메뉴 건너뛰기




Volumn 126, Issue 6, 2004, Pages 677-684

The modified super-ellipsoid yield criterion for human trabecular bone

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; COMPUTERIZED TOMOGRAPHY; FAILURE (MECHANICAL); FINITE ELEMENT METHOD; LOADS (FORCES); MATHEMATICAL MODELS; PARALLEL PROCESSING SYSTEMS; STRAIN; SUPERCOMPUTERS;

EID: 14344251491     PISSN: 01480731     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.1763177     Document Type: Article
Times cited : (90)

References (38)
  • 1
    • 0025836580 scopus 로고
    • Fracture prediction for the proximal femur using finite-element models: Part I-Linear analysis
    • Lotz, J. C., Cheal, E. J., and Hayes, W. C., 1991, "Fracture prediction for the proximal femur using finite-element models: Part I-Linear analysis," J. Biomech. Eng., 113, pp. 353-360.
    • (1991) J. Biomech. Eng. , vol.113 , pp. 353-360
    • Lotz, J.C.1    Cheal, E.J.2    Hayes, W.C.3
  • 2
    • 0025790268 scopus 로고
    • Fracture prediction for the proximal femur using finite-element models: Part II-Nonlinear analysis
    • Lotz, J. C., Cheal, E. J., and Hayes, W. C., 1991, "Fracture prediction for the proximal femur using finite-element models: Part II-Nonlinear analysis," J. Biomech. Eng., 113, pp. 361-365.
    • (1991) J. Biomech. Eng. , vol.113 , pp. 361-365
    • Lotz, J.C.1    Cheal, E.J.2    Hayes, W.C.3
  • 3
    • 0022356106 scopus 로고
    • Stress analysis of a condylar knee tibial component: Influence of metaphyseal shell properties and cement injection depth
    • Cheal, E. J., Hayes, W. C., Lee, C. H., Snyder, B. D., and Miller, J., 1985, "Stress analysis of a condylar knee tibial component: influence of metaphyseal shell properties and cement injection depth," J. Orthop. Res., 3, pp. 424-434.
    • (1985) J. Orthop. Res. , vol.3 , pp. 424-434
    • Cheal, E.J.1    Hayes, W.C.2    Lee, C.H.3    Snyder, B.D.4    Miller, J.5
  • 4
    • 0033988428 scopus 로고    scopus 로고
    • Prediction of femoral fracture load using finite element models: An examination of stress- and strain-based failure theories
    • Keyak, J. H., and Rossi, S. A., 2000, "Prediction of femoral fracture load using finite element models: an examination of stress- and strain-based failure theories," J. Biomech., 33, pp. 209-214.
    • (2000) J. Biomech. , vol.33 , pp. 209-214
    • Keyak, J.H.1    Rossi, S.A.2
  • 5
    • 0033213780 scopus 로고    scopus 로고
    • Femoral strength is better predicted by finite-element models than QCT and DXA
    • Cody, D. D., Gross, G. J., Hou, F. J., Spencer, H. J., Goldstein, S. A., and Fyhrie, D. P., 1999, "Femoral strength is better predicted by finite-element models than QCT and DXA," J. Biomech., 32, pp. 1013-1020.
    • (1999) J. Biomech. , vol.32 , pp. 1013-1020
    • Cody, D.D.1    Gross, G.J.2    Hou, F.J.3    Spencer, H.J.4    Goldstein, S.A.5    Fyhrie, D.P.6
  • 6
    • 13344280349 scopus 로고    scopus 로고
    • The effect of impact direction on the structural capacity of the proximal femur during falls
    • Ford, C. M., Keaveny, T. M., and Hayes, W. C., 1996, "The effect of impact direction on the structural capacity of the proximal femur during falls," J. Bone Miner. Res., 11, pp. 377-383.
    • (1996) J. Bone Miner. Res. , vol.11 , pp. 377-383
    • Ford, C.M.1    Keaveny, T.M.2    Hayes, W.C.3
  • 7
    • 0035879306 scopus 로고    scopus 로고
    • Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty
    • Liebschner, M. A. K., Rosenberg, W. S., and Keaveny, T. M., 2001, "Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty," Spine, 26, pp. 1547-1554.
    • (2001) Spine , vol.26 , pp. 1547-1554
    • Liebschner, M.A.K.1    Rosenberg, W.S.2    Keaveny, T.M.3
  • 8
    • 0033197583 scopus 로고    scopus 로고
    • Effect of local density changes on the failure load of the proximal femur
    • Oden, Z. M., Selvitelli, D. M., and Bouxsein, M. L., 1999, "Effect of local density changes on the failure load of the proximal femur," J. Orthop. Res., 17, pp. 661-667.
