메뉴 건너뛰기




Volumn , Issue , 2008, Pages 194-233

Biocompatibility of Nitinol for biomedical applications

Author keywords

[No Author keywords available]

Indexed keywords

BINARY ALLOYS; BIOLOGY; MEDICAL APPLICATIONS; TEMPERATURE; TITANIUM ALLOYS;

EID: 77955766132     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1533/9781845695248.1.194     Document Type: Chapter
Times cited : (31)

References (127)
  • 1
    • 0029312264 scopus 로고
    • Allergic reaction to nickel (Nitinol) orthodontic wires: A case report
    • Al-Waheidi E. Allergic reaction to nickel (Nitinol) orthodontic wires: A case report. Quinte Int 1995, 26(6):385-388.
    • (1995) Quinte Int , vol.26 , Issue.6 , pp. 385-388
    • Al-Waheidi, E.1
  • 2
    • 0141670820 scopus 로고    scopus 로고
    • Biocompatibility and haemocompatibility of surface-modified Ti-Ni alloys
    • Armitage D., Parker T., Grant D. Biocompatibility and haemocompatibility of surface-modified Ti-Ni alloys. J Biomed Mater Res 2003, 66A:129-137.
    • (2003) J Biomed Mater Res , vol.66 A , pp. 129-137
    • Armitage, D.1    Parker, T.2    Grant, D.3
  • 3
    • 0142133589 scopus 로고    scopus 로고
    • Porous Titanium-Nickel for intervertebral fusion in a sheep model: Part 1. Histomorphometric and radiological analysis
    • Assad M., Jarzem P., Leroux M., Cillard C., Chernyshov A., Charette S., Rivard C. Porous Titanium-Nickel for intervertebral fusion in a sheep model: Part 1. Histomorphometric and radiological analysis. J Biomed Mater Res 2003, 64B:107-120.
    • (2003) J Biomed Mater Res , vol.64 B , pp. 107-120
    • Assad, M.1    Jarzem, P.2    Leroux, M.3    Cillard, C.4    Chernyshov, A.5    Charette, S.6    Rivard, C.7
  • 4
    • 0142101894 scopus 로고    scopus 로고
    • Porous Titanium-Nickel for intervertebral fusion in a sheep model: Part 2. Surface analysis and nickel release assessment
    • Assad M., Chernyshov A., Jarzem P., Leroux M., Cillard C., Charette S., Rivard C. Porous Titanium-Nickel for intervertebral fusion in a sheep model: Part 2. Surface analysis and nickel release assessment. J Biomed Mater Res 2003, 64B:121-129.
    • (2003) J Biomed Mater Res , vol.64 B , pp. 121-129
    • Assad, M.1    Chernyshov, A.2    Jarzem, P.3    Leroux, M.4    Cillard, C.5    Charette, S.6    Rivard, C.7
  • 5
    • 0033118501 scopus 로고    scopus 로고
    • Effect of Nitinol implant porosity on cranial bone ingrowth and apposition after 6 weeks
    • Ayers R., Simske S., Bateman T., Petkus A., Sachdeva R., Gyunter V. Effect of Nitinol implant porosity on cranial bone ingrowth and apposition after 6 weeks. J Biomed Mater Res 1999, 45:42-47.
    • (1999) J Biomed Mater Res , vol.45 , pp. 42-47
    • Ayers, R.1    Simske, S.2    Bateman, T.3    Petkus, A.4    Sachdeva, R.5    Gyunter, V.6
  • 6
    • 12544254586 scopus 로고    scopus 로고
    • Biocompatibility of Nitinol and stainless steel in the bladder: an experimental study
    • Balakrishnan N., Uvelius B., Zaszczurynski P., Lin D., Damasker M. Biocompatibility of Nitinol and stainless steel in the bladder: an experimental study. J Urol 2005, 173:647-650.
    • (2005) J Urol , vol.173 , pp. 647-650
    • Balakrishnan, N.1    Uvelius, B.2    Zaszczurynski, P.3    Lin, D.4    Damasker, M.5
  • 7
    • 0030983642 scopus 로고    scopus 로고
    • Early and late results of self-expandable Nitinol stents: Interim report from multicenter European study
    • Bayer R., Roguin A. Early and late results of self-expandable Nitinol stents: Interim report from multicenter European study. J Interven Cardiol 1997, 10:207-213.
    • (1997) J Interven Cardiol , vol.10 , pp. 207-213
    • Bayer, R.1    Roguin, A.2
  • 8
    • 0030270078 scopus 로고    scopus 로고
    • Biocompatibility testing of Ti-Ni screws using immunohistochemistry of section containing metallic implants
    • Berger-Gorbet M., Broxup B., Rivard C., Yahia L. Biocompatibility testing of Ti-Ni screws using immunohistochemistry of section containing metallic implants. J Biomed Mater Res 1996, 32:243-248.
    • (1996) J Biomed Mater Res , vol.32 , pp. 243-248
    • Berger-Gorbet, M.1    Broxup, B.2    Rivard, C.3    Yahia, L.4
  • 11
    • 33746069408 scopus 로고    scopus 로고
    • Does the nanometer scale topography of titanium influence protein adsorption and cell proliferation?
    • Cai K., Bossert J., Jandt K. Does the nanometer scale topography of titanium influence protein adsorption and cell proliferation?. Colloids and Surfaces 2006, 49:136-144.
    • (2006) Colloids and Surfaces , vol.49 , pp. 136-144
    • Cai, K.1    Bossert, J.2    Jandt, K.3
  • 12
    • 0036481881 scopus 로고    scopus 로고
    • Device migration after endolumenal abdominal aortic aneurysm repair: analysis of 113 cases with minimum follow-up period of two years
    • Cao P., Verzini S., Zannetti S. Device migration after endolumenal abdominal aortic aneurysm repair: analysis of 113 cases with minimum follow-up period of two years. J Vasc Surg 2002, 35:229-235.
