메뉴 건너뛰기




Volumn 57, Issue 3 PART 2, 2010, Pages 1496-1501

Measurements of relative depth doses using fiber-optic radiation sensor and EBT film for brachytherapy dosimetry

Author keywords

Brachytherapy; Cerenkov light; Dosimeter; Optical fiber; Organic scintillator; Relative depth dose

Indexed keywords

ACCURATE MEASUREMENT; BRACHYTHERAPY; CERENKOV LIGHT; DEPTH DOSE; DOSE MEASUREMENT; DOSIMETRY FILMS; FIBER-OPTIC RADIATION SENSORS; HIGH DOSE; ORGANIC SCINTILLATOR; RADIATION FIELD; REAL-TIME RESPONSE; SUBTRACTION METHOD; WAVELENGTH SHIFTING;

EID: 77953946219     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2010.2043263     Document Type: Conference Paper
Times cited : (13)

References (24)
  • 1
    • 0034315504 scopus 로고    scopus 로고
    • A multichannel dosimeter based on scintillating fibers for medical application
    • K. H. Beck, J. Drees, K. Goldmann, I. M. Gregor, and M. Heintz, "A multichannel dosimeter based on scintillating fibers for medical application, " Nucl. Instrum. Phys. Res. A., vol. 454, no. 1, pp. 147-151, 2000.
    • (2000) Nucl. Instrum. Phys. Res. A. , vol.454 , Issue.1 , pp. 147-151
    • Beck, K.H.1    Drees, J.2    Goldmann, K.3    Gregor, I.M.4    Heintz, M.5
  • 2
    • 0042674083 scopus 로고    scopus 로고
    • High dose-rate brachytherapy source localization: Positional resolution using a diamond detector
    • T. Nakano, N. Suchowerska, M. M. Bilek, D. R. McKenzie, N. Ng, and T. Kron, "High dose-rate brachytherapy source localization: Positional resolution using a diamond detector, " Phys. Med. Biol., vol. 48, no. 14, pp. 2133-2146, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , Issue.14 , pp. 2133-2146
    • Nakano, T.1    Suchowerska, N.2    Bilek, M.M.3    McKenzie, D.R.4    Ng, N.5    Kron, T.6
  • 3
    • 77953935847 scopus 로고
    • Optimum plastic scintillator and optical fiber combination for brachytherapy dosimetry
    • M. R. Arnfield, H. E. Gaballa, R. D. Zwicker, Q. Islam, and R. S. Ullrich, "Optimum plastic scintillator and optical fiber combination for brachytherapy dosimetry, " in t. J. Radiat. Oncol. Biol. Phys., vol. 32, no. 971, pp. 296-296, 1995.
    • (1995) T. J. Radiat. Oncol. Biol. Phys. , vol.32 , Issue.971 , pp. 296-296
    • Arnfield, M.R.1    Gaballa, H.E.2    Zwicker, R.D.3    Islam, Q.4    Ullrich, R.S.5
  • 5
    • 34247616143 scopus 로고    scopus 로고
    • In vivo dosimeters for HDR brachytherapy: A comparison of a diamond detector, MOSFET, TLD, and scintillation detector
    • J. Lambert, T. Nakano, S. Law, J. Elsey, D. R. Mckenzie, and N. Suchowerska, "In vivo dosimeters for HDR brachytherapy: A comparison of a diamond detector, MOSFET, TLD, and scintillation detector, " Med. Phys., vol. 34, no. 5, pp. 1759-1765, 2007.
    • (2007) Med. Phys. , vol.34 , Issue.5 , pp. 1759-1765
    • Lambert, J.1    Nakano, T.2    Law, S.3    Elsey, J.4    Mckenzie, D.R.5    Suchowerska, N.6
  • 6
    • 33751168473 scopus 로고    scopus 로고
    • A plastic scintillation dosimeter for high dose rate brachytherapy
    • J. Lambert, D. R. McKenzie, S. Law, J. Elsey, and N. Suchowerska, "A plastic scintillation dosimeter for high dose rate brachytherapy, " Phys. Med. Biol., vol. 51, pp. 5505-5516, 2006.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 5505-5516
    • Lambert, J.1    McKenzie, D.R.2    Law, S.3    Elsey, J.4    Suchowerska, N.5
  • 7
    • 0026804696 scopus 로고
    • Water equivalent plastic scintillation detectors for high-energy beam dosimetry I
