Volumn 35, Issue 12, 2008, Pages 5510-5529

Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT

Author keywords

3D imaging; Computed tomography; Cone beam CT; Detective quantum efficiency; DQE; Flat panel detector; Imaging performance; Imaging task; NEQ; Noise equivalent quanta; Noise power spectrum; NPS

Indexed keywords

3D MODELING; EFFICIENCY; IMAGE RECONSTRUCTION; IMAGING SYSTEMS; NEPTUNIUM; POWER SPECTRUM; QUANTUM EFFICIENCY; SYSTEMS ANALYSIS; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 56749159109     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3002414     Document Type: Article
Times cited : (123)

References (48)
  • 1
    • 85027233939 scopus 로고    scopus 로고
    • ICRU Report 54. Medical Imaging-The Assessment of Image Quality (Bethesda, MD, International Commission on Radiation Units and Measurements).
    • ICRU Report 54. Medical Imaging-The Assessment of Image Quality (Bethesda, MD, International Commission on Radiation Units and Measurements) (1996).
    • (1996)
  • 2
    • 0031019011 scopus 로고    scopus 로고
    • Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology
    • J. H. Siewerdsen, L. E. Antonuk, Y. El Mohri, J. Yorkston, W. Huang, J. M. Boudry, and I. A. Cunningham, " Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology.," Med. Phys. 24 (1), 71-89 (1997).
    • (1997) Med. Phys. , vol.24 , Issue.1 , pp. 71-89
    • Siewerdsen, J.H.1    Antonuk, L.E.2    El Mohri, Y.3    Yorkston, J.4    Huang, W.5    Boudry, J.M.6    Cunningham, I.A.7
  • 3
    • 0031805838 scopus 로고    scopus 로고
    • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology
    • J. H. Siewerdsen, L. E. Antonuk, Y. El Mohri, J. Yorkston, W. Huang, and I. A. Cunningham, " Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.," Med. Phys. 25 (5), 614-628 (1998).
    • (1998) Med. Phys. , vol.25 , Issue.5 , pp. 614-628
    • Siewerdsen, J.H.1    Antonuk, L.E.2    El Mohri, Y.3    Yorkston, J.4    Huang, W.5    Cunningham, I.A.6
  • 4
    • 0031439126 scopus 로고    scopus 로고
    • Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency
    • W. Zhao and J. A. Rowlands, " Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency.," Med. Phys. 24 (12), 1819-1833 (1997).
    • (1997) Med. Phys. , vol.24 , Issue.12 , pp. 1819-1833
    • Zhao, W.1    Rowlands, J.A.2
  • 5
    • 0034768121 scopus 로고    scopus 로고
    • Effects of characteristic x-rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors
    • W. Zhao, W. G. Ji, and J. A. Rowlands, " Effects of characteristic x-rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors.," Med. Phys. 28 (10), 2039-2049 (2001).
    • (2001) Med. Phys. , vol.28 , Issue.10 , pp. 2039-2049
    • Zhao, W.1    Ji, W.G.2    Rowlands, J.A.3
  • 7
    • 2442694110 scopus 로고    scopus 로고
    • Solid-state fluoroscopic imager for high-resolution angiography: Parallel-cascaded linear systems analysis
    • S. Vedantham, A. Karellas, and S. Suryanarayanan, " Solid-state fluoroscopic imager for high-resolution angiography: Parallel-cascaded linear systems analysis.," Med. Phys. 31 (5), 1258-1268 (2004).
    • (2004) Med. Phys. , vol.31 , Issue.5 , pp. 1258-1268
    • Vedantham, S.1    Karellas, A.2    Suryanarayanan, S.3
  • 8
    • 0344393789 scopus 로고    scopus 로고
    • Micro-angiography for neuro-vascular imaging. II. Cascade model analysis
    • A. Ganguly, S. Rudin, D. R. Bednarek, and K. R. Hoffmann, " Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.," Med. Phys. 30 (11), 3029-3039 (2003).