    • (1999) J. Orthop. Res. , vol.17 , pp. 661-667
    • Oden, Z.M.1    Selvitelli, D.M.2    Bouxsein, M.L.3
  • 9
    • 0028502929 scopus 로고
    • Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus
    • Keaveny, T. M., Wachtel, E. F., Ford, C. M., and Hayes, W. C., 1994, "Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus," J. Biomech., 27, pp. 1137-1146.
    • (1994) J. Biomech. , vol.27 , pp. 1137-1146
    • Keaveny, T.M.1    Wachtel, E.F.2    Ford, C.M.3    Hayes, W.C.4
  • 10
    • 0035055590 scopus 로고    scopus 로고
    • Dependence of yield strain of human trabecular bone on anatomic site
    • Morgan, E. F., and Keaveny, T. M., 2001, "Dependence of yield strain of human trabecular bone on anatomic site," J. Biomech., 34, pp. 569-577.
    • (2001) J. Biomech. , vol.34 , pp. 569-577
    • Morgan, E.F.1    Keaveny, T.M.2
  • 11
    • 0022778530 scopus 로고
    • Fabric dependence of an anisotropic strength criterion
    • Cowin, S. C., 1986, "Fabric dependence of an anisotropic strength criterion," Mech. Mater., 5, pp. 251-260.
    • (1986) Mech. Mater. , vol.5 , pp. 251-260
    • Cowin, S.C.1
  • 12
    • 0014974615 scopus 로고
    • A general theory for strength of anisotropic materials
    • Tsai, S., and Wu, E., 1971, "A general theory for strength of anisotropic materials," J. Comp. Mat., 5, pp. 58-80.
    • (1971) J. Comp. Mat. , vol.5 , pp. 58-80
    • Tsai, S.1    Wu, E.2
  • 13
    • 0016360661 scopus 로고
    • Phenomenological anisotropic failure criterion
    • G. Sendecky, ed., Academic Press, New York
    • Wu, E., 1974, "Phenomenological anisotropic failure criterion.," Mechanics of Composite Materials, G. Sendecky, ed., Academic Press, New York, pp. 353-431.
    • (1974) Mechanics of Composite Materials , pp. 353-431
    • Wu, E.1
  • 14
    • 0033083631 scopus 로고    scopus 로고
    • Application of the Tsai-Wu quadratic multiaxial failure criterion to bovine trabecular bone
    • Keaveny, T. M., Wachtel, E. F., Zadesky, S. P., and Arramon, Y. P., 1999, "Application of the Tsai-Wu quadratic multiaxial failure criterion to bovine trabecular bone," J. Biomech. Eng., 121, pp. 99-107.
    • (1999) J. Biomech. Eng. , vol.121 , pp. 99-107
    • Keaveny, T.M.1    Wachtel, E.F.2    Zadesky, S.P.3    Arramon, Y.P.4
  • 15
    • 0036960680 scopus 로고    scopus 로고
    • Biaxial failure behavior of bovine tibial trabecular bone
    • Niebur, G. L., Feldstein, M. J., and Keaveny, T. M., 2002, "Biaxial failure behavior of bovine tibial trabecular bone," J. Biomech. Eng., 124, pp. 699-705.
    • (2002) J. Biomech. Eng. , vol.124 , pp. 699-705
    • Niebur, G.L.1    Feldstein, M.J.2    Keaveny, T.M.3
  • 17
    • 0015586839 scopus 로고
    • Multiaxial-stress studies on rigid polyurethane foam
    • Zaslawsky, M., 1973, "Multiaxial-stress studies on rigid polyurethane foam," Exp. Mech., 2, pp. 70-76.
    • (1973) Exp. Mech. , vol.2 , pp. 70-76
    • Zaslawsky, M.1
  • 18
    • 0024944309 scopus 로고
    • Failure surfaces for cellular materials under multiaxial loads-I. Modelling
    • Gibson, L. J., Ashby, M. F., Zhang, J., and Triantafillou, T. C., 1989, "Failure surfaces for cellular materials under multiaxial loads-I. Modelling," Int. J. Mech. Sci., 31, pp. 635-663.
