메뉴 건너뛰기




Volumn 26, Issue 8, 2010, Pages

The effect of interference screw diameter on fixation of soft-tissue grafts in anterior cruciate ligament reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION; ARTICLE; BIODEGRADABLE IMPLANT; BIOMECHANICS; BONE PATELLAR TENDON BONE GRAFT; BONE SCREW; CONTROLLED STUDY; GRAFT DYSFUNCTION; GRAFT FAILURE; GRAFT SLIPPAGE; INTERFERENCE SCREW; NONHUMAN; OUTCOME ASSESSMENT; SOFT TISSUE; TENSILE STRENGTH; TIBIA; TISSUE FIXATION; TISSUE GRAFT; VIDEORECORDING; WEIGHT, MASS AND SIZE;

EID: 77955477914     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2009.12.022     Document Type: Article
Times cited : (38)

References (36)
  • 1
    • 1942439016 scopus 로고    scopus 로고
    • Mechanical properties of soft tissue femoral fixation devices for anterior cruciate ligament reconstruction
    • C.S. Ahmad, T.R. Gardner, M. Groh, J. Arnouk, and W.N. Levine Mechanical properties of soft tissue femoral fixation devices for anterior cruciate ligament reconstruction Am J Sports Med 32 2004 635 640
    • (2004) Am J Sports Med , vol.32 , pp. 635-640
    • Ahmad, C.S.1    Gardner, T.R.2    Groh, M.3    Arnouk, J.4    Levine, W.N.5
  • 2
    • 0033802701 scopus 로고    scopus 로고
    • Interference screw fixation strength on quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque
    • J.C. Brand Jr, D. Peinkowski, E. Steenlage, D. Hamilton, D.L. Johnson, and D.N. Caborn Interference screw fixation strength on quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque Am J Sports Med 28 2000 705 710
    • (2000) Am J Sports Med , vol.28 , pp. 705-710
    • Brand Jr., J.C.1    Peinkowski, D.2    Steenlage, E.3    Hamilton, D.4    Johnson, D.L.5    Caborn, D.N.6
  • 3
    • 0032847047 scopus 로고    scopus 로고
    • Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction
    • M. Giurea, P. Zorilla, A.A. Amis, and P. Aichroth Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction Am J Sports Med 27 1999 621 625
    • (1999) Am J Sports Med , vol.27 , pp. 621-625
    • Giurea, M.1    Zorilla, P.2    Amis, A.A.3    Aichroth, P.4
  • 4
    • 18944363640 scopus 로고    scopus 로고
    • Fixation of the graft in reconstruction of the ACL
    • A. Harvey, N. T, and A.A. Amis Fixation of the graft in reconstruction of the ACL J Bone Joint Surg Br 87 2005 593 603
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 593-603
    • Harvey, A.1    N, T.2    Amis, A.A.3
  • 5
    • 12244302176 scopus 로고    scopus 로고
    • The effect of screw length and position on fixation of four-stranded hamstring grafts for anterior cruciate ligament reconstruction
    • A.R. Harvey, N.P. Thomas, and A.A. Amis The effect of screw length and position on fixation of four-stranded hamstring grafts for anterior cruciate ligament reconstruction Knee 10 2003 97 102
    • (2003) Knee , vol.10 , pp. 97-102
    • Harvey, A.R.1    Thomas, N.P.2    Amis, A.A.3
  • 6
    • 35648998931 scopus 로고    scopus 로고
    • Augmentation of tibial fixation of soft-tissue grafts in anterior cruciate ligament reconstruction
    • A. John, R. Stanley, K. Nilsson, and J. Field Augmentation of tibial fixation of soft-tissue grafts in anterior cruciate ligament reconstruction Arthroscopy 23 2007 1193 1197
    • (2007) Arthroscopy , vol.23 , pp. 1193-1197
    • John, A.1    Stanley, R.2    Nilsson, K.3    Field, J.4
  • 7
    • 0037347246 scopus 로고    scopus 로고
    • The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction: Part I: Femoral site
