메뉴 건너뛰기




Volumn 57, Issue 6, 2010, Pages 1296-1310

Indicator dilution models for the quantification of microvascular blood flow with bolus administration of ultrasound contrast agents

Author keywords

[No Author keywords available]

Indexed keywords

AREA UNDER THE CURVES; BEST FIT; BLOOD FLOW; CLINICAL APPLICATION; CONTRAST ENHANCED ULTRASOUND; DILUTION METHOD; DILUTION MODELS; DILUTION TECHNIQUE; DRIFT MODEL; EXPERIMENTAL DATA; GAMMA VARIATE FUNCTIONS; HEMODYNAMIC PARAMETERS; IMAGE DATA; LIVER METASTASIS; LOG-NORMAL FUNCTIONS; MEAN TRANSIT TIME; MICROVASCULAR; NORMAL FUNCTION; PEAK INTENSITY; THERAPY MONITORING; TIME-INTENSITY CURVES; ULTRASOUND CONTRAST AGENT;

EID: 77953255183     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2010.1550     Document Type: Article
Times cited : (131)

References (65)
  • 1
    • 33751176083 scopus 로고    scopus 로고
    • Ultrasound contrast agents: An overview
    • Dec.
    • D. Cosgrove, "Ultrasound contrast agents: An overview," Eur. J. Radiol., vol.60, pp. 324-330, Dec. 2006.
    • (2006) Eur. J. Radiol. , vol.60 , pp. 324-330
    • Cosgrove, D.1
  • 5
    • 77953278388 scopus 로고    scopus 로고
    • Future directions-New developments in ultrasound
    • J. de la Rosette, M. Harisinghani, M. Manyak, and H. Wijkstra, Eds., London, UK: Springer-Verlag
    • G. A. Schwartz and M. A. Averkiou, "Future directions-New developments in ultrasound," in Imaging in Oncological Urology, J. de la Rosette, M. Harisinghani, M. Manyak, and H. Wijkstra, Eds., London, UK: Springer-Verlag, 2009, pp. 373-379.
    • (2009) Imaging in Oncological Urology , pp. 373-379
    • Schwartz, G.A.1    Averkiou, M.A.2
  • 6
    • 31844433217 scopus 로고    scopus 로고
    • Potential value of contrast-enhanced intraoperative ultrasonography during partial hepatectomy for metastases: An essential investigation before resection?
    • Feb.
    • E. Leen, P. Ceccotti, S. J. Moug, P. Glen, J. MacQuarrie, W. J. Angerson, T. Albrecht, J. Hohmann, A. Oldenburg, J. P. Ritz, and P. G. Horgan, "Potential value of contrast-enhanced intraoperative ultrasonography during partial hepatectomy for metastases: An essential investigation before resection?" Ann. Surg., vol.243, no.2, pp. 236-240, Feb., 2006.
    • (2006) Ann. Surg. , vol.243 , Issue.2 , pp. 236-240
    • Leen, E.1    Ceccotti, P.2    Moug, S.J.3    Glen, P.4    MacQuarrie, J.5    Angerson, W.J.6    Albrecht, T.7    Hohmann, J.8    Oldenburg, A.9    Ritz, J.P.10    Horgan, P.G.11
  • 7
    • 0031648094 scopus 로고    scopus 로고
    • Liver vascular transit time analyzed with dynamic hepatic venography with bolus injections of an US contrast agent: Early experience in seven patients with metastases
    • Dec.
    • M. J. Blomley, T. Albrecht, D. O. Cosgrove, V. Jayaram, R. J. Eckersley, N. Patel, S. Taylor-Robinson, A. Bauer, and R. Schlief, "Liver vascular transit time analyzed with dynamic hepatic venography with bolus injections of an US contrast agent: Early experience in seven patients with metastases," Radiology, vol.209, no.3, pp. 862-866, Dec. 1998.
    • (1998) Radiology , vol.209 , Issue.3 , pp. 862-866
    • Blomley, M.J.1    Albrecht, T.2    Cosgrove, D.O.3    Jayaram, V.4    Eckersley, R.J.5    Patel, N.6    Taylor-Robinson, S.7    Bauer, A.8    Schlief, R.9
  • 9
    • 0036604402 scopus 로고    scopus 로고
    • Quantitative microbubble enhanced transrectal ultrasound as a tool for monitoring hormonal treatment of prostate carcinoma
    • Jun.
