메뉴 건너뛰기




Volumn 22, Issue 11, 2006, Pages 1204-1210

Graft Laceration and Pullout Strength of Soft-Tissue Anterior Cruciate Ligament Reconstruction: In Vitro Study Comparing Titanium, Poly-D,L-Lactide, and Poly-D,L-Lactide-Tricalcium Phosphate Screws

Author keywords

Biodegradable implants; Graft damage; Osteoconductive; Properties; Revision

Indexed keywords

CALCIUM PHOSPHATE; POLYLACTIDE; TITANIUM;

EID: 33750428192     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2006.06.015     Document Type: Article
Times cited : (107)

References (34)
  • 1
    • 0033971028 scopus 로고    scopus 로고
    • Current trends in anterior cruciate ligament reconstruction. Part II: Operative procedures and clinical correlations
    • Fu F.H., Bennet C.H., Ma B., Menetrey J., and Lattermann C. Current trends in anterior cruciate ligament reconstruction. Part II: Operative procedures and clinical correlations. Am J Sports Med 28 (2000) 124-130
    • (2000) Am J Sports Med , vol.28 , pp. 124-130
    • Fu, F.H.1    Bennet, C.H.2    Ma, B.3    Menetrey, J.4    Lattermann, C.5
  • 2
    • 0030667717 scopus 로고    scopus 로고
    • The science of reconstruction of the anterior cruciate ligament
    • Frank C.B., and Jackson D.W. The science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg Am 79 (1996) 1556-1576
    • (1996) J Bone Joint Surg Am , vol.79 , pp. 1556-1576
    • Frank, C.B.1    Jackson, D.W.2
  • 5
    • 1942464292 scopus 로고
    • Analysis of a semitendinosus autograft in a rabbit model
    • Blickenstaff K., Grana W., and Egle D. Analysis of a semitendinosus autograft in a rabbit model. Am J Sports Med 25 (1994) 344-351
    • (1994) Am J Sports Med , vol.25 , pp. 344-351
    • Blickenstaff, K.1    Grana, W.2    Egle, D.3
  • 6
    • 0029873427 scopus 로고    scopus 로고
    • Failure of anterior cruciate ligament reconstruction: The biological basis
    • Corsetti J.R., and Jackson D.W. Failure of anterior cruciate ligament reconstruction: The biological basis. Clin Orthop Relat Res (1996) 42-49
    • (1996) Clin Orthop Relat Res , pp. 42-49
    • Corsetti, J.R.1    Jackson, D.W.2
  • 8
    • 0028290880 scopus 로고
    • An analysis of autograft fixation after anterior cruciate ligament reconstruction in a rabbit model
    • Grana W.A., Egle D.M., Mahnken R., and Goodhart C.W. An analysis of autograft fixation after anterior cruciate ligament reconstruction in a rabbit model. Am J Sports Med 22 (1994) 344-351
    • (1994) Am J Sports Med , vol.22 , pp. 344-351
    • Grana, W.A.1    Egle, D.M.2    Mahnken, R.3    Goodhart, C.W.4
  • 9
  • 10
    • 0030791030 scopus 로고    scopus 로고
    • Anterior cruciate ligament graft fixation: Initial comparison of patellar tendon and semitendinosus autografts
    • Rowden N.J., Sher D., Rogers G.J., and Schindhelm K. Anterior cruciate ligament graft fixation: Initial comparison of patellar tendon and semitendinosus autografts. Am J Sports Med 25 (1997) 472-478
    • (1997) Am J Sports Med , vol.25 , pp. 472-478
    • Rowden, N.J.1    Sher, D.2    Rogers, G.J.3    Schindhelm, K.4
  • 11
    • 0034921039 scopus 로고    scopus 로고
    • Initial fixation strength of a biodegradable and titanium screws in anterior ligament reconstruction
    • Kousa P., Jarvinen T.L., Pohjonen T., and Jarvinen M. Initial fixation strength of a biodegradable and titanium screws in anterior ligament reconstruction. Am J Sports Med 29 (2001) 420-425
    • (2001) Am J Sports Med , vol.29 , pp. 420-425
    • Kousa, P.1    Jarvinen, T.L.2    Pohjonen, T.3    Jarvinen, M.4
  • 12
    • 0028929839 scopus 로고
    • Biomechanics of two types of bone-tendon-bone graft for ACL reconstruction
    • Liu S.H., Kabo J.M., and Osti L. Biomechanics of two types of bone-tendon-bone graft for ACL reconstruction. J Bone Joint Surg Br 77 (1995) 232-235
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 232-235
    • Liu, S.H.1    Kabo, J.M.2    Osti, L.3
  • 13
    • 0031885152 scopus 로고    scopus 로고
    • Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws
    • Weiler A., Windhagen H., Raschke M., Laumeyer A., and Hoffmann R.F. Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26 (1998) 548-549
    • (1998) Am J Sports Med , vol.26 , pp. 548-549
    • Weiler, A.1    Windhagen, H.2    Raschke, M.3    Laumeyer, A.4    Hoffmann, R.F.5
  • 14
    • 17144455842 scopus 로고    scopus 로고
    • Mechanical properties of suture materials for anchoring cruciate ligament transplants
    • (in German)
    • Becker R., Schroeder M., Roepke M., Ropke M., and Nebelung W. Mechanical properties of suture materials for anchoring cruciate ligament transplants. Unfallchirurg 103 (2000) 375-379 (in German)
    • (2000) Unfallchirurg , vol.103 , pp. 375-379
    • Becker, R.1    Schroeder, M.2    Roepke, M.3    Ropke, M.4    Nebelung, W.5
  • 15
    • 0030912837 scopus 로고    scopus 로고
    • The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system
    • Ishibashi Y., Rudy T.W., Livesay G.A., Stone J.D., Fu F.H., and Woo S.L. The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system. Arthroscopy 13 (1997) 177-182
    • (1997) Arthroscopy , vol.13 , pp. 177-182
    • Ishibashi, Y.1    Rudy, T.W.2    Livesay, G.A.3    Stone, J.D.4    Fu, F.H.5    Woo, S.L.6
  • 16
    • 0032702339 scopus 로고    scopus 로고
    • Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws. Influence of screw length
    • Stadelmaier D.M., Lowe W.R., Ilahi O.A., Noble P.C., and Kohl H.W. Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws. Influence of screw length. Am J Sports Med 27 (1999) 778-783
    • (1999) Am J Sports Med , vol.27 , pp. 778-783
    • Stadelmaier, D.M.1    Lowe, W.R.2    Ilahi, O.A.3    Noble, P.C.4    Kohl, H.W.5
  • 17
    • 7744222175 scopus 로고    scopus 로고
    • Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament
    • 465-461
    • Hoeher J., Scheffler S., Withrow J., et al. Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament. J Orthop Res 15 (2000) 465-461
    • (2000) J Orthop Res , vol.15
    • Hoeher, J.1    Scheffler, S.2    Withrow, J.3
  • 18
    • 0031741691 scopus 로고    scopus 로고
    • Bone tunnel enlargement after anterior cruciate ligament reconstruction with semitendinosus tendon using Endobutton fixation on the femoral side
    • Nebelung W., Becker R., Merkel M., and Ropke M. Bone tunnel enlargement after anterior cruciate ligament reconstruction with semitendinosus tendon using Endobutton fixation on the femoral side. Arthroscopy 14 (1998) 810-815
    • (1998) Arthroscopy , vol.14 , pp. 810-815
    • Nebelung, W.1    Becker, R.2    Merkel, M.3    Ropke, M.4
  • 19
    • 0032847047 scopus 로고    scopus 로고
    • Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction
    • Giurea M., Zorilla P., Amis A.A., et al. Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med 27 (1999) 621-625
    • (1999) Am J Sports Med , vol.27 , pp. 621-625
    • Giurea, M.1    Zorilla, P.2    Amis, A.A.3
  • 20
    • 0036166394 scopus 로고    scopus 로고
    • Properties of osteoconductive biomaterials: Calcium phosphates
    • LeGeros R.Z. Properties of osteoconductive biomaterials: Calcium phosphates. Clin Orthop Relat Res (2002) 81-98
    • (2002) Clin Orthop Relat Res , pp. 81-98
    • LeGeros, R.Z.1
  • 21
    • 0022872181 scopus 로고
    • Bioceramic implants in surgical periodontal defects. A comparison study
    • Barney V.C., Levin M.P., and Adams D.F. Bioceramic implants in surgical periodontal defects. A comparison study. J Periodontol 57 (1986) 764-770
    • (1986) J Periodontol , vol.57 , pp. 764-770
    • Barney, V.C.1    Levin, M.P.2    Adams, D.F.3
  • 22
    • 0019447856 scopus 로고
    • Calcium phosphate ceramics as hard tissue prosthetics
    • Jarcho M. Calcium phosphate ceramics as hard tissue prosthetics. Clin Orthop Relat Res (1981) 259-278
    • (1981) Clin Orthop Relat Res , pp. 259-278
    • Jarcho, M.1
  • 23
    • 0015324273 scopus 로고
    • Three biodegradable calcium phosphate slurry implants in bone
    • Getter L. Three biodegradable calcium phosphate slurry implants in bone. Oral Surg 30 (1972) 263-268
