메뉴 건너뛰기




Volumn 27, Issue 5, 1999, Pages 621-625

Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ANTERIOR CRUCIATE LIGAMENT; ARTICLE; BONE SCREW; CATTLE; FEMUR; FRACTURE HEALING; HAMSTRING; KNEE ARTHROPLASTY; LIGAMENT SURGERY; NONHUMAN; PRIORITY JOURNAL; SURGICAL TECHNIQUE; TENDON GRAFT; TIBIA;

EID: 0032847047     PISSN: 03635465     EISSN: None     Source Type: Journal    
DOI: 10.1177/03635465990270051301     Document Type: Article
Times cited : (158)

References (20)
  • 1
    • 0027401211 scopus 로고
    • Patellofemoral problems after intra-articular anterior cruciate ligament reconstruction
    • Aglietti P, Buzzi R, D'Andria S, et al: Patellofemoral problems after intra-articular anterior cruciate ligament reconstruction. Clin Orthop 288: 195-204, 1993
    • (1993) Clin Orthop , vol.288 , pp. 195-204
    • Aglietti, P.1    Buzzi, R.2    D'Andria, S.3
  • 2
    • 0028333661 scopus 로고
    • Patellar tendon versus doubled semitendinosus and gracilis tendons for anterior cruciate ligament reconstruction
    • Aglietti P, Buzzi R, Zaccherotti G, et al: Patellar tendon versus doubled semitendinosus and gracilis tendons for anterior cruciate ligament reconstruction. Am J Sports Med 22: 211-218, 1994
    • (1994) Am J Sports Med , vol.22 , pp. 211-218
    • Aglietti, P.1    Buzzi, R.2    Zaccherotti, G.3
  • 3
    • 0027508563 scopus 로고
    • The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
    • Brown CH Jr, Hecker AT, Hipp JA, et al: The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 21: 880-886, 1993
    • (1993) Am J Sports Med , vol.21 , pp. 880-886
    • Brown Ch., Jr.1    Hecker, A.T.2    Hipp, J.A.3
  • 4
    • 0029704294 scopus 로고    scopus 로고
    • Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: Influence of insertion torque, tunnel-bone block gap, and interference
    • Brown GA, Pena F, Grøntvedt T, et al: Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: Influence of insertion torque, tunnel-bone block gap, and interference. Knee Surg Sports Traumatol Arthroscopy 3: 238-244, 1996
    • (1996) Knee Surg Sports Traumatol Arthroscopy , vol.3 , pp. 238-244
    • Brown, G.A.1    Pena, F.2    Grøntvedt, T.3
  • 5
    • 0024585607 scopus 로고
    • Mechanical properties of primate vascularized vs. Nonvascularized patellar tendon grafts; changes over time
    • Butler DL, Grood ES, Noyes FR, et al: Mechanical properties of primate vascularized vs. nonvascularized patellar tendon grafts; changes over time. J Orthop Res 7: 68-79, 1989
    • (1989) J Orthop Res , vol.7 , pp. 68-79
    • Butler, D.L.1    Grood, E.S.2    Noyes, F.R.3
  • 6
    • 0344960895 scopus 로고
    • Effect of age and loading axis on the failure properties of the human ACL
    • Hollis JM, Lyon RM, Marin JP, et al: Effect of age and loading axis on the failure properties of the human ACL. Trans Orthop Res Soc 13: 83, 1988
    • (1988) Trans Orthop Res Soc , vol.13 , pp. 83
    • Hollis, J.M.1    Lyon, R.M.2    Marin, J.P.3
  • 7
    • 0028205110 scopus 로고
    • Pain after use of the central third of the patellar tendon for cruciate ligament reconstruction: 33 patients followed 2-3 years
    • Kleipool AE, Van Loon T, Marti RK: Pain after use of the central third of the patellar tendon for cruciate ligament reconstruction: 33 patients followed 2-3 years. Acta Orthop Scand 65: 62-66, 1994
    • (1994) Acta Orthop Scand , vol.65 , pp. 62-66
    • Kleipool, A.E.1    Van Loon, T.2    Marti, R.K.3
  • 8
    • 0014619661 scopus 로고
    • Function of the knee joint in various activities
    • Morrison JB: Function of the knee joint in various activities. Biomed Eng 4: 573-580, 1969
    • (1969) Biomed Eng , vol.4 , pp. 573-580
    • Morrison, J.B.1
  • 9
    • 0000519766 scopus 로고
    • Bioengineering analysis of force actions transmitted by the knee joint
    • Morrison JB: Bioengineering analysis of force actions transmitted by the knee joint. J Biomed Eng 3: 164-170, 1968
    • (1968) J Biomed Eng , vol.3 , pp. 164-170
    • Morrison, J.B.1
  • 10
    • 0026399695 scopus 로고
    • The effects of an extra-articular procedure on allograft reconstructions for chronic ruptures of the anterior cruciate ligament
    • Noyes FR, Barber SD: The effects of an extra-articular procedure on allograft reconstructions for chronic ruptures of the anterior cruciate ligament. J Bone Joint Surg 73A: 882-892, 1991
