메뉴 건너뛰기




Volumn 47, Issue 6, 2010, Pages 446-453

Biomechanical changes of the lumbar segment after total disc replacement: Charite®, prodisc® and maverick® using finite element model study

Author keywords

Artificial disc; Facet contact load; Finite element model; Lumbar spine; Rotation angle; von Mises stress

Indexed keywords

ANALYTICAL PARAMETERS; ARTICLE; BIOMECHANICS; COMPUTER MODEL; CONTROLLED STUDY; FINITE ELEMENT ANALYSIS; IMPLANT; LUMBAR DISK; ROTATION; SPINE MOBILITY; VALIDATION PROCESS; WEIGHT BEARING;

EID: 77955194428     PISSN: 20053711     EISSN: 15987876     Source Type: Journal    
DOI: 10.3340/jkns.2010.47.6.446     Document Type: Article
Times cited : (39)

References (27)
  • 1
    • 77955222583 scopus 로고    scopus 로고
    • Analysis of compression behavior in lumbar spine under simple vertical load vs follower load
    • Ahn MW, Shin KS, Lee JW, Chung IS, Lee CY: Analysis of compression behavior in lumbar spine under simple vertical load vs follower load. J Korean Soc Spine Surg 9: 78-83, 2002
    • (2002) J Korean Soc Spine Surg , vol.9 , pp. 78-83
    • Ahn, M.W.1    Shin, K.S.2    Lee, J.W.3    Chung, I.S.4    Lee, C.Y.5
  • 2
    • 0033567865 scopus 로고    scopus 로고
    • Study of fatigue resistance of chemical and radiation cross linked medical grade ultrahigh molecular weight polyethylene
    • Baker DA, Hastings RS, Pruitt L: Study of fatigue resistance of chemical and radiation cross linked medical grade ultrahigh molecular weight polyethylene. J Biomed Mater Res 46: 573-581, 1999
    • (1999) J Biomed Mater Res , vol.46 , pp. 573-581
    • Baker, D.A.1    Hastings, R.S.2    Pruitt, L.3
  • 3
    • 33748575947 scopus 로고    scopus 로고
    • Total disc replacement in the lumbar spine: A systematic review of the literature
    • Freeman BJ, Davenport J: Total disc replacement in the lumbar spine: a systematic review of the literature. Eur Spine J 15: S439- S447, 2006
    • (2006) Eur Spine J , vol.15
    • Freeman, B.J.1    Davenport, J.2
  • 4
    • 13744256317 scopus 로고    scopus 로고
    • Biomechanical analysis of the disc adjacent to posterolateral fusion with laminectomy in lumbar spine
    • Chen CS, Feng CK, Cheng CK, Tzeng MJ, Liu CL, Chen WJ: Biomechanical analysis of the disc adjacent to posterolateral fusion with laminectomy in lumbar spine. J Spinal Disorders Tech 18: 58-65, 2005
    • (2005) J Spinal Disorders Tech , vol.18 , pp. 58-65
    • Chen, C.S.1    Feng, C.K.2    Cheng, C.K.3    Tzeng, M.J.4    Liu, C.L.5    Chen, W.J.6
  • 5
    • 12744268815 scopus 로고    scopus 로고
    • Surgical treatment of adjacent instability after lumbar spine fusion
    • Chen WJ, Lai PL, Niu CC, Chen LH, Fu TS, Wong CB: Surgical treatment of adjacent instability after lumbar spine fusion. Spine 26: E519-E524, 2001
    • (2001) Spine , vol.26
    • Chen, W.J.1    Lai, P.L.2    Niu, C.C.3    Chen, L.H.4    Fu, T.S.5    Wong, C.B.6
  • 6
    • 67651166795 scopus 로고    scopus 로고
    • Biomechanical effect of constraint in lumbar total disc replacement: A study with finite element analysis
    • Chung SK, Kim YE, Wang KC: Biomechanical effect of constraint in lumbar total disc replacement: a study with finite element analysis. Spine (Phila Pa 1976) 34: 1281-1286, 2009
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. 1281-1286
    • Chung, S.K.1    Kim, Y.E.2    Wang, K.C.3
  • 7
    • 0142026310 scopus 로고    scopus 로고
    • Biomechanical evaluation of total disc replacement arthroplasty: An in vitro human cadaveric model
    • Cunningham BW, Gordon JD, Dmitriev AE, Hu N McAfee PC: Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model. Spine (Phila Pa 1976) 28: S110- S117, 2003
    • (2003) Spine (Phila Pa 1976) , vol.28
    • Cunningham, B.W.1    Gordon, J.D.2    Dmitriev, A.E.3    Hu, N.4    McAfee, P.C.5
  • 8
    • 21544465887 scopus 로고    scopus 로고
    • Revision of a Charité artificial disc 9.5 years in vivo to a new Charité artificial disc: Case report and explant analysis
    • David T: Revision of a Charité artificial disc 9.5 years in vivo to a new Charité artificial disc: case report and explant analysis. Eur Spine J 14: 507-511, 2005
    • (2005) Eur Spine J , vol.14 , pp. 507-511
    • David, T.1
  • 9
    • 0037657652 scopus 로고    scopus 로고
    • Total disc replacement for chronic low back pain: Background and a systematic review of the literature