    • R. J. Eckersley, J. P. Michiel Sedelaar, M. J. K. Blomley, H. Wijkstra, N. M. deSouza, D. O. Cosgrove, and J. J. M. C. H. de la Rosette, "Quantitative microbubble enhanced transrectal ultrasound as a tool for monitoring hormonal treatment of prostate carcinoma," Prostate, vol.51, no.4, pp. 256-267, Jun. 2002.
    • (2002) Prostate , vol.51 , Issue.4 , pp. 256-267
    • Eckersley, R.J.1    Michiel Sedelaar, J.P.2    Blomley, M.J.K.3    Wijkstra, H.4    Desouza, N.M.5    Cosgrove, D.O.6    De La Rosette, J.J.M.C.H.7
  • 10
    • 33749441993 scopus 로고    scopus 로고
    • The kidney: Imaging with microbubble contrast agents
    • Mar.
    • J. M. Correas, M. Claudon, F. Tranquart, and A. O. Helenon, "The kidney: Imaging with microbubble contrast agents," Ultrasound Q., vol.22, no.1, pp. 53-66, Mar. 2006.
    • (2006) Ultrasound Q , vol.22 , Issue.1 , pp. 53-66
    • Correas, J.M.1    Claudon, M.2    Tranquart, F.3    Helenon, A.O.4
  • 12
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasoundinduced destruction of microbubbles administered as a constant venous infusion
    • Feb.
    • K. Wei, A. R. Jayaweera, S. Firoozan, A. Linka, D. M. Skypa, and S. Kaul, "Quantification of myocardial blood flow with ultrasoundinduced destruction of microbubbles administered as a constant venous infusion," Circulation, vol.97, no.5, pp. 473-483, Feb. 1998.
    • (1998) Circulation , vol.97 , Issue.5 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skypa, D.M.5    Kaul, S.6
  • 13
    • 84939082594 scopus 로고
    • Researches on the circulation time and on the influences which affect it. IV. The output of the heart
    • G. N. Stewart, "Researches on the circulation time and on the influences which affect it. IV. The output of the heart," J. Physiol., vol.22, pp. 159-183, 1897.
    • (1897) J. Physiol. , vol.22 , pp. 159-183
    • Stewart, G.N.1
  • 14
    • 0344437373 scopus 로고
    • Uber die Verteilung des Blutes vom linken Herzen zwischen dem Herzen und dem ubrigen Organismus
    • V. Henriques, "Uber die Verteilung des Blutes vom linken Herzen zwischen dem Herzen und dem ubrigen Organismus," Biochem. Z., vol.56, pp. 230-248, 1913.
    • (1913) Biochem. Z. , vol.56 , pp. 230-248
    • Henriques, V.1
  • 15
    • 0001669568 scopus 로고
    • Simultaneous determination of the pulmonary and systemic circulation times in man and of a figure related to cardiac output
    • Mar.
    • W. F. Hamilton, J. W. Moore, J. M. Kinsman, and R. G. Spurling, "Simultaneous determination of the pulmonary and systemic circulation times in man and of a figure related to cardiac output," Am. J. Physiol., vol.84, pp. 338-344, Mar. 1928.
    • (1928) Am. J. Physiol. , vol.84 , pp. 338-344
    • Hamilton, W.F.1    Moore, J.W.2    Kinsman, J.M.3    Spurling, R.G.4
  • 16
    • 0000138437 scopus 로고
    • Studies of the circulation: VI. Further analysis of the injection method and of changes of hemodynamic under physiological conditions
    • W. F. Hamilton, J. W. Moore, J. M. Kinsman, and R. G. Spurling, "Studies of the circulation: VI. Further analysis of the injection method and of changes of hemodynamic under physiological conditions," Am. J. Physiol., vol.99, no.3, pp. 534-551, 1932.
    • (1932) Am. J. Physiol. , vol.99 , Issue.3 , pp. 534-551
    • Hamilton, W.F.1    Moore, J.W.2    Kinsman, J.M.3    Spurling, R.G.4
  • 17
    • 51249193733 scopus 로고
    • Theory of the measurement of blood flow by the dilution of an indicator
    • Sep.
