메뉴 건너뛰기




Volumn 17, Issue 7, 1996, Pages 685-694

Role of polymers in improving the results of stenting in coronary arteries

Author keywords

Intracoronary stents; Metallic stents; Polymer paving; Polymeric stenting

Indexed keywords

BIOMATERIALS; BLOOD VESSELS; COATINGS; METALS; SURGERY;

EID: 0030131075     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/0142-9612(96)86738-X     Document Type: Article
Times cited : (107)

References (90)
  • 2
    • 0027436632 scopus 로고
    • Clinical and angiographic outcomes after coronary artery stenting for acute or threatened closure after percutaneous transluminal coronary angioplasty
    • Hearn JA, King SB, Douglas JS, Carlin SF, Lembo NJ, Ghazz IBM. Clinical and angiographic outcomes after coronary artery stenting for acute or threatened closure after percutaneous transluminal coronary angioplasty. Circulation 1993; 88: 2088-2096.
    • (1993) Circulation , vol.88 , pp. 2088-2096
    • Hearn, J.A.1    King, S.B.2    Douglas, J.S.3    Carlin, S.F.4    Lembo, N.J.5    Ghazz, I.B.M.6
  • 3
    • 0025272390 scopus 로고
    • Morphologic observations later after coronary balloon angioplasty: Mechanisms of acute injury and relationship to restenosis
    • Waller BF, Orr CM, Pinkerton CA, Van Tassel JW, Pinto RP. Morphologic observations later after coronary balloon angioplasty: mechanisms of acute injury and relationship to restenosis. Radiology 1990; 174: 961-967.
    • (1990) Radiology , vol.174 , pp. 961-967
    • Waller, B.F.1    Orr, C.M.2    Pinkerton, C.A.3    Van Tassel, J.W.4    Pinto, R.P.5
  • 4
    • 0027527078 scopus 로고
    • A novel stent deployment in the treatment of acute or threatened closure complicating balloon coronary angioplasty
    • Colombo A, Goldberg FSL, Almagor Y, Maiello L, Finci L. A novel stent deployment in the treatment of acute or threatened closure complicating balloon coronary angioplasty. J Am Coll Cardiol 1993; 20: 1887-1891.
    • (1993) J Am Coll Cardiol , vol.20 , pp. 1887-1891
    • Colombo, A.1    Goldberg, F.S.L.2    Almagor, Y.3    Maiello, L.4    Finci, L.5
  • 5
    • 0026539565 scopus 로고
    • Inhibition of cellular proliferation after experimental balloon angioplasty by low-molecular-weight heparin
    • Hanke H, Oberhoff M, Hanke S et al. Inhibition of cellular proliferation after experimental balloon angioplasty by low-molecular-weight heparin. Circulation 1992; 85: 1548-1556.
    • (1992) Circulation , vol.85 , pp. 1548-1556
    • Hanke, H.1    Oberhoff, M.2    Hanke, S.3
  • 6
    • 0028061452 scopus 로고
    • Long-term angiographic and clinical outcome after implantation of a balloon-expandable stent in the native coronary circulation
    • Savage PM, Fischman DL, Schatz RA et al. Long-term angiographic and clinical outcome after implantation of a balloon-expandable stent in the native coronary circulation. J Am Coll Cardiol 1994; 24: 1207-1212.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1207-1212
    • Savage, P.M.1    Fischman, D.L.2    Schatz, R.A.3
  • 7
    • 0028094698 scopus 로고
    • Coronary stenting for acute coronary dissection after coronary angioplasty: Implications of residual dissection
    • Alfonso F, Hernandez R, Goicoler J. Coronary stenting for acute coronary dissection after coronary angioplasty: implications of residual dissection. J Am Coll Cardiol 1994; 24: 989-995.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 989-995
    • Alfonso, F.1    Hernandez, R.2    Goicoler, J.3
  • 8
    • 0026008513 scopus 로고
    • Intravascular stents: General principles and status of lower-extremity arterial applications
    • Becker GJ. Intravascular stents: general principles and status of lower-extremity arterial applications. Circulation 1991; 83: I-122-I-136.
    • (1991) Circulation , vol.83
    • Becker, G.J.1
  • 9
    • 0023153178 scopus 로고
    • Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
    • Sigwart U, Prel J, Mirkoritch V, Joffre F, Kappenberger L. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. New Engl J Med 1987; 316: 701-706.
