1
-
-
0026033659
-
Three Cancellous Bone Screws Versus a Screw-Angle Plate in the Treatment of Garden I and II Fractures of the Femoral neck
-
Kuokkanen, H., Korkala, O., Antti-Poika, I., Tolonen, J., Lehtimaki, M. Y., and Silvennoinen, T., 1991, "Three Cancellous Bone Screws Versus a Screw-Angle Plate in the Treatment of Garden I And II Fractures of the Femoral neck," Acta Orthop. Belg., 57(1), pp. 53-57.
-
(1991)
Acta Orthop. Belg.
, vol.57
, Issue.1
, pp. 53-57
-
-
Kuokkanen, H.1
Korkala, O.2
Antti-Poika, I.3
Tolonen, J.4
Lehtimaki, M.Y.5
Silvennoinen, T.6
-
2
-
-
0028265771
-
Implant/bone constructs in femoral neck osteotomy. An autopsy study
-
Benterud, J. G., Alho, A., and Hoiseth, A., 1994, "Implant/Bone Constructs in Femoral Neck Osteotomy. An Autopsy Study," Arch. Orthop. Trauma Surg., 113(2), pp. 97-100. (Pubitemid 24094204)
-
(1994)
Archives of Orthopaedic and Trauma Surgery
, vol.113
, Issue.2
, pp. 97-100
-
-
Benterud, J.G.1
Alho, A.2
Hoiseth, A.3
-
3
-
-
1542284810
-
Lower Extremity Fixation
-
JB Lippincott, Philadelphia, PA
-
Tencer, A. F., and Johnson, K. D., 1994, "Lower Extremity Fixation," Biomechanics in Orthopedic Trauma, JB Lippincott, Philadelphia, PA, pp. 249-274.
-
(1994)
Biomechanics in Orthopedic Trauma
, pp. 249-274
-
-
Tencer, A.F.1
Johnson, K.D.2
-
4
-
-
0003581752
-
-
5th ed., Lippincott, Williams, and Wilkins, Philadelphia, PA
-
R. W. Bucholz and J. D. Heckman, eds., 2001, Rockwood and Green's Fractures in Adults, 5th ed., Lippincott, Williams, and Wilkins, Philadelphia, PA.
-
(2001)
Rockwood and Green's Fractures in Adults
-
-
Bucholz, R.W.1
Heckman, J.D.2
-
5
-
-
0036142618
-
Quality of life related to fracture displacement among elderly patients with femoral neck fractures treated with internal fixation
-
DOI 10.1097/00005131-200201000-00008
-
Tidermark, J., Zethraeus, N., Svensson, O., Tornkvist, H., and Ponzer, S., 2002, "Quality of Life Related to Fracture Displacement Among Elderly Patients With Femoral Neck Fractures Treated With Internal Fixation," J. Orthop. Trauma, 16(1), pp. 34-38. (Pubitemid 34055938)
-
(2002)
Journal of Orthopaedic Trauma
, vol.16
, Issue.1
, pp. 34-38
-
-
Tidermark, J.1
Zethraeus, N.2
Svensson, O.3
Tornkvist, H.4
Ponzer, S.5
-
6
-
-
2542501410
-
Cancellous Screw Fixation for Femoral Neck Fractures: One Hundred and Sixteen Patients
-
Lee, K. B., Howe, T. S., and Chang, H. C., 2004, "Cancellous Screw Fixation for Femoral Neck Fractures: One Hundred and Sixteen Patients," Ann. Acad. Med. Singapore, 33(2), pp. 248-251.
-
(2004)
Ann. Acad. Med. Singapore
, vol.33
, Issue.2
, pp. 248-251
-
-
Lee, K.B.1
Howe, T.S.2
Chang, H.C.3
-
7
-
-
20144378786
-
Treatment of Undisplaced Femoral Neck Fractures in the Elderly
-
Chen, W. C., Yu, S. W., Tseng, I. C., Su, J. Y., Tu, Y. K., and Chen, W. J., 2005, "Treatment of Undisplaced Femoral Neck Fractures in the Elderly," J. Trauma: Inj., Infect., Crit. Care, 58(5), pp. 1035-1039.