    • (2003) Med. Phys. , vol.30 , Issue.11 , pp. 3029-3039
    • Ganguly, A.1    Rudin, S.2    Bednarek, D.R.3    Hoffmann, K.R.4
  • 9
    • 0030986681 scopus 로고    scopus 로고
    • Optimal phosphor thickness for portal imaging
    • J. P. Bissonnette, I. A. Cunningham, and P. Munro, " Optimal phosphor thickness for portal imaging.," Med. Phys. 24 (6), 803-814 (1997).
    • (1997) Med. Phys. , vol.24 , Issue.6 , pp. 803-814
    • Bissonnette, J.P.1    Cunningham, I.A.2    Munro, P.3
  • 10
    • 0031004518 scopus 로고    scopus 로고
    • A quantum accounting and detective quantum efficiency analysis for video-based portal imaging
    • J. P. Bissonnette, I. A. Cunningham, D. A. Jaffray, A. Fenster, and P. Munro, " A quantum accounting and detective quantum efficiency analysis for video-based portal imaging.," Med. Phys. 24 (6), 815-826 (1997).
    • (1997) Med. Phys. , vol.24 , Issue.6 , pp. 815-826
    • Bissonnette, J.P.1    Cunningham, I.A.2    Jaffray, D.A.3    Fenster, A.4    Munro, P.5
  • 11
    • 0034121931 scopus 로고    scopus 로고
    • Characterization of a fluoroscopic imaging system for kV and MV radiography
    • D. G. Drake, D. A. Jaffray, and J. W. Wong, " Characterization of a fluoroscopic imaging system for kV and MV radiography.," Med. Phys. 27 (5), 898-905 (2000).
    • (2000) Med. Phys. , vol.27 , Issue.5 , pp. 898-905
    • Drake, D.G.1    Jaffray, D.A.2    Wong, J.W.3
  • 12
    • 0034917858 scopus 로고    scopus 로고
    • Detective quantum efficiency of a direct-detection active matrix flat panel imager at megavoltage energies
    • M. Lachaine, " Detective quantum efficiency of a direct-detection active matrix flat panel imager at megavoltage energies.," Med. Phys. 28 (7), 1364-1372 (2001).
    • (2001) Med. Phys. , vol.28 , Issue.7 , pp. 1364-1372
    • Lachaine, M.1
  • 13
    • 0017005599 scopus 로고
    • Statistical limitations in transaxial tomography
    • H. H. Barrett, S. K. Gordon, and R. S. Hershel, " Statistical limitations in transaxial tomography.," Comput. Biol. Med. 6 (4), 307-323 (1976).
    • (1976) Comput. Biol. Med. , vol.6 , Issue.4 , pp. 307-323
    • Barrett, H.H.1    Gordon, S.K.2    Hershel, R.S.3
  • 14
    • 0017800671 scopus 로고
    • The noise power spectrum in computed X-ray tomography
    • S. J. Riederer, N. J. Pelc, and D. A. Chesler, " The noise power spectrum in computed X-ray tomography.," Phys. Med. Biol. 23 (3), 446-454 (1978).
    • (1978) Phys. Med. Biol. , vol.23 , Issue.3 , pp. 446-454
    • Riederer, S.J.1    Pelc, N.J.2    Chesler, D.A.3
  • 15
    • 0018733995 scopus 로고
    • Detectability in computed tomographic images
    • K. M. Hanson, " Detectability in computed tomographic images.," Med. Phys. 6 (5), 441-451 (1979).
    • (1979) Med. Phys. , vol.6 , Issue.5 , pp. 441-451
    • Hanson, K.M.1
  • 16
    • 0018367387 scopus 로고
    • Application of information theory to the assessment of computed tomography
    • R. F. Wagner, D. G. Brown, and M. S. Pastel, " Application of information theory to the assessment of computed tomography.," Med. Phys. 6 (2), 83-94 (1979).