    • (1987) New Engl J Med , vol.316 , pp. 701-706
    • Sigwart, U.1    Prel, J.2    Mirkoritch, V.3    Joffre, F.4    Kappenberger, L.5
  • 10
    • 0024571386 scopus 로고
    • A view of vascular stents
    • Schatz RA. A view of vascular stents. Circulation 1989; 79: 445-457.
    • (1989) Circulation , vol.79 , pp. 445-457
    • Schatz, R.A.1
  • 12
    • 0027195816 scopus 로고
    • Multicenter investigation of coronary stenting to treat acute or threatened closure after percutaneous transluminal coronary angioplasty: Clinical and angiographic outcomes
    • Geore BS, Voorhees WD, Roubin GS. Multicenter investigation of coronary stenting to treat acute or threatened closure after percutaneous transluminal coronary angioplasty: clinical and angiographic outcomes. J Am Coll Cardiol 1993: 135-143.
    • (1993) J Am Coll Cardiol , pp. 135-143
    • Geore, B.S.1    Voorhees, W.D.2    Roubin, G.S.3
  • 13
    • 0027223628 scopus 로고
    • Serial angiographic follow-up after Palmaz-Schatz stent implantation: Comparison with conventional balloon angioplasty
    • Kimura T, Nosaka H, Iwabuchi M, Nobuyoshi M. Serial angiographic follow-up after Palmaz-Schatz stent implantation: comparison with conventional balloon angioplasty. J Am Coll Cardiol 1993; 21: 1557-1563.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 1557-1563
    • Kimura, T.1    Nosaka, H.2    Iwabuchi, M.3    Nobuyoshi, M.4
  • 14
    • 0025934823 scopus 로고
    • Percutaneous implantation of a new intracoronary stent in pigs
    • Bar FW, van Oppen J, de Swart H et al. Percutaneous implantation of a new intracoronary stent in pigs. Am Heart J 1991; 122: 1532-1541.
    • (1991) Am Heart J , vol.122 , pp. 1532-1541
    • Bar, F.W.1    Van Oppen, J.2    De Swart, H.3
  • 15
    • 0027525184 scopus 로고
    • Fate of lesion-related side branches after coronary artery stenting
    • Fischman DL, Savage MP, Leon MB et al. Fate of lesion-related side branches after coronary artery stenting. J Am Coll Cardiol 1993; 22: 1641-1646.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1641-1646
    • Fischman, D.L.1    Savage, M.P.2    Leon, M.B.3
  • 16
    • 0023760740 scopus 로고
    • Emergency stenting for acute occlusion after coronary balloon angioplasty
    • Sigwart U, Urban P, Golf S. Emergency stenting for acute occlusion after coronary balloon angioplasty. Circulation 1988; 78: 1121-1127.
    • (1988) Circulation , vol.78 , pp. 1121-1127
    • Sigwart, U.1    Urban, P.2    Golf, S.3
  • 17
    • 0026261773 scopus 로고
    • Percutaneous endovascular stenting: Development, investigation and application
    • Yang XM, Manninen H, Matsi P, Soimakallio S. Percutaneous endovascular stenting: development, investigation and application. Eur J Radiol 1991; 13: 161-173.
    • (1991) Eur J Radiol , vol.13 , pp. 161-173
    • Yang, X.M.1    Manninen, H.2    Matsi, P.3    Soimakallio, S.4
  • 19
    • 0027232361 scopus 로고
    • New revascularization devices: Update on coronary stents
    • Satler LF, Popma JJ, Mintz GS et al. New revascularization devices: update on coronary stents. Prim Cardiol 1993; 19: 18-30.
    • (1993) Prim Cardiol , vol.19 , pp. 18-30
    • Satler, L.F.1    Popma, J.J.2    Mintz, G.S.3
  • 20
    • 0025960042 scopus 로고
    • Angiographic follow-up after placement of a self-expanding coronary artery stent
    • Serruys PW, Strauss BH, Beatt KT. Angiographic follow-up after placement of a self-expanding coronary artery stent. N Engl J Med 1991; 324: 13-17.
