메뉴 건너뛰기




Volumn 195, Issue 1, 2010, Pages 89-100

Effect of altering automatic exposure control settings and quality reference mAs on radiation dose, image quality, and diagnostic efficacy in MDCT enterography of active inflammatory Crohn's disease

Author keywords

Crohn's disease; CT enterography; Dose reduction

Indexed keywords

ADULT; AGED; ARTICLE; COHORT ANALYSIS; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CROHN DISEASE; DEMOGRAPHY; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; ILEUM; IMAGE QUALITY; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIATION DOSE;

EID: 77954691805     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.09.3611     Document Type: Article
Times cited : (75)

References (30)
  • 1
    • 0036161786 scopus 로고    scopus 로고
    • The epidemiology and natural history of Crohn's disease in population-based patient cohorts from North America: A systematic review
    • Loftus EV Jr, Schoenfeld P, Sandborn WJ. The epidemiology and natural history of Crohn's disease in population-based patient cohorts from North America: a systematic review. Aliment Pharmacol Ther 2002; 16:51-60
    • (2002) Aliment Pharmacol Ther , vol.16 , pp. 51-60
    • Loftus Jr., E.V.1    Schoenfeld, P.2    Sandborn, W.J.3
  • 2
    • 35948998089 scopus 로고    scopus 로고
    • CT enterography for Crohn's disease: Accurate preoperative diagnostic imaging
    • Vogel J, da Luz Moreira A, Baker M, et al. CT enterography for Crohn's disease: accurate preoperative diagnostic imaging. Dis Colon Rectum 2007; 50:1761-1769
    • (2007) Dis Colon Rectum , vol.50 , pp. 1761-1769
    • Vogel, J.1    Da Luz Moreira, A.2    Baker, M.3
  • 3
    • 68549118910 scopus 로고    scopus 로고
    • CT enterography and fistulizing Crohn's disease: Clinical benefit and radiographic findings
    • Booya F, Akram S, Fletcher JG, et al. CT enterography and fistulizing Crohn's disease: clinical benefit and radiographic findings. Abdom Imaging 2009; 34:467-475
    • (2009) Abdom Imaging , vol.34 , pp. 467-475
    • Booya, F.1    Akram, S.2    Fletcher, J.G.3
  • 4
    • 0141741401 scopus 로고    scopus 로고
    • Assessment of small bowel Crohn disease: Noninvasive peroral CT enterography compared with other imaging methods and endoscopy - Feasibility study
    • Wold PB, Fletcher JG, Johnson CD, Sandborn WJ. Assessment of small bowel Crohn disease: noninvasive peroral CT enterography compared with other imaging methods and endoscopy - feasibility study. Radiology 2003; 229:275-281
    • (2003) Radiology , vol.229 , pp. 275-281
    • Wold, P.B.1    Fletcher, J.G.2    Johnson, C.D.3    Sandborn, W.J.4
  • 5
    • 44849142672 scopus 로고    scopus 로고
    • Using CT enterography to monitor Crohn's disease activity: A preliminary study
    • Hara AK, Alam S, Heigh RI, Gurudu SR, Hentz JG, Leighton JA. Using CT enterography to monitor Crohn's disease activity: a preliminary study. AJR 2008; 190:1512-1516
    • (2008) AJR , vol.190 , pp. 1512-1516
    • Hara, A.K.1    Alam, S.2    Heigh, R.I.3    Gurudu, S.R.4    Hentz, J.G.5    Leighton, J.A.6
  • 6
    • 33744749208 scopus 로고    scopus 로고
    • CT enterography as a diagnostic tool in evaluating small bowel disorders: Review of clinical experience with over 700 cases
    • Paulsen SR, Huprich JE, Fletcher JG, et al. CT enterography as a diagnostic tool in evaluating small bowel disorders: review of clinical experience with over 700 cases. RadioGraphics 2006; 26:641-662
    • (2006) RadioGraphics , vol.26 , pp. 641-662
    • Paulsen, S.R.1    Huprich, J.E.2    Fletcher, J.G.3
  • 7
    • 31144476744 scopus 로고    scopus 로고
    • Crohn disease: Mural attenuation and thickness at contrast-enhanced CT enterography - Correlation with endoscopic and histologic findings of inflammation
