메뉴 건너뛰기




Volumn 34, Issue 1, 2008, Pages 47-55

Real-Time Myocardial Contrast Echocardiography for Assessing Perfusion and Function in Healthy and Infarcted Wistar Rats

Author keywords

Experimental echocardiography; Myocardial contrast echocardiography; Myocardial infarction; Myocardial perfusion; Myocardial regional wall motion; Rats

Indexed keywords

CARDIOVASCULAR SYSTEM; ENGINEERING RESEARCH; HEALTH CARE; MEDICAL IMAGING; RATS; REAL TIME SYSTEMS;

EID: 37049024959     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2007.06.027     Document Type: Article
Times cited : (10)

References (32)
  • 1
    • 0014892550 scopus 로고
    • Effects of coronary blood flow and perfusion pressure on left ventricular contractility in dogs
    • Abel R.M., and Reis R.L. Effects of coronary blood flow and perfusion pressure on left ventricular contractility in dogs. Circ Res 27 (1970) 961-971
    • (1970) Circ Res , vol.27 , pp. 961-971
    • Abel, R.M.1    Reis, R.L.2
  • 2
    • 0026533530 scopus 로고
    • Relation of perfusion defects observed with myocardial contrast echocardiography to the severity of coronary stenosis: correlation with thallium-201 single-photon emission tomography
    • Cheirif J., Desir R.M., Bolli R., Mahamarian J.J., Zoghbi W.A., Verani M.S., and Quinones M.A. Relation of perfusion defects observed with myocardial contrast echocardiography to the severity of coronary stenosis: correlation with thallium-201 single-photon emission tomography. J Am Coll Cardiol 19 (1992) 1343-1349
    • (1992) J Am Coll Cardiol , vol.19 , pp. 1343-1349
    • Cheirif, J.1    Desir, R.M.2    Bolli, R.3    Mahamarian, J.J.4    Zoghbi, W.A.5    Verani, M.S.6    Quinones, M.A.7
  • 3
    • 33845223507 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography evolving as a clinically feasible technique for accurate, rapid, and safe assessment of myocardial perfusion: The evidence so far
    • Dijkmans P.A., Senior R., Becher H., Porter T.R., Wei K., Visser C.A., and Kamp O. Myocardial contrast echocardiography evolving as a clinically feasible technique for accurate, rapid, and safe assessment of myocardial perfusion: The evidence so far. J Am Coll Cardiol 48 (2006) 2168-2177
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2168-2177
    • Dijkmans, P.A.1    Senior, R.2    Becher, H.3    Porter, T.R.4    Wei, K.5    Visser, C.A.6    Kamp, O.7
  • 4
    • 0031023586 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: Potential application in the cardiac catheterization laboratory
    • Firschke C., Lindner J.R., Goodman N.C., Goodman N.C., Skyba D.M., Wei K., and Kaul S. Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: Potential application in the cardiac catheterization laboratory. J Am Coll Cardiol 29 (1997) 207-216
    • (1997) J Am Coll Cardiol , vol.29 , pp. 207-216
    • Firschke, C.1    Lindner, J.R.2    Goodman, N.C.3    Goodman, N.C.4    Skyba, D.M.5    Wei, K.6    Kaul, S.7
  • 5
    • 0037028596 scopus 로고    scopus 로고
    • Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent
    • Fisher N.G., Christiansen J.P., Leong-Poi H., Jayaweera A.R., Lindner J.R., and Kaul S. Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent. J Am Coll Cardiol 39 (2002) 530-537
    • (2002) J Am Coll Cardiol , vol.39 , pp. 530-537
    • Fisher, N.G.1    Christiansen, J.P.2    Leong-Poi, H.3    Jayaweera, A.R.4    Lindner, J.R.5    Kaul, S.6
  • 6
    • 0019124899 scopus 로고
    • Significance of regional wall thickening abnormalities relative to transmural myocardial perfusion in anesthetized dogs