    • (2002) J Vasc Surg , vol.35 , pp. 229-235
    • Cao, P.1    Verzini, S.2    Zannetti, S.3
  • 15
    • 33644782777 scopus 로고    scopus 로고
    • The corrosion behavior and hemocompatibility of TiNi alloys coated with DLC by plasma based ion implantation
    • Cheng Y., Zheng Y. The corrosion behavior and hemocompatibility of TiNi alloys coated with DLC by plasma based ion implantation. Surf Coat Technol 2006, 200:4543-4548.
    • (2006) Surf Coat Technol , vol.200 , pp. 4543-4548
    • Cheng, Y.1    Zheng, Y.2
  • 16
    • 0038462111 scopus 로고    scopus 로고
    • Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets
    • Choi J., Bogdanski D., Köller M., Esenwein S.A., Müller D., Muhr G., Epple M. Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets. Biomaterials 2003, 24:3689-3696.
    • (2003) Biomaterials , vol.24 , pp. 3689-3696
    • Choi, J.1    Bogdanski, D.2    Köller, M.3    Esenwein, S.A.4    Müller, D.5    Muhr, G.6    Epple, M.7
  • 17
    • 0037026414 scopus 로고    scopus 로고
    • Effect of surface treatment of Ti-Ni alloy on its corrosion behavior in Hanks' solution
    • Cisse O., Savagodo O., Wu M., Yahia L. Effect of surface treatment of Ti-Ni alloy on its corrosion behavior in Hanks' solution. J Biomed Mater Res 2002, 61:339-345.
    • (2002) J Biomed Mater Res , vol.61 , pp. 339-345
    • Cisse, O.1    Savagodo, O.2    Wu, M.3    Yahia, L.4
  • 18
    • 33748999537 scopus 로고    scopus 로고
    • Influence of Nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release
    • Clarke B., Carroll W., Rochev Y., Hynes M., Bradley D., Plumley D. Influence of Nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release. J Biomed Mater Res 2006, 79A:61-70.
    • (2006) J Biomed Mater Res , vol.79 A , pp. 61-70
    • Clarke, B.1    Carroll, W.2    Rochev, Y.3    Hynes, M.4    Bradley, D.5    Plumley, D.6
  • 20
    • 0003867545 scopus 로고    scopus 로고
    • Bulk properties of materials
    • Academic Press, Boston, B. Ratner, A. Hoffman, F. Schoen, J. Lemons (Eds.)
    • Cooke F. Bulk properties of materials. Biomaterials Science 2000, 11-35. Academic Press, Boston. B. Ratner, A. Hoffman, F. Schoen, J. Lemons (Eds.).
    • (2000) Biomaterials Science , pp. 11-35
    • Cooke, F.1
  • 21
    • 0027361059 scopus 로고
    • Nitinol intravascular stent: results of preclinical evaluation
    • Cragg A., De Jong C., Barnhart W., Landas S., Smith T. Nitinol intravascular stent: results of preclinical evaluation. Radiology 1993, 189:775-778.
    • (1993) Radiology , vol.189 , pp. 775-778
    • Cragg, A.1    De Jong, C.2    Barnhart, W.3    Landas, S.4    Smith, T.5
  • 22
    • 0014579216 scopus 로고
    • Transluminally-placed coil-spring endarterial tube grafts
    • Dotter C. Transluminally-placed coil-spring endarterial tube grafts. Invest Radiol 1969, 4:329-332.
    • (1969) Invest Radiol , vol.4 , pp. 329-332
    • Dotter, C.1
  • 23
    • 76549154241 scopus 로고
    • Transluminal treatment of arteriosclerotic obstruction
    • Dotter C., Judkins M. Transluminal treatment of arteriosclerotic obstruction. Circulation 1964, 30:654-660.
    • (1964) Circulation , vol.30 , pp. 654-660
    • Dotter, C.1    Judkins, M.2
  • 24
    • 0028470873 scopus 로고
    • Cell damage in vitro following direct contact with fine particles of titanium, titanium alloy and cobalt-chrome-molybdenum alloy
    • Evans E. Cell damage in vitro following direct contact with fine particles of titanium, titanium alloy and cobalt-chrome-molybdenum alloy. Biomaterials 1994, 15:713-717.
    • (1994) Biomaterials , vol.15 , pp. 713-717
    • Evans, E.1
  • 25
    • 0003492744 scopus 로고
    • Gordon and Breach Science Publishers
    • Funakubo H. Shape memory alloys 1984, Gordon and Breach Science Publishers.
    • (1984) Shape memory alloys
    • Funakubo, H.1
  • 28
    • 0032892654 scopus 로고    scopus 로고
    • Sheep, pig, and human platelet-material interactions with model cardiovascular devices
    • Goodman S. Sheep, pig, and human platelet-material interactions with model cardiovascular devices. J Biomed Mater Res 1999, 45:240-250.
    • (1999) J Biomed Mater Res , vol.45 , pp. 240-250
    • Goodman, S.1
  • 29
    • 0027996127 scopus 로고
    • Self-expandable and highly flexible Nitinol stent: immediate and long-term results in dogs
    • Grenadier E., Shofti R., Beyer M., Beyer R. Self-expandable and highly flexible Nitinol stent: immediate and long-term results in dogs. Am Heart J 1994, 128:87-878.
    • (1994) Am Heart J , vol.128 , pp. 87-878
    • Grenadier, E.1    Shofti, R.2    Beyer, M.3    Beyer, R.4
  • 30
    • 0033865287 scopus 로고    scopus 로고
    • First-generation aortic endiografts: Analysis of explanted Stentor devices from the EUROSTAR registry
    • Guidon R., et al. First-generation aortic endiografts: Analysis of explanted Stentor devices from the EUROSTAR registry. J Endovasc Ther 2000, 7:105-122.
