-
1
-
-
77956475858
-
Radiation overdoses point up dangers of CT scans
-
A13
-
Bogdanich W. Radiation overdoses point up dangers of CT scans. New York Times 2009, A13.
-
(2009)
New York Times
-
-
Bogdanich, W.1
-
2
-
-
77956484186
-
CT Brain Perfusion Scans Safety Investigation:
-
Available at: Accessed July 28
-
CT Brain Perfusion Scans Safety Investigation: Initial Notification. Available at: Accessed July 28, 2010. http://www.fda.gov/Safety/MedWatch/SafetyInformation/SafetyAlertsforHumanMedicalProducts/ucm186105.htm.
-
(2010)
Initial Notification.
-
-
-
3
-
-
36549007486
-
Computed tomography-an increasing source of radiation exposure
-
Brenner D.J., Hall E.J. Computed tomography-an increasing source of radiation exposure. N Engl J Med 2007, 357:2277-2284.
-
(2007)
N Engl J Med
, vol.357
, pp. 2277-2284
-
-
Brenner, D.J.1
Hall, E.J.2
-
4
-
-
56149126478
-
Medical radiation exposure in the U.S. in 2006: preliminary results
-
Mettler F.A., Thomadsen B.R., Bhargavan M., et al. Medical radiation exposure in the U.S. in 2006: preliminary results. Health Phys 2008, 95:502-507.
-
(2008)
Health Phys
, vol.95
, pp. 502-507
-
-
Mettler, F.A.1
Thomadsen, B.R.2
Bhargavan, M.3
-
5
-
-
44349138945
-
Cancer risks from diagnostic radiology
-
Hall E.J., Brenner D.J. Cancer risks from diagnostic radiology. Br J Radiol 2008, 81:362-378.
-
(2008)
Br J Radiol
, vol.81
, pp. 362-378
-
-
Hall, E.J.1
Brenner, D.J.2
-
6
-
-
73149113560
-
Projected cancer risks from computed tomographic scans performed in the United States in 2007
-
Berrington de Gonzalez A., Mahesh M., Kim K.P., et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 2009, 169:2071-2077.
-
(2009)
Arch Intern Med
, vol.169
, pp. 2071-2077
-
-
Berrington de Gonzalez, A.1
Mahesh, M.2
Kim, K.P.3
-
7
-
-
10744219719
-
Cancer risks attributable to low doses of ionizing radiation: assessing what we really know
-
Brenner D.J., Doll R., Goodhead D.T., et al. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci U S A 2003, 100:13761-13766.
-
(2003)
Proc Natl Acad Sci U S A
, vol.100
, pp. 13761-13766
-
-
Brenner, D.J.1
Doll, R.2
Goodhead, D.T.3
-
9
-
-
0022703975
-
ALARA and an integrated approach to radiation protection
-
Hendee W.R., Edwards F.M. ALARA and an integrated approach to radiation protection. Semin Nucl Med 1986, 16:142-150.
-
(1986)
Semin Nucl Med
, vol.16
, pp. 142-150
-
-
Hendee, W.R.1
Edwards, F.M.2
-
10
-
-
73949157223
-
Image Gently: providing practical educational tools and advocacy to accelerate radiation protection for children worldwide
-
Goske M.J., Applegate K.E., Bell C., et al. Image Gently: providing practical educational tools and advocacy to accelerate radiation protection for children worldwide. Semin Ultrasound CT MR 2010, 31:57-63.
-
(2010)
Semin Ultrasound CT MR
, vol.31
, pp. 57-63
-
-
Goske, M.J.1
Applegate, K.E.2
Bell, C.3
-
11
-
-
69249178303
-
Image gently, step lightly: increasing radiation dose awareness in pediatric interventions through an international social marketing campaign
-
Sidhu M.K., Goske M.J., Coley B.J., et al. Image gently, step lightly: increasing radiation dose awareness in pediatric interventions through an international social marketing campaign. J Vasc Interv Radiol 2009, 20:1115-1119.
-
(2009)
J Vasc Interv Radiol
, vol.20
, pp. 1115-1119
-
-
Sidhu, M.K.1
Goske, M.J.2
Coley, B.J.3
-
12
-
-
84928096460
-
Tracking radiation exposure from diagnostic imaging devices at the NIH
-
Neumann R.D., Bluemke D.A. Tracking radiation exposure from diagnostic imaging devices at the NIH. J Am Coll Radiol 2010, 7:87-89.
-
(2010)
J Am Coll Radiol
, vol.7
, pp. 87-89
-
-
Neumann, R.D.1
Bluemke, D.A.2
-
14
-
-
77957932120
-
Quantification of radiation dose savings in cardiac computed tomography using prospectively triggered mode and ECG pulsing: a phantom study
-
Lehmkuhl L., Gosch D., Nagel H.D., et al. Quantification of radiation dose savings in cardiac computed tomography using prospectively triggered mode and ECG pulsing: a phantom study. Eur Radiol 2010, 20:2116-2125.
