메뉴 건너뛰기




Volumn 38, Issue 8 SUPPL., 2010, Pages

Design of the environment of care for safety of patients and personnel: Does form follow function or vice versa in the intensive care unit?

Author keywords

intensive care unit design; nosocomial infection; patient safety; water quality

Indexed keywords

ASPERGILLUS; COST OF ILLNESS; DIALYSIS; ENVIRONMENTAL FACTOR; FUSARIUM; HAND WASHING; HEALTH CARE DELIVERY; HEALTH CARE QUALITY; INFECTION PREVENTION; INTENSIVE CARE UNIT; LEGIONELLA; PATIENT SAFETY; PRIORITY JOURNAL; REVIEW; SANITATION; WASTE DISPOSAL; WATER SUPPLY;

EID: 77954893553     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0b013e3181e6d0c1     Document Type: Article
Times cited : (42)

References (73)
  • 1
    • 0037174772 scopus 로고    scopus 로고
    • Guideline for hand hygiene in health-care settings: Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HICPAC/SHEA/APIC/IDSA Hand Hygiene Task Force
    • Centers for Disease Control and Prevention
    • Centers for Disease Control and Prevention: Guideline for hand hygiene in health-care settings: Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HICPAC/SHEA/APIC/IDSA Hand Hygiene Task Force. MMWR 2002; 51:1-45
    • (2002) MMWR , vol.51 , pp. 1-45
  • 2
    • 70349810294 scopus 로고    scopus 로고
    • World Health Organization Geneva, Switzerland, WHO Press, 2009. Available at Accessed August 30, 2009
    • World Health Organization: WHO guidelines on hand hygiene in health care. 2009. Geneva, Switzerland, WHO Press, 2009. Available at http://whqlibdoc.who. int/publications/2009/9789241597906-eng.pdf. Accessed August 30, 2009
    • (2009) WHO Guidelines on Hand Hygiene in Health Care
  • 3
    • 57749086134 scopus 로고    scopus 로고
    • Outbreak of multidrug-resistant Pseudomonas aerugi-nosa colonization and infection secondary to imperfect intensive care unit room design
    • Hota S, Hirji Z, Stockton K, et al: Outbreak of multidrug-resistant Pseudomonas aerugi-nosa colonization and infection secondary to imperfect intensive care unit room design. Infect Control Hosp Epidemiol 2009; 30: 25-33
    • (2009) Infect Control Hosp Epidemiol , vol.30 , pp. 25-33
    • Hota, S.1    Hirji, Z.2    Stockton, K.3
  • 4
    • 33750589204 scopus 로고    scopus 로고
    • A decade of adult intensive care unit design: A study of the physical design features of the best-practice examples
    • Rashid M: A decade of adult intensive care unit design: A study of the physical design features of the best-practice examples. Crit Care Nurs Q 2006; 29:282-311
    • (2006) Crit Care Nurs Q , vol.29 , pp. 282-311
    • Rashid, M.1
  • 5
    • 77953286378 scopus 로고    scopus 로고
    • Design of Australasian intensive care units: Time for change or time for more research?
    • Mar
    • Cheung W: Design of Australasian intensive care units: Time for change or time for more research? Crit Care Resusc 2008 Mar; 10: 1-70.