    • (1991) N Engl J Med , vol.324 , pp. 13-17
    • Serruys, P.W.1    Strauss, B.H.2    Beatt, K.T.3
  • 21
    • 0025896522 scopus 로고
    • Early outcome after placement of metallic intracoronary stents: Initial Mayo Clinic experience
    • Garratt KN, Holmes DR. Early outcome after placement of metallic intracoronary stents: initial Mayo Clinic experience. Mayo Clin Proc 1991; 66: 268-275.
    • (1991) Mayo Clin Proc , vol.66 , pp. 268-275
    • Garratt, K.N.1    Holmes, D.R.2
  • 22
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys PW, Jaegere PD, Kiemeneij F et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. New Engl J Med 1994; 331: 489-495.
    • (1994) New Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    Jaegere, P.D.2    Kiemeneij, F.3
  • 23
    • 0027934377 scopus 로고
    • A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fischman DL, Leon MB, Baim DS et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. New Engl J Med 1994; 331: 496-510.
    • (1994) New Engl J Med , vol.331 , pp. 496-510
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 24
    • 0028087616 scopus 로고
    • Caveats about elective coronary stenting
    • Topol EJ. Caveats about elective coronary stenting. New Engl J Med 1994; 331: 539-541.
    • (1994) New Engl J Med , vol.331 , pp. 539-541
    • Topol, E.J.1
  • 25
    • 0026579839 scopus 로고
    • Wiktor stent implantation in patients with restenosis following balloon angioplasty of a native coronary artery
    • De Jaegere PP, Serruys DW, Bertrand ME. Wiktor stent implantation in patients with restenosis following balloon angioplasty of a native coronary artery. Am J Cardiol 1992; 69: 598-602.
    • (1992) Am J Cardiol , vol.69 , pp. 598-602
    • De Jaegere, P.P.1    Serruys, D.W.2    Bertrand, M.E.3
  • 26
    • 0026514037 scopus 로고
    • Effects of design geometry of intravascular endoprostheses on stenosis rate in normal rabbits
    • Tominaga R, Kambic HE, Emoto H, Harasaki H, Sutton C, Hollman J. Effects of design geometry of intravascular endoprostheses on stenosis rate in normal rabbits. Am Heart J 1992; 123: 21.
    • (1992) Am Heart J , vol.123 , pp. 21
    • Tominaga, R.1    Kambic, H.E.2    Emoto, H.3    Harasaki, H.4    Sutton, C.5    Hollman, J.6
  • 27
    • 0025610461 scopus 로고
    • Restenosis after balloon angioplasty: A practical proliferative model in porcine coronary arteries
    • Schwartz RS, Murphy JC, Edwards WD. Restenosis after balloon angioplasty: a practical proliferative model in porcine coronary arteries. Circulation 1990; 82: 2190-2200.
    • (1990) Circulation , vol.82 , pp. 2190-2200
    • Schwartz, R.S.1    Murphy, J.C.2    Edwards, W.D.3
  • 28
    • 0015270701 scopus 로고
    • Investigation of three-surface properties of several metals and their relation to blood compatibility
    • De Palma VA, Bauerre FJW, Gett VL, Furuse A. Investigation of three-surface properties of several metals and their relation to blood compatibility. J Biomed Mater Res Symp 1972; 3: 37-75.
    • (1972) J Biomed Mater Res Symp , vol.3 , pp. 37-75
    • De Palma, V.A.1    Bauerre, F.J.W.2    Gett, V.L.3    Furuse, A.4
  • 29
    • 0027472107 scopus 로고
    • A new expandable intracoronary tantalum (Strecker) stent: Early experimental results and follow-up to twelve months
    • Riveiro PA, Gallo R, Antonius J et al. A new expandable intracoronary tantalum (Strecker) stent: early experimental results and follow-up to twelve months. Am Heart J 1993; 125: 501-510.
    • (1993) Am Heart J , vol.125 , pp. 501-510
    • Riveiro, P.A.1    Gallo, R.2    Antonius, J.3
  • 30
    • 0027439822 scopus 로고
    • Intravascular stents: Tissue-stent interactions and design considerations
    • Palmax JC. Intravascular stents: tissue-stent interactions and design considerations. Am J Radiol 1993; 160: 613-618.