    • de Kleuver M, Oner FC, Jacobs WC: Total disc replacement for chronic low back pain: background and a systematic review of the literature. Eur Spine J 12: 108-116, 2003
    • (2003) Eur Spine J , vol.12 , pp. 108-116
    • de Kleuver, M.1    Oner, F.C.2    Jacobs, W.C.3
  • 10
    • 18044403309 scopus 로고    scopus 로고
    • Load-sharing between anterior and posterior elements in a lumbar motion segment implanted with an artificial disc
    • Dooris AP, Goel VK, Grosland NM, Gilbertson LG, Wilder DG: Load-sharing between anterior and posterior elements in a lumbar motion segment implanted with an artificial disc. Spine (Phila Pa 1976) 26: E122-E129, 2001
    • (2001) Spine (Phila Pa 1976) , vol.26
    • Dooris, A.P.1    Goel, V.K.2    Grosland, N.M.3    Gilbertson, L.G.4    Wilder, D.G.5
  • 11
    • 4544230545 scopus 로고    scopus 로고
    • Neurological complications of lumbar artificial disc replacement and comparison of clinical results with those related to lumbar arthrodesis in the literature: Results of a multicenter, prospective, randomized investigational device exemption study of Charité intervertebral disc. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves
    • March 2004
    • Geisler FH, Blumenthal SL, Guyer RD, McAfee PC, Regan JJ, Johnson JP, et al.: Neurological complications of lumbar artificial disc replacement and comparison of clinical results with those related to lumbar arthrodesis in the literature: results of a multicenter, prospective, randomized investigational device exemption study of Charité intervertebral disc. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004. J Neurosurg Spine 1: 143-154, 2004
    • (2004) J Neurosurg Spine , vol.1 , pp. 143-154
    • Geisler, F.H.1    Blumenthal, S.L.2    Guyer, R.D.3    McAfee, P.C.4    Regan, J.J.5    Johnson, J.P.6
  • 12
    • 0041511932 scopus 로고    scopus 로고
    • Effects of lumbar spinal fusion on the other lumbar intervertebral levels (three-dimensional finite element analysis)
    • Goto K, Tajima N, Chosa E, Totoribe K, Kubo S, Kuroki H, et al.: Effects of lumbar spinal fusion on the other lumbar intervertebral levels (three-dimensional finite element analysis). J Orthop Sci 8: 577-584, 2003
    • (2003) J Orthop Sci , vol.8 , pp. 577-584
    • Goto, K.1    Tajima, N.2    Chosa, E.3    Totoribe, K.4    Kubo, S.5    Kuroki, H.6
  • 13
    • 33646507647 scopus 로고    scopus 로고
    • Finite element modeling of multi-level cervical spinal segments (C3-C6) and biomechanical analysis of an elastomer-type prosthetic disc
    • Ha SK: Finite element modeling of multi-level cervical spinal segments (C3-C6) and biomechanical analysis of an elastomer-type prosthetic disc. Med Eng Phys 28: 534-541, 2006
    • (2006) Med Eng Phys , vol.28 , pp. 534-541
    • Ha, S.K.1
  • 15
    • 76849100686 scopus 로고    scopus 로고
    • Biomechanical analysis of the implanted constrained and unconstrained ICR types of artificial disc using FE model
    • Kim YE, Yun SS, Jung SK: Biomechanical analysis of the implanted constrained and unconstrained ICR types of artificial disc using FE model. J of the KSPE 23: 176-182, 2006
    • (2006) J of the KSPE , vol.23 , pp. 176-182
    • Kim, Y.E.1    Yun, S.S.2    Jung, S.K.3
  • 16
    • 0033507460 scopus 로고    scopus 로고
    • Finite element modeling of the cervical spine: Role of intervertebral disc under axial and eccentric loads
    • Kumaresan S, Yoganandan N, Pintar FA, Maiman DJ: Finite element modeling of the cervical spine: role of intervertebral disc under axial and eccentric loads. Med Eng Physics 21: 689-700, 1999
    • (1999) Med Eng Physics , vol.21 , pp. 689-700
    • Kumaresan, S.1    Yoganandan, N.2    Pintar, F.A.3    Maiman, D.J.4
  • 17
    • 26044473353 scopus 로고    scopus 로고
    • Influence of facet and posterior muscle degeneration on clinical results of lumbar total disc replacement: Two-year follow-up
    • Le Huec JC, Basso Y, Aunoble S, Friesem T, Bruno MB: Influence of facet and posterior muscle degeneration on clinical results of lumbar total disc replacement: two-year follow-up. J Spinal Disord Tech 18: 219-223, 2005
    • (2005) J Spinal Disord Tech , vol.18 , pp. 219-223
    • le Huec, J.C.1    Basso, Y.2    Aunoble, S.3    Friesem, T.4    Bruno, M.B.5
  • 18
    • 22544457499 scopus 로고    scopus 로고
    • A prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: Part II: Evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes
