A, Hassel T, Hoehn R, Perz A, Bach F, Peuster M. Development and biocompatibility of a novel corrodible fluoride-coated magnesium-calcium alloy with improved degradation kinetics and adequate mechanical properties for cardiovascular applications. J Biomed Mater Res A 2010, 93:763-775.
    • (2010) J Biomed Mater Res A , vol.93 , pp. 763-775
    • Drynda, A.1    Hassel, T.2    Hoehn, R.3    Perz, A.4    Bach, F.5    Peuster, M.6
  • 22
    • 38349153562 scopus 로고    scopus 로고
    • The development of binary Mg-Ca alloys for use as biodegradable materials within bone
    • 10.1016/j.biomaterials.2007.12.021, 18191191
    • Li Z, Gu X, Lou S, Zheng Y. The development of binary Mg-Ca alloys for use as biodegradable materials within bone. Biomaterials 2008, 29:1329-1344. 10.1016/j.biomaterials.2007.12.021, 18191191.
    • (2008) Biomaterials , vol.29 , pp. 1329-1344
    • Li, Z.1    Gu, X.2    Lou, S.3    Zheng, Y.4
  • 23
    • 62549120753 scopus 로고    scopus 로고
    • Influence of different surface machining treatments of resorbable magnesium alloy implants on degradation - EDX-analysis and histology results
    • von der H, Rechenberg von B, Bormann D, Lucas A, Meyer-Lindenberg A. Influence of different surface machining treatments of resorbable magnesium alloy implants on degradation - EDX-analysis and histology results. Mat-wiss u Werkstofftech 2009, 40:88-93.
    • (2009) Mat-wiss u Werkstofftech , vol.40 , pp. 88-93
    • von der, H.1    Rechenberg von, B.2    Bormann, D.3    Lucas, A.4    Meyer-Lindenberg, A.5
  • 24
    • 62549089681 scopus 로고    scopus 로고
    • Comparison of the resorbable magnesium alloys LAE442 und MgCa0.8 concerning their mechanical properties, their progress of degradation and the bone-implant-contact after 12 months implantation duration in a rabbit model
    • Thomann M, Krause C, Bormann D, von der H, Windhagen H, Meyer-Lindenberg A. Comparison of the resorbable magnesium alloys LAE442 und MgCa0.8 concerning their mechanical properties, their progress of degradation and the bone-implant-contact after 12 months implantation duration in a rabbit model. Mat-wiss u Werkstofftech 2009, 40:82-87.
    • (2009) Mat-wiss u Werkstofftech , vol.40 , pp. 82-87
    • Thomann, M.1    Krause, C.2    Bormann, D.3    von der, H.4    Windhagen, H.5    Meyer-Lindenberg, A.6
  • 25
    • 67049156800 scopus 로고    scopus 로고
    • Influence of Different Surface Machining Treatments of Magnesium-based Resorbable Implants on the Degradation Behavior in Rabbits
    • von der H, Bormann D, Lucas A, Denkena B, Hackenbroich C, Meyer-Lindenberg A. Influence of Different Surface Machining Treatments of Magnesium-based Resorbable Implants on the Degradation Behavior in Rabbits. Adv Eng Mater 2009, 11:B47-B54.
    • (2009) Adv Eng Mater , vol.11
    • von der, H.1    Bormann, D.2    Lucas, A.3    Denkena, B.4    Hackenbroich, C.5    Meyer-Lindenberg, A.6
  • 26
    • 0027300658 scopus 로고
    • Detection of T and B cells in many animal species using cross-reactive anti-peptide antibodies
    • Jones M, Cordell JL, Beyers AD, Tse AG, Mason DY. Detection of T and B cells in many animal species using cross-reactive anti-peptide antibodies. J Immunol 1993, 150:5429-5435.
    • (1993) J Immunol , vol.150 , pp. 5429-5435
    • Jones, M.1    Cordell, J.L.2    Beyers, A.D.3    Tse, A.G.4    Mason, D.Y.5
  • 27
    • 77953081471 scopus 로고    scopus 로고
    • In vivo corrosion and corrosion protection of magnesium alloy LAE442
    • 10.1016/j.actbio.2009.10.012, 19822226
    • Witte F, Fischer J, Nellesen J, Vogt C, Vogt J, Donath T, Beckmann F. In vivo corrosion and corrosion protection of magnesium alloy LAE442. Acta Biomater 2010, 6:1792-1799. 10.1016/j.actbio.2009.10.012, 19822226.