    • (1993) Am J Radiol , vol.160 , pp. 613-618
    • Palmax, J.C.1
  • 31
    • 0026584101 scopus 로고
    • Evaluation of poly(L-lactic acid) as material for intravascular polymeric stents
    • Agrawal CM, Haas KF, Leopold DA, Clark HG. Evaluation of poly(L-lactic acid) as material for intravascular polymeric stents. Biomaterials 1992; 13: 176-182.
    • (1992) Biomaterials , vol.13 , pp. 176-182
    • Agrawal, C.M.1    Haas, K.F.2    Leopold, D.A.3    Clark, H.G.4
  • 32
    • 85030190768 scopus 로고
    • Absorbable poly(alpha ester) materials for temporary endovascular stenting in balloon angioplasty (PTCA)
    • 20-23 May
    • Zdrahala RJ. Absorbable poly(alpha ester) materials for temporary endovascular stenting in balloon angioplasty (PTCA). The 16th Annual Meeting of the Society of Biomaterials 20-23 May 1990: 155.
    • (1990) The 16th Annual Meeting of the Society of Biomaterials , pp. 155
    • Zdrahala, R.J.1
  • 37
    • 4243629602 scopus 로고
    • The temporary stent catheter: A non-operative treatment for acute occlusion during coronary angioplasty
    • Gaspard PE, Didier BP, Delsanti GL. The temporary stent catheter: a non-operative treatment for acute occlusion during coronary angioplasty (abstr.), J Am Coll Cardiol 1991; 15: 118A.
    • (1991) J Am Coll Cardiol , vol.15
    • Gaspard, P.E.1    Didier, B.P.2    Delsanti, G.L.3
  • 38
    • 0028040967 scopus 로고
    • Polymeric stenting in the porcine coronary artery model: Differential outcome of exogenous fibrin sleeves versus polyurethane-coated stents
    • Holmes DR, Camrud AR, Jorgenson MA, Edwards WD, Schwartz RS. Polymeric stenting in the porcine coronary artery model: differential outcome of exogenous fibrin sleeves versus polyurethane-coated stents. J Am Coll Cardiol 1994; 24: 525-531.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 525-531
    • Holmes, D.R.1    Camrud, A.R.2    Jorgenson, M.A.3    Edwards, W.D.4    Schwartz, R.S.5
  • 39
    • 0343980193 scopus 로고
    • Randomized trial of coronary stent implantation without anticoagulation aspirin vs. ticlopidine
    • Blengino S, Maielo L, Hall P, Nakamura S, Giovanni M, Colombo A. Randomized trial of coronary stent implantation without anticoagulation aspirin vs. ticlopidine. Circulation 1994; 90: I-24.
    • (1994) Circulation , vol.90
    • Blengino, S.1    Maielo, L.2    Hall, P.3    Nakamura, S.4    Giovanni, M.5    Colombo, A.6
  • 40
    • 0004055683 scopus 로고
    • Reduction of subacute thrombosis rate after coronary stenting using a new anticoagulant protocol
    • Jordan C, Carvalho H, Fajadet J, Bernard C, Robert G, Marco J. Reduction of subacute thrombosis rate after coronary stenting using a new anticoagulant protocol. Circulation 1994; 90: I-25.
    • (1994) Circulation , vol.90
    • Jordan, C.1    Carvalho, H.2    Fajadet, J.3    Bernard, C.4    Robert, G.5    Marco, J.6
  • 41
    • 0023684028 scopus 로고
    • Self-expanding endovascular graft: An experimental study in dogs
    • Yoshioka T, Mirich D, Wright KC, Wallace S. Self-expanding endovascular graft: an experimental study in dogs. Am J Radiol 1988; 15: 673-676.
    • (1988) Am J Radiol , vol.15 , pp. 673-676
    • Yoshioka, T.1    Mirich, D.2    Wright, K.C.3    Wallace, S.4
  • 42
    • 0001205509 scopus 로고
    • Intraarterial compatibility of a balloon-expandable tubular graft
    • Roeren T, Garcia OJ, Palmaz JC, Rees CR, Tio FO. Intraarterial compatibility of a balloon-expandable tubular graft. Radiology 1990; 174: 1069.
