메뉴 건너뛰기




Volumn 7258, Issue , 2009, Pages

The effect of lag on image quality for a digital breast tomosynthesis system

Author keywords

Detective quantum efficiency; Lag; Noise power spectrum; Tomosynthesis

Indexed keywords

ACQUISITION TIME; COMPUTED TOMOGRAPHY; CONE BEAM; CONSPICUITY; DETECTIVE QUANTUM EFFICIENCY; DIGITAL BREAST TOMOSYNTHESIS; DIGITAL MAMMOGRAPHY; DIGITAL MAMMOGRAPHY SYSTEM; FILTERED BACK-PROJECTION; IMAGE FORMATIONS; IMAGE NOISE; LAG; LOSS-OF-SIGNAL; MONTE CARLO SIMULATION; NOISE POWER SPECTRUM; PROJECTION IMAGE; TEMPORAL RESPONSE; TOMOSYNTHESIS; TRANSIENT EFFECT;

EID: 66849126255     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.811889     Document Type: Conference Paper
Times cited : (9)

References (22)
  • 1
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • Dobbins, J. T.,3rd, Godfrey, D. J., "Digital x-ray tomosynthesis: current state of the art and clinical potential," Phys. Med. Biol. 48(19), R65-106 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , Issue.19
    • Dobbins, J.T.1    Godfrey, D.J.2
  • 2
    • 0347625748 scopus 로고    scopus 로고
    • Tomosynthesis-based localization of radioactive seeds in prostate brachytherapy
    • Tutar, I. B., Managuli, R., Shamdasani, V., Cho, P. S., Pathak, S. D., Kim, Y., "Tomosynthesis-based localization of radioactive seeds in prostate brachytherapy," Med. Phys. 30(12), 3135-3142 (2003).
    • (2003) Med. Phys. , vol.30 , Issue.12 , pp. 3135-3142
    • Tutar, I.B.1    Managuli, R.2    Shamdasani, V.3    Cho, P.S.4    Pathak, S.D.5    Kim, Y.6
  • 3
    • 0038601699 scopus 로고    scopus 로고
    • Digital tomosynthesis-experiences with a new imaging device for the dental field
    • Ziegler, C. M., Franetzki, M., Denig, T., Muhling, J., Hassfeld, S., "Digital tomosynthesis-experiences with a new imaging device for the dental field," Clin. Oral. Investig. 7(1), 41-45 (2003).
    • (2003) Clin. Oral. Investig. , vol.7 , Issue.1 , pp. 41-45
    • Ziegler, C.M.1    Franetzki, M.2    Denig, T.3    Muhling, J.4    Hassfeld, S.5
  • 5
    • 33746617894 scopus 로고    scopus 로고
    • Lag and ghosting in a clinical flatpanel selenium digital mammography system
    • Bloomquist, A. K., Yaffe, M. J., Mawdsley, G. E., Hunter, D. M., Beideck, D. J., "Lag and ghosting in a clinical flatpanel selenium digital mammography system," Med. Phys. 33(8), 2998-3005 (2006).
    • (2006) Med. Phys. , vol.3 , Issue.8 , pp. 2998-3005
    • Bloomquist, A.K.1    Yaffe, M.J.2    Mawdsley, G.E.3    Hunter, D.M.4    Beideck, D.J.5
  • 6
    • 0036033452 scopus 로고    scopus 로고
    • Investigation of lag and ghosting in amorphous selenium flat-panel xray detectors
    • Zhao, W., DeCrescenzo, G., Rowlands, J. A., "Investigation of lag and ghosting in amorphous selenium flat-panel xray detectors," Proc. SPIE 4682, 9-20 (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 9-20
    • Zhao, W.1    DeCrescenzo, G.2    Rowlands, J.A.3
  • 7
    • 0032772594 scopus 로고    scopus 로고
    • A ghost story: Spatio-temporal response characteristics of an indirect-detection flat-panel imager
    • Siewerdsen, J. H., Jaffray, D. A., "A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager," Med. Phys. 26(8), 1624-1641 (1999).
    • (1999) Med. Phys. , vol.26 , Issue.8 , pp. 1624-1641
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 8
    • 0032428070 scopus 로고    scopus 로고
    • The effect of phosphor persistence on image quality in digital x-ray scanning systems
    • Mainprize, J. G., Yaffe, M. J., "The effect of phosphor persistence on image quality in digital x-ray scanning systems," Med. Phys. 25(12), 2440-2454 (1998).
    • (1998) Med. Phys. , vol.25 , Issue.12 , pp. 2440-2454
    • Mainprize, J.G.1    Yaffe, M.J.2
  • 9
    • 0031016807 scopus 로고    scopus 로고
    • Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation
    • Antonuk, L. E., el-Mohri, Y., Siewerdsen, J. H., Yorkston, J., Huang, W., Scarpine, V. E., Street, R. A., "Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation," Med. Phys. 24(1), 51-70 (1997).
    • (1997) Med. Phys. , vol.24 , Issue.1 , pp. 51-70
    • Antonuk, L.E.1    El-Mohri, Y.2    Siewerdsen, J.H.3    Yorkston, J.4    Huang, W.5    Carpine, V.E.6    Street, R.A.7
  • 11
    • 38249002658 scopus 로고
    • The computer generation of multinomial random variates
    • Davis, C. S., "The computer generation of multinomial random variates," Comput. Stat. Data Anal. 16(2), 205 (1993).
    • (1993) Comput. Stat. Data Anal. , vol.16 , Issue.2 , pp. 205
    • Davis, C.S.1
  • 13
    • 0033458079 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: effects of image lag
    • Siewerdsen, J. H., Jaffray, D. A., "Cone-beam computed tomography with a flat-panel imager: effects of image lag," Med. Phys. 26(12), 2635-2647 (1999).
    • (1999) Med. Phys. , vol.26 , Issue.12 , pp. 2635-2647
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 14
    • 56749165474 scopus 로고    scopus 로고
    • Three-dimensional linear system analysis for breast tomosynthesis
    • Zhao, B., Zhao, W., "Three-dimensional linear system analysis for breast tomosynthesis," Med. Phys. 35(12), 5219-5232 (2008).
    • (2008) Med. Phys. , vol.35 , Issue.12 , pp. 5219-5232
    • Zhao, B.1    Zhao, W.2
  • 15
    • 43149120917 scopus 로고    scopus 로고
    • Cascaded systems analysis of the 3D NEQ for conebeam CT and tomosynthesis
    • Tward, D. J., Siewerdsen, J. H., Fahrig, R. A., Pineda, A. R., "Cascaded systems analysis of the 3D NEQ for conebeam CT and tomosynthesis," Proc. SPIE 6913, 69131S (2008).
    • (2008) Proc. SPIE 6913
    • Tward, D.J.1    Siewerdsen, J.H.2    Fahrig, R.A.3    Pineda, A.R.4
  • 16
    • 0041375307 scopus 로고    scopus 로고
    • Three-dimensional NEQ transfer characteristics of volume CT using direct and indirect-detection flat-panel imagers
    • Siewerdsen, J. H., Jaffray, D. A., "Three-dimensional NEQ transfer characteristics of volume CT using direct- and indirect-detection flat-panel imagers," Proc. SPIE 5030, 92-102 (2003).
    • (2003) Proc. SPIE 5030 , pp. 92-102
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 17
    • 84975561076 scopus 로고
    • Analysis of signal and noise propagation for several imaging mechanisms
    • Rabbani, M., Metter, R. V., "Analysis of signal and noise propagation for several imaging mechanisms," J. Opt. Soc. Am. A 6(8), 1156-1164 (1989).
    • (1989) J. Opt. Soc. Am. A , Issue.8 , pp. 1156-1164
    • Rabbani, M.1    Metter, R.V.2
  • 20
    • 0025448718 scopus 로고
    • Incremental algorithm-a new fast backprojection scheme for parallel beam geometries
    • Cho, Z. H., Chen, C. M., Lee, S., "Incremental algorithm-a new fast backprojection scheme for parallel beam geometries," IEEE Trans. Med. Im. 9(2), 207-217 (1990).
    • (1990) IEEE Trans. Med. Im. , vol.9 , Issue.2 , pp. 207-217
    • Cho, Z.H.1    Chen, C.M.2    Lee, S.3
  • 21
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • Siddon, R. L., "Fast calculation of the exact radiological path for a three-dimensional CT array," Med. Phys. 12(2), 252-255 (1985).
    • (1985) Med. Phys. , vol.1 , Issue.2 , pp. 252-255
    • Siddon, R.L.1
  • 22
    • 54949143655 scopus 로고    scopus 로고
    • An empirical method for lag correction in cone-beam CT
    • Mail, N., Moseley, D. J., Siewerdsen, J. H., Jaffray, D. A., "An empirical method for lag correction in cone-beam CT," Med. Phys. 35(11), 5187-5196 (2008).
    • (2008) Med. Phys. , vol.35 , Issue.11 , pp. 5187-5196
    • Mail, N.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.