    • P. Kousa, T.L. Jarvinen, M. Vihavainen, and M. Jarvinen The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction Part I: Femoral site Am J Sports Med 31 2003 174 181
    • (2003) Am J Sports Med , vol.31 , pp. 174-181
    • Kousa, P.1    Jarvinen, T.L.2    Vihavainen, M.3    Jarvinen, M.4
  • 8
    • 0037346994 scopus 로고    scopus 로고
    • The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction: Part II: Tibial site
    • P. Kousa, T.L. Jarvinen, M. Vihavainen, and M. Jarvinen The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction Part II: Tibial site Am J Sports Med 31 2003 182 188
    • (2003) Am J Sports Med , vol.31 , pp. 182-188
    • Kousa, P.1    Jarvinen, T.L.2    Vihavainen, M.3    Jarvinen, M.4
  • 9
    • 1242343973 scopus 로고    scopus 로고
    • Hamstring anterior cruciate ligament reconstruction: A comparison of bioabsorbable interference screw and endobutton-post fixation
    • C.B. Ma, K. Francis, J. Towers, J. Irrgang, F.H. Fu, and C.H. Harner Hamstring anterior cruciate ligament reconstruction: A comparison of bioabsorbable interference screw and endobutton-post fixation Arthroscopy 20 2004 122 128
    • (2004) Arthroscopy , vol.20 , pp. 122-128
    • Ma, C.B.1    Francis, K.2    Towers, J.3    Irrgang, J.4    Fu, F.H.5    Harner, C.H.6
  • 10
    • 0032950678 scopus 로고    scopus 로고
    • Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts
    • H.E. Magen, S.M. Howell, and M.L. Hull Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts Am J Sports Med 27 1999 35 43
    • (1999) Am J Sports Med , vol.27 , pp. 35-43
    • Magen, H.E.1    Howell, S.M.2    Hull, M.L.3
  • 11
    • 45849144741 scopus 로고    scopus 로고
    • Bioabsorbable versus titanium interference screws with hamstring autograft in anterior cruciate ligament reconstruction: A prospective randomized trial with 2-year follow-up
    • P. Myers, M. Logan, A. Stokes, K. Boyd, and M. Watts Bioabsorbable versus titanium interference screws with hamstring autograft in anterior cruciate ligament reconstruction: A prospective randomized trial with 2-year follow-up Arthroscopy 24 2008 817 823
    • (2008) Arthroscopy , vol.24 , pp. 817-823
    • Myers, P.1    Logan, M.2    Stokes, A.3    Boyd, K.4    Watts, M.5
  • 12
    • 33750440784 scopus 로고    scopus 로고
    • Hybrid femoral fixation of soft-tissue grafts in anterior cruciate ligament reconstruction using the Endobutton CL and bioabsorbable interference screws: A biomechanical study
    • Y.H. Oh, S. Namkoong, and E.J. Strauss, et al. Hybrid femoral fixation of soft-tissue grafts in anterior cruciate ligament reconstruction using the Endobutton CL and bioabsorbable interference screws: A biomechanical study Arthroscopy 22 2006 1218 1224
    • (2006) Arthroscopy , vol.22 , pp. 1218-1224
    • Oh, Y.H.1    Namkoong, S.2    Strauss, E.J.3
  • 13
    • 0032702339 scopus 로고    scopus 로고
    • Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws: Influence of screw length
    • D.M. Stadelmaier, W.R. Lowe, O.A. Ilahi, P.C. Noble, and H.W. Kohl III Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws Influence of screw length Am J Sports Med 27 1999 778 783
    • (1999) Am J Sports Med , vol.27 , pp. 778-783
    • Stadelmaier, D.M.1    Lowe, W.R.2    Ilahi, O.A.3    Noble, P.C.4    Kohl III, H.W.5
  • 14
  • 15
    • 0031931882 scopus 로고    scopus 로고
    • Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone
    • A. Weiler, R.F. Hoffmann, A.C. Stähelin, H.J. Bail, C.J. Siepe, and N.P. Südkamp Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone Arthroscopy 14 1998 29 37
    • (1998) Arthroscopy , vol.14 , pp. 29-37
    • Weiler, A.1    Hoffmann, R.F.2    Stähelin, A.C.3    Bail, H.J.4    Siepe, C.J.5    Südkamp, N.P.6
  • 16
    • 14844335664 scopus 로고    scopus 로고
    • Primary stability of hamstring graft fixation with biodegradable suspension verses interference screws
    • A. Weimann, M. Rodieck, T. Zantop, J. Hassenpflug, and W. Petersen Primary stability of hamstring graft fixation with biodegradable suspension verses interference screws Arthroscopy 21 2005 266 274
    • (2005) Arthroscopy , vol.21 , pp. 266-274
    • Weimann, A.1    Rodieck, M.2    Zantop, T.3    Hassenpflug, J.4    Petersen, W.5
  • 17
    • 33750428192 scopus 로고    scopus 로고
    • Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: In vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws
    • T. Zantop, A. Weimann, R. Schmidtko, M. Herbort, M.J. Raschke, and W. Petersen Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: In vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws Arthroscopy 22 2006 1204 1210
    • (2006) Arthroscopy , vol.22 , pp. 1204-1210
    • Zantop, T.1    Weimann, A.2    Schmidtko, R.3    Herbort, M.4    Raschke, M.J.5    Petersen, W.6
  • 18
    • 0033677953 scopus 로고    scopus 로고
    • Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction
    • K.P. Black, M.M. Saunders, K.C. Stube, M.J. Moulton, and C.R. Jacobs Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction Am J Sports Med 28 2000 846 849
    • (2000) Am J Sports Med , vol.28 , pp. 846-849
    • Black, K.P.1    Saunders, M.M.2    Stube, K.C.3    Moulton, M.J.4    Jacobs, C.R.5
  • 19
    • 0027508563 scopus 로고
    • The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
    • C.H. Brown Jr, A.T. Hecker, J.A. Hipp, E.R. Myers, and W.C. Hayes The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts Am J Sports Med 21 1993 880 886
    • (1993) Am J Sports Med , vol.21 , pp. 880-886
    • Brown Jr., C.H.1    Hecker, A.T.2    Hipp, J.A.3    Myers, E.R.4    Hayes, W.C.5
  • 20
    • 0028333661 scopus 로고
    • Patellar tendon versus doubled semitendinosus and gracilis tendons for anterior cruciate ligament reconstruction
    • discussion 217-218
    • P. Aglietti, R. Buzzi, G. Zaccherotti, and P. De Biase Patellar tendon versus doubled semitendinosus and gracilis tendons for anterior cruciate ligament reconstruction Am J Sports Med 22 1994 211 217 discussion 217-218
    • (1994) Am J Sports Med , vol.22 , pp. 211-217
    • Aglietti, P.1    Buzzi, R.2    Zaccherotti, G.3    De Biase, P.4
  • 21
    • 22144479334 scopus 로고    scopus 로고
    • Reconstruction of the anterior cruciate ligament: Meta-analysis of patellar tendon versus hamstring tendon autograft
    • J.P. Goldblatt, S.E. Fitzsimmons, E. Balk, and J.C. Richmond Reconstruction of the anterior cruciate ligament: Meta-analysis of patellar tendon versus hamstring tendon autograft Arthroscopy 21 2005 791 803
    • (2005) Arthroscopy , vol.21 , pp. 791-803
    • Goldblatt, J.P.1    Fitzsimmons, S.E.2    Balk, E.3    Richmond, J.C.4
  • 22
    • 7544243356 scopus 로고    scopus 로고
    • Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading
    • C.H. Brown Jr, D.R. Wilson, A.T. Hecker, and M. Ferragamo Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading Arthroscopy 20 2004 922 935
    • (2004) Arthroscopy , vol.20 , pp. 922-935