    • Gallagher K.P., Kumada T., Koziol J.A., McKown M.D., Kemper W.S., and Ross Jr. J. Significance of regional wall thickening abnormalities relative to transmural myocardial perfusion in anesthetized dogs. Circulation 62 (1980) 1266-1274
    • (1980) Circulation , vol.62 , pp. 1266-1274
    • Gallagher, K.P.1    Kumada, T.2    Koziol, J.A.3    McKown, M.D.4    Kemper, W.S.5    Ross Jr., J.6
  • 7
    • 0025841834 scopus 로고
    • Steal-prone coronary circulation in chronically instrumented dogs: isoflurane versus adenosine
    • Hartman J.C., Kampine J.P., Schmeling W.T., and Warltier D.C. Steal-prone coronary circulation in chronically instrumented dogs: isoflurane versus adenosine. Anesthesiology 74 (1991) 744-756
    • (1991) Anesthesiology , vol.74 , pp. 744-756
    • Hartman, J.C.1    Kampine, J.P.2    Schmeling, W.T.3    Warltier, D.C.4
  • 8
    • 0021718405 scopus 로고
    • Contrast echocardiography in acute myocardial ischemia: I. In vivo determination of total left ventricular "area at risk"
    • Kaul S., Pandian N.G., Okada R.D., Rohost G.M., and Weyman A.E. Contrast echocardiography in acute myocardial ischemia: I. In vivo determination of total left ventricular "area at risk". J Am Coll Cardiol 4 (1984) 1272-1282
    • (1984) J Am Coll Cardiol , vol.4 , pp. 1272-1282
    • Kaul, S.1    Pandian, N.G.2    Okada, R.D.3    Rohost, G.M.4    Weyman, A.E.5
  • 9
    • 0024592182 scopus 로고
    • Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiography
    • Kaul S., Kelly P., Oliner J.D., Glasheen W.P., Keller M.W., and Watson D.D. Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiography. J Am Coll Cardiol 13 (1989) 468-482
    • (1989) J Am Coll Cardiol , vol.13 , pp. 468-482
    • Kaul, S.1    Kelly, P.2    Oliner, J.D.3    Glasheen, W.P.4    Keller, M.W.5    Watson, D.D.6
  • 10
    • 0030811703 scopus 로고    scopus 로고
    • Coronary and myocardial blood volumes: Non-invasive tools to assess the coronary microcirculation?
    • Kaul S., and Jayaweera A.R. Coronary and myocardial blood volumes: Non-invasive tools to assess the coronary microcirculation?. Circulation 96 (1997) 719-724
    • (1997) Circulation , vol.96 , pp. 719-724
    • Kaul, S.1    Jayaweera, A.R.2
  • 11
    • 14944367848 scopus 로고    scopus 로고
    • Cine-MRI assessment of cardiac function in mice anesthetized with ketamine/xylazine and isoflurane
    • Kober F., Iltis I., Cozzone P.J., and Bernard M. Cine-MRI assessment of cardiac function in mice anesthetized with ketamine/xylazine and isoflurane. MAGMA 17 (2004) 157-161
    • (2004) MAGMA , vol.17 , pp. 157-161
    • Kober, F.1    Iltis, I.2    Cozzone, P.J.3    Bernard, M.4
  • 13
    • 0027208291 scopus 로고
    • Long-term follow-up of global and regional left ventricular function by two-dimensional echocardiography after thrombolytic therapy in acute myocardial infarction
    • Nixdorff U., Erbel R., Pop T., Rupprecht H.J., Henrichs K.J., Morchen S., and Meyer J. Long-term follow-up of global and regional left ventricular function by two-dimensional echocardiography after thrombolytic therapy in acute myocardial infarction. Int J Cardiol 41 (1993) 31-47
    • (1993) Int J Cardiol , vol.41 , pp. 31-47
    • Nixdorff, U.1    Erbel, R.2    Pop, T.3    Rupprecht, H.J.4    Henrichs, K.J.5    Morchen, S.6    Meyer, J.7
  • 14
    • 9244249811 scopus 로고    scopus 로고
    • Quantitative assessment of infarct size in vivo by myocardial contrast echocardiography in a murine acute myocardial infarction model
