메뉴 건너뛰기




Volumn 16, Issue 11, 2009, Pages 1400-1407

Dual Energy Versus Single Energy MDCT: Measurement of Radiation Dose Using Adult Abdominal Imaging Protocols

Author keywords

aortic CT; Dual Energy CT; liver CT; renal CT; Virtual Non contrast image reconstruction

Indexed keywords

ABDOMINAL AORTA; ARTICLE; BREAST; COMPUTED TOMOGRAPHY SCANNER; DOSIMETRY; HUMAN; IMAGE RECONSTRUCTION; KIDNEY; LIVER; LUMBAR SPINE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; SKIN; SMALL INTESTINE; SPLEEN; STOMACH;

EID: 70349759467     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2009.05.002     Document Type: Article
Times cited : (83)

References (17)
  • 2
    • 0037264162 scopus 로고    scopus 로고
    • Quantitative diagnosis of fatty liver with dual-energy CT. An experimental study in rabbits
    • Wang B., Gao Z., Zou Q., and Li L. Quantitative diagnosis of fatty liver with dual-energy CT. An experimental study in rabbits. Acta Radiol 44 (2003) 92-97
    • (2003) Acta Radiol , vol.44 , pp. 92-97
    • Wang, B.1    Gao, Z.2    Zou, Q.3    Li, L.4
  • 3
    • 37349084547 scopus 로고    scopus 로고
    • Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection-phantom study
    • Schindera S.T., Nelson R.C., Mukundan Jr. S., et al. Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection-phantom study. Radiology 246 (2008) 125-132
    • (2008) Radiology , vol.246 , pp. 125-132
    • Schindera, S.T.1    Nelson, R.C.2    Mukundan Jr., S.3
  • 4
    • 39749113025 scopus 로고    scopus 로고
    • Characterization of human renal stones with MDCT: advantage of dual energy and limitations due to respiratory motion
    • Grosjean R., Sauer B., Guerra R.M., et al. Characterization of human renal stones with MDCT: advantage of dual energy and limitations due to respiratory motion. AJR Am J Roentgenol 190 (2008) 720-728
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 720-728
    • Grosjean, R.1    Sauer, B.2    Guerra, R.M.3
  • 5
    • 36148936386 scopus 로고    scopus 로고
    • Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT
    • Primak A.N., Fletcher J.G., Vrtiska T.J., et al. Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. Acad Radiol 14 (2007) 1441-1447
    • (2007) Acad Radiol , vol.14 , pp. 1441-1447
    • Primak, A.N.1    Fletcher, J.G.2    Vrtiska, T.J.3
  • 6
    • 53749097507 scopus 로고    scopus 로고
    • Calcified vascular plaque specimens: assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantom
    • Boll D.T., Merkle E.M., Paulson E.K., Mirza R.A., and Fleiter T.R. Calcified vascular plaque specimens: assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantom. Radiology 249 (2008) 119-126
    • (2008) Radiology , vol.249 , pp. 119-126
    • Boll, D.T.1    Merkle, E.M.2    Paulson, E.K.3    Mirza, R.A.4    Fleiter, T.R.5
  • 7
    • 45149128319 scopus 로고    scopus 로고
    • Coronary stent patency: dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom
    • Boll D.T., Merkle E.M., Paulson E.K., and Fleiter T.R. Coronary stent patency: dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom. Radiology 247 (2008) 687-695
    • (2008) Radiology , vol.247 , pp. 687-695
    • Boll, D.T.1    Merkle, E.M.2    Paulson, E.K.3    Fleiter, T.R.4
  • 8
    • 43649084259 scopus 로고    scopus 로고
    • Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: a phantom study
    • Takahashi N., Hartman R.P., Vrtiska T.J., et al. Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: a phantom study. AJR Am J Roentgenol 190 (2008) 1169-1173
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 1169-1173
    • Takahashi, N.1    Hartman, R.P.2    Vrtiska, T.J.3
  • 9
    • 42649114425 scopus 로고    scopus 로고
    • Computed tomography with energy-resolved detection: a feasibility study
    • Shikhaliev P.M. Computed tomography with energy-resolved detection: a feasibility study. Phys Med Biol 53 (2008) 1475-1495
    • (2008) Phys Med Biol , vol.53 , pp. 1475-1495
    • Shikhaliev, P.M.1
  • 10
    • 38149109994 scopus 로고    scopus 로고
    • Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience
    • Graser A., Johnson T.R., Bader M., et al. Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Invest Radiol 43 (2008) 112-119
    • (2008) Invest Radiol , vol.43 , pp. 112-119
    • Graser, A.1    Johnson, T.R.2    Bader, M.3
  • 11
    • 34247606356 scopus 로고    scopus 로고
    • Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry
    • Yoshizumi T.T., Goodman P.C., Frush D.P., et al. Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry. AJR Am J Roentgenol 188 (2007) 1332-1336
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 1332-1336
    • Yoshizumi, T.T.1    Goodman, P.C.2    Frush, D.P.3
  • 12
    • 34250806587 scopus 로고    scopus 로고
    • Pediatric cardiac-gated CT angiography: assessment of radiation dose
    • Hollingsworth C.L., Yoshizumi T.T., Frush D.P., et al. Pediatric cardiac-gated CT angiography: assessment of radiation dose. AJR Am J Roentgenol 189 (2007) 12-18
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 12-18
    • Hollingsworth, C.L.1    Yoshizumi, T.T.2    Frush, D.P.3
  • 13
    • 34648819024 scopus 로고    scopus 로고
    • Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols
    • Hurwitz L.M., Yoshizumi T.T., Goodman P.C., et al. Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomogr 31 (2007) 544-549
    • (2007) J Comput Assist Tomogr , vol.31 , pp. 544-549
    • Hurwitz, L.M.1    Yoshizumi, T.T.2    Goodman, P.C.3
  • 14
    • 35649009454 scopus 로고    scopus 로고
    • Radiation doses from small-bowel follow-through and abdominopelvic MDCT in Crohn's disease
    • Jaffe T.A., Gaca A.M., Delaney S., et al. Radiation doses from small-bowel follow-through and abdominopelvic MDCT in Crohn's disease. AJR Am J Roentgenol 189 (2007) 1015-1022
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 1015-1022
    • Jaffe, T.A.1    Gaca, A.M.2    Delaney, S.3
  • 15
    • 0003733263 scopus 로고
    • Recommendations of the International Commission on Radiological Protection
    • International Commission on Radiological Protection, Pergamon, Oxford, UK
    • International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. ICRP Publication 60 (1991), Pergamon, Oxford, UK
    • (1991) ICRP Publication 60
  • 16
    • 70349674442 scopus 로고    scopus 로고
    • The Phantom Laboratory, The Phantom Laboratory, Salem, NY Accessed June 15, 2009
    • ® 500 and 600 manual (2009), The Phantom Laboratory, Salem, NY. http://www.phantomlab.com/pdf/catphan500-600manual.pdf Accessed June 15, 2009
    • (2009) ® 500 and 600 manual
  • 17
    • 0018874804 scopus 로고
    • Increased tissue differentiation using color display of multiple-energy CT scans
    • Akutagawa W.M., Huth G.C., Levis R.E., Drianis G.C., and Davis R.L. Increased tissue differentiation using color display of multiple-energy CT scans. Radiology 134 (1980) 739-756
    • (1980) Radiology , vol.134 , pp. 739-756
    • Akutagawa, W.M.1    Huth, G.C.2    Levis, R.E.3    Drianis, G.C.4    Davis, R.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.