    • Brown Jr., C.H.1    Wilson, D.R.2    Hecker, A.T.3    Ferragamo, M.4
  • 23
    • 1342347903 scopus 로고    scopus 로고
    • Tendon graft fixation in ACL reconstruction: In vitro evaluation of bioabsorbable tenodesis screw
    • S.A. Klein, J. Nyland, Y. Kocabey, T. Wozniak, A. Nawab, and D.N. Caborn Tendon graft fixation in ACL reconstruction: In vitro evaluation of bioabsorbable tenodesis screw Acta Orthop Scand 75 2004 84 88
    • (2004) Acta Orthop Scand , vol.75 , pp. 84-88
    • Klein, S.A.1    Nyland, J.2    Kocabey, Y.3    Wozniak, T.4    Nawab, A.5    Caborn, D.N.6
  • 24
    • 0036524466 scopus 로고    scopus 로고
    • Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading
    • S.U. Scheffler, N.P. Sudkamp, A. Gockenjan, R.F. Hoffman, and A. Weiler Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading Arthroscopy 18 2002 304 315
    • (2002) Arthroscopy , vol.18 , pp. 304-315
    • Scheffler, S.U.1    Sudkamp, N.P.2    Gockenjan, A.3    Hoffman, R.F.4    Weiler, A.5
  • 25
    • 33750525514 scopus 로고    scopus 로고
    • Biomechanical testing of hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction
    • J.C. Yoo, J.H. Ahn, and J.H. Kim, et al. Biomechanical testing of hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction Knee 13 2006 455 459
    • (2006) Knee , vol.13 , pp. 455-459
    • Yoo, J.C.1    Ahn, J.H.2    Kim, J.H.3
  • 26
    • 0029916205 scopus 로고    scopus 로고
    • Comparison of failure strength between metallic and absorbable interference screws: Influence of insertion torque, tunnel-bone block gap, bone mineral density, and interference
    • F. Pena, T. Grontvedt, G.A. Brown, A.K. Aune, and L. Engebretsen Comparison of failure strength between metallic and absorbable interference screws Influence of insertion torque, tunnel-bone block gap, bone mineral density, and interference Am J Sports Med 24 1996 329 334
    • (1996) Am J Sports Med , vol.24 , pp. 329-334
    • Pena, F.1    Grontvedt, T.2    Brown, G.A.3    Aune, A.K.4    Engebretsen, L.5
  • 27
    • 0026459258 scopus 로고
    • The biomechanical effects of geometric configuration of bone-tendon-bone autografts in ACL reconstruction
    • J.D. Shapiro, B.T. Cohn, D.W. Jackson, P.D. Postak, R.D. Parker, and A.S. Greenwald The biomechanical effects of geometric configuration of bone-tendon-bone autografts in ACL reconstruction Arthroscopy 8 1992 453 458
    • (1992) Arthroscopy , vol.8 , pp. 453-458
    • Shapiro, J.D.1    Cohn, B.T.2    Jackson, D.W.3    Postak, P.D.4    Parker, R.D.5    Greenwald, A.S.6
  • 28
    • 0028017502 scopus 로고
    • Optimal graft fixation - The effect of gap size and screw size on bone plug fixation in ACL reconstruction
    • J.C. Butler, T.P. Branch, and W.C. Hutton Optimal graft fixation - The effect of gap size and screw size on bone plug fixation in ACL reconstruction Arthroscopy 10 1994 524 529
    • (1994) Arthroscopy , vol.10 , pp. 524-529
    • Butler, J.C.1    Branch, T.P.2    Hutton, W.C.3
  • 29
    • 0028821736 scopus 로고
    • Comparison of pull-out strength for seven and nine millimeter diameter interference screw size as used in ACL reconstruction
    • J.D. Shapiro, D.W. Jackson, H.M. Aberman, T.Q. Lee, and T.M. Simon Comparison of pull-out strength for seven and nine millimeter diameter interference screw size as used in ACL reconstruction Arthroscopy 11 1995 596 599
    • (1995) Arthroscopy , vol.11 , pp. 596-599
    • Shapiro, J.D.1    Jackson, D.W.2    Aberman, H.M.3    Lee, T.Q.4    Simon, T.M.5
