메뉴 건너뛰기




Volumn 64, Issue 5, 2008, Pages 1302-1307

Pullout strength and load to failure properties of self-tapping cortical screws in synthetic and cadaveric environments representative of healthy and osteoporotic bone

Author keywords

Biomaterial properties; Biomechanical testing; Osteoporosis; Self tapping screws

Indexed keywords

ANALYTIC METHOD; ARTICLE; BIOMECHANICS; BONE SCREW; CADAVER; COMPARATIVE STUDY; CONTROLLED STUDY; HUMAN; HUMAN TISSUE; MATERIALS TESTING; MECHANICAL STRESS; OSTEOPOROSIS; PRIORITY JOURNAL; SELF TAPPING SCREW;

EID: 43449118717     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e318169cd71     Document Type: Article
Times cited : (43)

References (12)
  • 1
    • 33646091529 scopus 로고    scopus 로고
    • Experimental evaluation of the holding power/stiffness of the self-tapping bone screws in normal and osteoporotic bone material
    • Battula S, Schoenfeld A, Vrabec G, Njus G. Experimental evaluation of the holding power/stiffness of the self-tapping bone screws in normal and osteoporotic bone material. Clin Biomech. 2006;21:533-537.
    • (2006) Clin Biomech , vol.21 , pp. 533-537
    • Battula, S.1    Schoenfeld, A.2    Vrabec, G.3    Njus, G.4
  • 2
    • 0025086070 scopus 로고
    • The treatment of nonunions and pseudoarthroses of the humeral shaft
    • Rosen H. The treatment of nonunions and pseudoarthroses of the humeral shaft. Orthop Clin N Am. 1990;21:725-742.
    • (1990) Orthop Clin N Am , vol.21 , pp. 725-742
    • Rosen, H.1
  • 3
    • 0037822088 scopus 로고    scopus 로고
    • Internal fracture fixation in patients with osteoporosis
    • Cornell CN. Internal fracture fixation in patients with osteoporosis. J Am Acad Orthop Surg. 2003;11:109-119.
    • (2003) J Am Acad Orthop Surg , vol.11 , pp. 109-119
    • Cornell, C.N.1
  • 4
    • 6844252251 scopus 로고    scopus 로고
    • Time analysis for screw application: Traditional lag technique versus self-tapping lag technique
    • Gonzalez JV, Trout BM, Stuck RM, Vrbos LA. Time analysis for screw application: traditional lag technique versus self-tapping lag technique. J Foot Ankle Surg. 1997;36:422-424.
    • (1997) J Foot Ankle Surg , vol.36 , pp. 422-424
    • Gonzalez, J.V.1    Trout, B.M.2    Stuck, R.M.3    Vrbos, L.A.4
  • 5
    • 0035291060 scopus 로고    scopus 로고
    • Effect of cutting flute design on cortical bone screw insertion torque and pullout strength
    • Yerby S, Scott CC, Evans NJ, Messing KL, Carter DR. Effect of cutting flute design on cortical bone screw insertion torque and pullout strength. J Orthop Trauma. 2001;15:216-221.
    • (2001) J Orthop Trauma , vol.15 , pp. 216-221
    • Yerby, S.1    Scott, C.C.2    Evans, N.J.3    Messing, K.L.4    Carter, D.R.5
  • 6
    • 0035345047 scopus 로고    scopus 로고
    • Pullout properties of 3.5-mm AO/ASIF self-tapping and cortex screws in a uniform synthetic material and in canine bone
    • Murphy TP, Hill CM, Kapatkin AS, Radin A, Shofer FS, Smith GK. Pullout properties of 3.5-mm AO/ASIF self-tapping and cortex screws in a uniform synthetic material and in canine bone. Vet Surg. 2001;30:253-260.
    • (2001) Vet Surg , vol.30 , pp. 253-260
    • Murphy, T.P.1    Hill, C.M.2    Kapatkin, A.S.3    Radin, A.4    Shofer, F.S.5    Smith, G.K.6
  • 7
    • 24644487721 scopus 로고    scopus 로고
    • Pullout strength of self-tapping screws inserted to different depths
    • Berkowitz R, Njus G, Vrabec G. Pullout strength of self-tapping screws inserted to different depths. J Orthop Trauma. 2005; 19:462-465.
    • (2005) J Orthop Trauma , vol.19 , pp. 462-465
    • Berkowitz, R.1    Njus, G.2    Vrabec, G.3
  • 8
    • 84996652546 scopus 로고    scopus 로고
    • Standard test method for determining axial pullout strength of medical bone screws
    • ASTM Designation: F1691-96, Philadelphia, PA: American Society for Testing and Materials;
    • ASTM Designation: F1691-96. Standard test method for determining axial pullout strength of medical bone screws. Book of ASTM Standards. Philadelphia, PA: American Society for Testing and Materials; 1996;1-2.
    • (1996) Book of ASTM Standards , pp. 1-2
  • 9
    • 33846235129 scopus 로고    scopus 로고
    • Osteoporotic fragility fractures
    • Browner B, Jupiter J, Levine A, Trafton eds, 3rd ed. Philadelphia, PA: WB Saunders Company;
    • Lane J, Cornell C, Lobo M, Kwon D. Osteoporotic fragility fractures. In: Browner B, Jupiter J, Levine A, Trafton PG, eds. Skeletal Trauma. 3rd ed. Philadelphia, PA: WB Saunders Company; 2003:287-348.
    • (2003) Skeletal Trauma , pp. 287-348
    • Lane, J.1    Cornell, C.2    Lobo, M.3    Kwon, D.4
  • 10
    • 26044463553 scopus 로고    scopus 로고
    • Principles of internal fixation
    • Browner B, Jupiter J, Levine A, Trafton eds, 3rd ed. Philadelphia, PA: WB Saunders Company;
    • Mazzocca AD, Caputo AE, Browner BD, Mast JW, Mendes MW. Principles of internal fixation. In: Browner B, Jupiter J, Levine A, Trafton PG, eds. Skeletal Trauma. 3rd ed. Philadelphia, PA: WB Saunders Company; 2003:195-249.
    • (2003) Skeletal Trauma , pp. 195-249
    • Mazzocca, A.D.1    Caputo, A.E.2    Browner, B.D.3    Mast, J.W.4    Mendes, M.W.5
  • 11
    • 24644492044 scopus 로고    scopus 로고
    • Principles of internal fixation
    • Bucholz RW, Heckman JD, eds, 5th ed. Philadelphia, PA: Lippincott, Williams and Wilkins;
    • Chandler RW. Principles of internal fixation. In: Bucholz RW, Heckman JD, eds. Rockwood and Green's Fractures in Adults. 5th ed. Philadelphia, PA: Lippincott, Williams and Wilkins; 2001:181-229.
    • (2001) Rockwood and Green's Fractures in Adults , pp. 181-229
    • Chandler, R.W.1
  • 12
    • 0028538937 scopus 로고
    • Holding power of threaded external fixation pins in the near and far cortices of cadaveric canine tibiae
    • McDonald DE, Palmer RH, Hulse DA. Holding power of threaded external fixation pins in the near and far cortices of cadaveric canine tibiae. Vet Surg. 1994;23:488-493.
    • (1994) Vet Surg , vol.23 , pp. 488-493
    • McDonald, D.E.1    Palmer, R.H.2    Hulse, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.