-
(2005)
J. Trauma: Inj., Infect., Crit. Care
, vol.58
, Issue.5
, pp. 1035-1039
-
-
Chen, W.C.1
Yu, S.W.2
Tseng, I.C.3
Su, J.Y.4
Tu, Y.K.5
Chen, W.J.6
-
8
-
-
33748154056
-
A Mechanical Evaluation of Two Fixation Methods Using Cancellous Screws for Coronal Fractures of the Lateral Condyle of the Distal Femur (OTA Type 33B)
-
Jarit, G. J., Kummer, F. J., Gibber, M. J., and Egol, K. A., 2006, "A Mechanical Evaluation of Two Fixation Methods Using Cancellous Screws for Coronal Fractures of the Lateral Condyle of the Distal Femur (OTA Type 33B)," J. Orthop. Trauma, 20(4), pp. 273-276.
-
(2006)
J. Orthop. Trauma
, vol.20
, Issue.4
, pp. 273-276
-
-
Jarit, G.J.1
Kummer, F.J.2
Gibber, M.J.3
Egol, K.A.4
-
9
-
-
33745375022
-
Two Cannulated Hip Screws for Femoral Neck Fractures: Treatment of Choice or Asking for Trouble?
-
Krastman, P., van den Bent, R. P., Krijnen, P., and Schipper, I. B., 2006, "Two Cannulated Hip Screws for Femoral Neck Fractures: Treatment of Choice Or Asking for Trouble?," Arch. Orthop. Trauma Surg., 126(5), pp. 297-303.
-
(2006)
Arch. Orthop. Trauma Surg.
, vol.126
, Issue.5
, pp. 297-303
-
-
Krastman, P.1
Van Den Bent, R.P.2
Krijnen, P.3
Schipper, I.B.4
-
10
-
-
0026863992
-
Role of Loads and Prosthesis Material Properties on the Mechanics of the Proximal Femur after Total Hip Arthroplasty
-
Cheal, E. J., Spector, M., and Hayes, W. C., 1992, "Role of Loads and Prosthesis Material Properties on the Mechanics of the Proximal Femur After Total Hip Arthroplasty," J. Orthop. Res., 10, pp. 405-422.
-
(1992)
J. Orthop. Res.
, vol.10
, pp. 405-422
-
-
Cheal, E.J.1
Spector, M.2
Hayes, W.C.3
-
11
-
-
0034277593
-
Construct Stiffness of Different Fixation Methods for Supracondylar Femoral Fractures above Total Knee Prostheses
-
Cusick, R. P., Lucas, G. L., McQueen, D. A., and Graber, C. D., 2000, "Construct Stiffness of Different Fixation Methods for Supracondylar Femoral Fractures Above Total Knee Prostheses," Am. J. Orthop., 29(9), pp. 695-699.
-
(2000)
Am. J. Orthop.
, vol.29
, Issue.9
, pp. 695-699
-
-
Cusick, R.P.1
Lucas, G.L.2
McQueen, D.A.3
Graber, C.D.4
-
12
-
-
0034922981
-
Structural Properties of a New Design of Composite Replicate Femurs and Tibias
-
Heiner, A. D., and Brown, T. D., 2001, "Structural Properties of a New Design of Composite Replicate Femurs and Tibias," J. Biomech., 34, pp. 773-781.
-
(2001)
J. Biomech.
, vol.34
, pp. 773-781
-
-
Heiner, A.D.1
Brown, T.D.2
-
13
-
-
34248195124
-
Structural Properties of an Improved Redesign of Composite Replicate Femurs and Tibias
-
Reno, NV, Apr. 30-May 3
-
Heiner, A. D., and Brown, T. D., 2003, "Structural Properties of an Improved Redesign of Composite Replicate Femurs and Tibias," Trans 29th Society for Biomaterials, Reno, NV, Apr. 30-May 3, Vol. 26, p. 702.