    • (1979) Med. Phys. , vol.6 , Issue.2 , pp. 83-94
    • Wagner, R.F.1    Brown, D.G.2    Pastel, M.S.3
  • 17
    • 0021736468 scopus 로고
    • Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function
    • K. Faulkner and B. M. Moores, " Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function.," Phys. Med. Biol. 29 (11), 1343-1352 (1984).
    • (1984) Phys. Med. Biol. , vol.29 , Issue.11 , pp. 1343-1352
    • Faulkner, K.1    Moores, B.M.2
  • 18
    • 0023199089 scopus 로고
    • The noise power spectrum of CT images
    • M. F. Kijewski and P. F. Judy, " The noise power spectrum of CT images.," Phys. Med. Biol. 32 (5), 565-575 (1987).
    • (1987) Phys. Med. Biol. , vol.32 , Issue.5 , pp. 565-575
    • Kijewski, M.F.1    Judy, P.F.2
  • 19
    • 0033730497 scopus 로고    scopus 로고
    • Cone-beam CT with a flat-panel imager: Noise considerations for fully 3D computed tomography
    • J. H. Siewerdsen and D. A. Jaffray, " Cone-beam CT with a flat-panel imager: Noise considerations for fully 3D computed tomography.," Proc. SPIE 3977, 408-416 (2000).
    • (2000) Proc. SPIE , vol.3977 , pp. 408-416
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 20
    • 0036035341 scopus 로고    scopus 로고
    • Unified iso-SNR approach to task-directed imaging in flat-panel cone-beam CT
    • J. H. Siewerdsen and D. A. Jaffray, " Unified iso-SNR approach to task-directed imaging in flat-panel cone-beam CT.," Proc. SPIE 4682, 245-254 (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 245-254
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 21
    • 33646661684 scopus 로고    scopus 로고
    • Three-dimensional NEQ transfer characteristics of volume CT using direct and indirect-detection flat-panel imagers
    • J. H. Siewerdsen and D. A. Jaffray, " Three-dimensional NEQ transfer characteristics of volume CT using direct and indirect-detection flat-panel imagers.," Proc. SPIE 29 (11), 2655-2671 (2003).
    • (2003) Proc. SPIE , vol.29 , Issue.11 , pp. 2655-2671
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 22
    • 3042694904 scopus 로고    scopus 로고
    • Incorporation of task in 3D imaging performance evaluation: The impact of asymmetric NPS on detectability
    • J. H. Siewerdsen, D. J. Moseley, and D. A. Jaffray, " Incorporation of task in 3D imaging performance evaluation: The impact of asymmetric NPS on detectability.," Proc. SPIE 5368, 89-97 (2004).
    • (2004) Proc. SPIE , vol.5368 , pp. 89-97
    • Siewerdsen, J.H.1    Moseley, D.J.2    Jaffray, D.A.3
  • 23
    • 43149120917 scopus 로고    scopus 로고
    • Cascaded systems analysis of the 3D NEQ for cone-beam CT and tomosynthesis
    • D. J. Tward, J. H. Siewerdsen, R. Fahrig, and A. R. Pineda, " Cascaded systems analysis of the 3D NEQ for cone-beam CT and tomosynthesis.," Proc. SPIE 6913, 69131S (2008).
    • (2008) Proc. SPIE , vol.6913
    • Tward, D.J.1    Siewerdsen, J.H.2    Fahrig, R.3    Pineda, A.R.4
  • 24
    • 0023339134 scopus 로고
    • Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms
    • M. Rabbani, R. Shaw, and R. Van Metter, " Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms.," J. Opt. Soc. Am. A 4 (5), 895-901 (1987).
    • (1987) J. Opt. Soc. Am. a , vol.4 , Issue.5 , pp. 895-901
    • Rabbani, M.1    Shaw, R.2    Van Metter, R.3
  • 25
    • 0028215328 scopus 로고
    • A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems
    • I. A. Cunningham, M. S. Westmore, and A. Fenster, " A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems.," Med. Phys. 21 (3), 417-427 (1994).
