메뉴 건너뛰기




Volumn 24, Issue 7, 2008, Pages 817-823

Bioabsorbable Versus Titanium Interference Screws With Hamstring Autograft in Anterior Cruciate Ligament Reconstruction: A Prospective Randomized Trial With 2-Year Follow-up

Author keywords

Anterior cruciate ligament; Bioabsorbable; Hamstring autograft; Interference screws

Indexed keywords

HYDROXYAPATITE; POLYLACTIC ACID; TITANIUM;

EID: 45849144741     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2008.02.011     Document Type: Article
Times cited : (57)

References (18)
  • 1
    • 34250783880 scopus 로고    scopus 로고
    • A 10-year comparison of anterior cruciate ligament reconstructions with hamstring tendon and patellar tendon autograft: A controlled, prospective trial
    • Pinczewski L.A., Lyman J., Salmon L.J., Russell V.J., Roe J., and Linklater J. A 10-year comparison of anterior cruciate ligament reconstructions with hamstring tendon and patellar tendon autograft: A controlled, prospective trial. Am J Sports Med 35 (2007) 564-574
    • (2007) Am J Sports Med , vol.35 , pp. 564-574
    • Pinczewski, L.A.1    Lyman, J.2    Salmon, L.J.3    Russell, V.J.4    Roe, J.5    Linklater, J.6
  • 3
    • 13744265500 scopus 로고    scopus 로고
    • Is bone tunnel osseointegration in hamstring tendon autograft anterior cruciate ligament reconstruction important?
    • Logan M., Williams A., and Myers P. Is bone tunnel osseointegration in hamstring tendon autograft anterior cruciate ligament reconstruction important?. Arthroscopy 19 (2003) E1-E3
    • (2003) Arthroscopy , vol.19
    • Logan, M.1    Williams, A.2    Myers, P.3
  • 5
    • 7544231430 scopus 로고    scopus 로고
    • A comparison of bone tunnel measurements made using computed tomography and digital plain radiography after anterior cruciate ligament reconstruction
    • Webster K.E., Feller J.A., Elliott J., Hutchison A., and Payne R. A comparison of bone tunnel measurements made using computed tomography and digital plain radiography after anterior cruciate ligament reconstruction. Arthroscopy 20 (2004) 946-950
    • (2004) Arthroscopy , vol.20 , pp. 946-950
    • Webster, K.E.1    Feller, J.A.2    Elliott, J.3    Hutchison, A.4    Payne, R.5
  • 6
    • 13444303976 scopus 로고    scopus 로고
    • A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws
    • Kaeding C., Farr J., Kavanaugh T., and Pedroza A. A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws. Arthroscopy 21 (2005) 147-151
    • (2005) Arthroscopy , vol.21 , pp. 147-151
    • Kaeding, C.1    Farr, J.2    Kavanaugh, T.3    Pedroza, A.4
  • 7
    • 22944441915 scopus 로고    scopus 로고
    • Endoscopic reconstruction of the anterior cruciate ligament using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws: A prospective randomized study of the clinical outcome
    • Drogset J.O., Grontvedt T., and Tegnander A. Endoscopic reconstruction of the anterior cruciate ligament using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws: A prospective randomized study of the clinical outcome. Am J Sports Med 33 (2005) 1160-1165
    • (2005) Am J Sports Med , vol.33 , pp. 1160-1165
    • Drogset, J.O.1    Grontvedt, T.2    Tegnander, A.3
  • 8
    • 33750428192 scopus 로고    scopus 로고
    • Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: In vitro study comparing titanium, poly-D,L-lactide, and poly-D,L-lactide-tricalcium phosphate screws
    • Zantop T., Weimann A., Schmidtko R., Herbort M., Raschke M.J., and Petersen W. Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: In vitro study comparing titanium, poly-D,L-lactide, and poly-D,L-lactide-tricalcium phosphate screws. Arthroscopy 22 (2006) 1204-1210
    • (2006) Arthroscopy , vol.22 , pp. 1204-1210
    • Zantop, T.1    Weimann, A.2    Schmidtko, R.3    Herbort, M.4    Raschke, M.J.5    Petersen, W.6
  • 9
    • 23244443051 scopus 로고    scopus 로고
    • Soft-tissue interference fixation: Bioabsorbable screw versus metal screw
    • Brand J.J.C., Nyland J., Caborn D.N.M., and Johnson D.L. Soft-tissue interference fixation: Bioabsorbable screw versus metal screw. Arthroscopy 21 (2005) 911-916
    • (2005) Arthroscopy , vol.21 , pp. 911-916