-
(2003)
Trans 29th Society for Biomaterials
, vol.26
, pp. 702
-
-
Heiner, A.D.1
Brown, T.D.2
-
14
-
-
4644278172
-
Unstable Proximal Extraarticular Tibia Fractures:, A. Biomechanical Evaluation of Four Methods of Fixation
-
Peindl, R. D., Zura, R. D., Vincent, A., Coley, E. R., Bosse, M. J., and Sims, S. H., 2004, "Unstable Proximal Extraarticular Tibia Fractures:, A. Biomechanical Evaluation of Four Methods of Fixation," J. Orthop. Trauma, 18(8), pp. 540-545.
-
(2004)
J. Orthop. Trauma
, vol.18
, Issue.8
, pp. 540-545
-
-
Peindl, R.D.1
Zura, R.D.2
Vincent, A.3
Coley, E.R.4
Bosse, M.J.5
Sims, S.H.6
-
15
-
-
43049099294
-
Biomechanical Evaluation of Periprosthetic Femoral Fracture Fixation
-
Zdero, R., Walker, R., Waddell, J. P., and Schemitsch, E. H., 2008, "Biomechanical Evaluation of Periprosthetic Femoral Fracture Fixation," J. Bone Jt. Surg., Am. Vol., Vol. 90(5), pp. 1068-1077.
-
(2008)
J. Bone Jt. Surg., Am.
, vol.90
, Issue.5
, pp. 1068-1077
-
-
Zdero, R.1
Walker, R.2
Waddell, J.P.3
Schemitsch, E.H.4
-
18
-
-
0014853889
-
Holding Power of Orthopaedic Screws in Bone
-
Koranyi, E., Bowman, C. E., Knecht, C. D., and Janssen, M., 1970, "Holding Power of Orthopaedic Screws in Bone," Clin. Orthop. Relat. Res., 72, pp. 283-286.
-
(1970)
Clin. Orthop. Relat. Res.
, vol.72
, pp. 283-286
-
-
Koranyi, E.1
Bowman, C.E.2
Knecht, C.D.3
Janssen, M.4
-
19
-
-
0021125646
-
Holding Power of Different Screws in the Femoral Head. A Study in Human Cadaver Hips
-
Frandsen, P. A., Christoffersen, H., and Madsen, T., 1984, "Holding Power of Different Screws in the Femoral Head. A Study in Human Cadaver Hips," Acta Orthop. Scand., 55(3), pp. 349-351.
-
(1984)
Acta Orthop. Scand.
, vol.55
, Issue.3
, pp. 349-351
-
-
Frandsen, P.A.1
Christoffersen, H.2
Madsen, T.3
-
20
-
-
84995132390
-
Holding Power of Orthopedic Screws in Equine Third Metacarpal and Metatarsal Bones; Part 2. Adult Horse Bone
-
Yovich, J. V., Turner, A. S., and Smith, F. W., 1985, "Holding Power of Orthopedic Screws in Equine Third Metacarpal and Metatarsal Bones; Part 2. Adult Horse Bone," Vet. Surg., 14, pp. 230-234.
-
(1985)
Vet. Surg.
, vol.14
, pp. 230-234
-
-
Yovich, J.V.1
Turner, A.S.2
Smith, F.W.3
-
21
-
-
0022628372
-
A Biomechanical Study of Intrapeduncular Screw Fixation in the Lumbosacral Spine
-
Zindrick, M. R., Wiltse, L. L., Widell, E. H., Thomas, J. C., Holland, R., Field, B. T., and Spencer, C. W., 1986, "A Biomechanical Study of Intrapeduncular Screw Fixation in the Lumbosacral Spine," Clin. Orthop. Relat. Res., 203, pp. 99-112.
-
(1986)
Clin. Orthop. Relat. Res.
