-
2
-
-
0036392071
-
18F] fluorodeoxyglucose
-
18F] fluorodeoxyglucose. Methods 27(3):218-225
-
(2002)
Methods
, vol.27
, Issue.3
, pp. 218-225
-
-
Wienhard, K.1
-
4
-
-
27144477723
-
Measurement of input functions in rodents: Challenges and solutions
-
Laforest R, Sharp TL, Engelbach JA et al (2005) Measurement of input functions in rodents: challenges and solutions. Nucl Med Biol 32(7): 679-685
-
(2005)
Nucl Med Biol
, vol.32
, Issue.7
, pp. 679-685
-
-
Laforest, R.1
Sharp, T.L.2
Engelbach, J.A.3
-
5
-
-
0024592575
-
Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose
-
Gambhir SS, Schwaiger M, Huang SC et al (1989) Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose. J Nucl Med 30(3):359-366
-
(1989)
J Nucl Med
, vol.30
, Issue.3
, pp. 359-366
-
-
Gambhir, S.S.1
Schwaiger, M.2
Huang, S.C.3
-
6
-
-
0032724254
-
On the use of image-derived input functions in oncological fluorine-18 fluorodeoxyglucose positron emission tomography studies
-
Hoekstra CJ, Hoekstra OS, Lammertsma AA (1999) On the use of image-derived input functions in oncological fluorine-18 fluorodeoxyglucose positron emission tomography studies. Eur J Nucl Med 26(11):1489-1492
-
(1999)
Eur J Nucl Med
, vol.26
, Issue.11
, pp. 1489-1492
-
-
Hoekstra, C.J.1
Hoekstra, O.S.2
Lammertsma, A.A.3
-
7
-
-
0025765313
-
Noninvasive method to obtain input function for measuring tissue glucose utilization of thoracic and abdominal organs
-
Ohtake T, Kosaka N, Watanabe T et al (1991) Noninvasive method to obtain input function for measuring tissue glucose utilization of thoracic and abdominal organs. J Nucl Med 32(7):1432-1438
-
(1991)
J Nucl Med
, vol.32
, Issue.7
, pp. 1432-1438
-
-
Ohtake, T.1
Kosaka, N.2
Watanabe, T.3
-
8
-
-
0027497419
-
Target apex-seeking in factor analysis of medical image sequences
-
Buvat I, Benali H, Frouin F, Bazin JP, Di Paola R (1993) Target apex-seeking in factor analysis of medical image sequences. Phys Med Biol 38(1):123-138
-
(1993)
Phys Med Biol
, vol.38
, Issue.1
, pp. 123-138
-
-
Buvat, I.1
Benali, H.2
Frouin, F.3
Bazin, J.P.4
Di Paola, R.5
-
10
-
-
0036489379
-
Correction for ambiguous solutions in factor analysis using a penalized least squares objective
-
Sitek A, Gullberg GT, Huesman RH (2002) Correction for ambiguous solutions in factor analysis using a penalized least squares objective. IEEE Trans Med Imaging 21(3):216-225
-
(2002)
IEEE Trans Med Imaging
, vol.21
, Issue.3
, pp. 216-225
-
-
Sitek, A.1
Gullberg, G.T.2
Huesman, R.H.3
-
11
-
-
34147146341
-
The application of maximum likelihood factor analysis (MLFA) with uniqueness constraints on dynamic cardiac microPET data
-
Su Y, Welch MJ, Shoghi KI (2007) The application of maximum likelihood factor analysis (MLFA) with uniqueness constraints on dynamic cardiac microPET data. Phys Med Biol 52(8):2313-2334
-
(2007)
Phys Med Biol
, vol.52
, Issue.8
, pp. 2313-2334
-
-
Su, Y.1
Welch, M.J.2
Shoghi, K.I.3
-
12
-
-
48149103711
-
Single input multiple output (SIMO) optimization for input function estimation: A simulation study
-
NSS '07. IEEE
-
Su Y, Welch MJ, Shoghi KI (2007) Single input multiple output (SIMO) optimization for input function estimation: a simulation study. Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE 6:4481-4484
-
(2007)
Nuclear Science Symposium Conference Record, 2007
, vol.6
, pp. 4481-4484
-
-
Su, Y.1
Welch, M.J.2
Shoghi, K.I.3
-
13
-
-
0031282828
-
A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: Theory and simulation study
-
Feng D, Wong KP, Wu CM, Siu WC (1997) A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study. IEEE Trans Inf Technol Biomed 1(4):243-254
-
(1997)
IEEE Trans Inf Technol Biomed
, vol.1
, Issue.4
, pp. 243-254
-
-
Feng, D.1
Wong, K.P.2
Wu, C.M.3
Siu, W.C.4
-
14
-
-
0035263431
-
Simultaneous estimation of physiological parameters and the input function-in vivo PET data
-
Wong KP, Feng D, Meikle SR, Fulham MJ (2001) Simultaneous estimation of physiological parameters and the input function-in vivo PET data. IEEE Trans Inf Technol Biomed 5(1):67-76
-
(2001)
IEEE Trans Inf Technol Biomed
, vol.5
, Issue.1
, pp. 67-76
-
-
Wong, K.P.1
Feng, D.2
Meikle, S.R.3
Fulham, M.J.4
-
15
-
-
0027572378
-
Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography
-