    • (2008) Crit Care Resusc , vol.10 , pp. 1-70
    • Cheung, W.1
  • 6
    • 0003413171 scopus 로고    scopus 로고
    • Kohn LT, Corrigan JM, Donaldson MS (Eds) Washington, DC, National Academy Press Available at Accessed August 30, 2009
    • Kohn LT, Corrigan JM, Donaldson MS (Eds): To Err Is Human: Building a Safer Health System. Washington, DC, National Academy Press, 2000. Available at http://www.nap.edu/openbook.php?isbn=0309068371. Accessed August 30, 2009
    • (2000) To Err Is Human: Building A Safer Health System
  • 7
    • 62549145508 scopus 로고    scopus 로고
    • AHRQ AHRQ Publication No. 07-0076-1. Rockville, MD, Agency for Healthcare Research and Quality Available at Accessed August 30, 2009
    • AHRQ: Transforming Hospitals: Designing for safety and quality. AHRQ Publication No. 07-0076-1. Rockville, MD, Agency for Healthcare Research and Quality, 2007. Available at http://www.ahrq.gov/qual/transform.htm. Accessed August 30, 2009
    • (2007) Transforming Hospitals: Designing for Safety and Quality
  • 8
    • 0036224420 scopus 로고    scopus 로고
    • Organizational and environmental factors that affect worker health and safety and patient outcomes
    • Lundstrom T, Pugliese G, Bartley J, et al: Organizational and environmental factors that affect worker health and safety and patient outcomes. Am J Infect Control 2002; 30:93-106
    • (2002) Am J Infect Control , vol.30 , pp. 93-106
    • Lundstrom, T.1    Pugliese, G.2    Bartley, J.3
  • 9
    • 62449314785 scopus 로고    scopus 로고
    • Impact of performance obstacles on intensive care nurses' workload, perceived quality and safety of care, and quality of working life
    • Gurses AP, Carayon P, Wall M: Impact of performance obstacles on intensive care nurses' workload, perceived quality and safety of care, and quality of working life. Health Serv Res 2009; 44:422-443
    • (2009) Health Serv Res , vol.44 , pp. 422-443
    • Gurses, A.P.1    Carayon, P.2    Wall, M.3
  • 10
    • 0033735347 scopus 로고    scopus 로고
    • ICU bedside environment: A nursing perspective
    • Jastremski CA: ICU bedside environment: A nursing perspective. Crit Care Clin 2000; 16: 723-734
    • (2000) Crit Care Clin , vol.16 , pp. 723-734
    • Jastremski, C.A.1
  • 11
    • 77954906627 scopus 로고    scopus 로고
    • Beyond the universal patient room
    • Vendome Publish Available at [Search on Scott Rawlings]. Accessed August 30, 2009
    • Rawlings S, White D: Beyond the universal patient room. Healthcare Building Ideas. Vendome Publish, 2005 (5). Available at http://www. healthcarebuildingideas.com/ME2/Default asp [Search on Scott Rawlings]. Accessed August 30, 2009
    • (2005) Healthcare Building Ideas , Issue.5
    • Rawlings, S.1    White, D.2
  • 12
    • 1842539567 scopus 로고    scopus 로고
    • Effects of acuity-adaptable rooms on flow of patients and delivery of care
    • Hendrich AL, Fay J, Sorrells AK: Effects of acuity-adaptable rooms on flow of patients and delivery of care. Am J Crit Care 2004; 13:35-45
    • (2004) Am J Crit Care , vol.13 , pp. 35-45
    • Hendrich, A.L.1    Fay, J.2    Sorrells, A.K.3
  • 13
    • 0030863031 scopus 로고    scopus 로고
    • Patient transport from intensive care increases the risk of developing ventilator-associated pneumonia
    • Kollef MI, Von Harz B, Prentice D, et al: Patient transport from intensive care increases the risk of developing ventilator-associated pneumonia. Chest 1997; 112: 765-773
    • (1997) Chest , vol.112 , pp. 765-773
    • Kollef, M.I.1    Von Harz, B.2    Prentice, D.3
  • 14
    • 33846430528 scopus 로고    scopus 로고
    • Clinical practice guidelines for support of the family in the patient-centered intensive care unit: American College of Critical Care Medicine Task Force, 2004-2005
    • Davidson JE, Powers K, Hedayat KM, et al: Clinical practice guidelines for support of the family in the patient-centered intensive care unit: American College of Critical Care Medicine Task Force 2004-2005. Crit Care Med 2007; 35:605-622
    • (2007) Crit Care Med , vol.35 , pp. 605-622
    • Davidson, J.E.1    Powers, K.2    Hedayat, K.M.3
  • 15
    • 0038294773 scopus 로고    scopus 로고
    • Available at Accessed January, 31 2010
    • The Joint Commission: National Patient Safety Goals. Available at http://www.joint commission.org/patientsafety/nationalpatient safetygoals/. Accessed January 31, 2010