    • (1972) Oral Surg , vol.30 , pp. 263-268
    • Getter, L.1
  • 24
    • 0002618771 scopus 로고
    • In vitro testing protocols for the cruciate ligaments and ligament reconstructions
    • Beynnon B.D., and Amis A.A. In vitro testing protocols for the cruciate ligaments and ligament reconstructions. Knee Surg Sports Traumatol Arthrosc 6 (1992) 70-76
    • (1992) Knee Surg Sports Traumatol Arthrosc , vol.6 , pp. 70-76
    • Beynnon, B.D.1    Amis, A.A.2
  • 25
    • 0015076420 scopus 로고
    • Tissue reaction to the biodegradable material, PLA
    • Cutright D.E., and Hunsuck E.E. Tissue reaction to the biodegradable material, PLA. J Oral Surg 29 (1971) 393-397
    • (1971) J Oral Surg , vol.29 , pp. 393-397
    • Cutright, D.E.1    Hunsuck, E.E.2
  • 27
    • 0035121512 scopus 로고    scopus 로고
    • Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation
    • Nagarkatti D.G., McKeon B.P., Donahue B.S., and Fulkerson J.P. Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29 (2001) 67-71
    • (2001) Am J Sports Med , vol.29 , pp. 67-71
    • Nagarkatti, D.G.1    McKeon, B.P.2    Donahue, B.S.3    Fulkerson, J.P.4
  • 28
    • 0021337787 scopus 로고
    • Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions
    • Noyes F.R., Butler D.L., Grood E.S., et al. Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg AM 66 (1984) 344-350
    • (1984) J Bone Joint Surg AM , vol.66 , pp. 344-350
    • Noyes, F.R.1    Butler, D.L.2    Grood, E.S.3
  • 29
    • 0014619661 scopus 로고
    • Function of the knee joint various activities
    • Morrison J.B. Function of the knee joint various activities. Biomed Eng 4 (1969) 573-580
    • (1969) Biomed Eng , vol.4 , pp. 573-580
    • Morrison, J.B.1
  • 30
    • 0014698584 scopus 로고
    • Function of the knee joint in normal walking
    • Morrison J.B. Function of the knee joint in normal walking. J Biomech 3 (1970) 51-61
    • (1970) J Biomech , vol.3 , pp. 51-61
    • Morrison, J.B.1
  • 31
    • 0033009325 scopus 로고    scopus 로고
    • Resulting tensile forces in the human-patellar tendon-tendon bone graft: Direct force measurement in vitro
    • Rupp S., Hopf T., and Hess T. Resulting tensile forces in the human-patellar tendon-tendon bone graft: Direct force measurement in vitro. Arthroscopy 15 (1999) 179-184
    • (1999) Arthroscopy , vol.15 , pp. 179-184
    • Rupp, S.1    Hopf, T.2    Hess, T.3
  • 32
    • 0031961015 scopus 로고    scopus 로고
    • Initial fixation strength of polylactic acid interference screws in anterior cruciate ligament reconstruction
    • Abate J.A., Fadale P.D., Hustyn M.J., and Walsh W.R. Initial fixation strength of polylactic acid interference screws in anterior cruciate ligament reconstruction. Arthroscopy 14 (1998) 278-284
    • (1998) Arthroscopy , vol.14 , pp. 278-284
    • Abate, J.A.1    Fadale, P.D.2    Hustyn, M.J.3    Walsh, W.R.4
  • 33
    • 0029916205 scopus 로고    scopus 로고
    • Comparison of failure strength between metallic and absorbable interference screws: Influence of insertion torque, tunnel-bone bloc gap, bone mineral density, and interference
    • Pena F., Grontvedt T., Brown G.A., Aune A.K., and Engebretsen L. Comparison of failure strength between metallic and absorbable interference screws: Influence of insertion torque, tunnel-bone bloc gap, bone mineral density, and interference. Am J Sports Med 24 (1996) 329-334
    • (1996) Am J Sports Med , vol.24 , pp. 329-334
    • Pena, F.1    Grontvedt, T.2    Brown, G.A.3    Aune, A.K.4    Engebretsen, L.5
  • 34
    • 0036524466 scopus 로고    scopus 로고
    • Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading
    • Scheffler S.U., Südkamp N.P., Göckenjan A., Hoffmann R.F., and Weiler A. Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading. Arthroscopy 18 (2002) 304-315
    • (2002) Arthroscopy , vol.18 , pp. 304-315
    • Scheffler, S.U.1    Südkamp, N.P.2    Göckenjan, A.3    Hoffmann, R.F.4    Weiler, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.