    • (2000) J Endovasc Ther , vol.7 , pp. 105-122
    • Guidon, R.1
  • 35
    • 0029114616 scopus 로고
    • Palmaz stent placement in iliac and femopopliteal arteries: primary and second patency in 310 patients with 2-4 year follow-up
    • Henry M., Amor M., Ethevenot G., Henry I., Amicabile C., Beron R., Mentre B., Allaoui M., Touchot N. Palmaz stent placement in iliac and femopopliteal arteries: primary and second patency in 310 patients with 2-4 year follow-up. Radiology 1995, 197:167-174.
    • (1995) Radiology , vol.197 , pp. 167-174
    • Henry, M.1    Amor, M.2    Ethevenot, G.3    Henry, I.4    Amicabile, C.5    Beron, R.6    Mentre, B.7    Allaoui, M.8    Touchot, N.9
  • 36
    • 42949151430 scopus 로고    scopus 로고
    • Effect of martensitic transformation on the performance of coated Ti-Ni surfaces
    • 10.1016/j.msea.2007.09.029.
    • Hebling C., Frenzel J., Pohl M., Shabalovskaya S., et al. Effect of martensitic transformation on the performance of coated Ti-Ni surfaces. Mater Sci Eng 2007, 10.1016/j.msea.2007.09.029.
    • (2007) Mater Sci Eng
    • Hebling, C.1    Frenzel, J.2    Pohl, M.3    Shabalovskaya, S.4
  • 37
    • 0030981815 scopus 로고    scopus 로고
    • Acute and chronic effects of self-expanding Nitiniol stents in porcine coronary arteries
    • Hong M., Beyer R., Kornowski R., Tio F., Bramwell O., Leon M. Acute and chronic effects of self-expanding Nitiniol stents in porcine coronary arteries. Coron Artery Dis 1997, 8:45-48.
    • (1997) Coron Artery Dis , vol.8 , pp. 45-48
    • Hong, M.1    Beyer, R.2    Kornowski, R.3    Tio, F.4    Bramwell, O.5    Leon, M.6
  • 38
    • 0001908637 scopus 로고    scopus 로고
    • Dynamic of ingrowth of living tissues in porous permeable implant. Mechanical behavior of the Nitinol-living tissue composite
    • Itin V., Gyunter V., Khodorenko V., Chobanyan M., Mirgazizov M., Korsteleva E., Belyalova M. Dynamic of ingrowth of living tissues in porous permeable implant. Mechanical behavior of the Nitinol-living tissue composite. Letters J Tech Phys 1996, 22(6):37-42.
    • (1996) Letters J Tech Phys , vol.22 , Issue.6 , pp. 37-42
    • Itin, V.1    Gyunter, V.2    Khodorenko, V.3    Chobanyan, M.4    Mirgazizov, M.5    Korsteleva, E.6    Belyalova, M.7
  • 41
    • 0036124328 scopus 로고    scopus 로고
    • Endovascular placement of self-expending Nitinol coil stents for the treatment of Femoropopliteal obstructive disease
    • Janke T., Voshage G., Müller-Hülsback S., Grimm J., Heller M., Brossmann J. Endovascular placement of self-expending Nitinol coil stents for the treatment of Femoropopliteal obstructive disease. J Vasc Interv Radiol 2002, 13:257-266.
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 257-266
    • Janke, T.1    Voshage, G.2    Müller-Hülsback, S.3    Grimm, J.4    Heller, M.5    Brossmann, J.6
  • 43
    • 0035312808 scopus 로고    scopus 로고
    • Long-term vessel response of self-expending coronary stent: A serial volumetric intravascular ultrasound analysis from the ASSURE trial
    • Kobayashi Y., et al. Long-term vessel response of self-expending coronary stent: A serial volumetric intravascular ultrasound analysis from the ASSURE trial. J Am College Cardiol 2001, 37(5):1329-1334.
    • (2001) J Am College Cardiol , vol.37 , Issue.5 , pp. 1329-1334
    • Kobayashi, Y.1
  • 46
    • 0034597889 scopus 로고    scopus 로고
    • Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
    • Koster R., Vieluf D., Kiehn M., Sommerauer M., Kahler J., Baldus S., Meinertz T. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 2000, 356:1895-1897.
    • (2000) Lancet , vol.356 , pp. 1895-1897
    • Koster, R.1    Vieluf, D.2    Kiehn, M.3    Sommerauer, M.4    Kahler, J.5    Baldus, S.6    Meinertz, T.7
  • 48
    • 0042388582 scopus 로고    scopus 로고
    • Effect of porosity on osteointegration and bone ingrowth of a weight bearing nickel-titanium bone graft substitute
    • Kujala S., Ryhänen J., Danilov A., Tuukkanen J. Effect of porosity on osteointegration and bone ingrowth of a weight bearing nickel-titanium bone graft substitute. Biomaterials 2003, 24:4691-4697.
    • (2003) Biomaterials , vol.24 , pp. 4691-4697
    • Kujala, S.1    Ryhänen, J.2    Danilov, A.3    Tuukkanen, J.4
  • 50
    • 0030270630 scopus 로고    scopus 로고
    • Distribution of nickel and cobalt following dermal and systematic administration with in vitro and in vivo studies
    • Lacy S., Meritt K., Brown S., Puryear A. Distribution of nickel and cobalt following dermal and systematic administration with in vitro and in vivo studies. J Biomed Mater Res 1996, 32:279-283.
    • (1996) J Biomed Mater Res , vol.32 , pp. 279-283
    • Lacy, S.1    Meritt, K.2    Brown, S.3    Puryear, A.4
  • 53
    • 0003043547 scopus 로고
    • Medical applications of Ni-Ti alloys in China
    • Butterworth-Heinemann, T. Duerig, K. Melton, D. Stoeckel, C. Wayman (Eds.)
