메뉴 건너뛰기




Volumn 34, Issue 8, 2007, Pages 989-994

Hybrid image and blood sampling input function for quantification of small animal dynamic PET data

Author keywords

Blood input function; Image quantification; Small animal PET imaging

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 35848956095     PISSN: 09698051     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nucmedbio.2007.07.010     Document Type: Article
Times cited : (38)

References (19)
  • 1
    • 0024448632 scopus 로고
    • Kinetic analysis of central [11C]raclopride binding to D2-dopamine receptors studied by PET - a comparison to the equilibrium analysis
    • Farde L., Eriksson L., Blomquist G., and Halldin C. Kinetic analysis of central [11C]raclopride binding to D2-dopamine receptors studied by PET - a comparison to the equilibrium analysis. J Cereb Blood Flow Metab 9 5 (1989) 696-708
    • (1989) J Cereb Blood Flow Metab , vol.9 , Issue.5 , pp. 696-708
    • Farde, L.1    Eriksson, L.2    Blomquist, G.3    Halldin, C.4
  • 2
    • 33645991546 scopus 로고    scopus 로고
    • Assessment of myocardial blood flow using 15O-water and 1-11C-acetate in rats with small-animal PET
    • Herrero P., Kim J., Sharp T.L., Engelbach J.A., Lewis J.S., Gropler R.J., et al. Assessment of myocardial blood flow using 15O-water and 1-11C-acetate in rats with small-animal PET. J Nucl Med 47 3 (2006) 477-485
    • (2006) J Nucl Med , vol.47 , Issue.3 , pp. 477-485
    • Herrero, P.1    Kim, J.2    Sharp, T.L.3    Engelbach, J.A.4    Lewis, J.S.5    Gropler, R.J.6
  • 3
    • 33745070330 scopus 로고    scopus 로고
    • Assessment of myocardial metabolism in diabetic rats using small-animal PET: a feasibility study
    • Welch M.J., Lewis J.S., Kim J., Sharp T.L., Dence C.S., Gropler R.J., et al. Assessment of myocardial metabolism in diabetic rats using small-animal PET: a feasibility study. J Nucl Med 47 4 (2006) 689-697
    • (2006) J Nucl Med , vol.47 , Issue.4 , pp. 689-697
    • Welch, M.J.1    Lewis, J.S.2    Kim, J.3    Sharp, T.L.4    Dence, C.S.5    Gropler, R.J.6
  • 4
    • 0018861279 scopus 로고
    • The use of principal components in the quantitative analysis of gamma camera dynamic studies
    • Barber D.C. The use of principal components in the quantitative analysis of gamma camera dynamic studies. Phys Med Biol 25 2 (1980) 283-292
    • (1980) Phys Med Biol , vol.25 , Issue.2 , pp. 283-292
    • Barber, D.C.1
  • 6
    • 0029160881 scopus 로고
    • Factor analysis for extraction of blood time-activity curves in dynamic FDG-PET studies
    • Wu H.M., Hoh C.K., Choi Y., Schelbert H.R., Hawkins R.A., Phelps M.E., et al. Factor analysis for extraction of blood time-activity curves in dynamic FDG-PET studies. J Nucl Med 36 9 (1995) 1714-1722
    • (1995) J Nucl Med , vol.36 , Issue.9 , pp. 1714-1722
    • Wu, H.M.1    Hoh, C.K.2    Choi, Y.3    Schelbert, H.R.4    Hawkins, R.A.5    Phelps, M.E.6
  • 8
    • 34147133118 scopus 로고    scopus 로고
    • Minimally invasive method of determining blood input function from PET images in rodents
    • Kim J., Herrero P., Sharp T., Laforest R., Rowland D.J., Tai Y.C., et al. Minimally invasive method of determining blood input function from PET images in rodents. J Nucl Med 47 2 (2006) 330-336
    • (2006) J Nucl Med , vol.47 , Issue.2 , pp. 330-336