    • (1990) Radiology , vol.174 , pp. 1069
    • Roeren, T.1    Garcia, O.J.2    Palmaz, J.C.3    Rees, C.R.4    Tio, F.O.5
  • 43
    • 0343929068 scopus 로고
    • Amphiphilic polyurethane coating of intracoronary stents decreases mortality due to subacute thrombosis in a porcine coronary model
    • De Scheerder IK, Wilczek KF, Verbeken E et al. Amphiphilic polyurethane coating of intracoronary stents decreases mortality due to subacute thrombosis in a porcine coronary model. J Am Coll Cardiol 1994; 23: 186A.
    • (1994) J Am Coll Cardiol , vol.23
    • De Scheerder, I.K.1    Wilczek, K.F.2    Verbeken, E.3
  • 44
    • 0343493352 scopus 로고
    • Prevention of stent subacute thrombosis by segmented polyurethane-polyethylene oxide-heparin coating in the rabbit carotid
    • Sheth S, Park KD, Dev V et al. Prevention of stent subacute thrombosis by segmented polyurethane-polyethylene oxide-heparin coating in the rabbit carotid. Am J Coll Cardiol 1994; 23: 187A.
    • (1994) Am J Coll Cardiol , vol.23
    • Sheth, S.1    Park, K.D.2    Dev, V.3
  • 45
    • 0342623057 scopus 로고
    • Native fibrin film as a biocompatible, absorbable material for intracoronary stent implant and drug delivery
    • Schwartz RS, Huber KC, Edwards WD et al. Native fibrin film as a biocompatible, absorbable material for intracoronary stent implant and drug delivery. J Am Coll Cardiol 1992; 19: 171A.
    • (1992) J Am Coll Cardiol , vol.19
    • Schwartz, R.S.1    Huber, K.C.2    Edwards, W.D.3
  • 46
    • 0027174324 scopus 로고
    • Endovascular stents: Preliminary clinical results and future developments
    • de Jaegere PPT. Endovascular stents: preliminary clinical results and future developments. Clin Cardiol 1993; 16: 369-378.
    • (1993) Clin Cardiol , vol.16 , pp. 369-378
    • De Jaegere, P.P.T.1
  • 47
    • 0001829123 scopus 로고
    • Sustained local drug delivery by a novel intravascular eluting stent to prevent restenosis in the porcine coronary artery
    • Lincoff AM, Furst JG, Ellis SG, Topol EJ. Sustained local drug delivery by a novel intravascular eluting stent to prevent restenosis in the porcine coronary artery. J Am Coll Cardiol 1994; 23: 18A.
    • (1994) J Am Coll Cardiol , vol.23
    • Lincoff, A.M.1    Furst, J.G.2    Ellis, S.G.3    Topol, E.J.4
  • 48
    • 9244226140 scopus 로고
    • Local arterial wall drug delivery from a polymer coated removable metallic stent: Kinetics, distribution and bioactivity of forskolin
    • Eigler NL, Lambert TL, Dev V et al. Local arterial wall drug delivery from a polymer coated removable metallic stent: kinetics, distribution and bioactivity of forskolin. J Am Coll Cardiol 1994; 23: 4A.
    • (1994) J Am Coll Cardiol , vol.23
    • Eigler, N.L.1    Lambert, T.L.2    Dev, V.3
  • 51
    • 0027628397 scopus 로고
    • Cardiovascular device for the 1990s
    • Szycher M, Lee SJ. Cardiovascular device for the 1990s. J Biomater Appl 1993; 8: 31-63.
    • (1993) J Biomater Appl , vol.8 , pp. 31-63
    • Szycher, M.1    Lee, S.J.2
  • 52
    • 0342623056 scopus 로고
    • Silicone elastomers for implantable biomedical devices
    • Szycher M, ed. Technomic Publishing Co. Inc.
    • Devanathan TD. Silicone elastomers for implantable biomedical devices. In: Szycher M, ed. Biocompatible Polymers, Metals and Composites. Technomic Publishing Co. Inc., 1983: 769.
    • (1983) Biocompatible Polymers, Metals and Composites , pp. 769
    • Devanathan, T.D.1
  • 53
    • 0028144222 scopus 로고
    • Supporting microsporous elastomeric, degradable prostheses to improve the arterialization of autologous vein grafts
    • Hinrichs WLJ, Zweep HP, Satoh S, Feijen J, Wildevaur ChRH. Supporting microsporous elastomeric, degradable prostheses to improve the arterialization of autologous vein grafts. Biomaterials 1994; 15: 83-91.