    • Park S.W., Lee S.Y., Park S.J., Lee S.C., Gwon H.C., and Kim D.K. Quantitative assessment of infarct size in vivo by myocardial contrast echocardiography in a murine acute myocardial infarction model. Int J Cardiol 97 (2004) 393-398
    • (2004) Int J Cardiol , vol.97 , pp. 393-398
    • Park, S.W.1    Lee, S.Y.2    Park, S.J.3    Lee, S.C.4    Gwon, H.C.5    Kim, D.K.6
  • 15
    • 0033009439 scopus 로고    scopus 로고
    • Real-time visualization of myocardial perfusion and wall thickening in human beings with intravenous ultrasonographic contrast and accelerated intermittent harmonic imaging
    • Porter T.R., Li S., Jiang L., Grayburn P., and Deligonul U. Real-time visualization of myocardial perfusion and wall thickening in human beings with intravenous ultrasonographic contrast and accelerated intermittent harmonic imaging. J Am Soc Echocardiogr 12 (1999) 266-271
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 266-271
    • Porter, T.R.1    Li, S.2    Jiang, L.3    Grayburn, P.4    Deligonul, U.5
  • 16
    • 0035282050 scopus 로고    scopus 로고
    • Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging
    • Porter T.R., Xie F., Silver M., Kricsfeld D., and Oleary E. Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging. J Am Coll Cardiol 37 (2001) 748-753
    • (2001) J Am Coll Cardiol , vol.37 , pp. 748-753
    • Porter, T.R.1    Xie, F.2    Silver, M.3    Kricsfeld, D.4    Oleary, E.5
  • 17
    • 0017643309 scopus 로고
    • The wavefront phenomenon of ischemic cell death. 1. Myocardial infarct size vs duration of coronary occlusion in dogs
    • Reimer K.A., Lowe J.E., Rasmussen M.M., and Jennings R.B. The wavefront phenomenon of ischemic cell death. 1. Myocardial infarct size vs duration of coronary occlusion in dogs. Circulation 56 (1977) 786-794
    • (1977) Circulation , vol.56 , pp. 786-794
    • Reimer, K.A.1    Lowe, J.E.2    Rasmussen, M.M.3    Jennings, R.B.4
  • 18
    • 0037396410 scopus 로고    scopus 로고
    • Lower receiving frequencies than transmitting frequencies could yield improved results for contrast imaging: An in vivo study in closed chest canines
    • Rusk R.A., Mori Y., Li X., Mao Z., von Behren P.L., Paine D., Kenny A., and Sahn D.J. Lower receiving frequencies than transmitting frequencies could yield improved results for contrast imaging: An in vivo study in closed chest canines. Echocardiography 20 (2003) 257-264
    • (2003) Echocardiography , vol.20 , pp. 257-264
    • Rusk, R.A.1    Mori, Y.2    Li, X.3    Mao, Z.4    von Behren, P.L.5    Paine, D.6    Kenny, A.7    Sahn, D.J.8
  • 21
    • 0024723470 scopus 로고
    • Recommendations for quantification of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standarts, Subcomittee on Quantitation of Two-Dimensional Echocardiograms
    • Schiller N.B., Shah P.M., Crawford M., DeMaria A., Devereux R., Feigenbaum H., Gutgesell H., Reichek N., Sahn D., and Schnittger I. Recommendations for quantification of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standarts, Subcomittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 2 (1989) 358-367
    • (1989) J Am Soc Echocardiogr , vol.2 , pp. 358-367
    • Schiller, N.B.1    Shah, P.M.2    Crawford, M.3    DeMaria, A.4    Devereux, R.5    Feigenbaum, H.6    Gutgesell, H.7    Reichek, N.8    Sahn, D.9    Schnittger, I.10
  • 22
    • 0035282040 scopus 로고    scopus 로고
    • Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography
    • Shimoni S., Zoghbi W.A., Xie F., Kricsfeld D., Iskander S., Gobar L., Mikati I.A., Abukhalil J., Verani M.S., O'Leary E.L., and Porter T.R. Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography. J Am Coll Cardiol 37 (2001) 741-747
    • (2001) J Am Coll Cardiol , vol.37 , pp. 741-747
    • Shimoni, S.1    Zoghbi, W.A.2    Xie, F.3    Kricsfeld, D.4    Iskander, S.5    Gobar, L.6    Mikati, I.A.7    Abukhalil, J.8    Verani, M.S.9    O'Leary, E.L.10    Porter, T.R.11
  • 24
    • 0032714578 scopus 로고    scopus 로고
    • Real-time contrast echo assessment of myocardial perfusion at low emission power: First experimental and clinical results using power pulse inversion imaging
    • Tiemann K., Lohmeier S., Kuntz S., Koster J., Pohl C., Burns P.R.T., Nanda N.C., Luderitz B., and Becher H. Real-time contrast echo assessment of myocardial perfusion at low emission power: First experimental and clinical results using power pulse inversion imaging. Echocardiography 16 (1999) 799-809
    • (1999) Echocardiography , vol.16 , pp. 799-809
    • Tiemann, K.1    Lohmeier, S.2    Kuntz, S.3    Koster, J.4    Pohl, C.5    Burns, P.R.T.6    Nanda, N.C.7    Luderitz, B.8    Becher, H.9
  • 26
    • 0032127747 scopus 로고    scopus 로고
    • Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: Bolus or continuous infusion?
    • Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., and Kaul S. Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: Bolus or continuous infusion?. J Am Coll Cardiol 32 (1998) 252-260
    • (1998) J Am Coll Cardiol , vol.32 , pp. 252-260
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 27
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., and Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 97 (1998) 473-483
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 28
    • 0027412622 scopus 로고
    • Transmural redistribution of myocardial blood flow during isoflurane anesthesia and its effects on regional myocardial function in a canine model of fixed coronary stenosis
    • Wilton N.C., Knight P.R., Ullrich K., Martin B., and Gallagher K.P. Transmural redistribution of myocardial blood flow during isoflurane anesthesia and its effects on regional myocardial function in a canine model of fixed coronary stenosis. Anesthesiology 78 (1993) 510-523
    • (1993) Anesthesiology , vol.78 , pp. 510-523
    • Wilton, N.C.1    Knight, P.R.2    Ullrich, K.3    Martin, B.4    Gallagher, K.P.5
  • 29
    • 0019161307 scopus 로고
    • Cross-sectional echocardiography. III. Analysis of mathematic models for quantifying volume of symmetric and asymmetric left ventricles
    • Wyatt H.L., Meerbaum S., Heng M.K., Gueret P., and Corday E. Cross-sectional echocardiography. III. Analysis of mathematic models for quantifying volume of symmetric and asymmetric left ventricles. Am Heart J 100 (1980) 821-828
    • (1980) Am Heart J , vol.100 , pp. 821-828
    • Wyatt, H.L.1    Meerbaum, S.2    Heng, M.K.3    Gueret, P.4    Corday, E.5
  • 30
    • 0032941888 scopus 로고    scopus 로고
    • Two-dimensional echocardiography with a 15-MHz transducer is a promising alternative for in vivo measurement of left ventricular mass in mice
    • Youn H.J., Rokosh G., Lester S.J., Simpson P., Schiller N.B., and Foster E. Two-dimensional echocardiography with a 15-MHz transducer is a promising alternative for in vivo measurement of left ventricular mass in mice. J Am Soc Echocardiogr 12 (1999) 70-75
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 70-75
    • Youn, H.J.1    Rokosh, G.2    Lester, S.J.3    Simpson, P.4    Schiller, N.B.5    Foster, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.