-
1
-
-
3042851780
-
Clinical impact of stent construction and design in percutaneous coronary intervention
-
DOI 10.1016/j.ahj.2003.12.007, PII S000287030300869X
-
Lau KW, Mak KH, Hung JS, Sigwart U. Clinical impact of stent construction and design in percutaneous coronary intervention. Am Heart J. 2004;147(5):764-773 (Pubitemid 38880980)
-
(2004)
American Heart Journal
, vol.147
, Issue.5
, pp. 764-773
-
-
Lau, K.-W.1
Mak, K.-H.2
Hung, J.-S.3
Sigwart, U.4
-
2
-
-
1542512537
-
Comparison of outcomes up to six months of heparin-coated with noncoated stents after percutaneous coronary intervention for acute myocardial infarction
-
Lev EI, Assali AR, Teplisky I, Rechavia E, Hasdai D, Sela O, et al. Comparison of outcomes up to six months of heparin-coated with noncoated stents after percutaneous coronary intervention for acute myocardial infarction. Am J Cardiol. 2004;93(6):741-743
-
(2004)
Am J Cardiol
, vol.93
, Issue.6
, pp. 741-743
-
-
Lev, E.I.1
Assali, A.R.2
Teplisky, I.3
Rechavia, E.4
Hasdai, D.5
Sela, O.6
-
4
-
-
0033182739
-
Coronary artery stenting
-
Ramsdale DR. Coronary artery stenting. Hosp Med. 1999;60(9): 624-629
-
(1999)
Hosp Med
, vol.60
, Issue.9
, pp. 624-629
-
-
Ramsdale, D.R.1
-
5
-
-
1942455829
-
Polymer-sirolimus-eluting stents in de novo lesions
-
Schuler G. Polymer-sirolimus-eluting stents in de novo lesions. Herz. 2004;29(2):152-161
-
(2004)
Herz
, vol.29
, Issue.2
, pp. 152-161
-
-
Schuler, G.1
-
6
-
-
0029038826
-
Coronary stents
-
Sigwart U. Coronary stents. Z Kardiol. 1995;84:65-77.
-
(1995)
Z Kardiol
, vol.84
, pp. 65-77
-
-
Sigwart, U.1
-
7
-
-
33846171184
-
Coronary stents: A materials perspective
-
Mani G, Feldman MD, Patel D, Agrawal CM. Coronary stents: a materials perspective. Biomaterials. 2007;28(9):1689-1710
-
(2007)
Biomaterials
, vol.28
, Issue.9
, pp. 1689-1710
-
-
Mani, G.1
Feldman, M.D.2
Patel, D.3
Agrawal, C.M.4
-
8
-
-
0037653841
-
-
Metals. In: Sigwart U, editor. London: W.B. Saunders Company Ltd
-
Taylor A. Metals. In: Sigwart U, editor. Endoluminal stenting. London: W.B. Saunders Company Ltd; 1996. p. 28-33.
-
(1996)
Endoluminal Stenting
, pp. 28-33
-
-
Taylor, A.1
-
9
-
-
0027795538
-
Nickel release from 304 and 316 stainless-steels in synthetic sweat-comparison with nickel and nickel-plated metals-consequences on allergic contact dermatitis
-
Haudrechy P, Foussereau J, Mantout B, Baroux B. Nickel release from 304 and 316 stainless-steels in synthetic sweat-comparison with nickel and nickel-plated metals-consequences on allergic contact dermatitis. Corros Sci. 1993;35(1-4):329-336
-
(1993)
Corros Sci
, vol.35
, Issue.1-4
, pp. 329-336
-
-
Haudrechy, P.1
Foussereau, J.2
Mantout, B.3
Baroux, B.4
-
10
-
-
0034597889
-
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
-
Koster R, Vieluf D, Kiehn M, Sommerauer M, Kahler J, Baldus S, et al. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 2000;356(9245):1895-1897
-
(2000)
Lancet
, vol.356
, Issue.9245
, pp. 1895-1897
-
-
Koster, R.1
Vieluf, D.2
Kiehn, M.3
Sommerauer, M.4
Kahler, J.5
Baldus, S.6
-
11
-
-
31744451760
-
-
Materials Park Ohio: ASM International
-
Davis JR. Metallic materials. Materials Park, Ohio: ASM International; 2003.
-
(2003)
Metallic Materials
-
-
Davis, J.R.1
-
12
-
-
84876228127
-
Metallic biomaterials
-
Park JB, Bronzio JD, editors. Boca Raton: CRC Press;
-
Park JB, Kim YK. Metallic biomaterials. In: Park JB, Bronzio JD, editors. Biomat principles and applications. Boca Raton: CRC Press; 2003. p. 1-20.