    • National Patient Safety Goals
  • 16
    • 77954890225 scopus 로고    scopus 로고
    • Proceed with caution
    • (Feb). Available at Accessed February 10, 2009
    • Carpenter D, Hoppszallern S: Proceed with caution. Health Facilities Management 2009 (Feb). Available at http://hfmmagazine.com/. Accessed February 10, 2009
    • (2009) Health Facilities Management
    • Carpenter, D.1    Hoppszallern, S.2
  • 17
    • 0010320258 scopus 로고    scopus 로고
    • CDC NIOSH Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health Publication No. 139, May Available at Accessed August 30, 2009
    • CDC NIOSH: Guidance for protecting building environments from airborne chemical, biological, or radiological attacks. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health Publication No. 139, May, 2002. Available at http://www.cdc.gov/niosh/docs/2002-139/. Accessed August 30, 2009
    • (2002) Guidance for Protecting Building Environments from Airborne Chemical, Biological, or Radiological Attacks
  • 18
    • 0012960614 scopus 로고    scopus 로고
    • U.S. Army Corps of Engineers (USACE) TI 853-01. U.S. Army Corps of Engineers Engineering and Construction Division Directorate of Military Programs, Washington, DC (Oct). Available at Accessed August 30, 2009
    • U.S. Army Corps of Engineers (USACE): Protecting buildings and their occupants from airborne hazards (draft). TI 853-01. U.S. Army Corps of Engineers Engineering and Construction Division Directorate of Military Programs, Washington, DC, 2001 (Oct). Available at http://www.nmhc.org/Content/ServeFile. cfm?FileID=2413. Accessed August 30, 2009
    • (2001) Protecting Buildings and Their Occupants from Airborne Hazards (Draft)
  • 19
    • 0034572474 scopus 로고    scopus 로고
    • Burden if Aspergillosis-related hospitalizations in the United States
    • Dasbach EJ, Davies GM, Teutsch SM: Burden if Aspergillosis-related hospitalizations in the United States. Clin Infect Dis 2000; 31: 1524-1528
    • (2000) Clin Infect Dis , vol.31 , pp. 1524-1528
    • Dasbach, E.J.1    Davies, G.M.2    Teutsch, S.M.3
  • 20
    • 0035109799 scopus 로고    scopus 로고
    • Aspergillosis case-fatality rate: Systematic review of the literature
    • Lin S-J, Schranz J, Teutsch SM: Aspergillosis case-fatality rate: Systematic review of the literature. Clin Infect Dis 2001; 32:358-366
    • (2001) Clin Infect Dis , vol.32 , pp. 358-366
    • Lin, S.-J.1    Schranz, J.2    Teutsch, S.M.3
  • 21
    • 33744519313 scopus 로고    scopus 로고
    • Nosocomial aspergillosis in outbreak settings
    • Vonberg RP, Gastmeier P: Nosocomial aspergillosis in outbreak settings. JHosp Infect 2006; 63:246-254
    • (2006) JHosp Infect , vol.63 , pp. 246-254
    • Vonberg, R.P.1    Gastmeier, P.2
  • 22
    • 66949118944 scopus 로고    scopus 로고
    • Epidemiology and outcomes of candidemia in 2019 patients: Data from the prospective antifungal therapy alliance registry
    • Horn DL, Neofytos D, Anaissie EJ, et al: Epidemiology and outcomes of candidemia in 2019 patients: Data from the prospective antifungal therapy alliance registry. Clin Infect Dis 2009; 48:1695-1703
    • (2009) Clin Infect Dis , vol.48 , pp. 1695-1703
    • Horn, D.L.1    Neofytos, D.2    Anaissie, E.J.3
  • 23
    • 0037087045 scopus 로고    scopus 로고
    • Pathogenic Aspergillus species recovered from a hospital water system: A 3-year prospective study
    • Anaissie EJ, Stratton SL, Dignani MC, et al: Pathogenic Aspergillus species recovered from a hospital water system: A 3-year prospective study. Clin Infect Dis 2002; 34: e780-e789
    • (2002) Clin Infect Dis , vol.34
    • Anaissie, E.J.1    Stratton, S.L.2    Dignani, M.C.3
  • 24
    • 0035576922 scopus 로고    scopus 로고
    • Fusa-riosis associated with pathogenic Fusarium species colonization of a hospital water system: A new paradigm for the epidemiology of opportunistic mold infections
    • Anaissie EJ, Kuchar RT, Rex JH, et al: Fusa-riosis associated with pathogenic Fusarium species colonization of a hospital water system: A new paradigm for the epidemiology of opportunistic mold infections. Clin Infect Dis 2001; 33:1871-1878
    • (2001) Clin Infect Dis , vol.33 , pp. 1871-1878
    • Anaissie, E.J.1    Kuchar, R.T.2    Rex, J.H.3
  • 25
    • 85047690327 scopus 로고
    • Association of legionnaires' disease with construction: Contamination of potable water?
