메뉴 건너뛰기




Volumn 20, Issue 3, 2010, Pages 725-733

Local skin and eye lens equivalent doses in interventional neuroradiology

Author keywords

Acute skin exposure; Cerebral aneurysm; Cerebral arteriovenous malformation; Eye lens dose; Interventional neuroradiology; Skin dose

Indexed keywords

ARTICLE; ARTIFICIAL EMBOLISM; BIOEQUIVALENCE; CATARACT; DIGITAL SUBTRACTION ANGIOGRAPHY; DOSIMETRY; ERYTHEMA; FLUOROSCOPY; HUMAN; HUMAN TISSUE; INTERVENTIONAL RADIOLOGY; LENS; MAJOR CLINICAL STUDY; NEURORADIOLOGY; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; SKIN; THERMOLUMINESCENCE DOSIMETER; BRAIN ANGIOGRAPHY; FUNCTIONS OF THE SKIN AND ITS APPENDAGES; PHYSIOLOGY; RADIOMETRY; RELATIVE BIOLOGIC EFFECTIVENESS;

EID: 77952310295     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-009-1598-9     Document Type: Article
Times cited : (24)

References (32)
  • 1
    • 0034436030 scopus 로고    scopus 로고
    • ICRP publication 85: Avoidance of radiation injuries from medical interventional procedures
    • ICRP
    • Valentin J, ICRP (2000) ICRP publication 85: avoidance of radiation injuries from medical interventional procedures. Ann ICRP 30(2):7-67.
    • (2000) Ann ICRP , vol.30 , Issue.2 , pp. 7-67
    • Valentin, J.1
  • 2
    • 0003736853 scopus 로고    scopus 로고
    • WHO, World Health Organization, Geneva. ISBN 13 9789241545297, ISBN 10 9241545291
    • WHO (2000) Efficacy and radiation safety in interventional radiology. World Health Organization, Geneva. ISBN 13 9789241545297, ISBN 10 9241545291.
    • (2000) Efficacy and Radiation Safety in Interventional Radiology , vol.10
  • 5
    • 33645242116 scopus 로고    scopus 로고
    • ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging
    • Vano E, Faulkner K (2006) ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging. Radiat Prot Dosim 117:13-17.
    • (2006) Radiat Prot Dosim , vol.117 , pp. 13-17
    • Vano, E.1    Faulkner, K.2
  • 7
    • 33645210606 scopus 로고    scopus 로고
    • Evaluation of methods to estimate the patient dose in interventional radiology
    • Kosunen A, Komppa T, Toivonen M (2005) Evaluation of methods to estimate the patient dose in interventional radiology. Radiat Prot Dosim 117:178-184.
    • (2005) Radiat Prot Dosim , vol.117 , pp. 178-184
    • Kosunen, A.1    Komppa, T.2    Toivonen, M.3
  • 8
    • 33645224917 scopus 로고    scopus 로고
    • Characteristics of dosimeter types for skin dose measurement in practice
    • Van Dam J, Bosmans H, Marchal G, Wambersie A (2005) Characteristics of dosimeter types for skin dose measurement in practice. Radiat Prot Dosim 177:185-189.
    • (2005) Radiat Prot Dosim , vol.177 , pp. 185-189
    • Van Dam, J.1    Bosmans, H.2    Marchal, G.3    Wambersie, A.4
  • 10
    • 33645465157 scopus 로고    scopus 로고
    • Patient dosimetry for x rays used in medical imaging (report 74)
    • International Commission on Radiation Units and Measurements (ICRU), i. ISSN 1473-6691, ISBN 0199203208
    • International Commission on Radiation Units and Measurements (ICRU) (2005) Patient dosimetry for x rays used in medical imaging (report 74). J ICRU 5(2):i. ISSN 1473-6691, ISBN 0199203208.
    • (2005) J ICRU , vol.5 , Issue.2
  • 11
    • 51849086474 scopus 로고    scopus 로고
    • Dosimetry in diagnostic radiology: An international code of practice
    • IAEA, International Atomic Energy Agency (IAEA), Vienna. ISSN 0074-1914, ISBN 92-0-115406-2
    • IAEA (2007) Dosimetry in diagnostic radiology: an international code of practice. Technical reports series No 457. International Atomic Energy Agency (IAEA), Vienna. ISSN 0074-1914, ISBN 92-0-115406-2.
    • (2007) Technical reports series No 457
  • 12
    • 33645800787 scopus 로고    scopus 로고
    • Relationship between fluoroscopy time, dose-area product, body weight and maximum skin dose in cardiac interventional procedures
    • Chida K, Saito H, Otani H, Kohzuki M, Takahashi S, Yamada S, Shirato K, Zuguchi M (2006) Relationship between fluoroscopy time, dose-area product, body weight and maximum skin dose in cardiac interventional procedures. AJR Am J Roentgenol 186:774-778.