    • (1994) Med. Phys. , vol.21 , Issue.3 , pp. 417-427
    • Cunningham, I.A.1    Westmore, M.S.2    Fenster, A.3
  • 26
    • 0034767933 scopus 로고    scopus 로고
    • Parallel cascades: New ways to describe noise transfer in medical imaging systems
    • J. Yao and I. A. Cunningham, " Parallel cascades: New ways to describe noise transfer in medical imaging systems.," Med. Phys. 28 (10), 2020-2038 (2001).
    • (2001) Med. Phys. , vol.28 , Issue.10 , pp. 2020-2038
    • Yao, J.1    Cunningham, I.A.2
  • 27
    • 43149125220 scopus 로고    scopus 로고
    • Analysis of image noise in 3D cone-beam CT: Spatial and Fourier domain approaches under conditions of varying stationarity
    • A. R. Pineda, J. H. Siewerdsen, and D. J. Tward, " Analysis of image noise in 3D cone-beam CT: Spatial and Fourier domain approaches under conditions of varying stationarity.," Proc. SPIE 6913, 69131Q-69131Q-10 (2008).
    • (2008) Proc. SPIE , vol.6913
    • Pineda, A.R.1    Siewerdsen, J.H.2    Tward, D.J.3
  • 28
    • 3042544892 scopus 로고    scopus 로고
    • Can a Fourier-based cascaded-systems analysis describe noise in complex shift-variant spatially sampled detectors?
    • I. A. Cunningham, M. Sattarivand, G. Hajdok, and J. Yao, " Can a Fourier-based cascaded-systems analysis describe noise in complex shift-variant spatially sampled detectors?," Proc. SPIE 5368, 79-88 (2004).
    • (2004) Proc. SPIE , vol.5368 , pp. 79-88
    • Cunningham, I.A.1    Sattarivand, M.2    Hajdok, G.3    Yao, J.4
  • 29
    • 0033750998 scopus 로고    scopus 로고
    • Linear response theory for detectors consisting of discrete arrays
    • M. Albert and A. D. Maidment, " Linear response theory for detectors consisting of discrete arrays.," Med. Phys. 27 (10), 2417-2434 (2000).
    • (2000) Med. Phys. , vol.27 , Issue.10 , pp. 2417-2434
    • Albert, M.1    Maidment, A.D.2
  • 30
    • 42949122453 scopus 로고    scopus 로고
    • Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    • M. J. Daly, J. H. Siewerdsen, Y. B. Cho, D. A. Jaffray, and J. C. Irish, " Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.," Med. Phys. 35 (5), 2124-2136 (2008).
    • (2008) Med. Phys. , vol.35 , Issue.5 , pp. 2124-2136
    • Daly, M.J.1    Siewerdsen, J.H.2    Cho, Y.B.3    Jaffray, D.A.4    Irish, J.C.5
  • 31
    • 33745398327 scopus 로고    scopus 로고
    • Anisotropic imaging performance in indirect x-ray imaging detectors
    • A. Badano, I. Kyprianou, and J. Sempau, " Anisotropic imaging performance in indirect x-ray imaging detectors.," Med. Phys. 33 (8), 2698-2713 (2006).
    • (2006) Med. Phys. , vol.33 , Issue.8 , pp. 2698-2713
    • Badano, A.1    Kyprianou, I.2    Sempau, J.3
  • 32
    • 0033849841 scopus 로고    scopus 로고
    • Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)
    • J. H. Siewerdsen and D. A. Jaffray, " Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).," Med. Phys. 27 (8), 1903-1914 (2000).
    • (2000) Med. Phys. , vol.27 , Issue.8 , pp. 1903-1914
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 33
    • 23844539126 scopus 로고    scopus 로고
    • Generalized DQE analysis of dual-energy imaging using flat-panel detectors
    • S. Richard, J. H. Siewerdsen, D. A. Jaffray, D. J. Moseley, and B. Bakhtiar, " Generalized DQE analysis of dual-energy imaging using flat-panel detectors.," Proc. SPIE 5745, 519-528 (2005).