    • (1991) J Bone Joint Surg , vol.73 A , pp. 882-892
    • Noyes, F.R.1    Barber, S.D.2
  • 11
    • 0021337787 scopus 로고
    • Biomechanical analysis of human ligament grafts used in knee ligament repairs and reconstructions
    • Noyes FR, Butler DL, Grood ES, et al: Biomechanical analysis of human ligament grafts used in knee ligament repairs and reconstructions. J Bone Joint Surg 66A: 344-352, 1984
    • (1984) J Bone Joint Surg , vol.66 A , pp. 344-352
    • Noyes, F.R.1    Butler, D.L.2    Grood, E.S.3
  • 12
    • 0017032804 scopus 로고
    • The strength of the anterior cruciate ligament in humans and rhesus monkeys: Age-related and species-related changes
    • Noyes FR, Grood ES: The strength of the anterior cruciate ligament in humans and rhesus monkeys: Age-related and species-related changes. J Bone Joint Surg 58A: 1074-1082, 1976
    • (1976) J Bone Joint Surg , vol.58 A , pp. 1074-1082
    • Noyes, F.R.1    Grood, E.S.2
  • 13
    • 0020000032 scopus 로고
    • The cryo-jaw. A clamp designed for in vitro rheology studies of horse digital flexor tendons
    • Riemersa DJ, Schamhardt HC: The cryo-jaw. A clamp designed for in vitro rheology studies of horse digital flexor tendons. J Biomech 15: 619-620, 1982
    • (1982) J Biomech , vol.15 , pp. 619-620
    • Riemersa, D.J.1    Schamhardt, H.C.2
  • 14
    • 0027733655 scopus 로고
    • Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog
    • Rodeo SA, Amoczky SP, Torzilli PA, et al: Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog. J Bone Joint Surg 75A: 1795-1803, 1993
    • (1993) J Bone Joint Surg , vol.75 A , pp. 1795-1803
    • Rodeo, S.A.1    Amoczky, S.P.2    Torzilli, P.A.3
  • 15
    • 0031006780 scopus 로고    scopus 로고
    • A biomechanical evaluation of suture anchors in repair of the rotator cuff
    • Rossouw DJ, McElroy BJ, Amis AA, et al: A biomechanical evaluation of suture anchors in repair of the rotator cuff. J Bone Joint Surg 79B: 458-461, 1997
    • (1997) J Bone Joint Surg , vol.79 B , pp. 458-461
    • Rossouw, D.J.1    McElroy, B.J.2    Amis, A.A.3
  • 16
    • 0031087899 scopus 로고    scopus 로고
    • Assessment of morbidity of semitendinosus and gracilis tendon harvest for ACL reconstruction
    • Simonian PT, Harrison SD, Cooley VJ, et al: Assessment of morbidity of semitendinosus and gracilis tendon harvest for ACL reconstruction. Am J Knee Surg 10: 54-59, 1997
    • (1997) Am J Knee Surg , vol.10 , pp. 54-59
    • Simonian, P.T.1    Harrison, S.D.2    Cooley, V.J.3
  • 17
    • 0022971062 scopus 로고
    • Substitution of the anterior cruciate ligament: A long-term histologic and biomechanical study with autogenous pedicled grafts of the iliotibial band in dogs
    • Van Rens TJG, van den Berg AF, Huiskes R, et al: Substitution of the anterior cruciate ligament: A long-term histologic and biomechanical study with autogenous pedicled grafts of the iliotibial band in dogs. Arthroscopy 2: 139-154, 1986
    • (1986) Arthroscopy , vol.2 , pp. 139-154
    • Van Rens, T.J.G.1    Van Den Berg, A.F.2    Huiskes, R.3
  • 18
    • 0031194073 scopus 로고    scopus 로고
    • In vivo tensile behavior of a four-bundle hamstring graft as a replacement for the anterior cruciate ligament
    • Wallace MP, Howell SM, Hull ML: In vivo tensile behavior of a four-bundle hamstring graft as a replacement for the anterior cruciate ligament. J Orthop Res 15: 539-545, 1997
    • (1997) J Orthop Res , vol.15 , pp. 539-545
    • Wallace, M.P.1    Howell, S.M.2    Hull, M.L.3
  • 19
    • 0031931882 scopus 로고    scopus 로고
    • Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone
    • Weiler A, Hoffmann RFG, Stähelin AC, et al: Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone. Arthroscopy 14: 29-37, 1998
    • (1998) Arthroscopy , vol.14 , pp. 29-37
    • Weiler, A.1    Hoffmann, R.F.G.2    Stähelin, A.C.3
  • 20
    • 0031885152 scopus 로고    scopus 로고
    • Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws
    • Weiler A, Windhagen HJ, Raschke MJ, et al: Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26: 119-128, 1998
    • (1998) Am J Sports Med , vol.26 , pp. 119-128
    • Weiler, A.1    Windhagen, H.J.2    Raschke, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.