, vol.203
, pp. 99-112
-
-
Zindrick, M.R.1
Wiltse, L.L.2
Widell, E.H.3
Thomas, J.C.4
Holland, R.5
Field, B.T.6
Spencer, C.W.7
-
22
-
-
0026440671
-
Holding Power and Reinforcement of Cancellous Screws in Human Bone
-
Kleeman, B. C., Toshitsugu, T., Gerhart, T. N., and Hayes, W. C., 1992, "Holding Power and Reinforcement of Cancellous Screws in Human Bone," Clin. Orthop. Relat. Res., 284, pp. 260-266.
-
(1992)
Clin. Orthop. Relat. Res.
, vol.284
, pp. 260-266
-
-
Kleeman, B.C.1
Toshitsugu, T.2
Gerhart, T.N.3
Hayes, W.C.4
-
23
-
-
0028284544
-
Effect of Cyclic Loading on the Holding Power of Surgical Screws
-
Firoozbakhsh, K. K., DeCoster, T. A., and Moneim, M. S., 1994, "Effect of Cyclic Loading on the Holding Power of Surgical Screws," Orthopedics, 17(7), pp. 607-611.
-
(1994)
Orthopedics
, vol.17
, Issue.7
, pp. 607-611
-
-
Firoozbakhsh, K.K.1
DeCoster, T.A.2
Moneim, M.S.3
-
24
-
-
0030221045
-
Factors Affecting the Pullout Strength of Cancellous Bone Screws
-
Chapman, J. R., Harrington, R. M., Lee, K. M., Anderson, P. A., Tencer, A. F., and Kowalski, D., 1996, "Factors Affecting the Pullout Strength of Cancellous Bone Screws," ASME J. Biomech. Eng., 118, pp. 391-398.
-
(1996)
ASME J. Biomech. Eng.
, vol.118
, pp. 391-398
-
-
Chapman, J.R.1
Harrington, R.M.2
Lee, K.M.3
Anderson, P.A.4
Tencer, A.F.5
Kowalski, D.6
-
25
-
-
0011458922
-
Mechanical Properties and Testing Methods of Bone
-
Y. H. An and R. J. Friedman, eds., CRC, Boca Raton, FL
-
An, Y. H., and Draughn, R. A., 1999, "Mechanical Properties and Testing Methods of Bone," Animal Models in Orthopaedic Research, Y. H. An and R. J. Friedman, eds., CRC, Boca Raton, FL, pp. 139-163.
-
(1999)
Animal Models in Orthopaedic Research
, pp. 139-163
-
-
An, Y.H.1
Draughn, R.A.2
-
26
-
-
0032911349
-
Determination of the Role of the Cancellous Bone in Generation of Screw Holding Power at Metaphysis
-
Bristol, Avon
-
Harnroongroj, T., and Techataweewan, A., 1999, "Determination of the Role of the Cancellous Bone in Generation of Screw Holding Power at Metaphysis," Clin. Biomech. (Bristol, Avon), 14(5), pp. 364-366.
-
(1999)
Clin. Biomech.
