메뉴 건너뛰기




Volumn 43, Issue 9, 2010, Pages 1731-1737

Valid μ finite element models of vertebral trabecular bone can be obtained using tissue properties measured with nanoindentation under wet conditions

Author keywords

Finite element; Material properties; Micro CT; Nanoindentation; Trabecular bone

Indexed keywords

CONTINUUM LEVEL; CORRELATION COEFFICIENT; CT SCAN; DRY AND WET; EFFECTIVE PROPERTY; FE MODEL; FE-SIMULATION; FINITE ELEMENT; FINITE ELEMENT MODELS; FINITE ELEMENT SIMULATIONS; LINEAR ELASTIC; MACROSCOPIC MATERIALS; MATERIAL PROPERTIES; MECHANICAL COMPRESSION; MICRO CT; MOIST CONDITIONS; NON DESTRUCTIVE; PUBLIC HEALTH; SURGICAL INTERVENTIONS; TENSION AND COMPRESSION; TESTING CONDITIONS; TISSUE MODULUS; TISSUE PROPERTIES; TORSION TESTS; TRABECULAR BONES; VERTEBRAL FRACTURES; VERTEBRAL TRABECULAR BONE; VERTEBROPLASTY; WET CONDITIONS; WET TISSUES;

EID: 77953536589     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2010.02.026     Document Type: Article
Times cited : (82)

