메뉴 건너뛰기




Volumn 32, Issue 10, 2005, Pages 3209-3213

MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies

Author keywords

Depth dose; Monte Carlo simulation; MOSFET dosimeter; Newborn phantoms; Pediatric radiology; Tissue equivalent plastic

Indexed keywords

DIAGNOSIS; DOSIMETERS; FACINGS; METALS; MONTE CARLO METHODS; MOS DEVICES; MOSFET DEVICES; OXIDE SEMICONDUCTORS; PEDIATRICS; PHANTOMS; PHOTONS; X RAYS;

EID: 27244438116     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2047827     Document Type: Article
Times cited : (19)

References (23)
  • 2
    • 0028939777 scopus 로고
    • Real-time in vivo measurement of radiation dose during radioimmunotherapy in mice using a miniature MOSFET dosimeter probe
    • D. J. Gladstone and L. M. Chin, "Real-time in vivo measurement of radiation dose during radioimmunotherapy in mice using a miniature MOSFET dosimeter probe," Radiat. Res. 141, 330-335 (1995).
    • (1995) Radiat. Res. , vol.141 , pp. 330-335
    • Gladstone, D.J.1    Chin, L.M.2
  • 7
    • 0028213977 scopus 로고
    • Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter
    • M. Soubra, J. Cygler, and G. Mackay, "Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter," Med. Phys. 21, 567-572 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.2    Mackay, G.3
  • 8
    • 0036939468 scopus 로고    scopus 로고
    • A survey of radiation dose associated with pediatric plain-film chest X-ray examinations
    • K. M. Hintenlang, J. L. Williams, and D. E. Hintenlang, "A survey of radiation dose associated with pediatric plain-film chest X-ray examinations," Pediatr. Radiol. 32, 771-777 (2002).
    • (2002) Pediatr. Radiol. , vol.32 , pp. 771-777
    • Hintenlang, K.M.1    Williams, J.L.2    Hintenlang, D.E.3
  • 10
    • 33646666302 scopus 로고    scopus 로고
    • Characterization of MOSFET dosimeters for applications in mammography dosimetry
    • L. Benevides and D. Hintenlang, "Characterization of MOSFET dosimeters for applications in mammography dosimetry [Abstract]," Med. Phys. 30, 1422 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1422
    • Benevides, L.1    Hintenlang, D.2
  • 11
    • 0031868395 scopus 로고    scopus 로고
    • The characterization of a commercial MOSFET dosimeter system for use in diagnostic x-ray
    • M. W. Bower and D. E. Hintenlang, "The characterization of a commercial MOSFET dosimeter system for use in diagnostic x-ray," Health Phys. 75, 197-204 (1998).
    • (1998) Health Phys. , vol.75 , pp. 197-204
    • Bower, M.W.1    Hintenlang, D.E.2
  • 12
    • 0037368686 scopus 로고    scopus 로고
    • Characterization of the angular response of an "isotropic" MOSFET dosimeter
    • J. N. Roshau and D. E. Hintenlang, "Characterization of the angular response of an "isotropic" MOSFET dosimeter," Health Phys. 84, 376-379 (2003).
    • (2003) Health Phys. , vol.84 , pp. 376-379
    • Roshau, J.N.1    Hintenlang, D.E.2
  • 13
    • 0033013459 scopus 로고    scopus 로고
    • Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology
    • D. J. Peet and M. D. Pryor, "Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology," Br. J. Radiol. 72, 562-568 (1999).
    • (1999) Br. J. Radiol. , vol.72 , pp. 562-568
    • Peet, D.J.1    Pryor, M.D.2
  • 15
    • 33646659354 scopus 로고    scopus 로고
    • Dissertation, Department of Nuclear & Radiological Engineering University of Florida, Gainesville, FL
    • L. Benedives, "Breast dosimetry in clinical mammography," Dissertation, Department of Nuclear & Radiological Engineering (University of Florida, Gainesville, FL, 2005).
    • (2005) Breast Dosimetry in Clinical Mammography
    • Benedives, L.1
  • 16
    • 0031441616 scopus 로고    scopus 로고
    • The response of a MOSFET, p-type semiconductor, and LiF TLD to quasimonoenergetic x-rays
    • C. R. Edwards, S. Green, J. E. Palethorpe, and P. J. Mountford, "The response of a MOSFET, p-type semiconductor, and LiF TLD to quasimonoenergetic x-rays," Phys. Med. Biol. 42, 2383-2391 (1997).
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2383-2391
    • Edwards, C.R.1    Green, S.2    Palethorpe, J.E.3    Mountford, P.J.4
  • 17
  • 18
    • 0035990013 scopus 로고    scopus 로고
    • Comparisons of point and average organ dose within an anthropomorphic physical phantom and a computational model of the newborn patient
    • J. Sessions, J. Roshau, M. Tressler, D. Hintenlang, M. Arreola, J. Williams, and W. Bolch, "Comparisons of point and average organ dose within an anthropomorphic physical phantom and a computational model of the newborn patient," Med. Phys. 29, 1080-1089 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1080-1089
    • Sessions, J.1    Roshau, J.2    Tressler, M.3    Hintenlang, D.4    Arreola, M.5    Williams, J.6    Bolch, W.7
  • 19
    • 0041887307 scopus 로고    scopus 로고
    • Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology
    • A. K. Jones, D. E. Hintenlang, and W. E. Bolch, "Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology," Med. Phys. 30, 2072-2081 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2072-2081
    • Jones, A.K.1    Hintenlang, D.E.2    Bolch, W.E.3
  • 22
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV
    • J. M. Boone and J. A. Seibert, "An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV," Med. Phys. 24, 1661-1670 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 23
    • 2442646488 scopus 로고    scopus 로고
    • Monte Carlo modeling of a high-sensitivity MOSFET dosimeter for low- and medium-energy photon sources
    • B. Wang, C. H. Kim, and X. G. Xua, "Monte Carlo modeling of a high-sensitivity MOSFET dosimeter for low- and medium-energy photon sources," Med. Phys. 31, 1003-1008 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 1003-1008
    • Wang, B.1    Kim, C.H.2    Xua, X.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.