    • (2010) Acta Biomater , vol.6 , pp. 1792-1799
    • Witte, F.1    Fischer, J.2    Nellesen, J.3    Vogt, C.4    Vogt, J.5    Donath, T.6    Beckmann, F.7
  • 28
    • 0033196585 scopus 로고    scopus 로고
    • Corrosion mechanisms of magnesium alloys
    • Song G, Atrens A. Corrosion mechanisms of magnesium alloys. Adv Eng Mater 1999, 1:11-33.
    • (1999) Adv Eng Mater , vol.1 , pp. 11-33
    • Song, G.1    Atrens, A.2
  • 31
    • 0019424377 scopus 로고
    • The formation of a structure with the features of synovial lining by subcutaneous injection of air: an in vivo tissue culture system
    • 10.1002/path.1711340205, 7019400
    • Edwards JC, Sedgwick AD, Willoughby DA. The formation of a structure with the features of synovial lining by subcutaneous injection of air: an in vivo tissue culture system. J Pathol 1981, 134:147-156. 10.1002/path.1711340205, 7019400.
    • (1981) J Pathol , vol.134 , pp. 147-156
    • Edwards, J.C.1    Sedgwick, A.D.2    Willoughby, D.A.3
  • 32
    • 0020576705 scopus 로고
    • The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis
    • Goldring SR, Schiller AL, Roelke M, Rourke CM, O'Neil DA, Harris WH. The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J Bone Joint Surg Am 1983, 65:575-584.
    • (1983) J Bone Joint Surg Am , vol.65 , pp. 575-584
    • Goldring, S.R.1    Schiller, A.L.2    Roelke, M.3    Rourke, C.M.4    O'Neil, D.A.5    Harris, W.H.6
  • 33
    • 0029894819 scopus 로고    scopus 로고
    • Capsular synovial metaplasia as a common response to both textured and smooth implants
    • 10.1097/00006534-199606000-00017, 8643727
    • Ko CY, Ahn CY, Ko J, Chopra W, Shaw WW. Capsular synovial metaplasia as a common response to both textured and smooth implants. Plast Reconstr Surg 1996, 97:1427-1435. 10.1097/00006534-199606000-00017, 8643727.
    • (1996) Plast Reconstr Surg , vol.97 , pp. 1427-1435
    • Ko, C.Y.1    Ahn, C.Y.2    Ko, J.3    Chopra, W.4    Shaw, W.W.5
  • 35
    • 0028532970 scopus 로고
    • Comparison of the tissue reaction to implants made of a beta titanium alloy and pure titanium. Experimental study on rabbits
    • Ungersböck A, Perren SM, Pohler O. Comparison of the tissue reaction to implants made of a beta titanium alloy and pure titanium. Experimental study on rabbits. J Mater Sci Mater Med 1994, 5:788-792.
    • (1994) J Mater Sci Mater Med , vol.5 , pp. 788-792
    • Ungersböck, A.1    Perren, S.M.2    Pohler, O.3
  • 36
    • 0015683182 scopus 로고
    • Changes in nonosseous tissue adjacent to titanium implants
    • 10.1002/jbm.820070607, 4589049
    • Meachim G, Williams DF. Changes in nonosseous tissue adjacent to titanium implants. J Biomed Mater Res 1973, 7:555-572. 10.1002/jbm.820070607, 4589049.
    • (1973) J Biomed Mater Res , vol.7 , pp. 555-572
    • Meachim, G.1    Williams, D.F.2
  • 37
    • 0027723269 scopus 로고
    • Strategies to affect bone remodeling: osteointegration
    • LeGeros RZ, Craig RG. Strategies to affect bone remodeling: osteointegration. J Bone Miner Res 1993, 8(Suppl 2):S583-S596.
    • (1993) J Bone Miner Res , vol.8 , Issue.SUPPL 2
    • LeGeros, R.Z.1    Craig, R.G.2
  • 38
    • 0030130652 scopus 로고    scopus 로고
    • Evaluation of soft tissue reactions at the interface of titanium limited contact dynamic compression plate implants with different surface treatments: an experimental sheep study
    • 10.1016/0142-9612(96)81417-7, 8730964
    • Ungersböck A, Pohler OE, Perren SM. Evaluation of soft tissue reactions at the interface of titanium limited contact dynamic compression plate implants with different surface treatments: an experimental sheep study. Biomaterials 1996, 17:797-806. 10.1016/0142-9612(96)81417-7, 8730964.