    • A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water equivalent plastic scintillation detectors for high-energy beam dosimetry I, " Phys. Med. Biol., vol. 37, no. 10, pp. 1883-1900, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , Issue.10 , pp. 1883-1900
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 8
    • 0026793771 scopus 로고
    • Water equivalent plastic scintillation detectors for high-energy beam dosimetry II properties and measurements
    • A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water equivalent plastic scintillation detectors for high-energy beam dosimetry II properties and measurements, " Phys. Med. Biol., vol. 37, no. 10, pp. 1901-1913, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , Issue.10 , pp. 1901-1913
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 10
    • 34248504862 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry and its application to radio therapy
    • A. S. Beddar, "Plastic scintillation dosimetry and its application to radio therapy, " Radiat. Meas., vol. 41, pp. S124-S133, 2007.
    • (2007) Radiat. Meas. , vol.41
    • Beddar, A.S.1
  • 11
    • 0032773186 scopus 로고    scopus 로고
    • Towards to twodimensional brachytherapy dosimetry using plastic scintillator: New highly efficient water equivalent plastic scintillator materials
    • A. S. Kirov, C. Hurlbut, J. F. Dempsey, S. B. Shrinivas, J. W. Epstein, W. R. Binns, P. F. Dowkontt, and J. F. Williamson, "Towards to twodimensional brachytherapy dosimetry using plastic scintillator: New highly efficient water equivalent plastic scintillator materials, " Med. Phys., vol. 26, no. 8, pp. 1515-1523, 1999.
    • (1999) Med. Phys. , vol.26 , Issue.8 , pp. 1515-1523
    • Kirov, A.S.1    Hurlbut, C.2    Dempsey, J.F.3    Shrinivas, S.B.4    Epstein, J.W.5    Binns, W.R.6    Dowkontt, P.F.7    Williamson, J.F.8
  • 12
    • 25644453647 scopus 로고    scopus 로고
    • Spectral discrimination of cerenkov radiation in scintillating dosimeters
    • A.-M. Frelin, J.-M. Fontbonne, G. Ban, J. Colin, and M. Labalme, "Spectral discrimination of cerenkov radiation in scintillating dosimeters, " Med. Phys., vol. 32, pp. 3000-3006, 2005.
    • (2005) Med. Phys. , vol.32 , pp. 3000-3006
    • Frelin, A.-M.1    Fontbonne, J.-M.2    Ban, G.3    Colin, J.4    Labalme, M.5
  • 13
    • 34547895500 scopus 로고    scopus 로고
    • Measurements and characterizations of cerenkov light in fiberoptic radiation sensor irradiated by high energy electron beam
    • B. Lee, D. H. Cho, K. W. Jang, S. C. Chung, J. W. Lee, S. Kim, and H. Cho, "Measurements and characterizations of cerenkov light in fiberoptic radiation sensor irradiated by high energy electron beam, " Jpn. J. Appl. Phys., vol. 45, no. 10A, pp. 7980-7982, 2006.
    • (2006) Jpn. J. Appl. Phys. , vol.45 , Issue.10 A , pp. 7980-7982
    • Lee, B.1    Cho, D.H.2    Jang, K.W.3    Chung, S.C.4    Lee, J.W.5    Kim, S.6    Cho, H.7
  • 14
    • 0026555508 scopus 로고
    • Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams
    • A. S. Beddar, T. R. Mackie, and F. H. Attix, "Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams, " Phys. Med. Biol., vol. 37, no. 4, pp. 925-935, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , Issue.4 , pp. 925-935
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 15
    • 36849020434 scopus 로고    scopus 로고
    • Fabrication and characterization of a miniature fiberoptic scintillating detector for electron-beam therapy dosimetry
