메뉴 건너뛰기




Volumn 4, Issue 2, 2010, Pages 391-403

Real-time glucose estimation algorithm for continuous glucose monitoring using autoregressive models

Author keywords

Autoregressive model; Continuous glucose monitoring; Hypoglycemia; Type 1 diabetes

Indexed keywords

GLYCOSYLATED HEMOGLOBIN; HIGH DENSITY LIPOPROTEIN CHOLESTEROL; LIPID; LOW DENSITY LIPOPROTEIN CHOLESTEROL;

EID: 77954931627     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229681000400221     Document Type: Article
Times cited : (38)

References (37)
  • 1
    • 44849122819 scopus 로고    scopus 로고
    • Continuous glucose monitoring (CGM) reduces risks for hypo- and hyperglycemia and glucose variability in diabetes
    • Kovatchev B, Clarke WL. Continuous glucose monitoring (CGM) reduces risks for hypo- and hyperglycemia and glucose variability in diabetes. Diabetes. 2007;56(Suppl 1):A23.
    • (2007) Diabetes , vol.56 , Issue.SUPPL. 1
    • Kovatchev, B.1    Clarke, W.L.2
  • 2
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • DOI 10.2337/diacare.28.5.1231
    • Klonoff DC. Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care. 2005;28(5):1231-9. (Pubitemid 40616646)
    • (2005) Diabetes Care , vol.28 , Issue.5 , pp. 1231-1239
    • Klonoff, D.C.1
  • 3
    • 33845483509 scopus 로고    scopus 로고
    • Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
    • DOI 10.2337/dc06-1134
    • Deiss D, Bolinder J, Riveline JP, Battelino T, Bosi E, Tubiana-Rufi N, Kerr D, Phillip M. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care. 2006;29(12):2730-2. (Pubitemid 44912209)
    • (2006) Diabetes Care , vol.29 , Issue.12 , pp. 2730-2732
    • Deiss, D.1    Bolinder, J.2    Riveline, J.-P.3    Battelino, T.4    Bosi, E.5    Tubiana-Rufi, N.6    Kerr, D.7    Phillip, M.8
  • 5
    • 41749083036 scopus 로고    scopus 로고
    • Use of continuous glucose monitoring to improve diabetes mellitus management
    • DOI 10.1016/S0889-8529(07)80011-9, PII S0889852907800119
    • Ellis SL, Bookout T, Garg SK, Izuora KE. Use of continuous glucose monitoring to improve diabetes mellitus management. Endocrinol Metab Clin North Am. 2007;36 Suppl 2:46-68. (Pubitemid 351491608)
    • (2007) Endocrinology and Metabolism Clinics of North America , vol.36 , Issue.SUPPL. 2 , pp. 46-68
    • Ellis, S.L.1    Bookout, T.2    Garg, S.K.3    Izuora, K.E.4
  • 6
    • 59649089217 scopus 로고    scopus 로고
    • Modeling of calibration effectiveness and blood-to-interstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp
    • King C, Anderson SM, Breton M, Clarke WL, Kovatchev BP. Modeling of calibration effectiveness and blood-to-interstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp. J Diabetes Sci Technol. 2007;1(3):317-22.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.3 , pp. 317-322
    • King, C.1    Anderson, S.M.2    Breton, M.3    Clarke, W.L.4    Kovatchev, B.P.5
  • 8
    • 24944495481 scopus 로고    scopus 로고
    • Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia
    • DOI 10.1007/s00125-005-1852-x
    • Steil GM, Rebrin K, Hariri F, Jinagonda S, Tadros S, Darwin C, Saad MF. Interstitial fluid glucose dynamics during insulininduced hypoglycaemia. Diabetologia. 2005;48(9):1833-40. (Pubitemid 41317838)
    • (2005) Diabetologia , vol.48 , Issue.9 , pp. 1833-1840
    • Steil, G.M.1    Rebrin, K.2    Hariri, F.3    Jinagonda, S.4    Tadros, S.5    Darwin, C.6    Saad, M.F.7
  • 9
    • 73949126778 scopus 로고    scopus 로고
    • Analysis, modeling, and simulation of the accuracy of continuous glucose sensors
    • Breton M, Kovatchev BP. Analysis, modeling, and simulation of the accuracy of continuous glucose sensors. J Diabetes Sci Technol. 2008;2(5):853-62.
    • (2008) J Diabetes Sci Technol , vol.2 , Issue.5 , pp. 853-862
    • Breton, M.1    Kovatchev, B.P.2
  • 10
    • 70349245305 scopus 로고    scopus 로고
    • A tale of two compartments: Interstitial versus blood glucose monitoring
    • Cengiz E, Tamborlane WV. A tale of two compartments: interstitial versus blood glucose monitoring. Diabetes Technol Ther. 2009;11 Suppl 1:S11-6.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.SUPPL. 1
    • Cengiz, E.1    Tamborlane, W.V.2
  • 11
    • 0038285652 scopus 로고    scopus 로고
    • Analysis of continuous glucose monitoring data from non-diabetic and diabetic children: A tale of two algorithms
    • DOI 10.1089/152091503765691866
    • Weinzimer SA, DeLucia MC, Boland EA, Steffen A, Tamborlane WV. Analysis of continuous glucose monitoring data from non-diabetic and diabetic children: a tale of two algorithms. Diabetes Technol Ther. 2003;5(3):375-80. (Pubitemid 36676312)