-
(2003)
Biomat principles and applications
, pp. 1-20
-
-
Park, J.B.1
Kim, Y.K.2
-
13
-
-
28844497993
-
Control of smooth muscle cell proliferation by ferrous iron
-
Mueller PP, May T, Perz A, Hauser H, Peuster M. Control of smooth muscle cell proliferation by ferrous iron. Biomaterials. 2006;27(10):2193-2200
-
(2006)
Biomaterials
, vol.27
, Issue.10
, pp. 2193-2200
-
-
Mueller, P.P.1
May, T.2
Perz, A.3
Hauser, H.4
Peuster, M.5
-
14
-
-
33744988409
-
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
-
Peuster M, Hesse C, Schloo T, Fink C, Beerbaum P, von Schnakenburg C. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta. Biomaterials. 2006;27(28):4955-4962
-
(2006)
Biomaterials
, vol.27
, Issue.28
, pp. 4955-4962
-
-
Peuster, M.1
Hesse, C.2
Schloo, T.3
Fink, C.4
Beerbaum, P.5
Von Schnakenburg, C.6
-
15
-
-
0034778878
-
A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits
-
Peuster M, Wohlsein P, Brugmann M, Ehlerding M, Seidler K, Fink C, et al. A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits. Heart. 2001;86(5):563-569
-
(2001)
Heart
, vol.86
, Issue.5
, pp. 563-569
-
-
Peuster, M.1
Wohlsein, P.2
Brugmann, M.3
Ehlerding, M.4
Seidler, K.5
Fink, C.6
-
16
-
-
0029830964
-
Restenosis-an open file
-
Gottsauner-Wolf M, Moliterno DJ, Lincoff AM, Topol EJ. Restenosis-an open file. Clin Cardiol. 1996;19(5):347-356
-
(1996)
Clin Cardiol
, vol.19
, Issue.5
, pp. 347-356
-
-
Gottsauner-Wolf, M.1
Moliterno, D.J.2
Lincoff, A.M.3
Topol, E.J.4
-
17
-
-
68249113188
-
Late stent thrombosis after drug-eluting stent: Seeing is understanding
-
Wijns W. Late stent thrombosis after drug-eluting stent: seeing is understanding. Circulation. 2009;120(5):364-365
-
(2009)
Circulation
, vol.120
, Issue.5
, pp. 364-365
-
-
Wijns, W.1
-
18
-
-
65649140821
-
DES design: Theoretical advantages and disadvantages of stent strut materials, design, thickness, and surface characteristics
-
Bailey SR. DES design: theoretical advantages and disadvantages of stent strut materials, design, thickness, and surface characteristics. J Interv Cardiol. 2009;22(s1):s3-17.
-
(2009)
J Interv Cardiol
, vol.22
, pp. 3-17
-
-
Bailey, S.R.1
-
19
-
-
0015270701
-
Investigation of 3-surface properties of several metals and their relation to blood compatibility
-
Depalma VA, Baier RE, Gott VL, Ford JW, Furuse A. Investigation of 3-surface properties of several metals and their relation to blood compatibility. J Biomed Mater Res. 1972;6(4):37-75.
-
(1972)
J Biomed Mater Res
, vol.6
, Issue.4
, pp. 37-75
-
-
Depalma, V.A.1
Baier, R.E.2
Gott, V.L.3
Ford, J.W.4
Furuse, A.5
-
20
-
-
0028962218
-
Kinetics of drug delivery to the arterial wall via polyurethanecoated removable nitinol stent: Comparative study of two drugs
-
Dev V, Eigler N, Sheth S, Lambert T, Forrester J, Litvack F. Kinetics of drug delivery to the arterial wall via polyurethanecoated removable nitinol stent: comparative study of two drugs. Cathet Cardiovasc Diagn. 1995;34(3):272-278
-
(1995)
Cathet Cardiovasc Diagn
, vol.34
, Issue.3
, pp. 272-278
-
-
Dev, V.1
Eigler, N.2
Sheth, S.3
Lambert, T.4
Forrester, J.5
Litvack, F.6
-
21
-
-
0027931803
-
Localized arterial wall drug delivery from a polymer-coated removable metallic stent. Kinetics, distribution, and bioactivity of forskolin
-
Lambert TL, Dev V, Rechavia E, Forrester JS, Litvack F, Eigler NL. Localized arterial wall drug delivery from a polymer-coated removable metallic stent. Kinetics, distribution, and bioactivity of forskolin. Circulation. 1994;90(2):1003-1011
-
(1994)
Circulation
, vol.90
, Issue.2
, pp. 1003-1011
-
-
Lambert, T.L.1
Dev, V.2
Rechavia, E.3
Forrester, J.S.4
Litvack, F.5
Eigler, N.L.6
-
23
-
-
0026470616
-
Percutaneous polymeric stents in porcine coronary artery initial experience with polyethylene terephtalate stents
-
Murphy JG, Schwartz RS, Edwards WD, Camrud AR, Vliestra RE, Holmer DR. Percutaneous polymeric stents in porcine coronary artery initial experience with polyethylene terephtalate stents. Circulation. 1992;86(5):1596-1604
-
(1992)
Circulation
, vol.86
, Issue.5
, pp. 1596-1604
-
-
Murphy, J.G.1
Schwartz, R.S.2
Edwards, W.D.3
Camrud, A.R.4
Vliestra, R.E.5
Holmer, D.R.6
-
24
-
-
0030131075
-
Role of polymers in improving the results of stenting in coronary arteries
-
Peng T, Gibula P, Yao KD, Goosen MF. Role of polymers in improving the results of stenting in coronary arteries. Biomaterials. 1996;17(7):685-694
-
(1996)
Biomaterials
, vol.17
, Issue.7
, pp. 685-694
-
-
Peng, T.1
Gibula, P.2
Yao, K.D.3
Goosen, M.F.4
-
25
-
-
4444369330
-
Effect of plasticization on heparin release from biodegradable matrices
-
Tan LP, Venkatraman SS, Sung PF, Wang XT. Effect of plasticization on heparin release from biodegradable matrices. Int J Pharm. 2004;283(1-2):89-96.