References (37)
  • 4
    • 61749089933 scopus 로고    scopus 로고
    • The influence of boundary conditions and loading mode on high-resolution finite element-computed trabecular tissue properties
    • Bevill G., Eswaran S.K., Farahmand F., Keaveny T.M. The influence of boundary conditions and loading mode on high-resolution finite element-computed trabecular tissue properties. Bone 2009, 44(4):573-578.
    • (2009) Bone , vol.44 , Issue.4 , pp. 573-578
    • Bevill, G.1    Eswaran, S.K.2    Farahmand, F.3    Keaveny, T.M.4
  • 5
    • 61749090850 scopus 로고    scopus 로고
    • Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution
    • Bevill G., Keaveny T.M. Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution. Bone 2009, 44(4):579-584.
    • (2009) Bone , vol.44 , Issue.4 , pp. 579-584
    • Bevill, G.1    Keaveny, T.M.2
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1(8476):307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 4444349593 scopus 로고    scopus 로고
    • Nanoindentation of bone: comparison of specimens tested in liquid and embedded in polymethylmethacrylate
    • Bushby A.J., Ferguson V.L., Boyde A. Nanoindentation of bone: comparison of specimens tested in liquid and embedded in polymethylmethacrylate. Journal of Materials Research 2004, 19(1):249-259.
    • (2004) Journal of Materials Research , vol.19 , Issue.1 , pp. 249-259
    • Bushby, A.J.1    Ferguson, V.L.2    Boyde, A.3
  • 8
    • 35448949602 scopus 로고    scopus 로고
    • Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation
    • Chevalier Y., Pahr D., Allmer H., Charlebois M., Zysset P. Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation. Journal of Biomechanics 2007, 40(15):3333-3340.
    • (2007) Journal of Biomechanics , vol.40 , Issue.15 , pp. 3333-3340
    • Chevalier, Y.1    Pahr, D.2    Allmer, H.3    Charlebois, M.4    Zysset, P.5
  • 9
    • 0141638627 scopus 로고    scopus 로고
    • Finite element models predict in-vitro vertebral body compressive strength better than quantitative computed tomography
    • Crawford P.R., Cann C.E., Keaveny T.E. Finite element models predict in-vitro vertebral body compressive strength better than quantitative computed tomography. Bone 2003, 33(4):744-750.
    • (2003) Bone , vol.33 , Issue.4 , pp. 744-750
    • Crawford, P.R.1    Cann, C.E.2    Keaveny, T.E.3
  • 10
    • 0343067093 scopus 로고    scopus 로고
    • Mechanical characterization in shear of human femoral cancellous bone: torsion and shear tests
    • Garnier K.B., Dumas R., Rumelhart C., Arlot M.E. Mechanical characterization in shear of human femoral cancellous bone: torsion and shear tests. Medical Engineering & Physics 1999, 21(9):641-649.
    • (1999) Medical Engineering & Physics , vol.21 , Issue.9 , pp. 641-649
    • Garnier, K.B.1    Dumas, R.2    Rumelhart, C.3    Arlot, M.E.4
  • 12
    • 0141453854 scopus 로고    scopus 로고
    • How is the indentation modulus of bone tissue related to its macroscopic elastic response? A validation study
    • Hengsberger S., Enstroem J., Peyrin F., Zysset P.K. How is the indentation modulus of bone tissue related to its macroscopic elastic response? A validation study. Journal of Biomechanics 2003, 36(10):1503-1509.
    • (2003) Journal of Biomechanics , vol.36 , Issue.10 , pp. 1503-1509
    • Hengsberger, S.1    Enstroem, J.2    Peyrin, F.3    Zysset, P.K.4
  • 13
    • 0036138301 scopus 로고    scopus 로고
    • Nanoindentation discriminates the elastic properties of individual human bone lamellae under dry and physiological conditions
    • Hengsberger S., Kulik A., Zysset P.K. Nanoindentation discriminates the elastic properties of individual human bone lamellae under dry and physiological conditions. Bone 2002, 30(1):178-184.
    • (2002) Bone , vol.30 , Issue.1 , pp. 178-184
    • Hengsberger, S.1    Kulik, A.2    Zysset, P.K.3
  • 14
    • 30344467213 scopus 로고    scopus 로고
    • An application of nanoindentation technique to measure bone tissue lamellae properties
    • Hoffler C.E., Guo X.E., Zysset P.K., Goldstein S.A. An application of nanoindentation technique to measure bone tissue lamellae properties. Journal of Biomechanical Engineering 2005, 127(7):1046-1053.
    • (2005) Journal of Biomechanical Engineering , vol.127 , Issue.7 , pp. 1046-1053
    • Hoffler, C.E.1    Guo, X.E.2    Zysset, P.K.3    Goldstein, S.A.4
  • 16
  • 18
    • 0032123274 scopus 로고    scopus 로고
    • Yield strain behaviour of trabecular bone
    • Kopperdahl D.L., Keaveny T.M. Yield strain behaviour of trabecular bone. Journal of Biomechanics 1998, 31(7):601-608.
    • (1998) Journal of Biomechanics , vol.31 , Issue.7 , pp. 601-608
    • Kopperdahl, D.L.1    Keaveny, T.M.2
  • 19
    • 52449112409 scopus 로고    scopus 로고
    • The use of nanoindentation for characterizing the properties of mineralized hard tissues: state-of-the art review
    • Lewis G., Nyman J.S. The use of nanoindentation for characterizing the properties of mineralized hard tissues: state-of-the art review. Journal of Biomedical Materials Research. Part B, Applied Biomaterials 2008, 288-303(1):87.
    • (2008) Journal of Biomedical Materials Research. Part B, Applied Biomaterials , Issue.1 , pp. 87
    • Lewis, G.1    Nyman, J.S.2
  • 20
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin L.K. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989, 45(1):255-268.
    • (1989) Biometrics , vol.45 , Issue.1 , pp. 255-268
    • Lin, L.K.1
  • 21
    • 0038673390 scopus 로고    scopus 로고
    • Trabecular bone modulus-density relationships depend on anatomic site