    • J. L. Stephenson, "Theory of the measurement of blood flow by the dilution of an indicator," Bull. Math. Biophys., vol.10, no.3, pp. 117-121, Sep. 1948.
    • (1948) Bull. Math. Biophys. , vol.10 , Issue.3 , pp. 117-121
    • Stephenson, J.L.1
  • 18
    • 0343696136 scopus 로고
    • Mathematical considerations of indicator dilution techniques
    • Feb.
    • C. W. Sheppard, "Mathematical considerations of indicator dilution techniques," Minn. Med., vol.37, no.2, pp. 93-104, Feb. 1954.
    • (1954) Minn. Med. , vol.37 , Issue.2 , pp. 93-104
    • Sheppard, C.W.1
  • 19
    • 77049181625 scopus 로고
    • On the theory of indicator-dilution method for measurement of blood flow and volume
    • Jun.
    • P. Meier and K. L. Zierler, "On the theory of indicator-dilution method for measurement of blood flow and volume," J. Appl. Physiol., vol.6, no.12, pp. 731-744, Jun. 1954.
    • (1954) J. Appl. Physiol. , vol.6 , Issue.12 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 20
    • 0002586831 scopus 로고
    • Estimations of cardiac output and central blood volume by dye dilution
    • P. Dow, "Estimations of cardiac output and central blood volume by dye dilution," Physiol. Rev., vol.36, no.1, pp. 77-102, 1956.
    • (1956) Physiol. Rev. , vol.36 , Issue.1 , pp. 77-102
    • Dow, P.1
  • 22
    • 0000606319 scopus 로고
    • Theoretical basis of indicator-dilution methods for measuring flow and volume
    • Mar.
    • K. L. Zierler, "Theoretical basis of indicator-dilution methods for measuring flow and volume," Circ. Res., vol.10, pp. 393-407, Mar. 1962.
    • (1962) Circ. Res. , vol.10 , pp. 393-407
    • Zierler, K.L.1
  • 23
    • 0027770955 scopus 로고
    • Myocardial regional blood flow: Quantitative measurement by computer analysis of contrast enhanced echocardiographic images
    • V. Mor-Avi, D. David, S. Akselrod, Y. Bitton, and I. Choshniak, "Myocardial regional blood flow: Quantitative measurement by computer analysis of contrast enhanced echocardiographic images," Ultrasound Med. Biol., vol.19, no.8, pp. 619-633, 1993.
    • (1993) Ultrasound Med. Biol. , vol.19 , Issue.8 , pp. 619-633
    • Mor-Avi, V.1    David, D.2    Akselrod, S.3    Bitton, Y.4    Choshniak, I.5
  • 24
    • 70449262022 scopus 로고
    • The determination of cardiac output by the dilution method without arterial sampling: II Validation of precordial recording
    • Dec.
    • W. H. Pritchard, W. J. MacIntyre, and T. W. Moir, "The determination of cardiac output by the dilution method without arterial sampling: II Validation of precordial recording," Circulation, vol.18, no.6, pp. 1147-1154, Dec. 1958.
    • (1958) Circulation , vol.18 , Issue.6 , pp. 1147-1154
    • Pritchard, W.H.1    MacIntyre, W.J.2    Moir, T.W.3
  • 25
    • 0031404162 scopus 로고    scopus 로고
    • Modeling tracer kinetics in dynamic Gd-DTPA MR imaging
    • Jan.-Feb.
    • P. S. Tofts, "Modeling tracer kinetics in dynamic Gd-DTPA MR imaging," J. Magn. Reson. Imag., vol.7, no.1, pp. 91-101, Jan.-Feb., 1997.
    • (1997) J. Magn. Reson. Imag. , vol.7 , Issue.1 , pp. 91-101
    • Tofts, P.S.1
  • 26
    • 0025980839 scopus 로고
    • Colour perfusion imaging: A new application of computed tomography
    • Mar.
    • K. A. Miles, M. Hayball, and A. K. Dixon, "Colour perfusion imaging: A new application of computed tomography," Lancet, vol.337, pp. 643-645, Mar. 1991.