    • Mermel LA, Josephson SL, Giorgio CH, et al: Association of legionnaires' disease with construction: Contamination of potable water? Infect Control Hosp Epidemiol 1995; 16: 76-81
    • (1995) Infect Control Hosp Epidemiol , vol.16 , pp. 76-81
    • Mermel, L.A.1    Josephson, S.L.2    Giorgio, C.H.3
  • 26
    • 0036314980 scopus 로고    scopus 로고
    • Legionella and Legionnaires disease: 25 years of investigation
    • Fields BS, Benson RF, Besser RE: Legionella and Legionnaires disease: 25 years of investigation. Clin Microbiol Rev 2002; 15: 506-526
    • (2002) Clin Microbiol Rev , vol.15 , pp. 506-526
    • Fields, B.S.1    Benson, R.F.2    Besser, R.E.3
  • 28
    • 0028491986 scopus 로고
    • Nosocomial legionellosis associated with aspiration of nasogastric feedings diluted in tap water
    • Venezia RA, Agresta MD, Hanley EM, et al: Nosocomial legionellosis associated with aspiration of nasogastric feedings diluted in tap water. Infect Control Hosp Epidemiol 1994; 15:529-533
    • (1994) Infect Control Hosp Epidemiol , vol.15 , pp. 529-533
    • Venezia, R.A.1    Agresta, M.D.2    Hanley, E.M.3
  • 29
    • 0025381588 scopus 로고
    • Disinfection of water distribution systems for Legionella: A review of application procedures and methodologies
    • Muraca P, Yu VL, Goetz A: Disinfection of water distribution systems for Legionella: A review of application procedures and methodologies. Infect Control Hosp Epidemiol 1990; 11:79-88
    • (1990) Infect Control Hosp Epidemiol , vol.11 , pp. 79-88
    • Muraca, P.1    Yu, V.L.2    Goetz, A.3
  • 30
    • 34548348167 scopus 로고    scopus 로고
    • Active surveillance of Legionnaires disease during a prospective observational study of community and hospital-acquired pneumonia
    • Leoni E, Sacchetti R, Aporti M, et al: Active surveillance of Legionnaires disease during a prospective observational study of community and hospital-acquired pneumonia. Infect Control Hosp Epidemiol 2007; 28:1085-1088
    • (2007) Infect Control Hosp Epidemiol , vol.28 , pp. 1085-1088
    • Leoni, E.1    Sacchetti, R.2    Aporti, M.3
  • 31
    • 34447317832 scopus 로고    scopus 로고
    • Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: A national surveillance study with clinical correlations
    • Stout JE, Muder RR, Mietzner S, et al: Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: A national surveillance study with clinical correlations. Infect Control Hosp Epidemiol 2007; 28:818-824
    • (2007) Infect Control Hosp Epidemiol , vol.28 , pp. 818-824
    • Stout, J.E.1    Muder, R.R.2    Mietzner, S.3
  • 33
    • 0003610516 scopus 로고    scopus 로고
    • Facility Guidelines Institute. American Institute of Architects/Academy of Architecture for Health Washington, DC, The American Institute of Architects Press Available at Accessed August 30, 2009
    • Facility Guidelines Institute: American Institute of Architects/Academy of Architecture for Health. 2006 Guidelines for Design and Construction of Healthcare Facilities. Washington, DC, The American Institute of Architects Press, 2006. Available at http://www. fgiguidelines.org/guidelines.html. Accessed August 30, 2009
    • (2006) 2006 Guidelines for Design and Construction of Healthcare Facilities
  • 34
    • 77954922099 scopus 로고    scopus 로고
    • Chicago, American Society of Healthcare Engineering of the American Hospital Association. Available at Accessed January 31, 2010
    • -2010 Edition of the Guidelines for Design and Construction of Health Care Facilities. Chicago, American Society of Healthcare Engineering of the American Hospital Association. Available at http://www.fgiguidelines. org. Accessed January 31, 2010
    • 2010 Edition of the Guidelines for Design and Construction of Health Care Facilities
  • 35
    • 67651047404 scopus 로고    scopus 로고
    • A review of the research literature on evidence-based healthcare design
    • Ulrich RS, Zimring C, Zhu CM, et al: A review of the research literature on evidence-based healthcare design. Health Environ Res Des 2008; 1:61-125