    • Lu S. Medical applications of Ni-Ti alloys in China. Engineering aspects of shape memory alloys 1990, 445-451. Butterworth-Heinemann. T. Duerig, K. Melton, D. Stoeckel, C. Wayman (Eds.).
    • (1990) Engineering aspects of shape memory alloys , pp. 445-451
    • Lu, S.1
  • 54
    • 0018579798 scopus 로고    scopus 로고
    • Nickel-binding constituents of human blood serum
    • Lucassen M., Sarkar B. Nickel-binding constituents of human blood serum. J Toxic Environ Health 1997, 5:897-905.
    • (1997) J Toxic Environ Health , vol.5 , pp. 897-905
    • Lucassen, M.1    Sarkar, B.2
  • 55
    • 33645119700 scopus 로고    scopus 로고
    • Plasma-immersion ion-implanted Nitinol surface with depressed Ni concentration for implants in blood
    • Maitz M., Shevchenko N. Plasma-immersion ion-implanted Nitinol surface with depressed Ni concentration for implants in blood. J Biomed Mater Res 2006, 76A:356-365.
    • (2006) J Biomed Mater Res , vol.76 A , pp. 356-365
    • Maitz, M.1    Shevchenko, N.2
  • 56
    • 10744227472 scopus 로고    scopus 로고
    • Endovascular stent graft repair of abdominal and thoracic aortic aneurysms. A ten-year experience with 817 patients
    • Marin M., Hollier L., Ellozy S., Spielvogel D., Mitty H., Griepp R., et al. Endovascular stent graft repair of abdominal and thoracic aortic aneurysms. A ten-year experience with 817 patients. Ann Surg 2003, 238:586-595.
    • (2003) Ann Surg , vol.238 , pp. 586-595
    • Marin, M.1    Hollier, L.2    Ellozy, S.3    Spielvogel, D.4    Mitty, H.5    Griepp, R.6
  • 58
    • 0023179083 scopus 로고
    • Trace metal analysis in biocompatibility testing
    • CRC
    • Michel R. Trace metal analysis in biocompatibility testing. Crit. Rev Biocompat 1987, 3:235-317. CRC.
    • (1987) Crit. Rev Biocompat , vol.3 , pp. 235-317
    • Michel, R.1
  • 59
    • 33646356220 scopus 로고    scopus 로고
    • New oxidation treatment of Ti-Ni shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility
    • Michiardi A., Aparicio C., Planell J., Gil F. New oxidation treatment of Ti-Ni shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility. J Biomed Mater Res 2006, 77B:249-256.
    • (2006) J Biomed Mater Res , vol.77 B , pp. 249-256
    • Michiardi, A.1    Aparicio, C.2    Planell, J.3    Gil, F.4
  • 60
    • 33751032904 scopus 로고    scopus 로고
    • The influence of surface energy on competitive protein adsorption on oxidized Ti-Ni surfaces
    • Michiardi A., Aparicio C., Ratner B., Planell J., Gil J. The influence of surface energy on competitive protein adsorption on oxidized Ti-Ni surfaces. Biomaterials 2006, 29:586-594.
    • (2006) Biomaterials , vol.29 , pp. 586-594
    • Michiardi, A.1    Aparicio, C.2    Ratner, B.3    Planell, J.4    Gil, J.5
  • 61
    • 0002746585 scopus 로고    scopus 로고
    • Medical and dental applications of shape memory alloys
    • Cambridge University Press, K. Otzuka, C.M. Wayman (Eds.)
    • Miyazaki S. Medical and dental applications of shape memory alloys. Shape Memory Materials 1998, 267-281. Cambridge University Press. K. Otzuka, C.M. Wayman (Eds.).
    • (1998) Shape Memory Materials , pp. 267-281
    • Miyazaki, S.1
  • 63
    • 30344446344 scopus 로고    scopus 로고
    • Reduction effect of nickel ion release on diamond-like carbon film coated onto an orthodontic archwire
    • Ohgoe Y., Kobayashi S., Kobayashi O., Aoki H., Nakamori H., Hirakuri K. Reduction effect of nickel ion release on diamond-like carbon film coated onto an orthodontic archwire. Thin Solid Films 2006, 497:218-222.
    • (2006) Thin Solid Films , vol.497 , pp. 218-222
    • Ohgoe, Y.1    Kobayashi, S.2    Kobayashi, O.3    Aoki, H.4    Nakamori, H.5    Hirakuri, K.6
  • 64
    • 0032104453 scopus 로고    scopus 로고
    • Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V
    • Okazaki Y., Rao S., Ito Y., Tateishi T. Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V. Biomaterials 1998, 19:1197-1215.
    • (1998) Biomaterials , vol.19 , pp. 1197-1215
    • Okazaki, Y.1    Rao, S.2    Ito, Y.3    Tateishi, T.4
  • 66
    • 0036847067 scopus 로고    scopus 로고
    • Influence of stent design and material composition on procedure outcome
    • Article 36
    • Palmaz J., Bailey D., Marton D., Sprague E. Influence of stent design and material composition on procedure outcome. Basic Sci Rev 2002, 1031-1040. Article 36.
    • (2002) Basic Sci Rev , pp. 1031-1040
    • Palmaz, J.1    Bailey, D.2    Marton, D.3    Sprague, E.4
  • 67
    • 0034903696 scopus 로고    scopus 로고
    • Platelet interactions with titanium: modulation of platelet activity by surface topography
    • Park J., Gemmel H., Davies J. Platelet interactions with titanium: modulation of platelet activity by surface topography. Biomaterials 2001, 22:2671-2682.
    • (2001) Biomaterials , vol.22 , pp. 2671-2682
    • Park, J.1    Gemmel, H.2    Davies, J.3
  • 68
    • 0029039310 scopus 로고
    • Transfemoral endovascular stent graft repair of an abdominal aortic aneurysm
    • Parodi J., Marin M., Veuth F. Transfemoral endovascular stent graft repair of an abdominal aortic aneurysm. Arch Surg 1995, 130:549-552.