    • (1994) Biomaterials , vol.15 , pp. 83-91
    • Hinrichs, W.L.J.1    Zweep, H.P.2    Satoh, S.3    Feijen, J.4    Wildevaur, Ch.R.H.5
  • 55
    • 0026470616 scopus 로고
    • Percutaneous polymeric stents in porcine coronary arteries: Initial experience with polyethylene terephthalate stents
    • Murphy JG, Schwartz RS, Edwards WD, Camrud AR, Vliletstra RE, Holmes DR. Percutaneous polymeric stents in porcine coronary arteries: initial experience with polyethylene terephthalate stents. Circulation 1992; 86: 1596-1604.
    • (1992) Circulation , vol.86 , pp. 1596-1604
    • Murphy, J.G.1    Schwartz, R.S.2    Edwards, W.D.3    Camrud, A.R.4    Vliletstra, R.E.5    Holmes, D.R.6
  • 57
    • 0026515530 scopus 로고
    • Restenosis and the proportional neointimal response to coronary artery
    • Schwartz RS, Huber KL, Murphy JG et al. Restenosis and the proportional neointimal response to coronary artery. J Am Coll Cardiol 1992; 19: 267-274.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 267-274
    • Schwartz, R.S.1    Huber, K.L.2    Murphy, J.G.3
  • 58
    • 0343929067 scopus 로고
    • Intramural deposition of urokinase at the angioplasty site - Comparative efficiency of systemic and local drug delivery techniques
    • Mitchel JF, Azrin MA, Fram DB et al. Intramural deposition of urokinase at the angioplasty site - Comparative efficiency of systemic and local drug delivery techniques. Circulation 1994; 90: I-20.
    • (1994) Circulation , vol.90
    • Mitchel, J.F.1    Azrin, M.A.2    Fram, D.B.3
  • 60
    • 84993887330 scopus 로고
    • Local delivery of Heparin with a PTCT infusion balloon inhibits platelet-dependent thrombosis
    • Thomas CN, Barry JJ, King SB, Scott NA. Local delivery of Heparin with a PTCT infusion balloon inhibits platelet-dependent thrombosis. J Am Coll Cardiol 1994; 23: 4A.
    • (1994) J Am Coll Cardiol , vol.23
    • Thomas, C.N.1    Barry, J.J.2    King, S.B.3    Scott, N.A.4
  • 61
    • 26344456623 scopus 로고
    • Local delivery of taxol inhibits neointimal regrowth following balloon injury of the rat carotid artery
    • Jenkins GM, Leong K, Heller P et al. Local delivery of taxol inhibits neointimal regrowth following balloon injury of the rat carotid artery. Circulation 1994; 90: I-297.
    • (1994) Circulation , vol.90
    • Jenkins, G.M.1    Leong, K.2    Heller, P.3
  • 62
    • 84993891249 scopus 로고
    • Local delivery of γ-hirudin by a double balloon perfusion catheter inhibits platelet deposition post angioplasty
    • Meyer B, Fernandez-Ortiz F, Fuster V et al. Local delivery of γ-hirudin by a double balloon perfusion catheter inhibits platelet deposition post angioplasty. J Am Coll Cardiol 1994; 23: 18A.
    • (1994) J Am Coll Cardiol , vol.23
    • Meyer, B.1    Fernandez-Ortiz, F.2    Fuster, V.3
  • 63
    • 26344451339 scopus 로고
    • Local delivery of a YIGSR peptide inhibits neointimal hyperplasia following balloon injury
    • Slepian MJ, Massia SP. Local delivery of a YIGSR peptide inhibits neointimal hyperplasia following balloon injury. Circulation 1994; 90: I-297.
    • (1994) Circulation , vol.90
    • Slepian, M.J.1    Massia, S.P.2
  • 64
    • 0019941605 scopus 로고
    • A simple, indwelling, biliary endoprosthesis made from commonly available catheter material
    • Rfng EJ, Schwarz W, McLean GK, Freiman A. A simple, indwelling, biliary endoprosthesis made from commonly available catheter material. Am J Radiol 1982; 139: 615-619.
    • (1982) Am J Radiol , vol.139 , pp. 615-619
    • Rfng, E.J.1    Schwarz, W.2    McLean, G.K.3    Freiman, A.4
  • 65
    • 0026489489 scopus 로고
    • Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction
    • Davids PHP, Groen AK, Rauws EAJ, Tytgat GNJ, Huibregtse K. Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction. Lancet 1992; 340: 1488-1492.