    • (2008) Health Environ Res des , vol.1 , pp. 61-125
    • Ulrich, R.S.1    Zimring, C.2    Zhu, C.M.3
  • 36
    • 0036675294 scopus 로고    scopus 로고
    • New vistas. Evidence-based design projects look into the links between a facility's environment and its care
    • Bilchik GS: New vistas. Evidence-based design projects look into the links between a facility's environment and its care. Health Facil Manage 2002; 15:19-24
    • (2002) Health Facil Manage , vol.15 , pp. 19-24
    • Bilchik, G.S.1
  • 37
    • 0034609116 scopus 로고    scopus 로고
    • Putting patients first: Integrating hospital design and care
    • Martin C: Putting patients first: Integrating hospital design and care. Lancet 2000; 356: 518
    • (2000) Lancet , vol.356 , pp. 518
    • Martin, C.1
  • 38
    • 33750153170 scopus 로고    scopus 로고
    • Creating a culture of patient safety through innovative hospital design
    • Available at Accessed August 30, 2009
    • Reiling J: Creating a culture of patient safety through innovative hospital design. In: Advances in Patient Safety: From Research to Implementation. Available at http://www. ncbi.nlm.nih.gov/books/bv.fcgi?rid = aps. section.3446. Accessed August 30, 2009
    • Advances in Patient Safety: From Research to Implementation
    • Reiling, J.1
  • 39
    • 0035042412 scopus 로고    scopus 로고
    • Engineering infection control through facility design
    • Noskin GA, Peterson LR: Engineering infection control through facility design. Emerg Infect Dis 2001; 7:354-357
    • (2001) Emerg Infect Dis , vol.7 , pp. 354-357
    • Noskin, G.A.1    Peterson, L.R.2
  • 40
    • 0035191123 scopus 로고    scopus 로고
    • Infection control considerations in critical care unit design and construction: A systematic risk assessment
    • Bartley J, Bjerke NB: Infection control considerations in critical care unit design and construction: A systematic risk assessment. Crit Care Nurs Q 2001; 24:43-58
    • (2001) Crit Care Nurs Q , vol.24 , pp. 43-58
    • Bartley, J.1    Bjerke, N.B.2
  • 43
    • 50449096656 scopus 로고    scopus 로고
    • Single-Patient rooms for safe patient-centered hospitals
    • Detsky ME, Etchells E: Single-Patient rooms for safe patient-centered hospitals. JAMA 2008; 300:954-956
    • (2008) JAMA , vol.300 , pp. 954-956
    • Detsky, M.E.1    Etchells, E.2
  • 44
    • 34247559825 scopus 로고    scopus 로고
    • Single rooms may help to prevent nosocomial bloodstream infection and cross-transmission of methicillin-resistant Staphylococcus aureus in intensive care units
    • Bracco D, Dubois MJ, Bouali R, et al: Single rooms may help to prevent nosocomial bloodstream infection and cross-transmission of methicillin-resistant Staphylococcus aureus in intensive care units. Intensive Care Med 2007; 33:836-840
    • (2007) Intensive Care Med , vol.33 , pp. 836-840
    • Bracco, D.1    Dubois, M.J.2    Bouali, R.3
  • 45
    • 13444265933 scopus 로고    scopus 로고
    • Transfer of vancomycin-resistant enterococci via health care worker hands
    • Duckro AN: Transfer of vancomycin-resistant enterococci via health care worker hands. Arch Intern Med 2005; 165:302-307
    • (2005) Arch Intern Med , vol.165 , pp. 302-307
    • Duckro, A.N.1
  • 46
    • 33644881368 scopus 로고    scopus 로고
    • A study of the relationship between environmental contamination with methicillin-resistant Staphylococcus aureus (MRSA) and patients' acquisition of MRSA
    • Hardy KJ, Oppenheim BA, Gossain S, et al: A study of the relationship between environmental contamination with methicillin-resistant Staphylococcus aureus (MRSA) and patients' acquisition of MRSA. Infect Control Hosp Epidemiol 2006; 27:127-132
    • (2006) Infect Control Hosp Epidemiol , vol.27 , pp. 127-132
    • Hardy, K.J.1    Oppenheim, B.A.2    Gossain, S.3
  • 47
    • 0036172982 scopus 로고    scopus 로고
    • Sensor-operated faucets: A possible source of noso-comial infection?
