Technical evaluation of a digital breast tomosynthesis system

Author keywords

[No Author keywords available]

Indexed keywords

AIR KERMA; DETECTIVE QUANTUM EFFICIENCY; DETECTOR GAIN; DETECTOR PERFORMANCE; DETECTOR RESPONSE; DIGITAL BREAST TOMOSYNTHESIS; FOCAL SPOT SIZE; MODULATION TRANSFER FUNCTION; NORMALIZED NOISE POWER SPECTRUM; PROJECTION IMAGE; QUANTITATIVE ASSESSMENTS; QUANTUM LIMITED; TECHNICAL EVALUATION; TOMOGRAPHIC;

EID: 77954654610     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-13666-5_47     Document Type: Conference Paper
Times cited : (7)

References (8)
  • 2
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • Samei, E., Flynn, M.J., Riemann, D.A.: A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Med. Phys. 25, 102-113 (1998)
    • (1998) Med. Phys. , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Riemann, D.A.3
  • 5
    • 42949103956 scopus 로고    scopus 로고
    • Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system
    • Zhao, B., Zhao, W.: Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system. Med. Phys. 35, 1978-1987 (2008)
    • (2008) Med. Phys. , vol.35 , pp. 1978-1987
    • Zhao, B.1    Zhao, W.2
  • 6
    • 66849126255 scopus 로고    scopus 로고
    • The Effect of Lag on Image Quality for a Digital Breast Tomosynthesis System
    • Mainprize, J.G., Wang, X., Yaffe, M.J.: The Effect of Lag on Image Quality for a Digital Breast Tomosynthesis System. In: Proc. of SPIE, vol. 7258, 72580R1-72580R12 (2009)
    • (2009) Proc. of SPIE , vol.7258
    • Mainprize, J.G.1    Wang, X.2    Yaffe, M.J.3
  • 7
    • 58149136863 scopus 로고    scopus 로고
    • Experimental validation of a three-dimensional linear system model for breast tomosynthesis
    • Zhao, B., Zhou, J., Hu, Y.-H., Mertelmeier, T., Ludwig, J., Zhao, W.: Experimental validation of a three-dimensional linear system model for breast tomosynthesis. Med. Phys. 36, 240-251 (2008)
    • (2008) Med. Phys. , vol.36 , pp. 240-251
    • Zhao, B.1    Zhou, J.2    Hu, Y.-H.3    Mertelmeier, T.4    Ludwig, J.5    Zhao, W.6
  • 8
    • 56749159109 scopus 로고    scopus 로고
    • Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT
    • Tward, D.J., Siewerdsen, J.H.: Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT. Med. Phys. 35, 5510-5529 (2008)
    • (2008) Med. Phys. , vol.35 , pp. 5510-5529
    • Tward, D.J.1    Siewerdsen, J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.