    • (1991) Lancet , vol.337 , pp. 643-645
    • Miles, K.A.1    Hayball, M.2    Dixon, A.K.3
  • 27
    • 0033978497 scopus 로고    scopus 로고
    • Are microbubbles free flowing tracers through the myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging
    • Jan.
    • K. Tiemann, T. Schlosser, C. Pohl, D. Bimmel, G. Wietasch, A. Hoeft, J. Likungu, C. Vahlhaus, S. Kuntz, N. C. Nanda, H. Becher, and B. Luderitz, "Are microbubbles free flowing tracers through the myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging," Echocardiography, vol.17, no.1, pp. 17-27, Jan. 2000.
    • (2000) Echocardiography , vol.17 , Issue.1 , pp. 17-27
    • Tiemann, K.1    Schlosser, T.2    Pohl, C.3    Bimmel, D.4    Wietasch, G.5    Hoeft, A.6    Likungu, J.7    Vahlhaus, C.8    Kuntz, S.9    Nanda, N.C.10    Becher, H.11    Luderitz, B.12
  • 28
    • 0038782124 scopus 로고    scopus 로고
    • Echoscintigraphy: A new imaging modality for the reduction of color blooming and acoustic shadowing in contrast sonography
    • Jul.
    • T. Schlosser, C. Pohl, S. Kuntz-Hehner, H. Omran, H. Becher, and K. Tiemann, "Echoscintigraphy: A new imaging modality for the reduction of color blooming and acoustic shadowing in contrast sonography," Ultrasound Med. Biol., vol.29, no.7, pp. 985-991, Jul. 2003.
    • (2003) Ultrasound Med. Biol. , vol.29 , Issue.7 , pp. 985-991
    • Schlosser, T.1    Pohl, C.2    Kuntz-Hehner, S.3    Omran, H.4    Becher, H.5    Tiemann, K.6
  • 29
    • 74849138633 scopus 로고    scopus 로고
    • Investigation of the relationship of non-linear backscattered ultrasound intensity with microbubble concentration at low MI
    • Feb.
    • M. Lampaskis and M. A. Averkiou, "Investigation of the relationship of non-linear backscattered ultrasound intensity with microbubble concentration at low MI," Ultrasound Med. Biol., vol.36, no.2, pp. 306-312, Feb. 2010.
    • (2010) Ultrasound Med. Biol. , vol.36 , Issue.2 , pp. 306-312
    • Lampaskis, M.1    Averkiou, M.A.2
  • 30
    • 40349113040 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced ultrasonography (DCE-US) with quantification of tumor perfusion: A new diagnostic tool to evaluate the early effects of antiangiogenic treatment
    • Dec.
    • N. Lassau, L. Chami, B. Benatsou, P. Peronneau, and A. Roche, "Dynamic contrast-enhanced ultrasonography (DCE-US) with quantification of tumor perfusion: A new diagnostic tool to evaluate the early effects of antiangiogenic treatment," Eur. Radiol., vol.17, suppl. 6, pp. F89-F98, Dec. 2007.
    • (2007) Eur. Radiol. , vol.17 , Issue.SUPPL. 6
    • Lassau, N.1    Chami, L.2    Benatsou, B.3    Peronneau, P.4    Roche, A.5
  • 31
    • 25444488044 scopus 로고    scopus 로고
    • A posteriori respiratory gating in contrast ultrasound for assessment of hepatic perfusion
    • Jun.
    • G. Renault, F. Tranquart, V. Perlbarg, A. Bleuzen, A. Herment, and F. Frouin, "A posteriori respiratory gating in contrast ultrasound for assessment of hepatic perfusion," Phys. Med. Biol., vol.50, pp. 4465-4480, Jun. 2005.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 4465-4480
    • Renault, G.1    Tranquart, F.2    Perlbarg, V.3    Bleuzen, A.4    Herment, A.5    Frouin, F.6
  • 32
    • 52649112757 scopus 로고    scopus 로고
    • Hepatic perfusion imaging using factor analysis of contrast enhanced ultrasound
    • Oct.
    • G. J. Lueck, T. K. Kim, P. N. Burns, and A. L. Martel, "Hepatic perfusion imaging using factor analysis of contrast enhanced ultrasound," IEEE Trans. Med. Imaging, vol.27, no.10, pp. 1449-1457, Oct. 2008.
