메뉴 건너뛰기




Volumn 24, Issue 2, 2003, Pages 247-254

Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones

Author keywords

Immunohistochemistry; Internal fixation; Long bones; Stainless steel; Tissue reaction; Titanium

Indexed keywords

BIOCOMPATIBILITY; BONE; CELLS; IMPLANTS (SURGICAL); PATIENT MONITORING; STAINLESS STEEL; TISSUE; TITANIUM PLATING;

EID: 0037209882     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(02)00312-5     Document Type: Article
Times cited : (107)

References (41)
  • 1
    • 0015683182 scopus 로고
    • Changes in nonosseous tissue adjactent to titanium implants
    • Meachim G., Williams D.F. Changes in nonosseous tissue adjactent to titanium implants. J Biomed Mater Res. 7:1973;555-572.
    • (1973) J Biomed Mater Res , vol.7 , pp. 555-572
    • Meachim, G.1    Williams, D.F.2
  • 2
    • 0029245311 scopus 로고
    • Immunocompetent cells adjacent to stainless steel and titanium miniplates and screws
    • Torgersen S., Moe G., Jonsson R. Immunocompetent cells adjacent to stainless steel and titanium miniplates and screws. Eur J Oral Sci. 103:1995;46-54.
    • (1995) Eur J Oral Sci , vol.103 , pp. 46-54
    • Torgersen, S.1    Moe, G.2    Jonsson, R.3
  • 3
    • 0029787081 scopus 로고    scopus 로고
    • Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures
    • Katou F., Andoh N., Motegi K., Nagura H. Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures. J Cranio-Maxillofac Surg. 24:1996;155-162.
    • (1996) J Cranio-Maxillofac Surg , vol.24 , pp. 155-162
    • Katou, F.1    Andoh, N.2    Motegi, K.3    Nagura, H.4
  • 4
    • 0031051493 scopus 로고    scopus 로고
    • Human monocyte/macrophage respons to cobalt-chromium corrosion products and titanium particles in patients with total joint replacement
    • Lee S.H., Brennan F.R., Jacobs J.J., Urban R.M., Ragasa D.R., Glant T.T. Human monocyte/macrophage respons to cobalt-chromium corrosion products and titanium particles in patients with total joint replacement. J Orthop Res. 15:1997;40-49.
    • (1997) J Orthop Res , vol.15 , pp. 40-49
    • Lee, S.H.1    Brennan, F.R.2    Jacobs, J.J.3    Urban, R.M.4    Ragasa, D.R.5    Glant, T.T.6
  • 7
    • 0001251725 scopus 로고
    • Characterization of trace ion release from embedded metal implants in the rabbit
    • Ferguson A.B., Akahoshi Y., Laing P.G., Hodge E.S. Characterization of trace ion release from embedded metal implants in the rabbit. J Bone Joint Surg. 44:1962;317-336.
    • (1962) J Bone Joint Surg , vol.44 , pp. 317-336
    • Ferguson, A.B.1    Akahoshi, Y.2    Laing, P.G.3    Hodge, E.S.4
  • 8
    • 0029997499 scopus 로고    scopus 로고
    • Immune response to synthetic materials - Sensitization of patients receiving orthopaedic implants
    • Merrit K., Rodrigo J.J. Immune response to synthetic materials - sensitization of patients receiving orthopaedic implants. Clin Orthop. 326:1996;71-79.
    • (1996) Clin Orthop , vol.326 , pp. 71-79
    • Merrit, K.1    Rodrigo, J.J.2
  • 12
    • 0026333014 scopus 로고
    • The concept of biological plating using the limited contact dynamic compression plate
    • Perren S.M. The concept of biological plating using the limited contact dynamic compression plate. Injury. 23(Suppl 1):1991;1-41.
    • (1991) Injury , vol.23 , Issue.SUPPL. 1 , pp. 1-41
    • Perren, S.M.1
  • 14
    • 0030064233 scopus 로고    scopus 로고
