메뉴 건너뛰기




Volumn 17, Issue 10, 2010, Pages 1203-1210

Feasibility of dose reduction using novel denoising techniques for low kV (80 kV) CT enterography. Optimization and validation

Author keywords

Bilateral filtering; CT enterography, low energy CT; Image denoising; Image noise; Image quality; Noise reduction; Projection space algorithms; Radiation dose

Indexed keywords

IOHEXOL; UNCLASSIFIED DRUG; VOLUMEN;

EID: 77956464589     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2010.07.001     Document Type: Article
Times cited : (31)

References (23)
  • 1
    • 56149126478 scopus 로고    scopus 로고
    • Medical radiation exposure in the U.S. in 2006: preliminary results
    • Mettler F.A., Thomadsen B.R., Bhargavan M., et al. Medical radiation exposure in the U.S. in 2006: preliminary results. Health Phys 2008, 95:502-507.
    • (2008) Health Phys , vol.95 , pp. 502-507
    • Mettler, F.A.1    Thomadsen, B.R.2    Bhargavan, M.3
  • 2
    • 0842348097 scopus 로고    scopus 로고
    • Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
    • Berrington de Gonzalez A., Darby S. Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet 2004, 363:345-351.
    • (2004) Lancet , vol.363 , pp. 345-351
    • Berrington de Gonzalez, A.1    Darby, S.2
  • 3
    • 27744501240 scopus 로고    scopus 로고
    • Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise
    • Nakayama Y., Awai K., Funama Y., et al. Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology 2005, 237:945-951.
    • (2005) Radiology , vol.237 , pp. 945-951
    • Nakayama, Y.1    Awai, K.2    Funama, Y.3
  • 4
    • 44449089365 scopus 로고    scopus 로고
    • Effect of X-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study
    • Szucs-Farkas Z., Verdun F.R., von Allmen G., Mini R.L., Vock P. Effect of X-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study. Invest Radiol 2008, 43:374-381.
    • (2008) Invest Radiol , vol.43 , pp. 374-381
    • Szucs-Farkas, Z.1    Verdun, F.R.2    von Allmen, G.3    Mini, R.L.4    Vock, P.5
  • 5
    • 31144476744 scopus 로고    scopus 로고
    • Crohn disease: mural attenuation and thickness at contrast-enhanced CT enterography-correlation with endoscopic and histologic findings of inflammation
    • Bodily K.D., Fletcher J.G., Solem C.A., et al. Crohn disease: mural attenuation and thickness at contrast-enhanced CT enterography-correlation with endoscopic and histologic findings of inflammation. Radiology 2006, 238:505-516.
    • (2006) Radiology , vol.238 , pp. 505-516
    • Bodily, K.D.1    Fletcher, J.G.2    Solem, C.A.3
  • 6
    • 7044228012 scopus 로고    scopus 로고
    • Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape
    • Siegel M.J., Schmidt B., Bradley D., Suess C., Hildebolt C. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology 2004, 233:515-522.
    • (2004) Radiology , vol.233 , pp. 515-522
    • Siegel, M.J.1    Schmidt, B.2    Bradley, D.3    Suess, C.4    Hildebolt, C.5
  • 7
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
    • Hsieh J. Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. Med Phys 1998, 25:2139-2147.
    • (1998) Med Phys , vol.25 , pp. 2139-2147
    • Hsieh, J.1
  • 8
    • 4143148392 scopus 로고    scopus 로고
    • Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters
    • Kalra M.K., Maher M.M., Blake M.A., et al. Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology 2004, 232:791-797.
    • (2004) Radiology , vol.232 , pp. 791-797
    • Kalra, M.K.1    Maher, M.M.2    Blake, M.A.3
  • 9
    • 0037600583 scopus 로고    scopus 로고
    • Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study
    • Kalra M.K., Maher M.M., Sahani D.V., et al. Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study. Radiology 2003, 228:251-256.
    • (2003) Radiology , vol.228 , pp. 251-256
    • Kalra, M.K.1    Maher, M.M.2    Sahani, D.V.3
  • 10
    • 33746927954 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram restoration for computed tomography
    • La Riviere P.J., Bian J., Vargas P.A. Penalized-likelihood sinogram restoration for computed tomography. IEEE Trans Med Imaging 2006, 25:1022-1036.
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 1022-1036
    • La Riviere, P.J.1    Bian, J.2    Vargas, P.A.3
  • 11
    • 25144432836 scopus 로고    scopus 로고
    • CT images of abdomen and pelvis: effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics
    • Rizzo S.M., Kalra M.K., Schmidt B., et al. CT images of abdomen and pelvis: effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics. Radiology 2005, 237:309-315.
    • (2005) Radiology , vol.237 , pp. 309-315
    • Rizzo, S.M.1    Kalra, M.K.2    Schmidt, B.3
  • 12
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose x-ray computed tomography
    • Wang J.L.T., Lu H., Liang Z. Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose x-ray computed tomography. IEEE Trans Med Imaging 2006, 25:1272-1283.
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 1272-1283
    • Wang, J.L.T.1    Lu, H.2    Liang, Z.3
  • 13
    • 70350705569 scopus 로고    scopus 로고
    • Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT
    • Manduca A., Yu L., Trzasko J.D., et al. Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT. Med Phys 2009, 36:4911-4919.
    • (2009) Med Phys , vol.36 , pp. 4911-4919
    • Manduca, A.1    Yu, L.2    Trzasko, J.D.3
  • 14
    • 0025465145 scopus 로고
    • Scale-space and edge detection using anisotropic diffusion
    • Perona P., Malik J. Scale-space and edge detection using anisotropic diffusion. IEEE Trans Patt Anal Mach Intell 1990, 12:629-639.
    • (1990) IEEE Trans Patt Anal Mach Intell , vol.12 , pp. 629-639
    • Perona, P.1    Malik, J.2
  • 15
    • 0001243836 scopus 로고
    • The transformation of Poisson, binomial and negative binomial data
    • Anscombe J. The transformation of Poisson, binomial and negative binomial data. Biometrika 1948, 15:246-254.
    • (1948) Biometrika , vol.15 , pp. 246-254
    • Anscombe, J.1
  • 17
    • 0034936105 scopus 로고    scopus 로고
    • Radiation dose management: weighing risk versus benefit
    • Haaga J.R. Radiation dose management: weighing risk versus benefit. AJR Am J Roentgenol 2001, 177:289-291.
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 289-291
    • Haaga, J.R.1
  • 18
    • 2342531080 scopus 로고    scopus 로고
    • Correlation of patient weight and cross-sectional dimensions with subjective image quality at standard dose abdominal CT
    • Kalra M.K., Maher M.M., Prasad S.R., et al. Correlation of patient weight and cross-sectional dimensions with subjective image quality at standard dose abdominal CT. Korean J Radiol 2003, 4:234-238.
    • (2003) Korean J Radiol , vol.4 , pp. 234-238
    • Kalra, M.K.1    Maher, M.M.2    Prasad, S.R.3
  • 19
    • 49349095292 scopus 로고    scopus 로고
    • Diagnostic ionizing radiation exposure in a population-based cohort of patients with inflammatory bowel disease
    • Peloquin J.M., Pardi D.S., Sandborn W.J., et al. Diagnostic ionizing radiation exposure in a population-based cohort of patients with inflammatory bowel disease. Am J Gastroenterol 2008, 103:2015-2022.
    • (2008) Am J Gastroenterol , vol.103 , pp. 2015-2022
    • Peloquin, J.M.1    Pardi, D.S.2    Sandborn, W.J.3
  • 20
    • 21144458117 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram smoothing for low-dose CT
    • La Riviere P.J. Penalized-likelihood sinogram smoothing for low-dose CT. Med Phys 2005, 32:1676-1683.
    • (2005) Med Phys , vol.32 , pp. 1676-1683
    • La Riviere, P.J.1
  • 21
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • Kachelriess M., Watzke O., Kalender W.A. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT. Med Phys 2001, 28:475-490.
    • (2001) Med Phys , vol.28 , pp. 475-490
    • Kachelriess, M.1    Watzke, O.2    Kalender, W.A.3
  • 22
    • 34247485310 scopus 로고    scopus 로고
    • Multi-detector row CT of the small bowel: peak enhancement temporal window-initial experience
    • Schindera S.T., Nelson R.C., DeLong D.M., et al. Multi-detector row CT of the small bowel: peak enhancement temporal window-initial experience. Radiology 2007, 243:438-444.
    • (2007) Radiology , vol.243 , pp. 438-444
    • Schindera, S.T.1    Nelson, R.C.2    DeLong, D.M.3
  • 23
    • 73649148717 scopus 로고    scopus 로고
    • Automatic selection of tube potential for radiation dose reduction in CT: a general strategy
    • Yu L., Li H., Fletcher J.G., McCollough C.H. Automatic selection of tube potential for radiation dose reduction in CT: a general strategy. Med Phys 2010, 37:234-243.
    • (2010) Med Phys , vol.37 , pp. 234-243
    • Yu, L.1    Li, H.2    Fletcher, J.G.3    McCollough, C.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.