    • (1992) Lancet , vol.340 , pp. 1488-1492
    • Davids, P.H.P.1    Groen, A.K.2    Rauws, E.A.J.3    Tytgat, G.N.J.4    Huibregtse, K.5
  • 66
    • 0026640005 scopus 로고
    • Use of Teflon stents for lymphovenous anastomosis
    • Shaper NJ, Rutt DR, Browse NL. Use of Teflon stents for lymphovenous anastomosis. Br J Surg 1992; 79: 633-636.
    • (1992) Br J Surg , vol.79 , pp. 633-636
    • Shaper, N.J.1    Rutt, D.R.2    Browse, N.L.3
  • 70
    • 0023137024 scopus 로고
    • Self-expanding metallic stents for small vessels: An experimental evaluation
    • Duprat G, Wright KC, Charnsangavej C, Wallace S, Gianturco C. Self-expanding metallic stents for small vessels: an experimental evaluation. Radiology 1987; 162: 469-472.
    • (1987) Radiology , vol.162 , pp. 469-472
    • Duprat, G.1    Wright, K.C.2    Charnsangavej, C.3    Wallace, S.4    Gianturco, C.5
  • 71
    • 26344471552 scopus 로고
    • A new biocompatible polymeric coronary stent: Design and early results in a pig model
    • Murphy JG, Schwartz RS, Kennedy K et al. A new biocompatible polymeric coronary stent: design and early results in a pig model. J Am Coll Cardiol 1990; 15: 105A.
    • (1990) J Am Coll Cardiol , vol.15
    • Murphy, J.G.1    Schwartz, R.S.2    Kennedy, K.3
  • 76
    • 0026447482 scopus 로고
    • Deformation characteristics of a bioabsorbable intravascular stent
    • Agrawal CM, Clark HG. Deformation characteristics of a bioabsorbable intravascular stent. Invest Radiol 1992; 27: 1020-1024.
    • (1992) Invest Radiol , vol.27 , pp. 1020-1024
    • Agrawal, C.M.1    Clark, H.G.2
  • 77
    • 0007128361 scopus 로고
    • A bioabsorbable stent: Initial experimental results
    • Chapman GD, Gammon RS, Bauman RP et al. A bioabsorbable stent: initial experimental results. Circulation 1990; 82: III-72.
    • (1990) Circulation , vol.82
    • Chapman, G.D.1    Gammon, R.S.2    Bauman, R.P.3
  • 78
    • 0025335808 scopus 로고
    • Uber eine neue ballonexpandierbare kunststoffendoprosthese: Erster erfahrungsbericht uber den modellierbaren thermostent
    • Beck A. Uber eine neue ballonexpandierbare kunststoffendoprosthese: erster erfahrungsbericht uber den modellierbaren thermostent. Radiologe 1990; 30: 347-350.
    • (1990) Radiologe , vol.30 , pp. 347-350
    • Beck, A.1
  • 80
    • 0007135349 scopus 로고
    • Biodegradable polymer can evoke a unique inflammatory response when implanted in the coronary artery
    • Lincoff AM, Schwartz RS, van der Giessen WJ et al. Biodegradable polymer can evoke a unique inflammatory response when implanted in the coronary artery. Circulation 1992; 86: I-801.
    • (1992) Circulation , vol.86
    • Lincoff, A.M.1    Schwartz, R.S.2    Van Der Giessen, W.J.3
  • 81
    • 0001443121 scopus 로고
    • Synthesis of biodegradable polyesteramides with pendant functional groups
    • in't Veld PJ, Dijkstra PJ, Feijen J. Synthesis of biodegradable polyesteramides with pendant functional groups. Makromol Chem 1992; 193: 2713-2730.
    • (1992) Makromol Chem , vol.193 , pp. 2713-2730
    • In't Veld, P.J.1    Dijkstra, P.J.2    Feijen, J.3
  • 82
    • 0344508294 scopus 로고
    • Synthesis and RGD peptide modification of a new biodegradable copolymer: Poly(lactic acid-co-lysine)
    • Barrera DA, Iylstra E, Lansbury PT, Langer R. Synthesis and RGD peptide modification of a new biodegradable copolymer: poly(lactic acid-co-lysine). J Am Chem Soc 1993; 115: 11010-11011.