    • (1995) Arch Surg , vol.130 , pp. 549-552
    • Parodi, J.1    Marin, M.2    Veuth, F.3
  • 69
    • 34547888787 scopus 로고    scopus 로고
    • The release of nickel from orthodontic Ti-Ni wires is increased by dynamic mechanical loading but not constrained by surface nitridation
    • Peitsch T., Klocke A., Kahl-Nieke B., Prymak O., Epple M. The release of nickel from orthodontic Ti-Ni wires is increased by dynamic mechanical loading but not constrained by surface nitridation. J Biomed Mater Res 2007, 82A:731-739.
    • (2007) J Biomed Mater Res , vol.82 A , pp. 731-739
    • Peitsch, T.1    Klocke, A.2    Kahl-Nieke, B.3    Prymak, O.4    Epple, M.5
  • 70
    • 16344371208 scopus 로고    scopus 로고
    • Behavior of human endothelial cells on surface modified Ti-Ni alloy
    • Plant S., Grant D., Leach L. Behavior of human endothelial cells on surface modified Ti-Ni alloy. Biomaterials 2005, 26:5359-5367.
    • (2005) Biomaterials , vol.26 , pp. 5359-5367
    • Plant, S.1    Grant, D.2    Leach, L.3
  • 71
    • 0038118491 scopus 로고    scopus 로고
    • Relationship between surface properties (roughness, wettability) of titanium and titanium alloys and cell behaviour
    • Ponsonnet L., Reybier K., Jaffrezic N., Comte V., Lagneau C., Lissac M., Martelet C. Relationship between surface properties (roughness, wettability) of titanium and titanium alloys and cell behaviour. Mater Sci Eng 2003, 23C:551-560.
    • (2003) Mater Sci Eng , vol.23 C , pp. 551-560
    • Ponsonnet, L.1    Reybier, K.2    Jaffrezic, N.3    Comte, V.4    Lagneau, C.5    Lissac, M.6    Martelet, C.7
  • 74
    • 0016803288 scopus 로고
    • A study of the effect of particulate metals of orthopaedic interest on murine macrophages in vitro
    • Br
    • Rae T. A study of the effect of particulate metals of orthopaedic interest on murine macrophages in vitro. J Bone Joint Surg 1975, 5B:444-450. Br.
    • (1975) J Bone Joint Surg , vol.5 B , pp. 444-450
    • Rae, T.1
  • 75
    • 34447317276 scopus 로고    scopus 로고
    • The spinal cord dura matter reaction to Nitinol and titanium alloy particles: a 1 year study on rabbits
    • Rhalmi S., Charette S., Assad M., Coillard C., Rivard C. The spinal cord dura matter reaction to Nitinol and titanium alloy particles: a 1 year study on rabbits. Eur Spine 2007, 16:1063-1072.
    • (2007) Eur Spine , vol.16 , pp. 1063-1072
    • Rhalmi, S.1    Charette, S.2    Assad, M.3    Coillard, C.4    Rivard, C.5
  • 76
    • 51649179457 scopus 로고
    • Quantitative and morphologisheerfassung der geweberreaction auf metallimplante
    • Riede U., Ruedi T., Rohner Y., Perren S., Guggenheim R. Quantitative and morphologisheerfassung der geweberreaction auf metallimplante. Arch Orthop Unfall Chir 1974, 78:199-214.
    • (1974) Arch Orthop Unfall Chir , vol.78 , pp. 199-214
    • Riede, U.1    Ruedi, T.2    Rohner, Y.3    Perren, S.4    Guggenheim, R.5
  • 79
    • 0032777189 scopus 로고    scopus 로고
    • Continued expansion of Nitinol self-expandable stent angiographic analysis and 1-year clinical follow-up
    • Roguin A., Granadier E., Linn S., Markiewicz W., Beyer R. Continued expansion of Nitinol self-expandable stent angiographic analysis and 1-year clinical follow-up. Am Heart J 1999, 138(2):326-333.
    • (1999) Am Heart J , vol.138 , Issue.2 , pp. 326-333
    • Roguin, A.1    Granadier, E.2    Linn, S.3    Markiewicz, W.4    Beyer, R.5
  • 80
    • 0025192709 scopus 로고
    • The corrosion behavior of nickel titanium shape memory alloys
    • Rondelli G., Vicentini B., Cigada A. The corrosion behavior of nickel titanium shape memory alloys. Corr Sci 1990, 30:805-812.
    • (1990) Corr Sci , vol.30 , pp. 805-812
    • Rondelli, G.1    Vicentini, B.2    Cigada, A.3
  • 81
    • 0344631774 scopus 로고    scopus 로고
    • Bone healing and mineralization, implant corrosion and trace metals after nickel-titanium shape memory metal intramedullary fixation
    • Ryhänen J., Kallioinen M., Serlo S., Peramaki P., Junila J., Sandvik P., Niemelä E., Tuukkanen J. Bone healing and mineralization, implant corrosion and trace metals after nickel-titanium shape memory metal intramedullary fixation. J Biomed Mater Res 1999, 47:472-480.
    • (1999) J Biomed Mater Res , vol.47 , pp. 472-480
    • Ryhänen, J.1    Kallioinen, M.2    Serlo, S.3    Peramaki, P.4    Junila, J.5    Sandvik, P.6    Niemelä, E.7    Tuukkanen, J.8
  • 82
    • 0032487124 scopus 로고    scopus 로고
    • In vivo biocompatibility evaluation of nickel-titanium shape memory alloy. Muscle and peripheral tissue responses and encapsule membrane thickness
    • Ryhänen J., Kallioinen M., Tuukkanen J., Junila J., Niemelä E., Sandvik P., Serlo V. In vivo biocompatibility evaluation of nickel-titanium shape memory alloy. Muscle and peripheral tissue responses and encapsule membrane thickness. J Biomed Res 1998, 41:481-488.