    • (1989) Int. J. Mech. Sci. , vol.31 , pp. 635-663
    • Gibson, L.J.1    Ashby, M.F.2    Zhang, J.3    Triantafillou, T.C.4
  • 19
    • 0024925041 scopus 로고
    • Failure surfaces for cellular materials under multiaxial loads-II. Comparison of models with experiment
    • Triantafillou, T. C., Zhang, J., Shercliff, T. L., Gibson, L. J., and Ashby, M. F., 1989, "Failure surfaces for cellular materials under multiaxial loads-II. Comparison of models with experiment," Int. J. Mech. Sci., 31, pp. 665-678.
    • (1989) Int. J. Mech. Sci. , vol.31 , pp. 665-678
    • Triantafillou, T.C.1    Zhang, J.2    Shercliff, T.L.3    Gibson, L.J.4    Ashby, M.F.5
  • 20
    • 0032746294 scopus 로고    scopus 로고
    • A cellular solid criterion for predicting the axial-shear failure properties of trabecular bone
    • Fenech, C. M., and Keaveny, T. M., 1999, "A cellular solid criterion for predicting the axial-shear failure properties of trabecular bone.," J. Biomech. Eng., 121, pp. 414-422.
    • (1999) J. Biomech. Eng. , vol.121 , pp. 414-422
    • Fenech, C.M.1    Keaveny, T.M.2
  • 21
    • 4544239296 scopus 로고    scopus 로고
    • Mechanisms of uniformity of yield strains for trabecular bone
    • In Press
    • Bayraktar, H. H., and Keaveny, T. M., 2004, "Mechanisms of uniformity of yield strains for trabecular bone," J. Biomech., In Press.
    • (2004) J. Biomech.
    • Bayraktar, H.H.1    Keaveny, T.M.2
  • 22
    • 3242655549 scopus 로고    scopus 로고
    • Contribution of inter-site variations in architecture to trabecular bone apparent yield strain
    • In Press
    • Morgan, E. F., Bayraktar, H. H., Yeh, O. C., and Keaveny, T. M., 2004, "Contribution of inter-site variations in architecture to trabecular bone apparent yield strain," J. Biomech., In Press.
    • (2004) J. Biomech.
    • Morgan, E.F.1    Bayraktar, H.H.2    Yeh, O.C.3    Keaveny, T.M.4
  • 23
    • 0002816293 scopus 로고    scopus 로고
    • Mechanical properties of cortical bone and cancellous tissue
    • S. C. Cowin, ed., CRC Press, Boca Raton
    • Guo, X. E., 2001, "Mechanical properties of cortical bone and cancellous tissue," Bone Mechanics Handbook, S. C. Cowin, ed., CRC Press, Boca Raton, pp. 10.11-10.23.
    • (2001) Bone Mechanics Handbook
    • Guo, X.E.1
  • 24
    • 0347627538 scopus 로고    scopus 로고
    • Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
    • Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G., Wong, E. K., and Keaveny, T. M., 2004, "Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue," J. Biomech., 37, pp. 27-35.
    • (2004) J. Biomech. , vol.37 , pp. 27-35
    • Bayraktar, H.H.1    Morgan, E.F.2    Niebur, G.L.3    Morris, G.4    Wong, E.K.5    Keaveny, T.M.6
  • 25
    • 0030868755 scopus 로고    scopus 로고
    • Three-dimensional imaging of trabecular bone using the computer numerically controlled milling technique
    • N.Y.
    • Beck, J. D., Canfield, B. L., Haddock, S. M., Chen, T. J. H., Kothari, M., and Keaveny, T. M., 1997, "Three-dimensional imaging of trabecular bone using the computer numerically controlled milling technique," Bone (N.Y.), 21, pp. 281-287.
    • (1997) Bone , vol.21 , pp. 281-287
    • Beck, J.D.1    Canfield, B.L.2    Haddock, S.M.3    Chen, T.J.H.4    Kothari, M.5    Keaveny, T.M.6
  • 26
    • 0030071062 scopus 로고    scopus 로고
    • A microtomographic system for the nondestructive evaluation of bone architecture
    • Rüegsegger, P., Koller, B., and Müller, R., 1996, "A microtomographic system for the nondestructive evaluation of bone architecture," Calcif. Tissue Int., 58, pp. 24-29.
    • (1996) Calcif. Tissue Int. , vol.58 , pp. 24-29
    • Rüegsegger, P.1    Koller, B.2    Müller, R.3
  • 27
    • 0033811123 scopus 로고    scopus 로고
    • High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone
    • Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., and Keaveny, T. M., 2000, "High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone," J. Biomech., 33, pp. 1575-1583.