    • (2008) IEEE Trans. Med. Imaging , vol.27 , Issue.10 , pp. 1449-1457
    • Lueck, G.J.1    Kim, T.K.2    Burns, P.N.3    Martel, A.L.4
  • 33
    • 0037851014 scopus 로고    scopus 로고
    • Videodensitometric methods for cardiac output measurements
    • Jan.
    • M. Mischi, T. Kalker, and E. Korsten, "Videodensitometric methods for cardiac output measurements," EURASIP J. Appl. Signal Process., vol.5, pp. 479-489, Jan. 2003.
    • (2003) EURASIP J. Appl. Signal Process. , vol.5 , pp. 479-489
    • Mischi, M.1    Kalker, T.2    Korsten, E.3
  • 35
    • 41049116728 scopus 로고    scopus 로고
    • On the physical and stochastic representation of an indicator dilution curve as a gamma variate
    • M. Mischi, J. A. der Boer, and H. H. M. Korsten, "On the physical and stochastic representation of an indicator dilution curve as a gamma variate," Physiol. Meas., vol.29, no.3, pp. 281-294, 2008.
    • (2008) Physiol. Meas. , vol.29 , Issue.3 , pp. 281-294
    • Mischi, M.1    Der Boer, J.A.2    Korsten, H.H.M.3
  • 36
    • 0037028596 scopus 로고    scopus 로고
    • Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent
    • Feb.
    • N. G. Fisher, J. P. Christiansen, H. Leong-Poi, A. R. Jayaweera, J. R. Lindner, and S. Kaul, "Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent," J. Am. Coll. Radiol., vol.39, no.3, pp. 530-537, Feb. 2002.
    • (2002) J. Am. Coll. Radiol. , vol.39 , Issue.3 , pp. 530-537
    • Fisher, N.G.1    Christiansen, J.P.2    Leong-Poi, H.3    Jayaweera, A.R.4    Lindner, J.R.5    Kaul, S.6
  • 37
    • 23644458777 scopus 로고    scopus 로고
    • Semiquantitative analysis of ultrasonic cerebral perfusion imaging
    • DOI 10.1016/j.ultrasmedbio.2005.01.001, PII S0301562905000037
    • C. Krogias, T. Postert, S. Meves, W. Wilkening, H. Przuntek, and J. Eyding, "Semiquantitative analysis of ultrasonic cerebral perfusion imaging," Ultrasound Med. Biol., vol.31, no.8, pp. 1007-1012, Aug. 2005. (Pubitemid 41115841)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.8 , pp. 1007-1012
    • Krogias, C.1    Postert, T.2    Meves, S.3    Wilkening, W.4    Przuntek, H.5    Eyding, J.6
  • 38
    • 13644270562 scopus 로고    scopus 로고
    • Modeling ultrasound contrast measurement of blood flow and perfusion in biological tissue
    • Feb.
    • J. M. Thijssen and C. L. de Korte, "Modeling ultrasound contrast measurement of blood flow and perfusion in biological tissue," Ultrasound Med. Biol., vol.31, no.2, pp. 279-285, Feb. 2005.
    • (2005) Ultrasound Med. Biol. , vol.31 , Issue.2 , pp. 279-285
    • Thijssen, J.M.1    De Korte, C.L.2
  • 39
    • 0242270558 scopus 로고    scopus 로고
    • Transfer function analysis of ultrasonic time-intensity measurements
    • Oct.
    • P.-C. Li and M.-J. Yang, "Transfer function analysis of ultrasonic time-intensity measurements," Ultrasound Med. Biol., vol.29, no.10, pp. 1493-1500, Oct. 2003.
    • (2003) Ultrasound Med. Biol. , vol.29 , Issue.10 , pp. 1493-1500
    • Li, P.-C.1    Yang, M.-J.2
  • 41
    • 33746821518 scopus 로고    scopus 로고
    • A new formalism for the quantification of tissue perfusion by the destruction- replenishment method in contrast ultrasound imaging
    • Jun.
    • M. Arditi, P. J. A. Frinking, X. Zhou, and N. G. Rognin, "A new formalism for the quantification of tissue perfusion by the destruction- replenishment method in contrast ultrasound imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol.53, no.6, pp. 1118- 1129, Jun. 2006.