    • Assadian O, El-Madani L, et al: Sensor-operated faucets: A possible source of noso-comial infection? Infect Control Hosp Epidemiol 2002; 23:44-46
    • (2002) Infect Control Hosp Epidemiol , vol.23 , pp. 44-46
    • Assadian, O.1    El-Madani, L.2
  • 48
    • 23044438375 scopus 로고    scopus 로고
    • The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet
    • Barker J, Jones MV: The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet. J Appl Microbiol 2005; 99:339-347
    • (2005) J Appl Microbiol , vol.99 , pp. 339-347
    • Barker, J.1    Jones, M.V.2
  • 49
    • 0033976370 scopus 로고    scopus 로고
    • Survival of enterococci and staphylococci on hospital fabrics and plastic
    • Neely AC, Maley MP: Survival of enterococci and staphylococci on hospital fabrics and plastic. J Clin Microbiol 2000; 38:724-726
    • (2000) J Clin Microbiol , vol.38 , pp. 724-726
    • Neely, A.C.1    Maley, M.P.2
  • 51
    • 0020059047 scopus 로고
    • Carpeting in hospitals: An epidemiological evaluation
    • Anderson RL, Mackel DC, Stoler BS, et al: Carpeting in hospitals: An epidemiological evaluation. J Clin Microbiol 1982; 15:408-415
    • (1982) J Clin Microbiol , vol.15 , pp. 408-415
    • Anderson, R.L.1    MacKel, D.C.2    Stoler, B.S.3
  • 53
    • 36549040975 scopus 로고    scopus 로고
    • Recommended standards for the newborn ICU
    • White RD: Recommended standards for the newborn ICU. J Perinatol 2007; 7(Suppl 2): S4-S19
    • (2007) J Perinatol , vol.7 , Issue.SUPPL. 2
    • White, R.D.1
  • 54
    • 0025878237 scopus 로고
    • Key considerations in emergency and trauma unit design
    • Barber JM: Key considerations in emergency and trauma unit design. Crit Care Nurs Q 1991; 14:71-82
    • (1991) Crit Care Nurs Q , vol.14 , pp. 71-82
    • Barber, J.M.1
  • 55
    • 0034009868 scopus 로고    scopus 로고
    • APIC State-of-the-art-report: The role of infection control during construction in health care facilities
    • Bartley JM: APIC State-of-the-art-report: the role of infection control during construction in health care facilities. Am J Infect Control 2000; 28:156-159
    • (2000) Am J Infect Control , vol.28 , pp. 156-159
    • Bartley, J.M.1
  • 56
    • 77954941000 scopus 로고    scopus 로고
    • IAQ. Minneapolis, MN, Sept. 16-17 2002. Available at Accessed August 30, 2009
    • IAQ. Minneapolis, MN, Sept. 16-17 2002. Available at http://www.dehs.umn. edu/iaq. htm. Accessed August 30, 2009
  • 57
    • 77954911686 scopus 로고    scopus 로고
    • May Available at Accessed August 30, 2009
    • U.S. Environmental Protection Agency: Label fact sheet: EPA registers copper-containing alloy products. May 2008. Available at http://www.epa.gov/ pesticides/factsheets/copper-alloy-products.htm. Accessed August 30, 2009
    • (2008) Label Fact Sheet: EPA Registers Copper-containing Alloy Products
  • 58
    • 33744547266 scopus 로고    scopus 로고
    • Potential use of copper surfaces to reduce survival of epidemic methicillin-resistant S. aureus in the healthcare environment
    • Noyce JO, Michels H, Keevil CW: Potential use of copper surfaces to reduce survival of epidemic methicillin-resistant S. aureus in the healthcare environment. J Hosp Infect 2006; 63:289-297
    • (2006) J Hosp Infect , vol.63 , pp. 289-297
    • Noyce, J.O.1    Michels, H.2    Keevil, C.W.3
  • 59