    • Bodily KD, Fletcher JG, Solem CA, et al. Crohn disease: mural attenuation and thickness at contrast-enhanced CT enterography - correlation with endoscopic and histologic findings of inflammation. Radiology 2006; 238:505-516
    • (2006) Radiology , vol.238 , pp. 505-516
    • Bodily, K.D.1    Fletcher, J.G.2    Solem, C.A.3
  • 9
    • 29444452702 scopus 로고    scopus 로고
    • Crohn disease of the small bowel: Preliminary comparison among CT enterography, capsule endoscopy, small-bowel follow-through, and ileoscopy
    • Hara AK, Leighton JA, Heigh RI, et al. Crohn disease of the small bowel: preliminary comparison among CT enterography, capsule endoscopy, small-bowel follow-through, and ileoscopy. Radiology 2006; 238:128-134
    • (2006) Radiology , vol.238 , pp. 128-134
    • Hara, A.K.1    Leighton, J.A.2    Heigh, R.I.3
  • 10
    • 59349084707 scopus 로고    scopus 로고
    • Mural attenuation in normal small bowel and active inflammatory Crohn's disease on CT enterography: Location, absolute attenuation, relative attenuation, and the effect of wall thickness
    • Baker ME, Walter J, Obuchowski NA, et al. Mural attenuation in normal small bowel and active inflammatory Crohn's disease on CT enterography: location, absolute attenuation, relative attenuation, and the effect of wall thickness. AJR 2009; 192:417-423
    • (2009) AJR , vol.192 , pp. 417-423
    • Baker, M.E.1    Walter, J.2    Obuchowski, N.A.3
  • 11
    • 54349083883 scopus 로고    scopus 로고
    • Crohn's disease: Factors associated with exposure to high levels of diagnostic radiation
    • Desmond AN, O'Regan K, Curran C, et al. Crohn's disease: factors associated with exposure to high levels of diagnostic radiation. Gut 2008; 57:1524-1529
    • (2008) Gut , vol.57 , pp. 1524-1529
    • Desmond, A.N.1    O'Regan, K.2    Curran, C.3
  • 12
    • 35649009454 scopus 로고    scopus 로고
    • Radiation doses from small-bowel follow-through and abdominopelvic MDCT in Crohn's disease
    • Jaffe TA, Gaca AM, Delaney S, et al. Radiation doses from small-bowel follow-through and abdominopelvic MDCT in Crohn's disease. AJR 2007; 189:1015-1022
    • (2007) AJR , vol.189 , pp. 1015-1022
    • Jaffe, T.A.1    Gaca, A.M.2    Delaney, S.3
  • 13
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography: An increasing source of radiation exposure
    • Brenner DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med 2007; 357:2277-2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 14
    • 1342266221 scopus 로고    scopus 로고
    • Strategies for CT radiation dose optimization
    • Kalra MK, Maher MM, Toth TL, et al. Strategies for CT radiation dose optimization. Radiology 2004; 230:619-628
    • (2004) Radiology , vol.230 , pp. 619-628
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 16
    • 3042791578 scopus 로고    scopus 로고
    • Computed tomography
    • Bushberg JT, Seibert A, Leidholdt EM Jr, Boone JM, eds. 2nd ed. Philadelphia, PA: Lippincott Williams & Wilkins
    • Bushberg JT, Seibert JA, Leidholdt EM Jr, Boone JM. Computed tomography. In: Bushberg JT, Seibert A, Leidholdt EM Jr, Boone JM, eds. The essential physics of medical imaging, 2nd ed. Philadelphia, PA: Lippincott Williams & Wilkins, 2002:327-372
    • (2002) The Essential Physics of Medical Imaging , pp. 327-372
    • Bushberg, J.T.1    Seibert, J.A.2    Leidholdt Jr., E.M.3    Boone, J.M.4
  • 18
    • 13244297711 scopus 로고    scopus 로고
    • Techniques and applications of automatic tube current modulation for CT
    • Kalra MK, Maher MM, Toth TL, et al. Techniques and applications of automatic tube current modulation for CT. Radiology 2004; 233:649-657
    • (2004) Radiology , vol.233 , pp. 649-657