    • discussion E388-E390
    • McAfee PC, Cunningham B, Holsapple G, Adams K, Blumenthal S, Guyer RD, et al.: A prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part II: evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes. Spine (Phila Pa 1976) 30: 1576-1583; discussion E388-E390, 2005
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 1576-1583
    • McAfee, P.C.1    Cunningham, B.2    Holsapple, G.3    Adams, K.4    Blumenthal, S.5    Guyer, R.D.6
  • 19
    • 0033568532 scopus 로고    scopus 로고
    • The influence of lumbar disc height and cross-sectional area on the mechanical response of the disc to physiologic loading
    • Natarajan RN, Andersson GB: The influence of lumbar disc height and cross-sectional area on the mechanical response of the disc to physiologic loading. Spine (Phila Pa 1976) 24: 1873-1881, 1999
    • (1999) Spine (Phila Pa 1976) , vol.24 , pp. 1873-1881
    • Natarajan, R.N.1    Andersson, G.B.2
  • 20
    • 1842523405 scopus 로고    scopus 로고
    • Statistical factorial analysis on the material property sensitivity of the mechanical responses of the C4-C6 under compression, anterior and posterior shear
    • Ng HW, Teo EC, Lee VS: Statistical factorial analysis on the material property sensitivity of the mechanical responses of the C4-C6 under compression, anterior and posterior shear. J Biomech 37: 771-777, 2004
    • (2004) J Biomech , vol.37 , pp. 771-777
    • Ng, H.W.1    Teo, E.C.2    Lee, V.S.3
  • 21
    • 0033562385 scopus 로고    scopus 로고
    • A follower load increases the load-carrying capacity of the lumbar spine in compression
    • Patwardhan AG, Havey RM, Meade KP, Lee B, Dunlap B: A follower load increases the load-carrying capacity of the lumbar spine in compression. Spine (Phila Pa 1976) 24: 1003-1009, 1999
    • (1999) Spine (Phila Pa 1976) , vol.24 , pp. 1003-1009
    • Patwardhan, A.G.1    Havey, R.M.2    Meade, K.P.3    Lee, B.4    Dunlap, B.5
  • 22
    • 18044403388 scopus 로고    scopus 로고
    • Influence of a follower load on intradiscal pressure and intersegmental rotation of the lumbar spine
    • Rohlmann A, Neller S, Claes L, Bergmann G, Wilke HJ: Influence of a follower load on intradiscal pressure and intersegmental rotation of the lumbar spine. Spine (Phila Pa 1976) 26: E557-E561, 2001
    • (2001) Spine (Phila Pa 1976) , vol.26
    • Rohlmann, A.1    Neller, S.2    Claes, L.3    Bergmann, G.4    Wilke, H.J.5
  • 23
    • 16844371695 scopus 로고    scopus 로고
    • Effect of total disc replacement with prodisc on intersegmental rotation of the lumbar spine
    • Rohlmann A, Zander T, Bergmann G: Effect of total disc replacement with prodisc on intersegmental rotation of the lumbar spine. Spine (Phila Pa 1976) 30: 738-743, 2005
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 738-743
    • Rohlmann, A.1    Zander, T.2    Bergmann, G.3
  • 24
    • 0041568267 scopus 로고    scopus 로고
    • Complications of artificial disc replacement: A report of 27 patients with the SB Charité disc
    • van Ooij A, Oner FC, Verbout AJ: Complications of artificial disc replacement: a report of 27 patients with the SB Charité disc. J Spinal Disord Tech 16: 369-383, 2003
    • (2003) J Spinal Disord Tech , vol.16 , pp. 369-383
    • van Ooij, A.1    Oner, F.C.2    Verbout, A.J.3
  • 25
    • 0033188797 scopus 로고    scopus 로고
    • Rate effect on sharing of passive lumbar motion segment under load-controlled sagittal flexion: Viscoelastic finite element analysis
    • Wang JL, Parnianpour M, Shirazi-Adl A, Engin AE: Rate effect on sharing of passive lumbar motion segment under load-controlled sagittal flexion: viscoelastic finite element analysis. Theoretical and Applied Fracture Mechanics 32: 119-128, 1999
    • (1999) Theoretical and Applied Fracture Mechanics , vol.32 , pp. 119-128
    • Wang, J.L.1    Parnianpour, M.2    Shirazi-Adl, A.3    Engin, A.E.4
  • 27
    • 0024819818 scopus 로고
    • Three-dimensional movements of the whole lumbar spine and lumbosacral joint
    • Yamamoto I, Panjabi MM, Crisco T, Oxland T: Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine (Phila Pa 1976) 14: 1256-1260, 1989
    • (1989) Spine (Phila Pa 1976) , vol.14 , pp. 1256-1260
    • Yamamoto, I.1    Panjabi, M.M.2    Crisco, T.3    Oxland, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.