-
1
-
-
0029039310
-
Transfemoral endovascular stented repair of an abdominal aortic aneurysm
-
PARODI JC, MARTIN ML, VEITH FJ. Transfemoral endovascular stented repair of an abdominal aortic aneurysm. Arch Surg 1995; 130: 549-552.
-
(1995)
Arch Surg
, vol.130
, pp. 549-552
-
-
Parodi, J.C.1
Martin, M.L.2
Veith, F.J.3
-
2
-
-
0030857450
-
Endovascular treatment of infrarenal abdominal aneurysms by the Stentor system: Preliminary results of 79 cases
-
Stentor Retrospective Study Group
-
MIALHE C, AMICABILE C, BECQUEMIN JP. Endovascular treatment of infrarenal abdominal aneurysms by the Stentor system: preliminary results of 79 cases. Stentor Retrospective Study Group. J Vasc Surg 1997; 26: 199-209.
-
(1997)
J Vasc Surg
, vol.26
, pp. 199-209
-
-
Mialhe, C.1
Amicabile, C.2
Becquemin, J.P.3
-
3
-
-
0031453479
-
Three-year experience with modular stent-graft devices for endovascular AAA treatment
-
STELTER W, UMSCHEID T, ZIEGLER P. Three-year experience with modular stent-graft devices for endovascular AAA treatment. J Endovasc Surg 1997; 4: 362-369.
-
(1997)
J Endovasc Surg
, vol.4
, pp. 362-369
-
-
Stelter, W.1
Umscheid, T.2
Ziegler, P.3
-
4
-
-
0031721235
-
Experience with the Stentor endograft at four Italian centers
-
COPPI G, PACCHIONI R, MORATTO R et al. Experience with the Stentor endograft at four Italian centers. J Endovasc Surg 1998; 5: 206-215.
-
(1998)
J Endovasc Surg
, vol.5
, pp. 206-215
-
-
Coppi, G.1
Pacchioni, R.2
Moratto, R.3
-
5
-
-
0019475829
-
Late fiber deterioration in dacron arterial grafts
-
BERGER K, SAUVAGE LG. Late Fiber Deterioration in Dacron Arterial Grafts. Ann Surg 1981; 193: 477.
-
(1981)
Ann Surg
, vol.193
, pp. 477
-
-
Berger, K.1
Sauvage, L.G.2
-
6
-
-
0033023672
-
The frame dislocation of body middle rings in endovascular stent tube grafts
-
RIEPE G, HEILBERGER P, UMSCHEID T et al. The Frame Dislocation of Body Middle Rings in Endovascular Stent Tube Grafts. Eur J Vasc Endovasc Surg 1999; 17: 28-34.
-
(1999)
Eur J Vasc Endovasc Surg
, vol.17
, pp. 28-34
-
-
Riepe, G.1
Heilberger, P.2
Umscheid, T.3
-
7
-
-
0034911604
-
Corroded nitinol wires in explanted aortic endografts: An important mechanism of failure?
-
HEINTZ C, RIEPE G, BIRKEN L et al. Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure? J Endovasc Ther 2001; 8: 248-253.
-
(2001)
J Endovasc Ther
, vol.8
, pp. 248-253
-
-
Heintz, C.1
Riepe, G.2
Birken, L.3
-
8
-
-
84888061863
-
Simulation and control of MIC by the miniplant technique
-
Heitz E, Flemming HC, Sand W (eds) Berlin: Springer
-
EUL U, V. REÉGE H, HEITZ E, SAND W. Simulation and control of MIC by the miniplant technique. In: Heitz E, Flemming HC, Sand W (eds) Microbially Influenced Corrosion of Materials. Berlin: Springer 1996; 187-203.
-
(1996)
Microbially Influenced Corrosion of Materials
, pp. 187-203
-
-
Eul, U.1
Reége, H.2
Heitz, E.3
Sand, W.4
-
9
-
-
79952186812
-
Statistical data analysis of microbially influenced deterioration of concrete
-
Dechema (ed.) Frankfurt
-
JOZSA PG, KUßMAUL M, BOCK E. Statistical data analysis of microbially influenced deterioration of concrete. In: Dechema (ed.) Biodeterioration and Biodegradation - DECHEMA monographs. Vol. 133, Frankfurt, 1996; 199-208.
-
(1996)
Biodeterioration and Biodegradation - DECHEMA Monographs
, vol.133
, pp. 199-208
-
-
Jozsa, P.G.1
Kußmaul, M.2
Bock, E.3
-
10
-
-
0345129973
-
Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents
-
TREPANIER C, LEUNG TK, TABRIZIAN M, YAHIA LH, BIENVENU JG, TANGUAY JF, PIRON DL, BILODEAU L. Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents. J Biomed Mater Res 1999; 48: 165-171.
-
(1999)
J Biomed Mater Res
, vol.48
, pp. 165-171
-
-
Trepanier, C.1
Leung, T.K.2
Tabrizian, M.3
Yahia, L.H.4
Bienvenu, J.G.5
Tanguay, J.F.6
Piron, D.L.7
Bilodeau, L.8
-
12
-
-
0032487124
-
In vivo biocompatibility evaluation if nickel-titanium shape memory metal alloy: Muscle and perineural tissue responses and encapsule membrane thickness
-
RYHÄNEN J, KALLIOINEN M, TUUKKANEN J et al. In vivo biocompatibility evaluation if nickel-titanium shape memory metal alloy: muscle and perineural tissue responses and encapsule membrane thickness. J Biomed Mater Res 1998; 41: 481-488.
-
(1998)
J Biomed Mater Res
, vol.41
, pp. 481-488
-
-
Ryhänen, J.1
Kallioinen, M.2
Tuukkanen, J.3
-
13
-
-
0033865287
-
First-generation aortic endografts: Analysis of explanted Stentor devices from the EUROSTAR Registry
-
GUIDOIN R, MAROIS Y, DOUVILLE Y et al. First-generation aortic endografts: analysis of explanted Stentor devices from the EUROSTAR Registry. J Endovasc Ther 2000; 7: 105-122.
-
(2000)
J Endovasc Ther
, vol.7
, pp. 105-122
-
-
Guidoin, R.1
Marois, Y.2
Douville, Y.3
-
14
-
-
0030837828
-
Long-term in vivo alterations of polyester vascular grafts in humans
-
RIEPE G, LOOS J, IMIG H et al. Long-term in vivo Alterations of Polyester Vascular Grafts in Humans. Eur J Vasc Endovasc Surg 1997; 13: 540-548.
-
(1997)
Eur J Vasc Endovasc Surg
, vol.13
, pp. 540-548
-
-
Riepe, G.1
Loos, J.2
Imig, H.3
-
15
-
-
0032984801
-
The limits of endovascular aortic aneurysm repair
-
ZARINS CK. The Limits of Endovascular Aortic Aneurysm Repair. J Vasc Surg 1999; 29: 1164-1166.
-
(1999)
J Vasc Surg
, vol.29
, pp. 1164-1166
-
-
Zarins, C.K.1
|