    • (1998) J Biomed Res , vol.41 , pp. 481-488
    • Ryhänen, J.1    Kallioinen, M.2    Tuukkanen, J.3    Junila, J.4    Niemelä, E.5    Sandvik, P.6    Serlo, V.7
  • 84
    • 3242781591 scopus 로고    scopus 로고
    • Primary patency of femoropopliteal arteries treated with Nitinol versus stainless steel self-expendindg stents: propensity score-adjusted analysis
    • Sabeti S., Schillinger M., Amighi J., Sherif C., Mlekush W., Ahmadi R., Minar E. Primary patency of femoropopliteal arteries treated with Nitinol versus stainless steel self-expendindg stents: propensity score-adjusted analysis. Radiology 2004, 232:516-521.
    • (2004) Radiology , vol.232 , pp. 516-521
    • Sabeti, S.1    Schillinger, M.2    Amighi, J.3    Sherif, C.4    Mlekush, W.5    Ahmadi, R.6    Minar, E.7
  • 85
    • 34248638553 scopus 로고    scopus 로고
    • Mechanical properties of soft human tissues under dynamic loading
    • Saraf H., Ramesh K., Lennon A., Merkle A., Roberts J. Mechanical properties of soft human tissues under dynamic loading. J Biomech 2007, 40:1960-1967.
    • (2007) J Biomech , vol.40 , pp. 1960-1967
    • Saraf, H.1    Ramesh, K.2    Lennon, A.3    Merkle, A.4    Roberts, J.5
  • 86
    • 0024415538 scopus 로고
    • Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty; a study in the atherosclerotic rabbit
    • Sarembock I., Laveau P., Sigal S., Timms I., Sussman J., Haudenschild C., Ezekowitz M.D. Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty; a study in the atherosclerotic rabbit. Circulation 1989, 80:1029-1040.
    • (1989) Circulation , vol.80 , pp. 1029-1040
    • Sarembock, I.1    Laveau, P.2    Sigal, S.3    Timms, I.4    Sussman, J.5    Haudenschild, C.6    Ezekowitz, M.D.7
  • 88
    • 67349246430 scopus 로고    scopus 로고
    • Corrosion studies with AFM, Part 1: Characterization of potential inhomogeneities on passive surfaces by surface potential imaging
    • Schmutz P., Frankel G., Serry F. Corrosion studies with AFM, Part 1: Characterization of potential inhomogeneities on passive surfaces by surface potential imaging. Veeco Instruments Inc 2005, 5:AN87-91.
    • (2005) Veeco Instruments Inc , vol.5
    • Schmutz, P.1    Frankel, G.2    Serry, F.3
  • 90
    • 0026515530 scopus 로고
    • Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model
    • Schwartz R., Huber K., Murphy J., Edwards W., Camrud A., Vlietstra R., Holmes D. Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. J Am Coll Cardiol 1992, 19:267-274.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 267-274
    • Schwartz, R.1    Huber, K.2    Murphy, J.3    Edwards, W.4    Camrud, A.5    Vlietstra, R.6    Holmes, D.7
  • 91
    • 0030340747 scopus 로고    scopus 로고
    • On the nature of biocompatibility and medical applications of Ti- Ni shape memory alloys
    • Shabalovskaya S. On the nature of biocompatibility and medical applications of Ti- Ni shape memory alloys. Bio Med Mater Eng 1996, 6:267-290.
    • (1996) Bio Med Mater Eng , vol.6 , pp. 267-290
    • Shabalovskaya, S.1
  • 92
    • 0035570621 scopus 로고    scopus 로고
    • Physicochemical and biological aspects of Nitinol as a biomaterial
    • Shabalovskaya S. Physicochemical and biological aspects of Nitinol as a biomaterial. Int Mater Rev 2001, 4:233-250.
    • (2001) Int Mater Rev , vol.4 , pp. 233-250
    • Shabalovskaya, S.1
  • 93
    • 0036179018 scopus 로고    scopus 로고
    • Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
    • Shabalovskaya S. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material. Bio Med Mater Eng 2002, 12:69-109.
    • (2002) Bio Med Mater Eng , vol.12 , pp. 69-109
    • Shabalovskaya, S.1
  • 94
    • 0346244109 scopus 로고    scopus 로고
    • Surface conditions of Nitinol wires, tubing, and as-cast alloys: The effect of chemical etching, aging in boiling water, and heat treatment
    • Shabalovskaya S., Anderegg J., Laabs F., Thiel P., Rondelli G. Surface conditions of Nitinol wires, tubing, and as-cast alloys: The effect of chemical etching, aging in boiling water, and heat treatment. J Biomed Mater Res 2003, 65B:193-203.
    • (2003) J Biomed Mater Res , vol.65 B , pp. 193-203
    • Shabalovskaya, S.1    Anderegg, J.2    Laabs, F.3    Thiel, P.4    Rondelli, G.5
  • 97
    • 41549097188 scopus 로고    scopus 로고
    • Critical overview of Nitinol surfaces and their modifications for medical applications
    • Shabalovskaya S., Anderegg J., Van Humbeeck J. Critical overview of Nitinol surfaces and their modifications for medical applications. Acta Biomater 2008, 4(3):447-467.
    • (2008) Acta Biomater , vol.4 , Issue.3 , pp. 447-467
    • Shabalovskaya, S.1    Anderegg, J.2    Van Humbeeck, J.3
  • 99
    • 2442440803 scopus 로고    scopus 로고
    • Comparative corrosion performance of black oxide, sandblasted, and fine-drawn Nitinol wires in potentiodynamic and potentiostatic tests: Effects of chemical etching and electropolishing
    • Shabalovskaya S., Rondelli G., Anderegg J., Xiong J., Wu M. Comparative corrosion performance of black oxide, sandblasted, and fine-drawn Nitinol wires in potentiodynamic and potentiostatic tests: Effects of chemical etching and electropolishing. J Biomed Mater Res 2004, 69B:223-231.