  • 30
    • 0028244250 scopus 로고
    • Primary stability of interference screw fixation: Influence of screw diameter and insertion torque
    • D. Kohn, and C. Rose Primary stability of interference screw fixation Influence of screw diameter and insertion torque Am J Sports Med 22 1994 334 338
    • (1994) Am J Sports Med , vol.22 , pp. 334-338
    • Kohn, D.1    Rose, C.2
  • 31
    • 0021337787 scopus 로고
    • Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstruction
    • F.R. Noyes, D.L. Butler, E.S. Grood, R.F. Zernicke, and M.S. Hefzy Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstruction J Bone Joint Surg Am 66 1984 344 352
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 344-352
    • Noyes, F.R.1    Butler, D.L.2    Grood, E.S.3    Zernicke, R.F.4    Hefzy, M.S.5
  • 32
    • 1942478279 scopus 로고    scopus 로고
    • Pattern of anterior cruciate ligament force in normal walking
    • K.B. Shelburne, M.G. Pandy, F.C. Anderson, and M.R. Torry Pattern of anterior cruciate ligament force in normal walking J Biomech 37 2004 797 805
    • (2004) J Biomech , vol.37 , pp. 797-805
    • Shelburne, K.B.1    Pandy, M.G.2    Anderson, F.C.3    Torry, M.R.4
  • 33
    • 2442630193 scopus 로고    scopus 로고
    • How cyclic loading affects the migration of radio-opaque markers attached to tendon grafts using a new method: A study using roentgen stereophotogrammetric analysis (RSA)
    • P.J. Roos, M.L. Hull, and S.M. Howell How cyclic loading affects the migration of radio-opaque markers attached to tendon grafts using a new method: A study using roentgen stereophotogrammetric analysis (RSA) J Biomech Eng 126 2004 62 69
    • (2004) J Biomech Eng , vol.126 , pp. 62-69
    • Roos, P.J.1    Hull, M.L.2    Howell, S.M.3
  • 34
    • 0030632642 scopus 로고    scopus 로고
    • Pullout strength of tibial graft fixation in anterior cruciate ligament replacement with a patellar tendon graft: Interference screw versus staple fixation in human knees
    • T.G. Gerich, A. Cassim, C. Lattermann, and H.P. Lobenhoffer Pullout strength of tibial graft fixation in anterior cruciate ligament replacement with a patellar tendon graft: Interference screw versus staple fixation in human knees Knee Surg Sports Traumatol Arthrosc 5 1997 84 88
    • (1997) Knee Surg Sports Traumatol Arthrosc , vol.5 , pp. 84-88
    • Gerich, T.G.1    Cassim, A.2    Lattermann, C.3    Lobenhoffer, H.P.4
  • 35
    • 0029704294 scopus 로고    scopus 로고
    • Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: Influence of insertion torque, tunnel-bone block gap, and interference
    • C.H. Brown Jr, F. Pena, T. Grontvedt, D. Labadie, and L. Engebretsen Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: Influence of insertion torque, tunnel-bone block gap, and interference Knee Surg Sports Traumatol Arthrosc 3 1996 238 244
    • (1996) Knee Surg Sports Traumatol Arthrosc , vol.3 , pp. 238-244
    • Brown Jr., C.H.1    Pena, F.2    Grontvedt, T.3    Labadie, D.4    Engebretsen, L.5
  • 36
    • 33745685501 scopus 로고    scopus 로고
    • The effect of interference screw diameter on soft tissue graft fixation
    • S. Namkoong, C.S. Heywood, and J.T. Bravman, et al. The effect of interference screw diameter on soft tissue graft fixation Bull Hosp Jt Dis 63 2006 153 155
    • (2006) Bull Hosp Jt Dis , vol.63 , pp. 153-155
    • Namkoong, S.1    Heywood, C.S.2    Bravman, J.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.