Feng D, Huang SC, Wang X (1993) Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography. Int J Biomed Comput 32(2):95-110
-
(1993)
Int J Biomed Comput
, vol.32
, Issue.2
, pp. 95-110
-
-
Feng, D.1
Huang, S.C.2
Wang, X.3
-
16
-
-
36849081804
-
18FFDG input function in mice by use of dynamic small-animal PET and minimal blood sample data
-
18FFDG input function in mice by use of dynamic small-animal PET and minimal blood sample data. J Nucl Med
-
(2007)
J Nucl Med
-
-
Ferl, G.Z.1
Zhang, X.2
Wu, H.M.3
Huang, S.C.4
-
17
-
-
38549132359
-
Variation of kinetic model parameters due to input peak distortions and noise in simulated 82Rb PET perfusion studies
-
IEEE
-
Meyer C, Weibrecht M, Peligrad DN (2006) Variation of kinetic model parameters due to input peak distortions and noise in simulated 82Rb PET perfusion studies. Nuclear Science Symposium Conference Record, 2006. IEEE 5:2703-2707
-
(2006)
Nuclear Science Symposium Conference Record, 2006
, vol.5
, pp. 2703-2707
-
-
Meyer, C.1
Weibrecht, M.2
Peligrad, D.N.3
-
18
-
-
38649091061
-
Evaluation of an input function model that incorporates the injection schedule in FDG-PET studies
-
IEEE
-
Wong K-P, Huang S-C, Fulham MJ (2006) Evaluation of an input function model that incorporates the injection schedule in FDG-PET studies. Nuclear Science Symposium Conference Record, 2006. IEEE 4:2086-2090
-
(2006)
Nuclear Science Symposium Conference Record, 2006
, vol.4
, pp. 2086-2090
-
-
Wong, K.-P.1
Huang, S.-C.2
Fulham, M.J.3
-
19
-
-
35848956095
-
Hybrid image and blood sampling input function for quantification of small animal dynamic PET data
-
Shoghi KI, Welch MJ (2007) Hybrid image and blood sampling input function for quantification of small animal dynamic PET data. Nucl Med Biol 34(8):989-994
-
(2007)
Nucl Med Biol
, vol.34
, Issue.8
, pp. 989-994
-
-
Shoghi, K.I.1
Welch, M.J.2
-
21
-
-
2942654916
-
Development of a 4-D digital mouse phantom for molecular imaging research
-
Segars WP, Tsui BM, Frey EC, Johnson GA, Berr SS (2004) Development of a 4-D digital mouse phantom for molecular imaging research. Mol Imaging Biol 6(3):149-159
-
(2004)
Mol Imaging Biol
, vol.6
, Issue.3
, pp. 149-159
-
-
Segars, W.P.1
Tsui, B.M.2
Frey, E.C.3
Johnson, G.A.4
Berr, S.S.5
-
22
-
-
33645517670
-
Generalized five-dimensional dynamic and spectral factor analysis
-
El Fakhri G, Sitek A, Zimmerman RE, Ouyang J (2006) Generalized five-dimensional dynamic and spectral factor analysis. Med Phys 33 (4):1016-1024
-
(2006)
Med Phys
, vol.33
, Issue.4
, pp. 1016-1024
-
-
El Fakhri, G.1
Sitek, A.2
Zimmerman, R.E.3
Ouyang, J.4
-
23
-
-
58149260414
-
Wavelet denoising in voxel based parametric estimation of small animal PET images: A systematic evaluation of spatial constraints and noise reduction algorithms
-
Su Y, Shoghi KI (2008) Wavelet denoising in voxel based parametric estimation of small animal PET images: a systematic evaluation of spatial constraints and noise reduction algorithms Phys Med Biol 53(21):5899-5915
-
(2008)
Phys Med Biol
, vol.53
, Issue.21
, pp. 5899-5915
-
-
Su, Y.1
Shoghi, K.I.2
-
24
-
-
77956722948
-
-
University of California Los Angeles Department of Molecular and Medical Pharmacology UCLA Mouse Quantitation Project, Accessed March 2008
-
University of California Los Angeles Department of Molecular and Medical Pharmacology UCLA Mouse Quantitation Project. (http://dragon.nuc.ucla.edu). Accessed March 2008
-
-
-
-
25
-
-
38549159457
-
A public domain dynamic mouse FDG MicroPET image data set for evaluation and validation of input function derivation methods
-
IEEE
-
Huang SC, Wu HM, Truong D et al (2006) A public domain dynamic mouse FDG MicroPET image data set for evaluation and validation of input function derivation methods. Nuclear Science Symposium Conference Record, 2006. IEEE 5:2681-2683
-
(2006)
Nuclear Science Symposium Conference Record, 2006
, vol.5
, pp. 2681-2683
-
-
Huang, S.C.1
Wu, H.M.2
Truong, D.3
-
26
-
-
0024760875
-
Analyze: A comprehensive, operator-interactive software package for multidimensional medical image display and analysis
-
Robb RA, Hanson DP, Karwoski RA et al (1989) Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis. Comput Med Imaging Graph 13(6):433-454
-
(1989)
Comput Med Imaging Graph
, vol.13
, Issue.6
, pp. 433-454
-
-
Robb, R.A.1
Hanson, D.P.2
Karwoski, R.A.3
|