-
(2004)
Int J Pharm
, vol.283
, Issue.1-2
, pp. 89-96
-
-
Tan, L.P.1
Venkatraman, S.S.2
Sung, P.F.3
Wang, X.T.4
-
26
-
-
4444231182
-
Tyrphostin AGL-2043 eluting stent reduces neointima formation in porcine coronary arteries
-
Banai S, Gertz SD, Gavish L, Chorny M, Perez LS, Lazarovichi G, et al. Tyrphostin AGL-2043 eluting stent reduces neointima formation in porcine coronary arteries. Cardiovasc Res. 2004;64(1): 165-171
-
(2004)
Cardiovasc Res
, vol.64
, Issue.1
, pp. 165-171
-
-
Banai, S.1
Gertz, S.D.2
Gavish, L.3
Chorny, M.4
Perez, L.S.5
Lazarovichi, G.6
-
27
-
-
0029761378
-
Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
-
van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruys PW, Holmes DR Jr, et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation. 1996;94(7): 1690-1697
-
(1996)
Circulation
, vol.94
, Issue.7
, pp. 1690-1697
-
-
Van Der Giessen, W.J.1
Lincoff, A.M.2
Schwartz, R.S.3
Van Beusekom, H.M.4
Serruys, P.W.5
Holmes Jr., D.R.6
-
28
-
-
67650500353
-
Controlled delivery of paclitaxel from stent coatings using novel styrene maleic anhydride copolymer formulations
-
Richard R, Schwarz M, Chan K, Teigen N, Boden M. Controlled delivery of paclitaxel from stent coatings using novel styrene maleic anhydride copolymer formulations. J Biomed Mater Res Part A. 2008;90A(2):522-532
-
(2008)
J Biomed Mater Res Part A
, vol.90
, Issue.2
, pp. 522-532
-
-
Richard, R.1
Schwarz, M.2
Chan, K.3
Teigen, N.4
Boden, M.5
-
29
-
-
0025315437
-
Effect of controlled adventitial heparin delivery on smooth muscle cell proliferation following endothelial injury
-
Edelman ER, Adams DH, Karnovsky MJ. Effect of controlled adventitial heparin delivery on smooth muscle cell proliferation following endothelial injury. Proc Natl Acad Sci USA. 1990; 87(10):3773-3777
-
(1990)
Proc Natl Acad Sci USA
, vol.87
, Issue.10
, pp. 3773-3777
-
-
Edelman, E.R.1
Adams, D.H.2
Karnovsky, M.J.3
-
30
-
-
84964121845
-
Final report on the safety assessment of vinyl acetate/crotonic acid copolymer
-
Final Report on the Safety Assessment of Vinyl Acetate/Crotonic Acid Copolymer. Int J Tox 1983;2(5):125-140
-
(1983)
Int J Tox
, vol.2
, Issue.5
, pp. 125-140
-
-
-
31
-
-
0006897513
-
Preparation of polymeric biomaterials with the aid of radiation-chemical methods
-
Kabanov VY. Preparation of polymeric biomaterials with the aid of radiation-chemical methods. Russ Chem Rev. 1998;67:783-816.
-
(1998)
Russ Chem Rev
, vol.67
, pp. 783-816
-
-
Kabanov, V.Y.1
-
33
-
-
0016544481
-
Biological and physical characterization of some polyelectrolytes
-
Lundell EO, Byck JS, Kwiatkowski GT, Osterholts FD, Creasy WS, Stewart DD. Biological and physical characterization of some polyelectrolytes. Polym Prepr Am Chem Soc, Div Polym Chem. 1975;16(2):541-544
-
(1975)
Polym Prepr Am Chem Soc Div Polym Chem
, vol.16
, Issue.2
, pp. 541-544
-
-
Lundell, E.O.1
Byck, J.S.2
Kwiatkowski, G.T.3
Osterholts, F.D.4
Creasy, W.S.5
Stewart, D.D.6
-
34
-
-
1442325841
-
Polymeric biomaterials
-
Utrecht-Boston: VSP Books
-
Shtilman MI. Polymeric biomaterials. Part I. Polymer implants. Utrecht-Boston: VSP Books; 2003.
-
(2003)
Part I. Polymer Implants
-
-
Shtilman, M.I.1
|