메뉴 건너뛰기




Volumn 31, Issue SUPPL. 4, 2000, Pages

Unalloyed titanium for implants in bone surgery

Author keywords

Allergy; Biocompatibility; Bone surgery; Osseointegration; Titanium implants

Indexed keywords

ALLOY; STAINLESS STEEL; TITANIUM;

EID: 0034448368     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0020-1383(00)80016-9     Document Type: Article
Times cited : (191)

References (15)
  • 1
    • 0343457144 scopus 로고
    • The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP)
    • Parren SM. The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP). Injury. 26:(S1):1991;26-30.
    • (1991) Injury , vol.26 , Issue.S1 , pp. 26-30
    • Parren, S.M.1
  • 2
    • 0037587013 scopus 로고
    • Fatigue and corrosion fatigue studies on stainless-steel implant material
    • Winter G.S. Chichester, New York, Brisbane, Toronto, Singapore: John Wiley & Sons Ltd
    • Pohler OEM, Straumann F. Fatigue and corrosion fatigue studies on stainless-steel implant material. Winter GS. Evaluation of Biomaterials. 1980;John Wiley & Sons Ltd, Chichester, New York, Brisbane, Toronto, Singapore.
    • (1980) Evaluation of Biomaterials
    • Pohler, O.E.M.1    Straumann, F.2
  • 3
    • 0002989884 scopus 로고
    • Degradation of metallic orthopedic implants
    • Rubin L.R. St. Louis Toronto London: The CV Mosby Comp. Chap. 15
    • Pohler OEM. Degradation of metallic orthopedic implants. Rubin LR. Biomaterials in reconstructive surgery. 1983;158-228 The CV Mosby Comp, St. Louis Toronto London. Chap. 15.
    • (1983) Biomaterials in Reconstructive Surgery , pp. 158-228
    • Pohler, O.E.M.1
  • 4
    • 0029980240 scopus 로고    scopus 로고
    • Influence of the materials for fixation implants on local infection. An experimental study of steel versus titanium DC-Plates in rabbits
    • Arens St, Schlegel U, Printzen G, Ziegler WJ, Perren SM, Hansis M. Influence of the materials for fixation implants on local infection. An experimental study of steel versus titanium DC-Plates in rabbits. J Bone Joint Surg. [Br]. 78-B:1996;647-651.
    • (1996) J Bone Joint Surg. [Br] , vol.78 , pp. 647-651
    • Arens, S.1    Schlegel, U.2    Printzen, G.3    Ziegler, W.J.4    Perren, S.M.5    Hansis, M.6
  • 5
    • 0030340536 scopus 로고    scopus 로고
    • Infection after intramedullary nailing: An experimental investigation on rabbits
    • Melcher GA, Hauke C, Metzdorf A, et al. Infection after intramedullary nailing: An experimental investigation on rabbits. Injury. 27:(3):1996;C23-C26.
    • (1996) Injury , vol.27 , Issue.3
    • Melcher, G.A.1    Hauke, C.2    Metzdorf, A.3
  • 8
    • 0013620724 scopus 로고
    • Evaluation of tissue compatibility of in vitro cultures of embryonic bone
    • Winter G.D. Chichester, New York, Brisbane, Toronto, Singapore: John Wiley & Sons Ltd.
    • Gerber H.-W., Perren SM. Evaluation of tissue compatibility of in vitro cultures of embryonic bone. Winter GD. Evaluation of Biomaterials. 1980;John Wiley & Sons Ltd. Chichester, New York, Brisbane, Toronto, Singapore.
    • (1980) Evaluation of Biomaterials
    • Gerber, H.-W.1    Perren, S.M.2
  • 9
    • 0028317968 scopus 로고
    • Evaluation of the soft tissue interface at titanium implants with different surface treatments: Experimental study on rabbits
    • Ungersböck A, Pohler O, Perren SM. Evaluation of the soft tissue interface at titanium implants with different surface treatments: Experimental study on rabbits. Bio-Medical Materials and Engineering. 4:1994;317-325.
    • (1994) Bio-Medical Materials and Engineering , vol.4 , pp. 317-325
    • Ungersböck, A.1    Pohler, O.2    Perren, S.M.3
  • 10
    • 0030130652 scopus 로고    scopus 로고
    • Evaluation of soft tissue reactions at the interface of titanium LC-DCP implants with different surface treatments. An experimental sheep study (1994)
    • Ungersböck A, Pohler O, Perren SM. Evaluation of soft tissue reactions at the interface of titanium LC-DCP implants with different surface treatments. An experimental sheep study (1994). Biomaterials. 17:(8):1996;797-806.
    • (1996) Biomaterials , vol.17 , Issue.8 , pp. 797-806
    • Ungersböck, A.1    Pohler, O.2    Perren, S.M.3
  • 11
    • 0016980179 scopus 로고
    • Gewebsreaktion auf ein Titan-Hohlzylinderimplantat mit Titan-Spritzschichtoberfläche
    • Schröder A, Pohler O, Sutter F. Gewebsreaktion auf ein Titan-Hohlzylinderimplantat mit Titan-Spritzschichtoberfläche. Schweiz. Mschr. Zahnheilk. 86:1976;713.
    • (1976) Schweiz. Mschr. Zahnheilk. , vol.86 , pp. 713
    • Schröder, A.1    Pohler, O.2    Sutter, F.3
  • 13
    • 0342587231 scopus 로고    scopus 로고
    • Compatibility of titanium in soft and hard tissue - The ultimate in osseointegration
    • München
    • Steinemann SG. Compatibility of titanium in soft and hard tissue - The ultimate in osseointegration. Proc. Euromat 99. 1999;. München.
    • (1999) Proc. Euromat 99
    • Steinemann, S.G.1
  • 14
    • 0025900565 scopus 로고
    • Influence of surface characteristics on bone intergration of implants. A histomorphometric study on miniature pigs
    • Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone intergration of implants. A histomorphometric study on miniature pigs. J. of Biomed. Mat. Res. 25:1991;889-902.
    • (1991) J. of Biomed. Mat. Res. , vol.25 , pp. 889-902
    • Buser, D.1    Schenk, R.K.2    Steinemann, S.3    Fiorellini, J.P.4    Fox, C.H.5    Stich, H.6
  • 15
    • 0022831349 scopus 로고
    • Swiss screws: Concept and experimental work
    • Pohler OEM. Swiss screws: concept and experimental work. J Oral Implantology. 12:(3):1986;338-348.
    • (1986) J Oral Implantology , vol.12 , Issue.3 , pp. 338-348
    • Pohler, O.E.M.1