    • Brand, J.J.C.1    Nyland, J.2    Caborn, D.N.M.3    Johnson, D.L.4
  • 10
    • 0031885152 scopus 로고    scopus 로고
    • Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws
    • Weiler A., Windhagen H.J., Raschke M.J., Laumeyer A., and Hoffmann R.F.G. Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26 (1998) 119-128
    • (1998) Am J Sports Med , vol.26 , pp. 119-128
    • Weiler, A.1    Windhagen, H.J.2    Raschke, M.J.3    Laumeyer, A.4    Hoffmann, R.F.G.5
  • 11
    • 0035413031 scopus 로고    scopus 로고
    • Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction
    • Lajtai G., Schmiedhuber G., Unger F., et al. Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction. Arthroscopy 17 (2001) 597-602
    • (2001) Arthroscopy , vol.17 , pp. 597-602
    • Lajtai, G.1    Schmiedhuber, G.2    Unger, F.3
  • 12
    • 20344362157 scopus 로고    scopus 로고
    • The natural history of a bioabsorbable interference screw used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique
    • Radford M.J., Noakes J., Read J., and Wood D.G. The natural history of a bioabsorbable interference screw used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique. Arthroscopy 21 (2005) 707-710
    • (2005) Arthroscopy , vol.21 , pp. 707-710
    • Radford, M.J.1    Noakes, J.2    Read, J.3    Wood, D.G.4
  • 13
    • 0036828516 scopus 로고    scopus 로고
    • Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up
    • Bach F.D., Carlier R.Y., Elis J.B., et al. Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up. Radiology 225 (2002) 541-550
    • (2002) Radiology , vol.225 , pp. 541-550
    • Bach, F.D.1    Carlier, R.Y.2    Elis, J.B.3
  • 14
    • 43049083366 scopus 로고    scopus 로고
    • Ten-year magnetic resonance imaging follow-up of bioabsorbable poly-L-lactic acid interference screws after anterior cruciate ligament reconstruction
    • Available online at www.arthroscopyjournal.org
    • Warden W.H., Chooljian D., and Jackson W.D. Ten-year magnetic resonance imaging follow-up of bioabsorbable poly-L-lactic acid interference screws after anterior cruciate ligament reconstruction. Arthroscopy 24 (2008) 370.e1-370.e3. http://www.arthroscopyjournal.org Available online at www.arthroscopyjournal.org
    • (2008) Arthroscopy , vol.24
    • Warden, W.H.1    Chooljian, D.2    Jackson, W.D.3
  • 15
    • 0025334647 scopus 로고
    • Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
    • Bostman O., Hirvensalo E., Makinen J., and Rokkanen P. Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 72 (1990) 592-596
    • (1990) J Bone Joint Surg Br , vol.72 , pp. 592-596
    • Bostman, O.1    Hirvensalo, E.2    Makinen, J.3    Rokkanen, P.4
  • 16
    • 0026513175 scopus 로고
    • Severe aseptic synovitis of the knee after biodegradable internal fixation. A case report
    • Friden T., and Rydholm U. Severe aseptic synovitis of the knee after biodegradable internal fixation. A case report. Acta Orthop Scand 63 (1992) 94-97
    • (1992) Acta Orthop Scand , vol.63 , pp. 94-97
    • Friden, T.1    Rydholm, U.2
  • 17
    • 0029891715 scopus 로고    scopus 로고
    • Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: Experimental study in sheep
    • Weiler A., Helling H.J., Kirch U., Zirbes T.K., and Rehm K.E. Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: Experimental study in sheep. J Bone Joint Surg Br 78 (1996) 369-376
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 369-376
    • Weiler, A.1    Helling, H.J.2    Kirch, U.3    Zirbes, T.K.4    Rehm, K.E.5
  • 18
    • 33644870933 scopus 로고    scopus 로고
    • Reduced bone tunnel enlargement post hamstring ACL reconstruction with poly-L-lactic acid/hydroxyapatite bioabsorbable screws
    • Robinson J., Huber C., Jaraj P., Colombet P., Allard M., and Meyer P. Reduced bone tunnel enlargement post hamstring ACL reconstruction with poly-L-lactic acid/hydroxyapatite bioabsorbable screws. Knee 13 (2006) 127-131
    • (2006) Knee , vol.13 , pp. 127-131
    • Robinson, J.1    Huber, C.2    Jaraj, P.3    Colombet, P.4    Allard, M.5    Meyer, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.