    • Human macrophage response to retrieved titanium alloy particles in vitro
    • Maloney W.J., James R.E., Smith R.L. Human macrophage response to retrieved titanium alloy particles in vitro. Clin Orthop. 322:1996;268-278.
    • (1996) Clin Orthop , vol.322 , pp. 268-278
    • Maloney, W.J.1    James, R.E.2    Smith, R.L.3
  • 15
    • 0034063637 scopus 로고    scopus 로고
    • Human osteoblast-like cells phagocytose metal particles and express the macrophage marker CD68 in vitro
    • Heinemann D.E.H., Lohmann C., Siggelkow H., Alves F., Engel I., Köster G. Human osteoblast-like cells phagocytose metal particles and express the macrophage marker CD68 in vitro. J Bone Joint Surg. 82-B:2000;283-289.
    • (2000) J Bone Joint Surg , vol.82 B , pp. 283-289
    • Heinemann, D.E.H.1    Lohmann, C.2    Siggelkow, H.3    Alves, F.4    Engel, I.5    Köster, G.6
  • 16
    • 0016968013 scopus 로고
    • The pathology of the joint tissues and its clinical relevance in prosthesis failure
    • Mirra J.M., Amstutz H.C., Matos M., Gold R. The pathology of the joint tissues and its clinical relevance in prosthesis failure. Clin Orthop. 117:1976;221-240.
    • (1976) Clin Orthop , vol.117 , pp. 221-240
    • Mirra, J.M.1    Amstutz, H.C.2    Matos, M.3    Gold, R.4
  • 17
    • 0021674466 scopus 로고
    • Immunocytochemical characterization of monoclonal anti-HLA-DR antibodies
    • C.M. Steel. Sussex: Wiley
    • Ghosh A.K., Gatter K.C., Mason D.Y. Immunocytochemical characterization of monoclonal anti-HLA-DR antibodies. Steel C.M. Disease markers. 1984;223-233 Wiley, Sussex.
    • (1984) Disease markers , pp. 223-233
    • Ghosh, A.K.1    Gatter, K.C.2    Mason, D.Y.3
  • 19
    • 0023147355 scopus 로고
    • Foreign body reaction to polymeric debris following total hip arthroplasty
    • Maguire J.K., Coscia M.F., Lynch M.H. Foreign body reaction to polymeric debris following total hip arthroplasty. Clin Orthop. 216:1987;213-223.
    • (1987) Clin Orthop , vol.216 , pp. 213-223
    • Maguire, J.K.1    Coscia, M.F.2    Lynch, M.H.3
  • 20
    • 0026004023 scopus 로고
    • Immunopathological response to loose cementless acetabular components
    • Santavitra S., Konttinen Y.T., Hoikka V., Eskola A. Immunopathological response to loose cementless acetabular components. J Bone Joint Surg. 73-B:1991;38-42.
    • (1991) J Bone Joint Surg , vol.73 B , pp. 38-42
    • Santavitra, S.1    Konttinen, Y.T.2    Hoikka, V.3    Eskola, A.4
  • 21
    • 0027483508 scopus 로고
    • T-lymphocytes and titanium aluminium vanadium (TiAlV) alloy: Evidence for immunological events associated with debris deposition
    • Lalor P.A., Revell T.A. T-lymphocytes and titanium aluminium vanadium (TiAlV) alloy. evidence for immunological events associated with debris deposition Clin Mater. 12:1993;57-62.
    • (1993) Clin Mater , vol.12 , pp. 57-62
    • Lalor, P.A.1    Revell, T.A.2
  • 22
    • 0029047766 scopus 로고
    • Immunohistochemical study of the soft tissue around long-term skin-penetrating titanium implants
    • Holgers K.M., Thomsen P., Tjellstrom A., Bjursten L.M. Immunohistochemical study of the soft tissue around long-term skin-penetrating titanium implants. Biomaterials. 16:1995;611-616.
    • (1995) Biomaterials , vol.16 , pp. 611-616
    • Holgers, K.M.1    Thomsen, P.2    Tjellstrom, A.3    Bjursten, L.M.4
  • 23
    • 0025689518 scopus 로고
    • Tissue response in relation to type of wear particles around failed hip arthroplasties