    • (2000) J. Biomech. , vol.33 , pp. 1575-1583
    • Niebur, G.L.1    Feldstein, M.J.2    Yuen, J.C.3    Chen, T.J.4    Keaveny, T.M.5
  • 28
    • 0033294444 scopus 로고    scopus 로고
    • Convergence behavior of high-resolution finite element models of trabecular bone
    • Niebur, G. L., Yuen, J. C., Hsia, A. C., and Keaveny, T. M., 1999, "Convergence behavior of high-resolution finite element models of trabecular bone," J. Biomech. Eng., 121, pp. 629-635.
    • (1999) J. Biomech. Eng. , vol.121 , pp. 629-635
    • Niebur, G.L.1    Yuen, J.C.2    Hsia, A.C.3    Keaveny, T.M.4
  • 29
    • 0030561004 scopus 로고    scopus 로고
    • Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture
    • Van Rietbergen, B., Odgaard, A., Kabel, J., and Huiskes, R., 1996, "Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture," J. Biomech., 29, pp. 1653-1657.
    • (1996) J. Biomech. , vol.29 , pp. 1653-1657
    • Van Rietbergen, B.1    Odgaard, A.2    Kabel, J.3    Huiskes, R.4
  • 30
    • 0019346818 scopus 로고
    • Superquadratics and angle-preserving transformations
    • Barr, A. H., 1981, "Superquadratics and angle-preserving transformations," IEEE Comput. Graphics and Appl., 1, pp. 11-23.
    • (1981) IEEE Comput. Graphics and Appl. , vol.1 , pp. 11-23
    • Barr, A.H.1
  • 31
    • 0033047422 scopus 로고    scopus 로고
    • Direct three-dimensional morphometric analysis of human cancellous bone: Microstructural data from spine, femur, iliac crest, and calcaneus
    • Hildebrand, T., Laib, A., Müller, R., Dequeker, J., and Rüegsegger, P., 1999, "Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus," J. Bone Miner. Res., 14, pp. 1167-1174.
    • (1999) J. Bone Miner. Res. , vol.14 , pp. 1167-1174
    • Hildebrand, T.1    Laib, A.2    Müller, R.3    Dequeker, J.4    Rüegsegger, P.5
  • 32
    • 0032467389 scopus 로고    scopus 로고
    • Micro-compression: A novel technique for the nondestructive assessment of local bone failure
    • Müller, R., Gerber, S. C., and Hayes, W. C., 1998, "Micro-compression: a novel technique for the nondestructive assessment of local bone failure," Technol. Health Care, 6, pp. 433-444.
    • (1998) Technol. Health Care , vol.6 , pp. 433-444
    • Müller, R.1    Gerber, S.C.2    Hayes, W.C.3
  • 33
    • 0141638690 scopus 로고    scopus 로고
    • On the importance of geometric nonlinearity in finite-element simulations of trabecular bone failure
    • N.Y.
    • Stölken, J. S., and Kinney, J. H., 2003, "On the importance of geometric nonlinearity in finite-element simulations of trabecular bone failure," Bone (N.Y.), 33, pp. 494-504.
    • (2003) Bone , vol.33 , pp. 494-504
    • Stölken, J.S.1    Kinney, J.H.2
  • 34
    • 0021085023 scopus 로고
    • Multiaxial strength characteristics of trabecular bone
    • Stone, J. L., Beaupre, G. S., and Hayes, W. C., 1983, "Multiaxial strength characteristics of trabecular bone," J. Biomech., 16, pp. 743-752.
    • (1983) J. Biomech. , vol.16 , pp. 743-752
    • Stone, J.L.1    Beaupre, G.S.2    Hayes, W.C.3
  • 35
    • 0024711963 scopus 로고
    • Yield behavior of bovine cancellous bone
    • Turner, C. H., 1989, "Yield behavior of bovine cancellous bone," J. Biomech. Eng., 111, pp. 256-260.
    • (1989) J. Biomech. Eng. , vol.111 , pp. 256-260
    • Turner, C.H.1
  • 36
  • 38
    • 0037145312 scopus 로고    scopus 로고
    • Evaluation of three unstructured multigrid methods on 3D finite element problems in solid mechanics
    • Adams, M., 2002, "Evaluation of three unstructured multigrid methods on 3D finite element problems in solid mechanics," Int. J. Numer. Methods Eng., 55, pp. 519-534.
    • (2002) Int. J. Numer. Methods Eng. , vol.55 , pp. 519-534
    • Adams, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.