, vol.14
, Issue.5
, pp. 364-366
-
-
Harnroongroj, T.1
Techataweewan, A.2
-
27
-
-
0033031128
-
Impaction bone-grafting increases the holding power of cancellous screws in the femoral head. A pull-out study in human cadaver hips
-
Lenzner, A., Kaur, I., Haviko, T., Sogel, V., Gapejeva, J., Ereline, J., and Paasuke, M., 1999, "Impaction Bone-Grafting Increases the Holding Power of Cancellous Screws in the Femoral Head: A Pull-Out Study in Human Cadaver Hips," Acta Orthop. Scand., 70(1), pp. 25-28. (Pubitemid 29119115)
-
(1999)
Acta Orthopaedica Scandinavica
, vol.70
, Issue.1
, pp. 25-28
-
-
Lenzner, A.1
Kaur, I.2
Haviko, T.3
Sogel, V.4
Gapejeva, J.5
Ereline, J.6
Paasuke, M.7
-
28
-
-
0035345047
-
Pullout properties of 3.5-mm AO/ASIF self-tapping and cortex screws in a uniform synthetic material and in canine bone
-
DOI 10.1053/jvet.2001.23344
-
Murphy, T. P., Hill, C. M., Kapatkin, A. S., Radin, A., Shofer, F. S., and Smith, G. K., 2001, "Pullout Properties of 3.5-mm AO/ASIF Self-Tapping and Cortex Screws in a Uniform Synthetic Material and in Canine Bone," Vet. Surg., 30, pp. 253-260. (Pubitemid 33601816)
-
(2001)
Veterinary Surgery
, vol.30
, Issue.3
, pp. 253-260
-
-
Murphy, T.P.1
Hill, C.M.2
Kapatkin, A.S.3
Radin, A.4
Shofer, F.S.5
Smith, G.K.6
-
29
-
-
0036196593
-
Screw Pullout Strength: A Biomechanical Comparison of Large-Fragment and Small-Fragment Fixation in the Tibial Plateau
-
Westmoreland, G. L., McLaurin, T. M., and Hutton, W. C., 2002, "Screw Pullout Strength: A Biomechanical Comparison of Large-Fragment and Small-Fragment Fixation in the Tibial Plateau," J. Orthop. Trauma, 16(3), pp. 178-181.
-
(2002)
J. Orthop. Trauma
, vol.16
, Issue.3
, pp. 178-181
-
-
Westmoreland, G.L.1
McLaurin, T.M.2
Hutton, W.C.3
-
30
-
-
4844227313
-
Stress relaxation of bone significantly affects the pull-out behavior of pedicle screws
-
DOI 10.1016/j.orthres.2004.03.007, PII S0736026604000671
-
Inceoglu, S., McLain, R. F., Cayli, S., Kilincer, C., and Ferrara, L., 2004, "Stress Relaxation of Bone Significantly Affects the Pull-Out Behavior of Pedicle Screws," J. Orthop. Res., 22, pp. 1243-1247. (Pubitemid 39317914)
-
(2004)
Journal of Orthopaedic Research
, vol.22
, Issue.6
, pp. 1243-1247
-
-
Inceoglu, S.1
McLain, R.F.2
Cayli, S.3
Kilincer, C.4
Ferrara, L.5
-
31
-
-
13744264019
-
An in Vitro Biomechanical Comparison of the Insertion Variables and Pullout Mechanical Properties of AO 6.5-mm Standard Cancellous and 7.3-mm Self-Tapping, Cannulated Bone Screws in Foal Femoral Bone
-
Johnson, N. L., Galuppo, L. D., Stover, S. M., and Taylor, K. T., 2004, "An in Vitro Biomechanical Comparison of the Insertion Variables and Pullout Mechanical Properties of AO 6.5-mm Standard Cancellous and 7.3-mm Self-Tapping, Cannulated Bone Screws in Foal Femoral Bone," Vet. Surg., 33(6), pp. 681-690.
-
(2004)
Vet. Surg.
, vol.33
, Issue.6
, pp. 681-690
-
-
Johnson, N.L.1
Galuppo, L.D.2
Stover, S.M.3
Taylor, K.T.4
-
32
-
-
21344445289
-
How pilot-hole size affects bone-screw pullout strength in human cadaveric cancellous bone
-
Steeves, M., Stone, C., Mogaard, J., and Byrne, S., 2005, "How Pilot-Hole Size Affects Bone-Screw Pullout Strength in Human Cadaveric Cancellous Bone," Can. J. Surg., 48(3), pp. 207-212. (Pubitemid 40910647)
-
(2005)
Canadian Journal of Surgery
, vol.48
, Issue.3
, pp. 207-212
-
-
Steeves, M.1
Stone, C.2
Mogaard, J.3
Byrne, S.4
-
33
-
-
33646091529
-
Experimental Evaluation of the Holding Power/Stiffness of the Self-Tapping Bone Screws in Normal and Osteoporotic Bone Material
-
Bristol, Avon
-
Battula, S., Schoenfeld, A., Vrabec, G., and Njus, G. O., 2006, "Experimental Evaluation of the Holding Power/Stiffness of the Self-Tapping Bone Screws in Normal and Osteoporotic Bone Material," Clin. Biomech. (Bristol, Avon), 21, pp. 533-537.