    • (2006) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.53 , Issue.6 , pp. 1118-1129
    • Arditi, M.1    Frinking, P.J.A.2    Zhou, X.3    Rognin, N.G.4
  • 42
    • 0013965085 scopus 로고
    • The logarithm in biology: I. Mechanisms generating the log-normal distribution
    • Nov.
    • A. L. Koch, "The logarithm in biology: I. Mechanisms generating the log-normal distribution," J. Theor. Biol., vol.12, no.2, pp. 276- 290, Nov. 1966.
    • (1966) J. Theor. Biol. , vol.12 , Issue.2 , pp. 276-290
    • Koch, A.L.1
  • 43
    • 0014519798 scopus 로고
    • The logarithm in biology: II. Distributions simulation the log-normal
    • May
    • A. L. Koch, "The logarithm in biology: II. Distributions simulation the log-normal," J. Theor. Biol., vol.23, no.2, pp. 251-268, May. 1969.
    • (1969) J. Theor. Biol. , vol.23 , Issue.2 , pp. 251-268
    • Koch, A.L.1
  • 44
    • 0034978467 scopus 로고    scopus 로고
    • Log-normal distributions across the sciences: Keys and clues
    • May
    • E. Limpert, W. A. Stahel, and M. Abbt, "Log-normal distributions across the sciences: Keys and clues," Bioscience, vol.51, no.5, pp. 341-352, May 2001.
    • (2001) Bioscience , vol.51 , Issue.5 , pp. 341-352
    • Limpert, E.1    Stahel, W.A.2    Abbt, M.3
  • 45
    • 0001747857 scopus 로고
    • An empirical formula for indicatordilution curves as obtained in human beings
    • Sep.
    • R. W. Stow and P. S. Hetzel, "An empirical formula for indicatordilution curves as obtained in human beings," J. Appl. Physiol., vol.7, no.2, pp. 161-167, Sep. 1954.
    • (1954) J. Appl. Physiol. , vol.7 , Issue.2 , pp. 161-167
    • Stow, R.W.1    Hetzel, P.S.2
  • 46
    • 84978567941 scopus 로고
    • The geometry of log-normal and related distributions and an application to tracer-dilution curves
    • M. E. Wise, "The geometry of log-normal and related distributions and an application to tracer-dilution curves," Stat. Neerl., vol.20, no.1, pp. 119-142, 1966.
    • (1966) Stat. Neerl. , vol.20 , Issue.1 , pp. 119-142
    • Wise, M.E.1
  • 47
    • 0028806018 scopus 로고
    • A new method of analyzing indicator dilution curves
    • Dec.
    • R. A. F. Linton, N. W. F. Linton, and D. M. Band, "A new method of analyzing indicator dilution curves," Cardiovasc. Res., vol.30, no.6, pp. 930-938, Dec. 1995.
    • (1995) Cardiovasc. Res. , vol.30 , Issue.6 , pp. 930-938
    • Linton, R.A.F.1    Linton, N.W.F.2    Band, D.M.3
  • 48
    • 0031033230 scopus 로고    scopus 로고
    • The shape of indicator dilution curves used for cardiac output measurement in man
    • Jan.
    • D. M. Band, R. A. F. Linton, T. K. O'Brien, M. M. Jonas, and N. W. F. Linton, "The shape of indicator dilution curves used for cardiac output measurement in man," J. Physiol., vol.498, no.1, pp. 225-229, Jan. 1997.
    • (1997) J. Physiol. , vol.498 , Issue.1 , pp. 225-229
    • Band, D.M.1    Linton, R.A.F.2    O'Brien, T.K.3    Jonas, M.M.4    Linton, N.W.F.5
  • 49
    • 0034698013 scopus 로고    scopus 로고
    • A class of flow bifurcation models with lognormal distribution and fractal dispersion
    • Jul.
    • H. Qian and J. B. Bassingthwaighte, "A class of flow bifurcation models with lognormal distribution and fractal dispersion," J. Theor. Biol., vol.205, no.2, pp. 261-268, Jul. 2000.