    • Howie D.W. Tissue response in relation to type of wear particles around failed hip arthroplasties. J Arthroplasty. 5:1990;337-348.
    • (1990) J Arthroplasty , vol.5 , pp. 337-348
    • Howie, D.W.1
  • 24
    • 0025642529 scopus 로고
    • Cementless total joint arthroplasty prostheses with titanium alloy articular surfaces. A human retrieval analysis
    • Nasser S., Campbell P.A., Kilgus D., Kossovsky N., Amstutz C. Cementless total joint arthroplasty prostheses with titanium alloy articular surfaces. A human retrieval analysis. Clin Orthop. 261:1990;171-185.
    • (1990) Clin Orthop , vol.261 , pp. 171-185
    • Nasser, S.1    Campbell, P.A.2    Kilgus, D.3    Kossovsky, N.4    Amstutz, C.5
  • 25
    • 0035256195 scopus 로고    scopus 로고
    • In vitro reaction to orthopaedic biomaterials by macrophages and lymphocytes isolated from patients undergoing revision surgery
    • Trindade M.C., Lind M., Sun D., Schurman D.J., Goodman S.B., Smith R.L. In vitro reaction to orthopaedic biomaterials by macrophages and lymphocytes isolated from patients undergoing revision surgery. Biomaterials. 22:2001;253-259.
    • (2001) Biomaterials , vol.22 , pp. 253-259
    • Trindade, M.C.1    Lind, M.2    Sun, D.3    Schurman, D.J.4    Goodman, S.B.5    Smith, R.L.6
  • 26
    • 0033863420 scopus 로고    scopus 로고
    • Induction of interleukin-6 release in human osteoblast-like cells exposed to titanium particles in vitro
    • Shida J., Trindade M.C., Goodman S.B., Schurman D.J., Smith R.L. Induction of interleukin-6 release in human osteoblast-like cells exposed to titanium particles in vitro. Calcif Tissue Int. 67:2000;151-155.
    • (2000) Calcif Tissue Int , vol.67 , pp. 151-155
    • Shida, J.1    Trindade, M.C.2    Goodman, S.B.3    Schurman, D.J.4    Smith, R.L.5
  • 27
    • 0032955730 scopus 로고    scopus 로고
    • Induction of macrophage C-C-chemokine expression by titanium alloy and bone cement particles
    • Nakashima Y., Sun D.H., Trindade M.C.D., Chun L.E., Song Y., Goodman S.B.et al. Induction of macrophage C-C-chemokine expression by titanium alloy and bone cement particles. J Bone Joint Surg. 81-B:1999;155-162.
    • (1999) J Bone Joint Surg , vol.81 B , pp. 155-162
    • Nakashima, Y.1    Sun, D.H.2    Trindade, M.C.D.3    Chun, L.E.4    Song, Y.5    Goodman, S.B.6
  • 28
    • 0025886919 scopus 로고
    • Black staining around titanium alloy prostheses - An orthopaedic enigma
    • Scales J.T. Black staining around titanium alloy prostheses - an orthopaedic enigma. J Bone Joint Surg. 73-B(4):1991;534-536.
    • (1991) J Bone Joint Surg , vol.73 B , Issue.4 , pp. 534-536
    • Scales, J.T.1
  • 29
    • 72849160309 scopus 로고
    • The ionization of metal implants in living tissues
    • Ferguson A.B., Laing P.G., Hodge E.S. The ionization of metal implants in living tissues. J Bone Joint Surg. 42:1960;77-90.
    • (1960) J Bone Joint Surg , vol.42 , pp. 77-90
    • Ferguson, A.B.1    Laing, P.G.2    Hodge, E.S.3
  • 31
    • 0021120213 scopus 로고
    • Metal ion release from titanium-based prosthetic segmental replacement of long bones in baboons
    • Woodman J.L., Jacobs J.J., Galante J.O., Urban R.M. Metal ion release from titanium-based prosthetic segmental replacement of long bones in baboons. J Orthop Res. 1:1984;421-430.
    • (1984) J Orthop Res , vol.1 , pp. 421-430