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 19
    • 23944456572 scopus 로고    scopus 로고
    • Computed tomography radiation dose optimization: Scanning protocols and clinical applications of automatic exposure control
    • Kalra MK, Naz N, Rizzo SM, Blake MA. Computed tomography radiation dose optimization: scanning protocols and clinical applications of automatic exposure control. Curr Probl Diagn Radiol 2005; 34:171-181
    • (2005) Curr Probl Diagn Radiol , vol.34 , pp. 171-181
    • Kalra, M.K.1    Naz, N.2    Rizzo, S.M.3    Blake, M.A.4
  • 20
    • 25144433343 scopus 로고    scopus 로고
    • Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation
    • Mulkens TH, Bellinck P, Baeyaert M, et al. Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 2005; 237:213-223
    • (2005) Radiology , vol.237 , pp. 213-223
    • Mulkens, T.H.1    Bellinck, P.2    Baeyaert, M.3
  • 21
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. RadioGraphics 2006; 26:503-512
    • (2006) RadioGraphics , vol.26 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3
  • 22
    • 49149102462 scopus 로고    scopus 로고
    • Pediatric body MDCT: A 5-year follow-up survey of scanning parameters used by pediatric radiologists
    • Arch ME, Frush DP. Pediatric body MDCT: a 5-year follow-up survey of scanning parameters used by pediatric radiologists. AJR 2008; 191:611-617
    • (2008) AJR , vol.191 , pp. 611-617
    • Arch, M.E.1    Frush, D.P.2
  • 23
    • 0036943726 scopus 로고    scopus 로고
    • Strategies of dose reduction
    • Frush DP. Strategies of dose reduction. Pediatr Radiol 2002; 32:293-297
    • (2002) Pediatr Radiol , vol.32 , pp. 293-297
    • Frush, D.P.1
  • 25
    • 77954703466 scopus 로고    scopus 로고
    • CARE Dose4D: New techniques for radiation dose reduction
    • Website. Accessed March 18, 2010
    • Kalra MK, Brady TJ. CARE Dose4D: new techniques for radiation dose reduction. SOMATOM 2006. Siemens Healthcare Website. www.medical.siemens.com/ siemens/de-DE/rg-marcom-FBAs/files/news/CT-Dose-Reduction/DoseReduction- Sessions-19-RSNA-DRUCK.pdf. Accessed March 18, 2010
    • SOMATOM 2006
    • Kalra, M.K.1    Brady, T.J.2
  • 26
    • 0032528036 scopus 로고    scopus 로고
    • On the comparison of correlated proportions for clustered data
    • Obuchowski NA. On the comparison of correlated proportions for clustered data. Stat Med 1998; 17:1495-1507
    • (1998) Stat Med , vol.17 , pp. 1495-1507
    • Obuchowski, N.A.1
  • 27
    • 0038437326 scopus 로고    scopus 로고
    • Website. Accessed March 18, 2010
    • Metz C, et al. ROC analysis. Johns Hopkins Medical Center Website. www.rad.jhmi.edu/jeng/javarad/roc-old/JROCFITi.html. Accessed March 18, 2010
    • ROC Analysis
    • Metz, C.1
  • 28
    • 44449085865 scopus 로고    scopus 로고
    • Radiation dose reduction strategies for CT protocols: Successful implementation in neuroradiology section
    • Smith AB, Dillon WP, Lau BC, et al. Radiation dose reduction strategies for CT protocols: successful implementation in neuroradiology section. Radiology 2008; 247:499-506
    • (2008) Radiology , vol.247 , pp. 499-506
    • Smith, A.B.1    Dillon, W.P.2    Lau, B.C.3
  • 30
    • 26044445862 scopus 로고    scopus 로고
    • Patient circumference-adapted dose regulation in body computed tomography: A practical and flexible formula
    • Nyman U, Ahl TL, Kristiansson M, Nilsson L, Wettemark S. Patient circumference-adapted dose regulation in body computed tomography: a practical and flexible formula. Acta Radiol 2005; 46:396-406
    • (2005) Acta Radiol , vol.46 , pp. 396-406
    • Nyman, U.1    Ahl, T.L.2    Kristiansson, M.3    Nilsson, L.4    Wettemark, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.