메뉴 건너뛰기




Volumn 42, Issue 4-5, 2007, Pages 929-932

A fibre optic dosimeter customised for brachytherapy

Author keywords

Brachytherapy; Radiation therapy; Scintillation dosimetry

Indexed keywords

BIOLOGICAL ORGANS; FIBER OPTICS; OPTICAL FIBERS; RADIOTHERAPY; REAL TIME CONTROL; SCINTILLATION;

EID: 34548240206     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2007.02.042     Document Type: Article
Times cited : (32)

References (8)
  • 1
    • 31044441579 scopus 로고    scopus 로고
    • Measurement accuracy and Čerenkov removal for high performance, high spatial resolution scintillation dosimetry
    • Archambault L., Beddar A.S., Gingras L., Roy R., and Beaulieu L. Measurement accuracy and Čerenkov removal for high performance, high spatial resolution scintillation dosimetry. Med. Phys. 33 (2006) 128-135
    • (2006) Med. Phys. , vol.33 , pp. 128-135
    • Archambault, L.1    Beddar, A.S.2    Gingras, L.3    Roy, R.4    Beaulieu, L.5
  • 2
    • 0343776958 scopus 로고    scopus 로고
    • A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy
    • Bambynek M., Fluhs D., Quast U., Wegener D., and Soares C.G. A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy. Med. Phys. 27 (2000) 662-667
    • (2000) Med. Phys. , vol.27 , pp. 662-667
    • Bambynek, M.1    Fluhs, D.2    Quast, U.3    Wegener, D.4    Soares, C.G.5
  • 3
    • 34548270926 scopus 로고    scopus 로고
    • Elsey, J., McKenzie, D.R., Lambert, J., Suchowerska, N., Law, S.H., Fleming, S.C., 2006. Optimal coupling of light from a cylindrical scintillator into an optical fibre, accepted for publication.
  • 6
    • 49049097167 scopus 로고    scopus 로고
    • Law, S.H., Suchowerska, N., McKenzie, D.R., Fleming, S.C., Lin, T., 2006. Čerenkov radiation in optical fibres, submitted for publication.
  • 7
    • 0037423925 scopus 로고    scopus 로고
    • Calibration and validation of a quality assurance system for 90Sr/90Y radiation source trains
    • Rosenthal P., Weber W., Forster A., Orth O., Kohler B., and Seiler F. Calibration and validation of a quality assurance system for 90Sr/90Y radiation source trains. Phys. Med. Biol. 48 (2003) 573-585
    • (2003) Phys. Med. Biol. , vol.48 , pp. 573-585
    • Rosenthal, P.1    Weber, W.2    Forster, A.3    Orth, O.4    Kohler, B.5    Seiler, F.6
  • 8
    • 34548276458 scopus 로고    scopus 로고
    • Valentin, J., 2005. Prevention of high dose rate brachytherapy accidents. ICRP Publication 97.