메뉴 건너뛰기




Volumn 45, Issue 3-6, 2010, Pages 663-667

Performance of a near-real-time KBr:Eu dosimetry system under computed tomography x-rays

Author keywords

OSL dosimetry; Real time dosimetry; Remote dosimetry

Indexed keywords

ACTIVE DOSIMETRY; COMPUTED TOMOGRAPHY; COMPUTED TOMOGRAPHY SCAN; DOSE MEASUREMENT; DOSE RESPONSE; DYNAMIC RADIATION; FAST DATA ACQUISITION; FIBEROPTIC CABLES; HELICAL CT; HIGH RESOLUTION; NEAR-REAL TIME; OPTICALLY STIMULATED LUMINESCENCE; OSL DOSIMETRY; PASSIVE DETECTORS; PENCIL IONIZATION CHAMBERS; QUANTITATIVE CT; RADIATION FIELD; REAL-TIME DOSIMETRY; THERMOLUMINESCENT DOSIMETERS; VOLUME DETECTORS; X-RAY ENERGIES;

EID: 77955304653     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2009.11.043     Document Type: Conference Paper
Times cited : (12)

References (14)
  • 3
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
    • A.S. Beddar, T.R. Mackie, and F.H. Attix Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations Phys. Med. Biol. 37 1992 1883 1900
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    MacKie, T.R.2    Attix, F.H.3
  • 4
    • 0026793771 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements
    • A.S. Beddar, T.R. Mackie, and F.H. Attix Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements Phys. Med. Biol. 37 1992 1901 1913
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1901-1913
    • Beddar, A.S.1    MacKie, T.R.2    Attix, F.H.3
  • 5
    • 0038038881 scopus 로고    scopus 로고
    • A new look at CT dose measurement: Beyond CTDI
    • R.L. Dixon A new look at CT dose measurement: beyond CTDI Med. Phys. 30 2003 1272 1280
    • (2003) Med. Phys. , vol.30 , pp. 1272-1280
    • Dixon, R.L.1
  • 7
    • 33749837281 scopus 로고    scopus 로고
    • A real-time, high-resolution optical fibre dosemeter based on optically stimulated luminescence (OSL) of KBr:Eu, for potential use during the radiotherapy of cancer
    • R. Gaza, and S.W.S. McKeever A real-time, high-resolution optical fibre dosemeter based on optically stimulated luminescence (OSL) of KBr:Eu, for potential use during the radiotherapy of cancer Radiat. Prot. Dosim. 120 2006 14 19
    • (2006) Radiat. Prot. Dosim. , vol.120 , pp. 14-19
    • Gaza, R.1    McKeever, S.W.S.2
  • 9
    • 65449186206 scopus 로고    scopus 로고
    • Characterization of water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology
    • D.E. Hyer, R.F. Fisher, and D.E. Hintenlang Characterization of water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology Med. Phys. 36 2009 1711 1716
    • (2009) Med. Phys. , vol.36 , pp. 1711-1716
    • Hyer, D.E.1    Fisher, R.F.2    Hintenlang, D.E.3
  • 10
    • 27244438116 scopus 로고    scopus 로고
    • MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies
    • A.K. Jones, F.D. Pazik, D.E. Hintenlang, and W.E. Bolch MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies Med. Phys. 32 2005 3209 3213
    • (2005) Med. Phys. , vol.32 , pp. 3209-3213
    • Jones, A.K.1    Pazik, F.D.2    Hintenlang, D.E.3    Bolch, W.E.4
  • 12
    • 17844409887 scopus 로고    scopus 로고
    • Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry
    • S. Mori, M. Endo, K. Nishizawa, T. Tsunoo, T. Aoyama, H. Fujiwara, and K. Murase Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry Med. Phys. 32 2005 1061 1069
    • (2005) Med. Phys. , vol.32 , pp. 1061-1069
    • Mori, S.1    Endo, M.2    Nishizawa, K.3    Tsunoo, T.4    Aoyama, T.5    Fujiwara, H.6    Murase, K.7
  • 13
    • 1942420364 scopus 로고    scopus 로고
    • Dose rate and SSD dependence of commercially available diode detectors
    • A. Saini, and T. Zhu Dose rate and SSD dependence of commercially available diode detectors Med. Phys. 31 2004 914 924
    • (2004) Med. Phys. , vol.31 , pp. 914-924
    • Saini, A.1    Zhu, T.2
  • 14
    • 34247626996 scopus 로고    scopus 로고
    • Energy dependence of commercially available diode detectors for in-vivo dosimetry
    • A. Saini, and T. Zhu Energy dependence of commercially available diode detectors for in-vivo dosimetry Med. Phys. 34 2007 1704 1711
    • (2007) Med. Phys. , vol.34 , pp. 1704-1711
    • Saini, A.1    Zhu, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.