    • (2005) Proc. SPIE , vol.5745 , pp. 519-528
    • Richard, S.1    Siewerdsen, J.H.2    Jaffray, D.A.3    Moseley, D.J.4    Bakhtiar, B.5
  • 34
    • 0002903033 scopus 로고    scopus 로고
    • Analyzing system performance
    • Frey G. D. and Sprawls P., eds., (Advanced Medical Publishing, Madison, WI).
    • I. A. Cunningham, " Analyzing system performance.,", Frey G. D., and, Sprawls P., eds., The Expanding Role of Medical Physics in Diagnostic Imaging (Advanced Medical Publishing, Madison, WI, 1997).
    • (1997) The Expanding Role of Medical Physics in Diagnostic Imaging
    • Cunningham, I.A.1
  • 35
    • 9244249165 scopus 로고    scopus 로고
    • Spektr: A computational tool for x-ray spectral analysis and imaging system optimization
    • J. H. Siewerdsen, A. M. Waese, D. J. Moseley, S. Richard, and D. A. Jaffray, " Spektr: A computational tool for x-ray spectral analysis and imaging system optimization.," Med. Phys. 31 (11), 3057-3067 (2004).
    • (2004) Med. Phys. , vol.31 , Issue.11 , pp. 3057-3067
    • Siewerdsen, J.H.1    Waese, A.M.2    Moseley, D.J.3    Richard, S.4    Jaffray, D.A.5
  • 38
    • 0028840692 scopus 로고
    • DQE(f) of four generations of computed radiography acquisition devices
    • J. T. Dobbins III, D. L. Ergun, L. Rutz, D. A. Hinshaw, H. Blume, and D. C. Clark, " DQE(f) of four generations of computed radiography acquisition devices.," Med. Phys. 22 (10), 1581-1593 (1995).
    • (1995) Med. Phys. , vol.22 , Issue.10 , pp. 1581-1593
    • Dobbins III, J.T.1    Ergun, D.L.2    Rutz, L.3    Hinshaw, D.A.4    Blume, H.5    Clark, D.C.6
  • 39
    • 1842865422 scopus 로고    scopus 로고
    • A framework for noise-power spectrum analysis of multidimensional images
    • J. H. Siewerdsen, I. A. Cunningham, and D. A. Jaffray, " A framework for noise-power spectrum analysis of multidimensional images.," Med. Phys. 29 (11), 2655-2671 (2002).
    • (2002) Med. Phys. , vol.29 , Issue.11 , pp. 2655-2671
    • Siewerdsen, J.H.1    Cunningham, I.A.2    Jaffray, D.A.3
  • 40
    • 35648948358 scopus 로고    scopus 로고
    • Soft-tissue detectability in cone-beam CT: Evaluation by 2AFC tests in relation to physical performance metrics
    • D. J. Tward and J. H. Siewerdsen, " Soft-tissue detectability in cone-beam CT: Evaluation by 2AFC tests in relation to physical performance metrics.," Med. Phys. 34 (11), 4459-4471 (2007).
    • (2007) Med. Phys. , vol.34 , Issue.11 , pp. 4459-4471
    • Tward, D.J.1    Siewerdsen, J.H.2
  • 41
    • 0035049369 scopus 로고    scopus 로고
    • Human observer detection experiments with mammograms and power-law noise
    • A. E. Burgess, F. L. Jacobson, and P. F. Judy, " Human observer detection experiments with mammograms and power-law noise.," Med. Phys. 28 (4), 419-437 (2001).