    • Woodman, J.L.1    Jacobs, J.J.2    Galante, J.O.3    Urban, R.M.4
  • 32
    • 0018449066 scopus 로고
    • In vitro corrosion testing of titanium surgical implant alloys
    • Solar R.J., Pollack S.R., Korostoff E. In vitro corrosion testing of titanium surgical implant alloys. J Biomed Mater Res. 13:1979;217-250.
    • (1979) J Biomed Mater Res , vol.13 , pp. 217-250
    • Solar, R.J.1    Pollack, S.R.2    Korostoff, E.3
  • 33
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement
    • Urban R.M., Jacobs J.J., Tomlinson M.J., Gavrilovic J., Black J. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Surg. 82-A:2000;457-476.
    • (2000) J Bone Joint Surg , vol.82 A , pp. 457-476
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3    Gavrilovic, J.4    Black, J.5
  • 34
    • 2542542518 scopus 로고
    • Titanium, a metal for surgery
    • Leventhal G.S. Titanium, a metal for surgery. J Bone Joint Surg. 33-A:1951;473-474.
    • (1951) J Bone Joint Surg , vol.33 A , pp. 473-474
    • Leventhal, G.S.1
  • 35
    • 0014983592 scopus 로고
    • Sintered fiber metal composites as a basis for attachment of implants to bone
    • Galante J., Rostoker W., Lueck R., Ray R.D. Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg. 53-A:1971;101-114.
    • (1971) J Bone Joint Surg , vol.53 A , pp. 101-114
    • Galante, J.1    Rostoker, W.2    Lueck, R.3    Ray, R.D.4
  • 36
    • 0029682025 scopus 로고    scopus 로고
    • Titanium plate fixation: A review of implant failures
    • Banovetz J.M., Sharp R., Probe R.A., Anglen J.O. Titanium plate fixation. a review of implant failures J Orthop Trauma. 10(6):1996;389-394.
    • (1996) J Orthop Trauma , vol.10 , Issue.6 , pp. 389-394
    • Banovetz, J.M.1    Sharp, R.2    Probe, R.A.3    Anglen, J.O.4
  • 37
    • 0025203230 scopus 로고
    • Clinical experience with titanium implants, especially with the limited contact dynamic compression plate system
    • Matter P., Burch H.B. Clinical experience with titanium implants, especially with the limited contact dynamic compression plate system. Arch Orthop Trauma Surg. 109:1990;311-313.
    • (1990) Arch Orthop Trauma Surg , vol.109 , pp. 311-313
    • Matter, P.1    Burch, H.B.2
  • 38
    • 0023780276 scopus 로고
    • Custom titanium plating for failed nonunion or delayed internal fixation of femoral fractures
    • Johnson E.E. Custom titanium plating for failed nonunion or delayed internal fixation of femoral fractures. Clin Orthop. 234:1988;195-203.
    • (1988) Clin Orthop , vol.234 , pp. 195-203
    • Johnson, E.E.1
  • 40
    • 0019409452 scopus 로고
    • The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures. An experimental study in dogs
    • Uthoff H.K., Bardos D.I., Liskova-Kiar M. The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures. An experimental study in dogs. J Bone Joint Surg. 63-B:1981;427-434.
    • (1981) J Bone Joint Surg , vol.63 B , pp. 427-434
    • Uthoff, H.K.1    Bardos, D.I.2    Liskova-Kiar, M.3
  • 41
    • 0018178599 scopus 로고
    • The comparison of steel and titanium dynamic compression plates for internal fixation of 256 fractures of the tibia
    • Holzach P., Matter P. The comparison of steel and titanium dynamic compression plates for internal fixation of 256 fractures of the tibia. Injury. 10:1978;120-123.
    • (1978) Injury , vol.10 , pp. 120-123
    • Holzach, P.1    Matter, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.