    • B. Lee, K. W. Jang, D. H. Cho, S. C. Chung, G. R. Tack, G. M. Eom, and J. H. Yi, "Fabrication and characterization of a miniature fiberoptic scintillating detector for electron-beam therapy dosimetry, " J. Korean Phys. Soc., vol. 51, no. 5, pp. 1645-1648, 2007.
    • (2007) J. Korean Phys. Soc. , vol.51 , Issue.5 , pp. 1645-1648
    • Lee, B.1    Jang, K.W.2    Cho, D.H.3    Chung, S.C.4    Tack, G.R.5    Eom, G.M.6    Yi, J.H.7
  • 16
    • 0030168994 scopus 로고    scopus 로고
    • Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry
    • M. R. Arnfield, H. E. Gaballa, R. D. Zwicker, Q. Islam, and R. Schmidt-Ullrich, "Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry, " IEEE Trans. Nucl. Sci., vol. 43, pp. 2077-2084, 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 2077-2084
    • Arnfield, M.R.1    Gaballa, H.E.2    Zwicker, R.D.3    Islam, Q.4    Schmidt-Ullrich, R.5
  • 17
    • 34547678561 scopus 로고    scopus 로고
    • Measurements and elimination of cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry
    • B. Lee, K. W. Jang, D. H. Cho, W. J. Yoo, G. R. Tack, S. C. Chung, S. Kim, and H. Cho, "Measurements and elimination of cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry, " Nucl. Instrum. Phys. Res. A., vol. 579, pp. 344-348, 2007.
    • (2007) Nucl. Instrum. Phys. Res. A. , vol.579 , pp. 344-348
    • Lee, B.1    Jang, K.W.2    Cho, D.H.3    Yoo, W.J.4    Tack, G.R.5    Chung, S.C.6    Kim, S.7    Cho, H.8
  • 18
    • 0034109047 scopus 로고    scopus 로고
    • Dealing with cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams
    • M. A. Clift, R. A. Sutton, and D. V. Webb, "Dealing with cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams, " Phys. Med. Biol., vol. 45, pp. 1165-1182, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1165-1182
    • Clift, M.A.1    Sutton, R.A.2    Webb, D.V.3
  • 19
    • 0027219790 scopus 로고
    • Optical filtering and spectral measurements of radiation induced light in plastic scintillation dosimetry
    • S. F. de Boer, A. S. Beddar, and J. A. Rawlinson, "Optical filtering and spectral measurements of radiation induced light in plastic scintillation dosimetry, " Phys. Med. Biol., vol. 38, pp. 945-958, 1993.
    • (1993) Phys. Med. Biol. , vol.38 , pp. 945-958
    • De Boer, S.F.1    Beddar, A.S.2    Rawlinson, J.A.3
  • 20
    • 0037149989 scopus 로고    scopus 로고
    • A temporal method of avoiding the cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams
    • M. A. Clift, P. N. Johnston, and D. V. Webb, "A temporal method of avoiding the cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams, " Phys. Med. Biol., vol. 47, pp. 1421-33, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1421-33
    • Clift, M.A.1    Johnston, P.N.2    Webb, D.V.3
  • 21
    • 77953919886 scopus 로고    scopus 로고
    • Performance evaluation of one-dimensional fiber-optic radiation sensor for measuring high energy electron beam using a charge-coupled device
    • D. H. Cho, K. W. Jang, W. J. Yoo, S. C. Chung, G. R. Tack, G. M. Eom, B. Lee, H. Cho, and S. Kim, "Performance evaluation of one-dimensional fiber-optic radiation sensor for measuring high energy electron beam using a charge-coupled device, " J. Nucl. Sci. Technol., supplement 5, pp. 477-480, 2008.
    • (2008) J. Nucl. Sci. Technol., Supplement 5 , pp. 477-480
    • Cho, D.H.1    Jang, K.W.2    Yoo, W.J.3    Chung, S.C.4    Tack, G.R.5    Eom, G.M.6    Lee, B.7    Cho, H.8    Kim, S.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.