    • (2001) Med. Phys. , vol.28 , Issue.4 , pp. 419-437
    • Burgess, A.E.1    Jacobson, F.L.2    Judy, P.F.3
  • 42
    • 0034132171 scopus 로고    scopus 로고
    • Visual signal detection in structured backgrounds. III. Calculation of figures of merit for model observers in statistically nonstationary backgrounds
    • F. O. Bochud, C. K. Abbey, and M. P. Eckstein, " Visual signal detection in structured backgrounds. III. Calculation of figures of merit for model observers in statistically nonstationary backgrounds.," J. Opt. Soc. Am. A Opt. Image Sci. Vis 17 (2), 193-205 (2000).
    • (2000) J. Opt. Soc. Am. a Opt. Image Sci. Vis , vol.17 , Issue.2 , pp. 193-205
    • Bochud, F.O.1    Abbey, C.K.2    Eckstein, M.P.3
  • 43
    • 0032742627 scopus 로고    scopus 로고
    • On the statistical nature of mammograms
    • J. J. Heine, S. R. Deans, R. P. Velthuizen, and L. P. Clarke, " On the statistical nature of mammograms.," Med. Phys. 26 (11), 2254-2265 (1999).
    • (1999) Med. Phys. , vol.26 , Issue.11 , pp. 2254-2265
    • Heine, J.J.1    Deans, S.R.2    Velthuizen, R.P.3    Clarke, L.P.4
  • 44
    • 0036033581 scopus 로고    scopus 로고
    • Investigation of optimal KVp setting for CT mammography using a flat-panel imager
    • S. J. Glick, S. Vedantham, and A. Karellas, " Investigation of optimal KVp setting for CT mammography using a flat-panel imager.," Proc. SPIE 4682, 392-402 (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 392-402
    • Glick, S.J.1    Vedantham, S.2    Karellas, A.3
  • 45
    • 56749163609 scopus 로고    scopus 로고
    • A comparison of anotomical noise properties between breast CT and projection breast imaging
    • K. Metheany, J. M. Boone, C. K. Abbey, and N. Packard, " A comparison of anotomical noise properties between breast CT and projection breast imaging.," Med. Phys. 34 (6), 2563 (2007).
    • (2007) Med. Phys. , vol.34 , Issue.6 , pp. 2563
    • Metheany, K.1    Boone, J.M.2    Abbey, C.K.3    Packard, N.4
  • 46
    • 56749092178 scopus 로고    scopus 로고
    • Comparison of the breast tissue power spectrum for mammograms, tomosynthesis projection images, and tomosynthesis reconstruction images
    • R. M. Nishikawa, E. Engstrom, and I. Reiser, " Comparison of the breast tissue power spectrum for mammograms, tomosynthesis projection images, and tomosynthesis reconstruction images.," Annual Meeting of the Radiological Society of North America (RSNA) (2007).
    • (2007) Annual Meeting of the Radiological Society of North America (RSNA)
    • Nishikawa, R.M.1    Engstrom, E.2    Reiser, I.3
  • 47
    • 18844368046 scopus 로고
    • Detection and discrimination of known signals in inhomogenous, random backgrounds
    • H. H. Barrett, J. P. Rolland, R. F. Wagner, and K. J. Myers, " Detection and discrimination of known signals in inhomogenous, random backgrounds.," Proc. SPIE 1090, 176-182 (1989).
    • (1989) Proc. SPIE , vol.1090 , pp. 176-182
    • Barrett, H.H.1    Rolland, J.P.2    Wagner, R.F.3    Myers, K.J.4
  • 48
    • 0029299915 scopus 로고
    • Objective assessment of image quality. II. Fisher information, Fourier crosstalk, and figures of merit for task performance
    • H. H. Barrett, J. L. Denny, R. F. Wagner, and K. J. Myers, " Objective assessment of image quality. II. Fisher information, Fourier crosstalk, and figures of merit for task performance.," J. Opt. Soc. Am. A 12 (5), 834-852 (1995).
    • (1995) J. Opt. Soc. Am. a , vol.12 , Issue.5 , pp. 834-852
    • Barrett, H.H.1    Denny, J.L.2    Wagner, R.F.3    Myers, K.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.