    • Kim, J.1    Herrero, P.2    Sharp, T.3    Laforest, R.4    Rowland, D.J.5    Tai, Y.C.6
  • 10
    • 25444484119 scopus 로고    scopus 로고
    • Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses
    • El Fakhri G., Sitek A., Guerin B., Kijewski M.F., Di Carli M.F., and Moore S.C. Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses. J Nucl Med 46 8 (2005) 1264-1271
    • (2005) J Nucl Med , vol.46 , Issue.8 , pp. 1264-1271
    • El Fakhri, G.1    Sitek, A.2    Guerin, B.3    Kijewski, M.F.4    Di Carli, M.F.5    Moore, S.C.6
  • 11
    • 0033804685 scopus 로고    scopus 로고
    • Factor analysis with a priori knowledge-application in dynamic cardiac SPECT
    • Sitek A., Di Bella E.V., and Gullberg G.T. Factor analysis with a priori knowledge-application in dynamic cardiac SPECT. Phys Med Biol 45 9 (2000) 2619-2638
    • (2000) Phys Med Biol , vol.45 , Issue.9 , pp. 2619-2638
    • Sitek, A.1    Di Bella, E.V.2    Gullberg, G.T.3
  • 12
    • 0036489379 scopus 로고    scopus 로고
    • Correction for ambiguous solutions in factor analysis using a penalized least squares objective
    • Sitek A., Gullberg G.T., and Huesman R.H. Correction for ambiguous solutions in factor analysis using a penalized least squares objective. IEEE Trans Med Imag 21 3 (2002) 216-225
    • (2002) IEEE Trans Med Imag , vol.21 , Issue.3 , pp. 216-225
    • Sitek, A.1    Gullberg, G.T.2    Huesman, R.H.3
  • 13
  • 14
    • 38649100361 scopus 로고    scopus 로고
    • Characterization of spillover and recovery coefficients in the gated mouse heart for non-invasive extraction of input function in microPET studies: feasibility and sensitivity analysis
    • Shoghi K.I., Rowland D.J., Laforest R., and Welch M.J. Characterization of spillover and recovery coefficients in the gated mouse heart for non-invasive extraction of input function in microPET studies: feasibility and sensitivity analysis. IEEE Nucl Sci Symp 4 (2006) 2134-2136
    • (2006) IEEE Nucl Sci Symp , vol.4 , pp. 2134-2136
    • Shoghi, K.I.1    Rowland, D.J.2    Laforest, R.3    Welch, M.J.4
  • 16
    • 35848949755 scopus 로고    scopus 로고
    • The wonder of Horner's method
    • Pathan A., and Collyer T. The wonder of Horner's method. Math Gaz 87 509 (2003) 230-242
    • (2003) Math Gaz , vol.87 , Issue.509 , pp. 230-242
    • Pathan, A.1    Collyer, T.2
  • 17
    • 34250620615 scopus 로고    scopus 로고
    • In vivo quantitation of glucose metabolism in mice using small-animal PET and a microfluidic device
    • Wu H.M., Sui G., Lee C.C., Prins M.L., Ladno W., Lin H.D., et al. In vivo quantitation of glucose metabolism in mice using small-animal PET and a microfluidic device. J Nuc Med 48 5 (2007) 837-845
    • (2007) J Nuc Med , vol.48 , Issue.5 , pp. 837-845
    • Wu, H.M.1    Sui, G.2    Lee, C.C.3    Prins, M.L.4    Ladno, W.5    Lin, H.D.6
  • 19
    • 38549132359 scopus 로고    scopus 로고
    • Variation of kinetic model parameters due to input peak distortions and noise in simulated 82Rb PET perfusion studies
    • Meyer C., Weibrecht M., and Peligrad D.-N. Variation of kinetic model parameters due to input peak distortions and noise in simulated 82Rb PET perfusion studies. IEEE Nucl Sci Symp 5 (2006) 2703-2707
    • (2006) IEEE Nucl Sci Symp , vol.5 , pp. 2703-2707
    • Meyer, C.1    Weibrecht, M.2    Peligrad, D.-N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.