-
(2010)
Eur Radiol
, vol.20
, pp. 2116-2125
-
-
Lehmkuhl, L.1
Gosch, D.2
Nagel, H.D.3
-
15
-
-
77951132322
-
Coronary CT angiography with low radiation dose
-
Xu L., Zhang Z. Coronary CT angiography with low radiation dose. Int J Cardiovasc Imaging 2010, 26(Suppl 1):17-25.
-
(2010)
Int J Cardiovasc Imaging
, vol.26
, Issue.SUPPL 1
, pp. 17-25
-
-
Xu, L.1
Zhang, Z.2
-
16
-
-
77956464589
-
Feasibility of dose reduction using novel denoising techniques for low kV (80 kV) CT enterography: optimization and validation
-
in press
-
Guimarães L.S., Fletcher J.G., Yu L., et al. Feasibility of dose reduction using novel denoising techniques for low kV (80 kV) CT enterography: optimization and validation. Academic Radiology 2010, in press.
-
(2010)
Academic Radiology
-
-
Guimarães, L.S.1
Fletcher, J.G.2
Yu, L.3
-
17
-
-
76449091107
-
Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience
-
Prakash P., Kalra M.K., Digumarthy S.R., et al. Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr 2010, 34:40-45.
-
(2010)
J Comput Assist Tomogr
, vol.34
, pp. 40-45
-
-
Prakash, P.1
Kalra, M.K.2
Digumarthy, S.R.3
-
18
-
-
74749087439
-
Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm
-
Silva A.C., Lawder H.J., Hara A., et al. Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 2010, 194:191-199.
-
(2010)
AJR Am J Roentgenol
, vol.194
, pp. 191-199
-
-
Silva, A.C.1
Lawder, H.J.2
Hara, A.3
-
19
-
-
77954753249
-
Low-dose CT examinations in Crohn's disease: impact on image quality, diagnostic performance, and radiation dose
-
Kambadakone A.R., Prakash P., Hahn P.F., et al. Low-dose CT examinations in Crohn's disease: impact on image quality, diagnostic performance, and radiation dose. AJR Am J Roentgenol 2010, 195:78-88.
-
(2010)
AJR Am J Roentgenol
, vol.195
, pp. 78-88
-
-
Kambadakone, A.R.1
Prakash, P.2
Hahn, P.F.3
-
20
-
-
77954691805
-
Effect of altering automatic exposure control settings and quality reference mAs on radiation dose, image quality, and diagnostic efficacy in MDCT enterography of active inflammatory Crohn's disease
-
Allen B.C., Baker M.E., Einstein D.M., et al. Effect of altering automatic exposure control settings and quality reference mAs on radiation dose, image quality, and diagnostic efficacy in MDCT enterography of active inflammatory Crohn's disease. AJR Am J Roentgenol 2010, 195:89-100.
-
(2010)
AJR Am J Roentgenol
, vol.195
, pp. 89-100
-
-
Allen, B.C.1
Baker, M.E.2
Einstein, D.M.3
-
21
-
-
84928096084
-
Radiology order entry with decision support: initial clinical experience
-
Rosenthal D.I., Weilburg J.B., Schultz T., et al. Radiology order entry with decision support: initial clinical experience. J Am Coll Radiol 2006, 3:799-806.
-
(2006)
J Am Coll Radiol
, vol.3
, pp. 799-806
-
-
Rosenthal, D.I.1
Weilburg, J.B.2
Schultz, T.3
-
22
-
-
77952678558
-
Increasing the appropriateness of outpatient imaging: effects of a barrier to ordering low-yield examinations
-
Vartanians V.M., Sistrom C.L., Weilburg J.B., et al. Increasing the appropriateness of outpatient imaging: effects of a barrier to ordering low-yield examinations. Radiology 2010, 255:842-849.
-
(2010)
Radiology
, vol.255
, pp. 842-849
-
-
Vartanians, V.M.1
Sistrom, C.L.2
Weilburg, J.B.3
-
23
-
-
70349759467
-
Dual energy versus single energy MDCT: measurement of radiation dose using adult abdominal imaging protocols
-
Ho L.M., Yoshizumi T.T., Hurwitz L.M., et al. Dual energy versus single energy MDCT: measurement of radiation dose using adult abdominal imaging protocols. Acad Radiol 2009, 16:1400-1407.
-
(2009)
Acad Radiol
, vol.16
, pp. 1400-1407
-
-
Ho, L.M.1
Yoshizumi, T.T.2
Hurwitz, L.M.3
-
24
-
-
59249098264
-
Dual energy CT: preliminary observations and potential clinical applications in the abdomen
-
Graser A., Johnson T.R., Chandarana H., et al. Dual energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 2009, 19:13-23.
-
(2009)
Eur Radiol
, vol.19
, pp. 13-23
-
-
Graser, A.1
Johnson, T.R.2
Chandarana, H.3
|