    • (2003) Diabetes Technology and Therapeutics , vol.5 , Issue.3 , pp. 375-380
    • Weinzimer, S.A.1    Delucia, M.C.2    Boland, E.A.3    Steffen, A.4    Tamborlane, W.V.5
  • 12
    • 0042520949 scopus 로고    scopus 로고
    • Dawn of real-time continuous glucose sensing
    • DOI 10.1089/152091503765691875
    • Buckingham B. Analysis: dawn of real-time continuous glucose sensing. Diabetes Technol Ther. 2003;5(3):381-3. (Pubitemid 36676313)
    • (2003) Diabetes Technology and Therapeutics , vol.5 , Issue.3 , pp. 381-383
    • Buckingham, B.1
  • 14
    • 77649133392 scopus 로고    scopus 로고
    • Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: Role of sensor calibration
    • Facchinetti A, Sparacino G, Cobelli C. Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: role of sensor calibration. J Diabetes Sci Technol. 2007;1(5):617-23.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.5 , pp. 617-623
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 15
    • 34247468946 scopus 로고    scopus 로고
    • Calibration of the continuous glucose monitoring system for transient glucose monitoring
    • DOI 10.1089/dia.2006.0008
    • Lesperance LM, Spektor A, McLeod KJ. Calibration of the continuous glucose monitoring system for transient glucose monitoring. Diabetes Technol Ther. 2007;9(2):183-90. (Pubitemid 46652554)
    • (2007) Diabetes Technology and Therapeutics , vol.9 , Issue.2 , pp. 183-190
    • Lesperance, L.M.1    Spektor, A.2    Mcleod, K.J.3
  • 16
    • 64349107874 scopus 로고    scopus 로고
    • Estimation of future glucose concentrations with subject-specific recursive linear models
    • Eren-Oruklu M, Cinar A, Quinn L, Smith D. Estimation of future glucose concentrations with subject-specific recursive linear models. Diabetes Technol Ther. 2009;11(4):243-53.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.4 , pp. 243-253
    • Eren-Oruklu, M.1    Cinar, A.2    Quinn, L.3    Smith, D.4
  • 17
    • 35348855218 scopus 로고    scopus 로고
    • Practical issues in the identification of empirical models from simulated type 1 diabetes data
    • DOI 10.1089/dia.2007.0202
    • Finan DA, Zisser H, Jovanovic L, Bevier WC, Seborg DE. Practical issues in the identification of empirical models from simulated type 1 diabetes data. Diabetes Technol Ther. 2007;9(5):438-50. (Pubitemid 47585348)
    • (2007) Diabetes Technology and Therapeutics , vol.9 , Issue.5 , pp. 438-450
    • Finan, D.A.1    Zisser, H.2    Jovanovic, L.3    Bevier, W.C.4    Seborg, D.E.5
  • 19
    • 52449101078 scopus 로고    scopus 로고
    • Predictive monitoring for improved management of glucose levels
    • Reifman J, Rajaraman S, Gribok A, Ward WK. Predictive monitoring for improved management of glucose levels. J Diabetes Sci Technol. 2007;1(4):478-86.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.4 , pp. 478-486
    • Reifman, J.1    Rajaraman, S.2    Gribok, A.3    Ward, W.K.4
  • 20
    • 63849301691 scopus 로고    scopus 로고
    • Predicting subcutaneous glucose concentration in humans: Data-driven glucose modeling
    • Gani A, Gribok AV, Rajaraman S, Ward WK, Reifman J. Predicting subcutaneous glucose concentration in humans: data-driven glucose modeling. IEEE Trans Biomed Eng. 2009;56(2):246-54.
    • (2009) IEEE Trans Biomed Eng , vol.56 , Issue.2 , pp. 246-254
    • Gani, A.1    Gribok, A.V.2    Rajaraman, S.3    Ward, W.K.4    Reifman, J.5
  • 21
    • 54749134550 scopus 로고    scopus 로고
    • Continuous glucose sensors: Continuing questions about clinical accuracy
    • Clarke WL, Kovatchev B. Continuous glucose sensors: continuing questions about clinical accuracy. J Diabetes Sci Technol. 2007;1(5):669-75.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.5 , pp. 669-675
    • Clarke, W.L.1    Kovatchev, B.2
  • 22
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987;10(5):622-8. (Pubitemid 17158937)
    • (1987) Diabetes Care , vol.10 , Issue.5 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 23
    • 0033855803 scopus 로고    scopus 로고
    • A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose
    • Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000;23(8):1143-8. (Pubitemid 30616803)
    • (2000) Diabetes Care , vol.23 , Issue.8 , pp. 1143-1148
    • Parkes, J.L.1    Slatin, S.L.2    Pardo, S.3    Ginsberg, B.H.4
  • 27
    • 33644819026 scopus 로고    scopus 로고
    • Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients
    • DOI 10.2337/diacare.28.12.2871
    • Wentholt IM, Vollebregt MA, Hart AA, Hoekstra JB, DeVries JH. Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients. Diabetes Care. 2005;28(12):2871-6. (Pubitemid 43942917)
    • (2005) Diabetes Care , vol.28 , Issue.12 , pp. 2871-2876
    • Wentholt, I.M.1    Vollebregt, M.A.2    Hart, A.A.3    Hoekstra, J.B.4    DeVries, J.H.5
  • 28
    • 58449116859 scopus 로고    scopus 로고
    • Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems
    • Garg SK, Smith J, Beatson C, Lopez-Baca B, Voelmle M, Gottlieb PA. Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems. Diabetes Technol Ther. 2009;11(2):65-72.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.2 , pp. 65-72
    • Garg, S.K.1    Smith, J.2    Beatson, C.3    Lopez-Baca, B.4    Voelmle, M.5    Gottlieb, P.A.6
  • 30
    • 0003519349 scopus 로고    scopus 로고
    • MATLAB. Natick: The MathWorks, Inc.
    • .MATLAB. System Identification Toolbox. Natick: The MathWorks, Inc.; 2007.
    • (2007) System Identification Toolbox
  • 31
    • 34247600583 scopus 로고    scopus 로고
    • Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: Comparison with frequent laboratory reference measurements
    • DOI 10.2337/dc06-1602
    • Weinstein RL, Schwartz SL, Brazg RL, Bugler JR, Peyser TA, McGarraugh GV. Accuracy of the 5-day FreeStyle Navigator continuous glucose monitoring system: comparison with frequent laboratory reference measurements. Diabetes Care. 2007;30(5):1125-30. (Pubitemid 46684636)
    • (2007) Diabetes Care , vol.30 , Issue.5 , pp. 1125-1130
    • Weinstein, R.L.1    Schwartz, S.L.2    Brazg, R.L.3    Bugler, J.R.4    Peyser, T.A.5    McGarraugh, G.V.6
  • 32
    • 58149389636 scopus 로고    scopus 로고
    • Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?
    • .Mazze RS, Strock E, Borgman S, Wesley D, Stout P, Racchini J. Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): is CGM ready for real time? Diabetes Technol Ther. 2009;11(1):11-8.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.1 , pp. 11-18
    • Mazze, R.S.1    Strock, E.2    Borgman, S.3    Wesley, D.4    Stout, P.5    Racchini, J.6
  • 33
    • 48649110903 scopus 로고    scopus 로고
    • Comparison of the numerical and clinical accuracy of four continuous glucose monitors
    • Kovatchev B, Anderson S, Heinemann L, Clarke W. Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes Care. 2008;31(6):1160-4.
    • (2008) Diabetes Care , vol.31 , Issue.6 , pp. 1160-1164
    • Kovatchev, B.1    Anderson, S.2    Heinemann, L.3    Clarke, W.4
  • 34
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
    • DOI 10.2337/diacare.27.8.1922
    • .Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL. Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care. 2004;27(8):1922-8. (Pubitemid 38989233)
    • (2004) Diabetes Care , vol.27 , Issue.8 , pp. 1922-1928
    • Kovatchev, B.P.1    Gonder-Frederick, L.A.2    Cox, D.J.3    Clarke, W.L.4
  • 35
    • 1842583012 scopus 로고    scopus 로고
    • Alarms Based on Real-Time Sensor Glucose Values Alert Patients to Hypo- and Hyperglycemia: The Guardian Continuous Monitoring System
    • DOI 10.1089/152091504773731285
    • Bode B, Gross K, Rikalo N, Schwartz S, Wahl T, Page C, Gross T, Mastrototaro J. Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system. Diabetes Technol Ther. 2004;6(2):105-13. (Pubitemid 38445735)
    • (2004) Diabetes Technology and Therapeutics , vol.6 , Issue.2 , pp. 105-113
    • Bode, B.1    Gross, K.2    Rikalo, N.3    Schwartz, S.4    Wahl, T.5    Page, C.6    Gross, T.7    Mastrototaro, J.8
  • 36
    • 33845475479 scopus 로고    scopus 로고
    • 1c values: Safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor
    • DOI 10.2337/dc06-1361
    • Garg S, Jovanovič L. Relationship of fasting and hourly blood glucose levels to HbA1c values: safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor. Diabetes Care. 2006;29(12):2644-9. (Pubitemid 44912192)
    • (2006) Diabetes Care , vol.29 , Issue.12 , pp. 2644-2649
    • Garg, S.1    Jovanovic, L.2
  • 37
    • 64749099221 scopus 로고    scopus 로고
    • Feasibility of 10-day use of a continuous glucose-monitoring system in adults with type 1 diabetes
    • Garg SK, Voelmle MK, Gottlieb P. Feasibility of 10-day use of a continuous glucose-monitoring system in adults with type 1 diabetes. Diabetes Care. 2009;32(3):436-8.
    • (2009) Diabetes Care , vol.32 , Issue.3 , pp. 436-438
    • Garg, S.K.1    Voelmle, M.K.2    Gottlieb, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.