메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Biosensor-based intelligent measurement system for wine fermentation monitoring

Author keywords

[No Author keywords available]

Indexed keywords

CONDITIONING CIRCUIT; DISTRIBUTED MEASUREMENT SYSTEMS; INNOVATIVE APPROACHES; INTELLIGENT MEASUREMENT; LOCAL MEASUREMENT; MEASUREMENT PROCESS; MULTI SENSOR; PROCESSING MODULES; SIGNAL ACQUISITIONS; SYSTEM INTELLIGENCE; WINE FERMENTATION;

EID: 77951711280     PISSN: 15301605     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/HICSS.2010.84     Document Type: Conference Paper
Times cited : (4)

References (19)
  • 4
    • 22044453261 scopus 로고    scopus 로고
    • Ethanol biosensors based on alcohol oxidase
    • A.M. Azevedo et alii "Ethanol biosensors based on alcohol oxidase", Biosensensor and Bioelectronics, vol.28 n. 2, pp. 235-247, 2005.
    • (2005) Biosensensor and Bioelectronics , vol.28 , Issue.2 , pp. 235-247
    • Azevedo, A.M.1
  • 5
    • 33847180928 scopus 로고    scopus 로고
    • Glucose Oxidase (GOD)-Coupled Amperometric Microsensor with Integrated Electrochemical Actuation System
    • 16-19 May
    • J Park et alii: "Glucose Oxidase (GOD)-Coupled Amperometric Microsensor with Integrated Electrochemical Actuation System", in Proc. of IEEE IMTC vol. 1, pp. 134-138, 16-19 May 2005.
    • (2005) Proc. of IEEE IMTC , vol.1 , pp. 134-138
    • Park, J.1
  • 9
    • 0001392187 scopus 로고
    • Flow injection analysis - A survey of its potential for continuous monitoring of industrial processes
    • J. Ruzicka, "Flow injection analysis - a survey of its potential for continuous monitoring of industrial processes," Anal. Chim. Acta, vol. 190, pp. 155-163, 1986.
    • (1986) Anal. Chim. Acta , vol.190 , pp. 155-163
    • Ruzicka, J.1
  • 10
    • 33847299565 scopus 로고    scopus 로고
    • Computational fluid dynamics model for optimal flow injection analysis biosensor design
    • Nov.
    • S. Vermeir et alii: "Computational fluid dynamics model for optimal flow injection analysis biosensor design",IEEE Sensors, Nov. 2005.
    • (2005) IEEE Sensors
    • Vermeir, S.1
  • 12
    • 67650545013 scopus 로고    scopus 로고
    • Instrumentation and Perfomanance Evaluation of Amperometric Biosensor Using BIOBENCH
    • V. G. Sangamt et alii: "Instrumentation and Perfomanance Evaluation of Amperometric Biosensor Using BIOBENCH", in Proc. of IEEE/EMBS on Medical Devices and Biosensors.
    • Proc. of IEEE/EMBS on Medical Devices and Biosensors
    • Sangamt, V.G.1
  • 13
    • 77951703331 scopus 로고    scopus 로고
    • www.palmsens.com
  • 15
    • 84944748300 scopus 로고    scopus 로고
    • Poly (hydroxyl ethyl methacrylate) hydrogel matrix for phenol biosensor
    • S. M. Khor et alii "Poly (hydroxyl ethyl methacrylate) hydrogel matrix for phenol biosensor", Proc. of Asian Conference on Sensors, pp. 207-211, 2003.
    • (2003) Proc. of Asian Conference on Sensors , pp. 207-211
    • Khor, S.M.1
  • 17
    • 58149159194 scopus 로고    scopus 로고
    • Electrochemical enzymeelectrode biosensor for Glucose detection
    • Jui-Lin Lai et alii: "Electrochemical enzymeelectrode biosensor for Glucose detection ", in Proc. of ICCCA, pp. 1208-1212, 2008.
    • (2008) Proc. of ICCCA , pp. 1208-1212
    • Lai, J.-L.1
  • 18
    • 36049033703 scopus 로고    scopus 로고
    • Design of a Low-Cost Portable Potentiostat for Amperometric Biosensors
    • J.R. Blanco, et alii: "Design of a Low-Cost Portable Potentiostat for Amperometric Biosensors" in Proc. of IEEE IMTC, pp. 690-694, 2006.
    • (2006) Proc. of IEEE IMTC , pp. 690-694
    • Blanco, J.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.