메뉴 건너뛰기




Volumn , Issue , 2010, Pages 568-573

Biosensors in automatic measurements: An application to winemaking monitoring

Author keywords

Automatic measurement station; Biosensors; Fermentation monitoring; FIA

Indexed keywords

AMPEROMETRIC BIOSENSORS; ANALYTE CONCENTRATION; AUTOMATIC MEASUREMENT SYSTEM; AUTOMATIC MEASUREMENTS; BIOLOGICAL PROCESS; FERMENTATION MONITORING; FIA; FLOW INJECTION; FLOW INJECTION ANALYSIS; HUMAN EXPERT; HUMAN INTERACTIONS; MEASUREMENT PROCESS;

EID: 77957848566     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IMTC.2010.5488233     Document Type: Conference Paper
Times cited : (2)

References (26)
  • 4
    • 22044453261 scopus 로고    scopus 로고
    • Ethanol biosensors based on alcohol oxidase
    • A.M. Azevedo et alii "Ethanol biosensors based on alcohol oxidase", Biosensensor and Bioelectronics, vol.28 n. 2, pp. 235-247, 2005.
    • (2005) Biosensensor and Bioelectronics , vol.28 , Issue.2 , pp. 235-247
    • Azevedo, A.M.1
  • 5
    • 33847180928 scopus 로고    scopus 로고
    • Glucose Oxidase (GOD)-coupled amperometric microsensor with integrated electrochemical actuation system
    • 16-19 May
    • J Park et alii: "Glucose Oxidase (GOD)-Coupled Amperometric Microsensor with Integrated Electrochemical Actuation System", in Proc. of IEEE IMTC vol. 1, pp. 134-138, 16-19 May 2005.
    • (2005) Proc. of IEEE IMTC , vol.1 , pp. 134-138
    • Park, J.1
  • 9
    • 0001392187 scopus 로고
    • Flow injection analysis - A survey of its potential for continuous monitoring of industrial processes
    • J. Ruzicka, "Flow injection analysis - a survey of its potential for continuous monitoring of industrial processes," Anal. Chim. Acta, vol. 190, pp. 155-163, 1986.
    • (1986) Anal. Chim. Acta , vol.190 , pp. 155-163
    • Ruzicka, J.1
  • 10
    • 33847299565 scopus 로고    scopus 로고
    • Computational fluid dynamics model for optimal flow injection analysis biosensor design
    • Nov.
    • S. Vermeir et alii: "Computational fluid dynamics model for optimal flow injection analysis biosensor design", IEEE Sensors, Nov. 2005.
    • (2005) IEEE Sensors
    • Vermeir, S.1
  • 12
    • 67650545013 scopus 로고    scopus 로고
    • Instrumentation and perfomanance evaluation of amperometric biosensor using BIOBENCH
    • V. G. Sangamt et alii: "Instrumentation and Perfomanance Evaluation of Amperometric Biosensor Using BIOBENCH", in Proc. of IEEE/EMBS on Medical Devices and Biosensors.
    • Proc. of IEEE/EMBS on Medical Devices and Biosensors
    • Sangamt, V.G.1
  • 14
    • 36049033703 scopus 로고    scopus 로고
    • Design of a low-cost portable potentiostat for amperometric biosensors
    • J.R. Blanco, et alii: "Design of a Low-Cost Portable Potentiostat for Amperometric Biosensors" in Proc. of IEEE IMTC, pp. 690-694, 2006.
    • (2006) Proc. of IEEE IMTC , pp. 690-694
    • Blanco, J.R.1
  • 15
    • 77957829617 scopus 로고    scopus 로고
    • http://ww1.microchip.com/downloads/en/DeviceDoc/39626b.pdf
  • 16
    • 0028851786 scopus 로고
    • Development of an extremely flexible automatic analyzer with integrated biosensors for on-line control of fermentation processes
    • W. Schuhmann, H. Wohlschläger, J. Huber, H.L. Schmidt, H. Stadler, "Development of an extremely flexible automatic analyzer with integrated biosensors for on-line control of fermentation processes", Analytica Chimica Acta 315 (1-2), pp. 113-122, 1995.
    • (1995) Analytica Chimica Acta , vol.315 , Issue.1-2 , pp. 113-122
    • Schuhmann, W.1    Wohlschläger, H.2    Huber, J.3    Schmidt, H.L.4    Stadler, H.5
  • 20
    • 2442534853 scopus 로고    scopus 로고
    • Electrochemical biosensor for monitoring malolactic fermentation in red wine using two strains of Oenococcus oeni
    • M. Esti, G. Volpe, L. Micheli, E. Delibato, D. Compagnone, D. Moscone, G. Palleschi, "Electrochemical biosensor for monitoring malolactic fermentation in red wine using two strains of Oenococcus oeni", Analalitica Chimica Acta, 513, pp. 357-364, 2004.
    • (2004) Analalitica Chimica Acta , vol.513 , pp. 357-364
    • Esti, M.1    Volpe, G.2    Micheli, L.3    Delibato, E.4    Compagnone, D.5    Moscone, D.6    Palleschi, G.7
  • 21
    • 0035304513 scopus 로고    scopus 로고
    • Amperometric biosensor for polyphenols based on Horseradish peroxidase immobilized on gold electrodes
    • S. Imabayashi, Y.T. Kong, M. Watanabe: "Amperometric biosensor for polyphenols based on Horseradish peroxidase immobilized on gold electrodes", Electroanalysis 13, vol. 408-412, 2000.
    • (2000) Electroanalysis , vol.13 , pp. 408-412
    • Imabayashi, S.1    Kong, Y.T.2    Watanabe, M.3
  • 22
    • 0036096757 scopus 로고    scopus 로고
    • Review of the use of biosensors as analytical tools in the food and drink industries
    • L.D. Mello,L.T. Kubota: "Review of the use of biosensors as analytical tools in the food and drink industries", Food Chem.77 pp. 237-256, 2002.
    • (2002) Food Chem. , vol.77 , pp. 237-256
    • Mello, L.D.1    Kubota, L.T.2
  • 23
    • 84944748300 scopus 로고    scopus 로고
    • Poly (hydroxyl ethyl methacrylate) hydrogel matrix for phenol biosensor
    • S. M. Khor et alii "Poly (hydroxyl ethyl methacrylate) hydrogel matrix for phenol biosensor", Proc. of Asian Conference on Sensors, pp. 207-211, 2003.
    • (2003) Proc. of Asian Conference on Sensors , pp. 207-211
    • Khor, S.M.1
  • 24
    • 58149159194 scopus 로고    scopus 로고
    • Electrochemical enzyme-electrode biosensor for Glucose detection
    • Jui-Lin Lai et alii: "Electrochemical enzyme-electrode biosensor for Glucose detection ", in Proc. of ICCCA, pp. 1208-1212, 2008.
    • (2008) Proc. of ICCCA , pp. 1208-1212
    • Lai, J.-L.1
  • 26
    • 77957839399 scopus 로고    scopus 로고
    • http://www.palmsens.com/instruments/palmsens/specifications/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.