-
(2006)
Clin. Biomech.
, vol.21
, pp. 533-537
-
-
Battula, S.1
Schoenfeld, A.2
Vrabec, G.3
Njus, G.O.4
-
34
-
-
0028163734
-
Fixation Pull-Out Response Measurement of Bone Screws and Porous-Surfaced Posts
-
Shirazi-Adl, A., Dammak, M., and Zukor, D. J., 1994, "Fixation Pull-Out Response Measurement of Bone Screws and Porous-Surfaced Posts," J. Biomech., 27(10), pp. 1249-1258.
-
(1994)
J. Biomech.
, vol.27
, Issue.10
, pp. 1249-1258
-
-
Shirazi-Adl, A.1
Dammak, M.2
Zukor, D.J.3
-
35
-
-
33748034045
-
Axial Cyclic Behavior of the Bone-Screw Interface
-
Inceoglu, S., Ehlert, M., Akbay, A., and McLain, R. F., 2006, "Axial Cyclic Behavior of the Bone-Screw Interface," Med. Eng. Phys., 28, pp. 888-893.
-
(2006)
Med. Eng. Phys.
, vol.28
, pp. 888-893
-
-
Inceoglu, S.1
Ehlert, M.2
Akbay, A.3
McLain, R.F.4
-
36
-
-
60549092945
-
Cancellous Bone Screw Purchase: A Comparison of Synthetic Femurs, Human Femurs, and Finite Element Analysis
-
in press
-
Zdero, R., Olsen, M., Bougherara, H., and Schemitsch, E., 2008, "Cancellous Bone Screw Purchase: A Comparison of Synthetic Femurs, Human Femurs, and Finite Element Analysis," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 222, in press.
-
(2008)
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
, vol.222
-
-
Zdero, R.1
Olsen, M.2
Bougherara, H.3
Schemitsch, E.4
-
37
-
-
0030131155
-
Mechanical validation of whole bone composite femur models
-
DOI 10.1016/0021-9290(95)00084-4
-
Cristofolini, L., Viceconti, M., Cappello, A., and Toni, A., 1996, "Mechanical Validation of Whole Bone Composite Femur Models," J. Biomech., 29(4), pp. 525-535. (Pubitemid 26065734)
-
(1996)
Journal of Biomechanics
, vol.29
, Issue.4
, pp. 525-535
-
-
Cristofolini, L.1
Viceconti, M.2
Cappello, A.3
Toni, A.4
-
38
-
-
0033622796
-
Mechanical Validation of Whole Bone Composite Tibia Models
-
Cristofolini, L., and Viceconti, M., 2000, "Mechanical Validation of Whole Bone Composite Tibia Models," J. Biomech., 33(3), pp. 279-288.
-
(2000)
J. Biomech.
, vol.33
, Issue.3
, pp. 279-288
-
-
Cristofolini, L.1
Viceconti, M.2
-
39
-
-
34248189246
-
The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic Femurs
-
Papini, M., Zdero, R., Schemitsch, E. H., and Zalzal, P., 2007, "The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic Femurs," ASME J. Biomech. Eng., 129(1), pp. 12-19.
-
(2007)
ASME J. Biomech. Eng.
, vol.129
, Issue.1
, pp. 12-19
-
-
Papini, M.1
Zdero, R.2
Schemitsch, E.H.3
Zalzal, P.4
-
40
-
-
0035689180
-
Fine Thread Versus Coarse Thread: A Comparison of the Maximum Holding Power
-
Gausepohl, T., Mohring, R., Pennig, D., and Koebke, J., 2001, "Fine Thread Versus Coarse Thread: A Comparison of the Maximum Holding Power," Injury, 32, pp. SD1-SD7.