    • (1996) Biomaterials , vol.17 , pp. 797-806
    • Ungersböck, A.1    Pohler, O.E.2    Perren, S.M.3
  • 39
    • 40849094515 scopus 로고    scopus 로고
    • Foreign body reaction to biomaterials
    • 10.1016/j.smim.2007.11.004, 2327202, 18162407
    • Anderson JM, Rodriguez A, Chang DT. Foreign body reaction to biomaterials. Semin Immunol 2007, 20:86-100. 10.1016/j.smim.2007.11.004, 2327202, 18162407.
    • (2007) Semin Immunol , vol.20 , pp. 86-100
    • Anderson, J.M.1    Rodriguez, A.2    Chang, D.T.3
  • 40
    • 43949164802 scopus 로고
    • Chapter 4 - Mechanisms of inflammation and infection with implanted devices
    • Anderson JM. Chapter 4 - Mechanisms of inflammation and infection with implanted devices. Cardiovasc Pathol 1993, 2:33S-41S.
    • (1993) Cardiovasc Pathol , vol.2
    • Anderson, J.M.1
  • 41
    • 0034446599 scopus 로고    scopus 로고
    • Bioresorbable polymers in trauma and bone surgery
    • 10.1016/S0020-1383(00)80020-0, 11270078
    • Gogolewski S. Bioresorbable polymers in trauma and bone surgery. Injury 2000, 31:28-32. 10.1016/S0020-1383(00)80020-0, 11270078.
    • (2000) Injury , vol.31 , pp. 28-32
    • Gogolewski, S.1
  • 42
    • 0026518970 scopus 로고
    • Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures
    • Böstman OM. Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin Orthop Relat Res 1992, 278:193-199.
    • (1992) Clin Orthop Relat Res , vol.278 , pp. 193-199
    • Böstman, O.M.1
  • 43
    • 0034114212 scopus 로고    scopus 로고
    • Biodegradable implants in sports medicine: the biological base
    • 10.1016/S0749-8063(00)90055-0, 10750011
    • Weiler A, Hoffmann RF, Stähelin AC, Helling HJ, Südkamp NP. Biodegradable implants in sports medicine: the biological base. Arthroscopy 2000, 16:305-321. 10.1016/S0749-8063(00)90055-0, 10750011.
    • (2000) Arthroscopy , vol.16 , pp. 305-321
    • Weiler, A.1    Hoffmann, R.F.2    Stähelin, A.C.3    Helling, H.J.4    Südkamp, N.P.5
  • 44
    • 0026575586 scopus 로고
    • Osteosynthesis of distal radius fractures with biodegradable fracture rods. Results of two years follow-up
    • Hoffmann R, Krettek C, Hetkämper A, Haas N, Tscherne H. Osteosynthesis of distal radius fractures with biodegradable fracture rods. Results of two years follow-up. Unfallchirurg 1992, 95:99-105.
    • (1992) Unfallchirurg , vol.95 , pp. 99-105
    • Hoffmann, R.1    Krettek, C.2    Hetkämper, A.3    Haas, N.4    Tscherne, H.5
  • 45
    • 0028290352 scopus 로고
    • Molecular control of B lymphocyte growth and differentiation
    • 10.1002/stem.5530120304, 7521239
    • Banchereau J, Brière F, Liu YJ, Rousset F. Molecular control of B lymphocyte growth and differentiation. Stem Cells 1994, 12:278-288. 10.1002/stem.5530120304, 7521239.
    • (1994) Stem Cells , vol.12 , pp. 278-288
    • Banchereau, J.1    Brière, F.2    Liu, Y.J.3    Rousset, F.4
  • 46
    • 0037209882 scopus 로고    scopus 로고
    • Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones
    • 10.1016/S0142-9612(02)00312-5, 12419625
    • Voggenreiter G, Leiting S, Brauer H, Leiting P, Majetschak M, Bardenheuer M, Obertacke U. Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones. Biomaterials 2003, 24:247-254. 10.1016/S0142-9612(02)00312-5, 12419625.
    • (2003) Biomaterials , vol.24 , pp. 247-254
    • Voggenreiter, G.1    Leiting, S.2    Brauer, H.3    Leiting, P.4    Majetschak, M.5    Bardenheuer, M.6    Obertacke, U.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.