    • (2000) J. Theor. Biol. , vol.205 , Issue.2 , pp. 261-268
    • Qian, H.1    Bassingthwaighte, J.B.2
  • 51
    • 0014052435 scopus 로고
    • Perfect mixers in series model for fitting venoarterial indicatordilution curves
    • Feb.
    • E. J. Schlossmacher, H. Weinstein, S. Lochaya, and A. B. Shaffer, "Perfect mixers in series model for fitting venoarterial indicatordilution curves," J. Appl. Physiol., vol.22, no.2, pp. 327-332, Feb. 1967.
    • (1967) J. Appl. Physiol. , vol.22 , Issue.2 , pp. 327-332
    • Schlossmacher, E.J.1    Weinstein, H.2    Lochaya, S.3    Shaffer, A.B.4
  • 52
    • 0021034659 scopus 로고
    • The derivation of the gamma-variate relationship for tracer dilution curves
    • R. Davenport, "The derivation of the gamma-variate relationship for tracer dilution curves," J. Nucl. Med., vol.24, no.10, pp. 945-948, 1983.
    • (1983) J. Nucl. Med. , vol.24 , Issue.10 , pp. 945-948
    • Davenport, R.1
  • 53
    • 0001641623 scopus 로고
    • Indicator transit time considered as a gamma variate
    • Jun.
    • H. K. Thompson, C. F. Starmer, R. E. Whalen, and H. D. McIntosh, "Indicator transit time considered as a gamma variate," Circ. Res., vol.14, pp. 501-515, Jun. 1964.
    • (1964) Circ. Res. , vol.14 , pp. 501-515
    • Thompson, H.K.1    Starmer, C.F.2    Whalen, R.E.3    McIntosh, H.D.4
  • 54
    • 0346118792 scopus 로고    scopus 로고
    • Erroneous and inappropriate use of gamma fits to tracer-dilution curves in magnetic resonance imaging and nuclear medicine
    • Nov.
    • X. Li, J. Tian, and R. K. Millard, "Erroneous and inappropriate use of gamma fits to tracer-dilution curves in magnetic resonance imaging and nuclear medicine," Magn. Reson. Imag, vol.21, no.9, pp. 1095-1096, Nov. 2003.
    • (2003) Magn. Reson. Imag , vol.21 , Issue.9 , pp. 1095-1096
    • Li, X.1    Tian, J.2    Millard, R.K.3
  • 55
    • 33749743450 scopus 로고
    • The dye dilution method for describing the central circulation. An analysis of factors shaping the time-concentration curves
    • E. V. Newman, M. Merrell, A. Genecin, C. Monge, W. R. Milnor, and W. P. McKeever, "The dye dilution method for describing the central circulation. An analysis of factors shaping the time-concentration curves," Circulation, vol.4, no.5, pp. 735-746, 1951.
    • (1951) Circulation , vol.4 , Issue.5 , pp. 735-746
    • Newman, E.V.1    Merrell, M.2    Genecin, A.3    Monge, C.4    Milnor, W.R.5    McKeever, W.P.6
  • 56
    • 0001342827 scopus 로고
    • The random walk problem in relation to the physiology of circulatory mixing
    • Jul.-Sep.
    • C. W. Sheppard and L. J. Savage, "The random walk problem in relation to the physiology of circulatory mixing," Phys. Rev., vol.83, pp. 489-490, Jul.-Sep. 1951.
    • (1951) Phys. Rev. , vol.83 , pp. 489-490
    • Sheppard, C.W.1    Savage, L.J.2
  • 57
    • 0014747922 scopus 로고
    • The dispersion of indicator in the cardio-pulmonary system
    • Mar.
    • K. H. Norwich and S. Zerlin, "The dispersion of indicator in the cardio-pulmonary system," Bull. Math. Biophys., vol.32, no.1, pp. 25-43, Mar. 1970.
    • (1970) Bull. Math. Biophys. , vol.32 , Issue.1 , pp. 25-43
    • Norwich, K.H.1    Zerlin, S.2
  • 58
    • 0013992712 scopus 로고
    • Tracer dilution curves in cardiology and random walk and lognormal distributions
    • M. E. Wise, "Tracer dilution curves in cardiology and random walk and lognormal distributions," Acta Physiol. Pharmacol. Neerl., vol.14, no.2, pp. 175-204, 1966.