    • (2004) J Biomed Mater Res , vol.69 B , pp. 223-231
    • Shabalovskaya, S.1    Rondelli, G.2    Anderegg, J.3    Xiong, J.4    Wu, M.5
  • 101
    • 0029739551 scopus 로고    scopus 로고
    • Subacute thrombosis and vascular injury resulting from slotted-tube Nitinol and stainless-steel stents in rabbit artery model
    • Sheth S., Litvack F., Visha D., Fishbein M., Forrester J., Eigler N. Subacute thrombosis and vascular injury resulting from slotted-tube Nitinol and stainless-steel stents in rabbit artery model. Circulation 1996, 94:1733-1740.
    • (1996) Circulation , vol.94 , pp. 1733-1740
    • Sheth, S.1    Litvack, F.2    Visha, D.3    Fishbein, M.4    Forrester, J.5    Eigler, N.6
  • 102
    • 4344574094 scopus 로고    scopus 로고
    • Studies of surface modified Ti-Ni alloys
    • Shevchenko N., Pham M., Maitz M. Studies of surface modified Ti-Ni alloys. Appl Surf Sci 2004, 235:126-131.
    • (2004) Appl Surf Sci , vol.235 , pp. 126-131
    • Shevchenko, N.1    Pham, M.2    Maitz, M.3
  • 103
    • 0034333616 scopus 로고    scopus 로고
    • The cytotoxicity of corrosion products of Nitinol stent wires on cultured smooth muscle cells
    • Shih C., Lin S., Chen Y., Su Y., Lai S., Wu G., Kwok C., Chung K. The cytotoxicity of corrosion products of Nitinol stent wires on cultured smooth muscle cells. J Biomed Mater Res 2000, 52:395-403.
    • (2000) J Biomed Mater Res , vol.52 , pp. 395-403
    • Shih, C.1    Lin, S.2    Chen, Y.3    Su, Y.4    Lai, S.5    Wu, G.6    Kwok, C.7    Chung, K.8
  • 104
    • 0034028566 scopus 로고    scopus 로고
    • Evaluation of in vivo biocompatibility of different devices for interventional closure of the patent ductus arteriosus in animal model
    • Sigler M., Handt S., Seghaye M.C., Van Bernuth G., Grabitz R. Evaluation of in vivo biocompatibility of different devices for interventional closure of the patent ductus arteriosus in animal model. Heart 2000, 83:570-573.
    • (2000) Heart , vol.83 , pp. 570-573
    • Sigler, M.1    Handt, S.2    Seghaye, M.C.3    Van Bernuth, G.4    Grabitz, R.5
  • 105
    • 34247343186 scopus 로고    scopus 로고
    • Biocompatibility of septal defect closure devices
    • Sigler M., Jux C. Biocompatibility of septal defect closure devices. Heart 2007, 93:444-449.
    • (2007) Heart , vol.93 , pp. 444-449
    • Sigler, M.1    Jux, C.2
  • 106
    • 21544469971 scopus 로고    scopus 로고
    • Biocompatibility screening in cardiovascular implants
    • Sigler M., Paul T., Grabitz R. Biocompatibility screening in cardiovascular implants. Z Kardiol 2005, 94:383-391.
    • (2005) Z Kardiol , vol.94 , pp. 383-391
    • Sigler, M.1    Paul, T.2    Grabitz, R.3
  • 107
    • 0029278135 scopus 로고
    • Cranial bone apposition and ingrowth in a porous Ti-Ni implant
    • Simske S., Sachdeva R. Cranial bone apposition and ingrowth in a porous Ti-Ni implant. J Biomed Mater Res 1995, 29:527-533.
    • (1995) J Biomed Mater Res , vol.29 , pp. 527-533
    • Simske, S.1    Sachdeva, R.2
  • 108
    • 0022555659 scopus 로고
    • Cumulative patency and actual palliation in patients with claudication after aortofemoral bypass. Prospective long-term follow-up of 100 patients
    • Sladen J., Gilmour J., Wong R. Cumulative patency and actual palliation in patients with claudication after aortofemoral bypass. Prospective long-term follow-up of 100 patients. Am J Surg 1986, 152:190-195.
    • (1986) Am J Surg , vol.152 , pp. 190-195
    • Sladen, J.1    Gilmour, J.2    Wong, R.3
  • 109
    • 33748943616 scopus 로고    scopus 로고
    • Effect of diamond-like carbon (DLC) on the properties of Ti-Ni alloys
    • Sui J., Cai W. Effect of diamond-like carbon (DLC) on the properties of Ti-Ni alloys. Diamond Relat Mater 2006, 15:1720-1726.
    • (2006) Diamond Relat Mater , vol.15 , pp. 1720-1726
    • Sui, J.1    Cai, W.2
  • 112
    • 0031033349 scopus 로고    scopus 로고
    • Histomorphometric analysis of the response of rat tibia to shape memory alloy (Nitinol)
    • Takeshita F., Takata H., Ayukawa Y., Suetsugu T. Histomorphometric analysis of the response of rat tibia to shape memory alloy (Nitinol). Biomaterials 1997, 18:21-25.
    • (1997) Biomaterials , vol.18 , pp. 21-25
    • Takeshita, F.1    Takata, H.2    Ayukawa, Y.3    Suetsugu, T.4
  • 113
    • 26844515262 scopus 로고    scopus 로고
    • Reduced thrombogenicity of Nitinol stents - in vitro evaluation of different surface modifications and coatings
    • Tepe G., Schmehl J., Wendel H., Schaffner S., Heller S., Gianotti M., Claussen C., Duda S. Reduced thrombogenicity of Nitinol stents - in vitro evaluation of different surface modifications and coatings. Biomaterials 2006, 27:643-650.