    • (1993) J Am Chem Soc , vol.115 , pp. 11010-11011
    • Barrera, D.A.1    Iylstra, E.2    Lansbury, P.T.3    Langer, R.4
  • 83
    • 0343057399 scopus 로고
    • The development of poly(L-lactic acid-co-L-lysine) for tissue engineering: Functionalization and new monomer synthesis
    • Hrkach JS, Ou J, Langer R. The development of poly(L-lactic acid-co-L-lysine) for tissue engineering: functionalization and new monomer synthesis. Polym Preprint 1994; 35(2): 450-451.
    • (1994) Polym Preprint , vol.35 , Issue.2 , pp. 450-451
    • Hrkach, J.S.1    Ou, J.2    Langer, R.3
  • 84
    • 4243334495 scopus 로고
    • Local delivery of a cyclic RGD peptide inhibits neointimal hyperplasia following balloon injury
    • Slepian MJ, Massia SP. Local delivery of a cyclic RGD peptide inhibits neointimal hyperplasia following balloon injury. Circulation 1993; 88: I-372.
    • (1993) Circulation , vol.88
    • Slepian, M.J.1    Massia, S.P.2
  • 85
    • 0343057401 scopus 로고
    • Antithrombogenic biomedical materials improved by enzyme immobilization technique
    • Szycher M, ed. Technomic Publishing Co. Inc.
    • Minra Y. Antithrombogenic biomedical materials improved by enzyme immobilization technique. In: Szycher M, ed. Biocompatible Polymers, Metals, and Composites. Technomic Publishing Co. Inc., 1983: 301.
    • (1983) Biocompatible Polymers, Metals, and Composites , pp. 301
    • Minra, Y.1
  • 86
    • 0011478123 scopus 로고
    • Polymeric endoluminal paving/sealing: A biodegradable alternative to intracoronary stenting
    • Slepian MJ, Schindler A. Polymeric endoluminal paving/sealing: a biodegradable alternative to intracoronary stenting. Circulation 1988; 78: II-409.
    • (1988) Circulation , vol.78
    • Slepian, M.J.1    Schindler, A.2
  • 87
    • 85030196373 scopus 로고
    • The hydrogel barriers for prevention of thrombosis and intimal thickening after balloon injury
    • West HJL, Chowdhury SM, Slepian MJ, Hubbell JA. The hydrogel barriers for prevention of thrombosis and intimal thickening after balloon injury. J Am Coll Cardiol 1994; 24: 5A.
    • (1994) J Am Coll Cardiol , vol.24
    • West, H.J.L.1    Chowdhury, S.M.2    Slepian, M.J.3    Hubbell, J.A.4
  • 88
    • 0343929061 scopus 로고
    • Biodegradable endoluminal polymer layers provide sustained transmural heparin delivery to the arterial wall in vivo
    • Slepian MJ, Campbell PK, Berrigan K et al. Biodegradable endoluminal polymer layers provide sustained transmural heparin delivery to the arterial wall in vivo. Circulation 1994; 90: I-20.
    • (1994) Circulation , vol.90
    • Slepian, M.J.1    Campbell, P.K.2    Berrigan, K.3
  • 89
    • 0343929060 scopus 로고
    • Resorbable hydrogel barriers for controlling intravascular thrombosis and healing
    • Hill West JL, Chowdhury SM, Slepian MJ, Hubbell JA. Resorbable hydrogel barriers for controlling intravascular thrombosis and healing. Polym Preprint 1994; 35(2): 396-398.
    • (1994) Polym Preprint , vol.35 , Issue.2 , pp. 396-398
    • Hill West, J.L.1    Chowdhury, S.M.2    Slepian, M.J.3    Hubbell, J.A.4
  • 90
    • 0001100976 scopus 로고
    • Endoluminal gel paving using in situ biodegradable photopolymerized hydrogel: Acute efficacy in the rabbit
    • Slepian MJ, Massia SP, Sawhney A. Endoluminal gel paving using in situ biodegradable photopolymerized hydrogel: acute efficacy in the rabbit. Circulation 1993; 88: I-660.
    • (1993) Circulation , vol.88
    • Slepian, M.J.1    Massia, S.P.2    Sawhney, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.