    • Morgan E.F., Bayraktar H.H., Keaveny T.M. Trabecular bone modulus-density relationships depend on anatomic site. Journal of Biomechanics 2003, 36(7):897-904.
    • (2003) Journal of Biomechanics , vol.36 , Issue.7 , pp. 897-904
    • Morgan, E.F.1    Bayraktar, H.H.2    Keaveny, T.M.3
  • 22
    • 0011784755 scopus 로고
    • (Eds.), Torsion of a Round Bar. The Stress-Strain Curve in Shear. 21 McGraw-Hill Book Company, Inc. New York, Toronto and London.
    • Nadai, A., Phelps, R.H. (Eds.), 1950. Torsion of a Round Bar. The Stress-Strain Curve in Shear. 21 McGraw-Hill Book Company, Inc. New York, Toronto and London, pp. 347-352.
    • (1950) , pp. 347-352
    • Nadai, A.1    Phelps, R.H.2
  • 23
    • 0033811123 scopus 로고    scopus 로고
    • High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone
    • Niebur G.L., Feldstein M.J., Yuen J.C., Chen T.J., Keaveny T.M. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone. Journal of Biomechanics 2000, 33(12):1575-1583.
    • (2000) Journal of Biomechanics , vol.33 , Issue.12 , pp. 1575-1583
    • Niebur, G.L.1    Feldstein, M.J.2    Yuen, J.C.3    Chen, T.J.4    Keaveny, T.M.5
  • 24
    • 0026875935 scopus 로고
    • An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments
    • Oliver W., Pharr G. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. Journal of Materials Research 1992, 7(6):1564-1583.
    • (1992) Journal of Materials Research , vol.7 , Issue.6 , pp. 1564-1583
    • Oliver, W.1    Pharr, G.2
  • 25
    • 77953542173 scopus 로고    scopus 로고
    • R Development Core Team. R: A Language and Environment for Statistical Computing. R Foundation for Statistical Computing, Vienna, Austria, ISBN 3-900051-07-0.
    • R Development Core Team, 2008. R: A Language and Environment for Statistical Computing. R Foundation for Statistical Computing, Vienna, Austria, ISBN 3-900051-07-0. http://www.R-project.org.
    • (2008)
  • 27
    • 0033119284 scopus 로고    scopus 로고
    • Elastic properties of microstructural components of human bone tissue as measured by nanoindentation
    • Rho J., Tsui T.Y., Pharr G.M. Elastic properties of microstructural components of human bone tissue as measured by nanoindentation. Journal of Biomedical Materials Research 1999, 45(1):48-58.
    • (1999) Journal of Biomedical Materials Research , vol.45 , Issue.1 , pp. 48-58
    • Rho, J.1    Tsui, T.Y.2    Pharr, G.M.3
  • 28
    • 0031260276 scopus 로고    scopus 로고
    • Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
    • Rho J.-Y., Tsui T.Y., Pharr G.M. Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. Biomaterials 1997, 20(18):1325-1330.
    • (1997) Biomaterials , vol.20 , Issue.18 , pp. 1325-1330
    • Rho, J.-Y.1    Tsui, T.Y.2    Pharr, G.M.3
  • 30
    • 0030561004 scopus 로고    scopus 로고
    • Direct mechanics assessment of elastic constants of elastic symmetries and properties of trabecular bone architecture
    • Rietbergen B.v., Odgaard A., Kabel J., Huiskes R. Direct mechanics assessment of elastic constants of elastic symmetries and properties of trabecular bone architecture. Journal of Biomechanics 1996, 29(12):1653-1657.
    • (1996) Journal of Biomechanics , vol.29 , Issue.12 , pp. 1653-1657
    • Rietbergen, B.1    Odgaard, A.2    Kabel, J.3    Huiskes, R.4
  • 31
    • 0028936206 scopus 로고
    • A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models
    • Rietbergen B.v., Weinans H., Huiskes R., Odgaardt A. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. Journal of Bioimechanics 1995, 28(1):69-81.
    • (1995) Journal of Bioimechanics , vol.28 , Issue.1 , pp. 69-81
    • Rietbergen, B.1    Weinans, H.2    Huiskes, R.3    Odgaardt, A.4
  • 33
    • 0033080555 scopus 로고    scopus 로고
    • Mechanical and morphological variation of the lumbar vertebral cortical and trabecular bone
    • Roy M.E., Rho J., Tsui T.Y., Evans N.D., Pharr G.M. Mechanical and morphological variation of the lumbar vertebral cortical and trabecular bone. Journal of Biomedical Materials Research 1999, 44(2):191-197.
    • (1999) Journal of Biomedical Materials Research , vol.44 , Issue.2 , pp. 191-197
    • Roy, M.E.1    Rho, J.2    Tsui, T.Y.3    Evans, N.D.4    Pharr, G.M.5
  • 34
    • 0033119356 scopus 로고    scopus 로고
    • The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques
    • Turner C.H., Rho J., Takano Y., Tsui T.Y., Pharr G.M. The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques. Journal of Biomechanics 1999, 32(4):437-441.
    • (1999) Journal of Biomechanics , vol.32 , Issue.4 , pp. 437-441
    • Turner, C.H.1    Rho, J.2    Takano, Y.3    Tsui, T.Y.4    Pharr, G.M.5
  • 35
  • 36
    • 74349084412 scopus 로고    scopus 로고
    • Rehydration of vertebral trabecular bone: influences on its anisotropy, its stiffness and the indentation work with a view to age, gender and vertebral level
    • Wolfram U., Wilke H.-J., Zysset P.K. Rehydration of vertebral trabecular bone: influences on its anisotropy, its stiffness and the indentation work with a view to age, gender and vertebral level. Bone 2010, 46(2):348-354.
    • (2010) Bone , vol.46 , Issue.2 , pp. 348-354
    • Wolfram, U.1    Wilke, H.-J.2    Zysset, P.K.3
  • 37
    • 0033213750 scopus 로고    scopus 로고
    • Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur
    • Zysset P.K., Guo E.X., Hoffler E.C., Moore K.E., Goldstein S.A. Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur. Journal of Biomechanics 1999, 32(10):1005-1012.
    • (1999) Journal of Biomechanics , vol.32 , Issue.10 , pp. 1005-1012
    • Zysset, P.K.1    Guo, E.X.2    Hoffler, E.C.3    Moore, K.E.4    Goldstein, S.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.