    • (2006) Biomaterials , vol.27 , pp. 643-650
    • Tepe, G.1    Schmehl, J.2    Wendel, H.3    Schaffner, S.4    Heller, S.5    Gianotti, M.6    Claussen, C.7    Duda, S.8
  • 114
    • 0036013823 scopus 로고    scopus 로고
    • Nitinol versus stainless-steel stents: Acute thrombogenicity study in an ex vivo porcine mode
    • Thierry B., Merhi Y., Bilodeau L., Trepanier C., Tabrizian M. Nitinol versus stainless-steel stents: Acute thrombogenicity study in an ex vivo porcine mode. Biomaterials 2002, 23:2997-3005.
    • (2002) Biomaterials , vol.23 , pp. 2997-3005
    • Thierry, B.1    Merhi, Y.2    Bilodeau, L.3    Trepanier, C.4    Tabrizian, M.5
  • 115
    • 0242331797 scopus 로고    scopus 로고
    • Biocompatibility and biostability of metallic endovascular implants: State of art and perspectives
    • Thierry B., Tabrizian M. Biocompatibility and biostability of metallic endovascular implants: State of art and perspectives. J Endovasc Ther 2003, 10:807-824.
    • (2003) J Endovasc Ther , vol.10 , pp. 807-824
    • Thierry, B.1    Tabrizian, M.2
  • 116
    • 84903918562 scopus 로고    scopus 로고
    • In-situ observation of surface oxide layers on medical grade Ni-Ti alloy during straining
    • in press
    • Undisz A., Schrempel F., Wesch W., Rettenmayr M. In-situ observation of surface oxide layers on medical grade Ni-Ti alloy during straining. J Biomed Mater Res 2008, in press.
    • (2008) J Biomed Mater Res
    • Undisz, A.1    Schrempel, F.2    Wesch, W.3    Rettenmayr, M.4
  • 117
    • 0033119620 scopus 로고    scopus 로고
    • Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopy
    • Uo M., Watari F., Yokoyama A., Matsuno H., Kawasaki T. Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopy. Biomaterials 1999, 20:747-755.
    • (1999) Biomaterials , vol.20 , pp. 747-755
    • Uo, M.1    Watari, F.2    Yokoyama, A.3    Matsuno, H.4    Kawasaki, T.5
  • 118
    • 0022645576 scopus 로고
    • Six-year prospective multicentral randomized comparison of autologus saphenous vein and expanded grafts in infrainguinal arterial reconstructions
    • Veith F., Gupta S., Ascer E., White-Flores S., Samson R., Scher L., et al. Six-year prospective multicentral randomized comparison of autologus saphenous vein and expanded grafts in infrainguinal arterial reconstructions. J Vasc Surg 1986, 3:104-114.
    • (1986) J Vasc Surg , vol.3 , pp. 104-114
    • Veith, F.1    Gupta, S.2    Ascer, E.3    White-Flores, S.4    Samson, R.5    Scher, L.6
  • 119
    • 0032127309 scopus 로고    scopus 로고
    • Histomorphometrical and mechanical evolution of titanium plasma spray-coated implants, placed in the cortical bone of goats
    • Versaigne S., Wolke J., Naert, Jansen J. Histomorphometrical and mechanical evolution of titanium plasma spray-coated implants, placed in the cortical bone of goats. J Biomed Mater Res 1998, 41:41-48.
    • (1998) J Biomed Mater Res , vol.41 , pp. 41-48
    • Versaigne, S.1    Wolke, J.2    Naert, J.J.3
  • 120
    • 0030560643 scopus 로고    scopus 로고
    • Ti, Cr, and Co ions modulate the release of bone-associated cytokines by human monocytes/mackrophages in vitro
    • Wang J., Mwickland B., Gustilo R., Tsukayama D. Ti, Cr, and Co ions modulate the release of bone-associated cytokines by human monocytes/mackrophages in vitro. Biomaterials 1996, 17:2233-2240.
    • (1996) Biomaterials , vol.17 , pp. 2233-2240
    • Wang, J.1    Mwickland, B.2    Gustilo, R.3    Tsukayama, D.4
  • 121
    • 1642346536 scopus 로고    scopus 로고
    • Sublethal concentrations of Au(III), Pd(II), and Ni (II) differentially alter inflammatory cytokine secretion from activated monocytes
    • Wataha J., Lewis J., Volkman K., Lockwood P., Messer R., Bouillaguet S. Sublethal concentrations of Au(III), Pd(II), and Ni (II) differentially alter inflammatory cytokine secretion from activated monocytes. J Biomed Mater Res 2004, 69B:11-17.
    • (2004) J Biomed Mater Res , vol.69 B , pp. 11-17
    • Wataha, J.1    Lewis, J.2    Volkman, K.3    Lockwood, P.4    Messer, R.5    Bouillaguet, S.6
  • 122
    • 0032943419 scopus 로고    scopus 로고
    • Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro
    • Wataha J., Lockwood P., Marek M., Ghazi M. Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro. J Biomed Mater Res 1999, 45:252-257.
    • (1999) J Biomed Mater Res , vol.45 , pp. 252-257
    • Wataha, J.1    Lockwood, P.2    Marek, M.3    Ghazi, M.4
  • 127
    • 26944441641 scopus 로고    scopus 로고
    • Improvement of corrosion resistance, mechanical properties and cyto-compatibility of Ti-Ni shape memory alloys using nitrogen, and oxygen plasma immersion ion implantation
    • Yeung K., Poon R., Liu X., Ho J., Chung C., Chu P., et al. Improvement of corrosion resistance, mechanical properties and cyto-compatibility of Ti-Ni shape memory alloys using nitrogen, and oxygen plasma immersion ion implantation. J Biomed Mater Res 2005, 75A:256-267.
    • (2005) J Biomed Mater Res , vol.75 A , pp. 256-267
    • Yeung, K.1    Poon, R.2    Liu, X.3    Ho, J.4    Chung, C.5    Chu, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.