    • 35648987070 scopus 로고    scopus 로고
    • Potential use of copper as a hygienic surface; Problems associated with cumulative soiling and cleaning
    • Airey P, Verran J: Potential use of copper as a hygienic surface; problems associated with cumulative soiling and cleaning. J Hosp Infect 2007; 67:271-277
    • (2007) J Hosp Infect , vol.67 , pp. 271-277
    • Airey, P.1    Verran, J.2
  • 61
    • 77954914907 scopus 로고    scopus 로고
    • CDC NIOSH Department of Health and Human Services, Centers for Disease Control and Prevention, and National Institute for Occupational Safety and Health Publication No. 2009-105. March 2009. Available at Accessed August 30, 2009
    • CDC NIOSH: Environmental control for tuberculosis: Basic upper-room ultraviolet ger-micidal irradiation guidelines for healthcare settings, 2009. Department of Health and Human Services, Centers for Disease Control and Prevention, and National Institute for Occupational Safety and Health Publication No. 2009-105. March 2009. Available at http://www.cdc.gov/niosh/ docs/2009-105/pdfs/2009-105.pdf. Accessed August 30, 2009
    • Environmental Control for Tuberculosis: Basic Upper-room Ultraviolet Ger-micidal Irradiation Guidelines for Healthcare Settings 2009
  • 62
    • 77954891227 scopus 로고    scopus 로고
    • A methodology for minimizing risk from airborne organisms in hospital isolation room
    • Available at Accessed August 30, 2009
    • Memarzadeh F, Jiang J: A methodology for minimizing risk from airborne organisms in hospital isolation room. ASHRAE Trans 2002; 106:731-737. Available at http://orf.od.nih.gov/PoliciesAndGuidelines/Bioenvironmental. Accessed August 30, 2009
    • (2002) ASHRAE Trans , vol.106 , pp. 731-737
    • Memarzadeh, F.1    Jiang, J.2
  • 63
    • 33749071586 scopus 로고    scopus 로고
    • An evaluation of patient area cleaning in 36 hospitals using a novel targeting methodology
    • Carling PC, Briggs J, Hylander, et al: An evaluation of patient area cleaning in 36 hospitals using a novel targeting methodology. Am J Infect Control 2006; 34:513-519
    • (2006) Am J Infect Control , vol.34 , pp. 513-519
    • Carling, P.C.1    Hylander, B.J.2
  • 64
    • 77954929873 scopus 로고    scopus 로고
    • Minnesota Department of Health Available at Accessed February 10, 2010
    • Minnesota Department of Health: Isolation capacity training resources. Available at http://www.health.state.mn.us/oep/training/bhpp/isolation.html. Accessed February 10, 2010
    • Isolation Capacity Training Resources
  • 65
    • 33644873206 scopus 로고    scopus 로고
    • Guidelines for Preventing the Transmission of Mycobacterium Tuberculosis in Health-Care Settings 2005
    • Available at Errata, 09/25/2006. Available at http://www.cdc.gov/tb/ publications/reportsarticles/mmwr/Errata09-25-06.pdf. Accessed August 30, 2009
    • CDC: Guidelines for Preventing the Transmission of Mycobacterium tuberculosis in Health-Care Settings 2005. MMWR 2005;54: 1-141. Available at http://www.cdc.gov/mmwr/pdf/rr/rr5417.pdf. Errata, 09/25/2006. Available at http://www.cdc.gov/tb/publications/reportsarticles/mmwr/Errata09-25-06.pdf. Accessed August 30, 2009
    • (2005) MMWR , vol.54 , pp. 1-141
  • 66
    • 1642525257 scopus 로고    scopus 로고
    • Guidelines for preventing health-care-associated pneumonia 2003. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee
    • Available at Accessed August 30, 2009
    • Tablan OC, Anderson LJ, Besser R, et al: Guidelines for preventing health-care-associated pneumonia, 2003. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR 2004; 53:1-36. Available at http://www.cdc.gov/ncidod/dhqp/pdf/guidelines/CDCpneumo-guidelines. pdf. Accessed August 30, 2009
    • (2004) MMWR , vol.53 , pp. 1-36
    • Tablan, O.C.1    Anderson, L.J.2    Besser, R.3
  • 67
    • 34250195734 scopus 로고    scopus 로고
    • A performance assessment of airborne infection isolation rooms
    • Saravia SA, Raynor PC, Streifel AJ: A performance assessment of airborne infection isolation rooms. Am J Infect Control 2007; 35: 324-331
    • (2007) Am J Infect Control , vol.35 , pp. 324-331
    • Saravia, S.A.1    Raynor, P.C.2    Streifel, A.J.3
  • 68
    • 0035149576 scopus 로고    scopus 로고
    • Room pressure. A critical parameter for special ventilation rooms
    • Rice N, Streifel A, Veseley D: Room pressure. A critical parameter for special ventilation rooms. Infect Control Hosp Epidemiol 2001; 22:19-23
    • (2001) Infect Control Hosp Epidemiol , vol.22 , pp. 19-23
    • Rice, N.1    Streifel, A.2    Veseley, D.3
  • 69
    • 77954919475 scopus 로고    scopus 로고
    • Air leakage analysis of special ventilation rooms
    • Available at Accessed June 4, 2010
    • Geeslin A, Streifel A, Nelson G. Air leakage analysis of special ventilation rooms. ASHRAE Transactions. 2008; 114:447-452. Available at http://www.thefreelibrary.com/Air+leakage+ analysis+of+ special+ventilation+hospital+ rooms.-a0201378225. Accessed June 4, 2010
    • (2008) ASHRAE Transactions. , vol.114 , pp. 447-452
    • Geeslin, A.1    Streifel, A.2    Nelson, G.3
  • 70
    • 0034146803 scopus 로고    scopus 로고
    • Identification of factors that disrupt negative air pressurization of respiratory isolation rooms
    • Pavelchak N, DePersis RP, London M, et al: Identification of factors that disrupt negative air pressurization of respiratory isolation rooms. Infect Control Hosp Epidemiol 2000; 21:191-195
    • (2000) Infect Control Hosp Epidemiol , vol.21 , pp. 191-195
    • Pavelchak, N.1    Depersis, R.P.2    London, M.3
  • 71
    • 77954890918 scopus 로고    scopus 로고
    • Frances J. Curry National Tuberculosis Center. Available at Accessed August 30, 2009
    • Tuberculosis infection control: A practical manual for preventing TB. Frances J. Curry National Tuberculosis Center. Available at http://www. nationaltbcenter.edu/TB-IC/. Accessed August 30, 2009
    • Tuberculosis Infection Control: A Practical Manual for Preventing TB
  • 72
    • 0027737707 scopus 로고
    • A ventilation-filtration unit for respiratory isolation
    • Marier RL, Nelson T: A ventilation-filtration unit for respiratory isolation. Infect Control Hosp Epidemiol 1993; 14:700-705
    • (1993) Infect Control Hosp Epidemiol , vol.14 , pp. 700-705
    • Marier, R.L.1    Nelson, T.2
  • 73
    • 34548509207 scopus 로고    scopus 로고
    • Ten-year air sample analysis of Aspergillus prevalence in a university hospital
    • Falvey DG, Streifel AJ: Ten-year air sample analysis of Aspergillus prevalence in a university hospital. J Hosp Infect 2007; 67:35-41
    • (2007) J Hosp Infect , vol.67 , pp. 35-41
    • Falvey, D.G.1    Streifel, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.