-
(2001)
Injury
, vol.32
-
-
Gausepohl, T.1
Mohring, R.2
Pennig, D.3
Koebke, J.4
-
41
-
-
0030345576
-
Cancellous Bone Screw Thread Design and Holding Power
-
Asnis, S. E., Ernberg, J. J., Bostrom, M. P. G., Wright, T. M., Harrington, R. M., Tencer, A., and Peterson, M., 1996, "Cancellous Bone Screw Thread Design and Holding Power," J. Orthop. Trauma, 10(7), pp. 462-469. (Pubitemid 126432733)
-
(1996)
Journal of Orthopaedic Trauma
, vol.10
, Issue.7
, pp. 462-469
-
-
Asnis, S.E.1
Ernberg, J.J.2
Bostrom, M.P.G.3
Wright, T.M.4
Harrington, R.M.5
Tencer, A.6
Peterson, M.7
-
42
-
-
77955122538
-
Tapered Pedicle Screw Pull Out Strengths: Effect of Increasing Screw Height Outside the Pedicle
-
Goel, V., Dick, D., Rengachary, S., Garg, I., and Ebraheim, N., 2003, "Tapered Pedicle Screw Pull Out Strengths: Effect of Increasing Screw Height Outside the Pedicle," Summer Bioengineering Conference, Sonesta Beach Resort in Key Biscayne, FL, June 25-29, pp. 0117-0118.
-
(2003)
Summer Bioengineering Conference, Sonesta Beach Resort in Key Biscayne, FL, June 25-29
, pp. 117-118
-
-
Goel, V.1
Dick, D.2
Rengachary, S.3
Garg, I.4
Ebraheim, N.5
-
43
-
-
77955120135
-
Intracapsular Fractures of the Femoral Head
-
J. A. Elstrom, W. W. Virkus, and A. M. Pankovich, eds., McGraw-Hill, New York
-
Pankovich, A. M., and Elstrom, J. A., 2006, "Intracapsular Fractures of the Femoral Head," Handbook of Fractures, J. A. Elstrom, W. W. Virkus, and A. M. Pankovich, eds., McGraw-Hill, New York, pp. 264-280.
-
(2006)
Handbook of Fractures
, pp. 264-280
-
-
Pankovich, A.M.1
Elstrom, J.A.2
-
44
-
-
0020957455
-
Fatigue Failure of Cortical Bone Screws
-
Zand, M. S., Goldstein, S. A., and Matthews, L. S., 1983, "Fatigue Failure of Cortical Bone Screws," J. Biomech., 10(5), pp. 305-311.
-
(1983)
J. Biomech.
, vol.10
, Issue.5
, pp. 305-311
-
-
Zand, M.S.1
Goldstein, S.A.2
Matthews, L.S.3
-
45
-
-
0028284544
-
Effect of Cyclical Loading on the Holding Power of Surgical Screws
-
Firoozbakhsh, K. K., DeCoster, T. A., and Moneim, M. S., 1994, "Effect of Cyclical Loading on the Holding Power of Surgical Screws," Orthopedics, 17(7), pp. 607-611.
-
(1994)
Orthopedics
, vol.17
, Issue.7
, pp. 607-611
-
-
Firoozbakhsh, K.K.1
DeCoster, T.A.2
Moneim, M.S.3
-
46
-
-
24344482104
-
The Effect of End Screw Orientation on the Stability of Anterior Instrumentation in Cyclic Lateral Bending
-
Rodriguez-Olaverri, J. C., Hasharoni, A., DeWal, H., Nuzzo, R. M., Kummer, F. J., and Errico, T. J., 2005, "The Effect of End Screw Orientation on the Stability of Anterior Instrumentation in Cyclic Lateral Bending," The Spine Journal, 5, pp. 554-557.
-
(2005)
The Spine Journal
, vol.5
, pp. 554-557
-
-
Rodriguez-Olaverri, J.C.1
Hasharoni, A.2
DeWal, H.3
Nuzzo, R.M.4
Kummer, F.J.5
Errico, T.J.6
|