    • (1966) Acta Physiol. Pharmacol. Neerl. , vol.14 , Issue.2 , pp. 175-204
    • Wise, M.E.1
  • 59
    • 0021163861 scopus 로고
    • Physiological interpretation of the skewness of indicatordilution curves; Theoretical considerations and a practical application
    • Jul.
    • J. M. Bogaard, S. J. Smith, A. Versprille, M. E. Wise, and F. Hagemeijer, "Physiological interpretation of the skewness of indicatordilution curves; Theoretical considerations and a practical application," Basic Res. Cardiol., vol.79, no.4, pp. 479-493, Jul. 1984.
    • (1984) Basic Res. Cardiol. , vol.79 , Issue.4 , pp. 479-493
    • Bogaard, J.M.1    Smith, S.J.2    Versprille, A.3    Wise, M.E.4    Hagemeijer, F.5
  • 60
  • 61
    • 0013893605 scopus 로고
    • Applications of the lagged normal density function curve as a model for arterial dilution curves
    • J. B. Bassingthwaighte, F. H. Ackerman, and E. H. Wood, "Applications of the lagged normal density function curve as a model for arterial dilution curves," Circ. Res., vol.18, no.4, pp. 398-415, 1966.
    • (1966) Circ. Res. , vol.18 , Issue.4 , pp. 398-415
    • Bassingthwaighte, J.B.1    Ackerman, F.H.2    Wood, E.H.3
  • 62
    • 0024543909 scopus 로고
    • Digital angiographic impulse response analysis of regional myocardial perfusion: Linearity, reproducibility, accuracy, and comparison with conventional indicator dilution curve parameters in phantom and canine models
    • May
    • N. L. Eigler, J. M. Pfaff, A. Zeiher, J. S. Whiting, and J. S. Forrester, "Digital angiographic impulse response analysis of regional myocardial perfusion: Linearity, reproducibility, accuracy, and comparison with conventional indicator dilution curve parameters in phantom and canine models," Circ. Res., vol.64, no.5, pp. 853-866, May 1989.
    • (1989) Circ. Res. , vol.64 , Issue.5 , pp. 853-866
    • Eigler, N.L.1    Pfaff, J.M.2    Zeiher, A.3    Whiting, J.S.4    Forrester, J.S.5
  • 63
    • 0017187170 scopus 로고
    • The lagged normal family of probability density functions applied to indicator-dilution curves
    • Sep.
    • G. C. Davis and M. H. Kutner, "The lagged normal family of probability density functions applied to indicator-dilution curves," Biometrics, vol.32, no.3, pp. 669-675, Sep. 1976.
    • (1976) Biometrics , vol.32 , Issue.3 , pp. 669-675
    • Davis, G.C.1    Kutner, M.H.2
  • 64
    • 71849094546 scopus 로고    scopus 로고
    • Quantification of tumor microvascularity with respiratory gated contrast enhanced ultrasound for monitoring therapy
    • Jan.
    • M. Averkiou, M. Lampaskis, K. Kyriakopoulou, D. Skarlos, G. Klouvas, C. Strouthos, and E. Leen, "Quantification of tumor microvascularity with respiratory gated contrast enhanced ultrasound for monitoring therapy," Ultrasound Med. Biol., vol.36, no.1, pp. 68-77, Jan. 2010.
    • (2010) Ultrasound Med. Biol. , vol.36 , Issue.1 , pp. 68-77
    • Averkiou, M.1    Lampaskis, M.2    Kyriakopoulou, K.3    Skarlos, D.4    Klouvas, G.5    Strouthos, C.6    Leen, E.7
  • 65
    • 33646128415 scopus 로고    scopus 로고
    • Moment method for the local density random walk model interpolation of ultrasound contrast agent dilution curves
    • Brno, Czech Republic
    • M. Mischi, A. C. C. M. Kalker, and H. H. M. Korsten, "Moment method for the local density random walk model interpolation of ultrasound contrast agent dilution curves," in Proc. 17th Int. EURASIP Conf. BIOSIGNAL 2004, Brno, Czech Republic, pp. 33-35.
    • (2004) Proc. 17th Int. EURASIP Conf. BIOSIGNAL , pp. 33-35
    • Mischi, M.1    Kalker, A.C.C.M.2    Korsten, H.H.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.