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 774-778
    • Chida, K.1    Saito, H.2    Otani, H.3    Kohzuki, M.4    Takahashi, S.5    Yamada, S.6    Shirato, K.7    Zuguchi, M.8
  • 14
    • 77952549717 scopus 로고    scopus 로고
    • Swedish Radiation Protection Authority (SSI) (2002) The Swedish Radiation Protection Authority's regulations and general advice on diagnostic standard doses and reference levels within medical x-ray diagnostics. SSI FS 2002:2 (also published as regulation SSMFS 2008:20), Accessed 2 Mar 2009
    • Swedish Radiation Protection Authority (SSI) (2002) The Swedish Radiation Protection Authority's regulations and general advice on diagnostic standard doses and reference levels within medical x-ray diagnostics. SSI FS 2002:2 (also published as regulation SSMFS 2008:20). http://www. stralsakerhetsmyndigheten. se/In- English/Regulations/Radiationprotection/. Accessed 2 Mar 2009.
    • (2002)
  • 18
    • 33645241077 scopus 로고    scopus 로고
    • Patient dosimetry in diagnostic radiology and interventional radiology: A practical approach using trigger levels
    • Faulkner K, Ortiz-Lopes P, Vano E (2005) Patient dosimetry in diagnostic radiology and interventional radiology: a practical approach using trigger levels. Radiat Prot Dosim 117:166-168.
    • (2005) Radiat Prot Dosim , vol.117 , pp. 166-168
    • Faulkner, K.1    Ortiz-Lopes, P.2    Vano, E.3
  • 20
    • 4043103604 scopus 로고    scopus 로고
    • A method for real time estimation of entrance skin dose distribution in interventional neuroradiology
    • Rampada O, Rapolo R (2004) A method for real time estimation of entrance skin dose distribution in interventional neuroradiology. Med Phys 31:2356-2361.
    • (2004) Med Phys , vol.31 , pp. 2356-2361
    • Rampada, O.1    Rapolo, R.2
  • 21
    • 0942277191 scopus 로고    scopus 로고
    • Dose measurements for patients and physicians using a glass dosimeter during endovascular treatment for brain disease
    • Nishizawa K, Moritake T, Matsumaru Y, Tsuboi K, Iwai K (2003) Dose measurements for patients and physicians using a glass dosimeter during endovascular treatment for brain disease. Rad Prot Dosim 107:247-252.
    • (2003) Rad Prot Dosim , vol.107 , pp. 247-252
    • Nishizawa, K.1    Moritake, T.2    Matsumaru, Y.3    Tsuboi, K.4    Iwai, K.5
  • 22
    • 33645222049 scopus 로고    scopus 로고
    • Patientdosimetry approaches in interventional cardiology and literature dose data review
    • Padovani R, Quai E (2005) Patientdosimetry approaches in interventional cardiology and literature dose data review. Radiat Prot Dosim 117:217-221.
    • (2005) Radiat Prot Dosim , vol.117 , pp. 217-221
    • Padovani, R.1    Quai, E.2
  • 23
    • 0042433485 scopus 로고    scopus 로고
    • A study on radiation doses and irradiated areas in cerebral embolisation
    • Theodorakou C, Horrocks JA (2003) A study on radiation doses and irradiated areas in cerebral embolisation. Br J Radiol 76:546-552.
    • (2003) Br J Radiol , vol.76 , pp. 546-552
    • Theodorakou, C.1    Horrocks, J.A.2
  • 25
    • 0033853364 scopus 로고    scopus 로고
    • Absorbed doses and deterministic effects to patients from interventional neuroradiology
    • Mooney RB, McKinstry CS, Kamel HA (2000) Absorbed doses and deterministic effects to patients from interventional neuroradiology. Br J Radiol 73(871):745-751.
    • (2000) Br J Radiol , vol.73 , Issue.871 , pp. 745-751
    • Mooney, R.B.1    McKinstry, C.S.2    Kamel, H.A.3
  • 27
    • 0035999401 scopus 로고    scopus 로고
    • Adult patient doses in interventional neuroradiology
    • Gkanatsios NA, Huda W, Peters KR (2002) Adult patient doses in interventional neuroradiology. Med Phys 29:717-723.
    • (2002) Med Phys , vol.29 , pp. 717-723
    • Gkanatsios, N.A.1    Huda, W.2    Peters, K.R.3
  • 28
    • 0010740173 scopus 로고
    • International standardization of reference radiations and calibration procedures for radiation protection instruments
    • Kölzer W, Maushart R (eds), Verlag TüV Rheinland
    • Alberts WG, Böhm J, Kramer HM, Iles WJ, Schwartz RB, Thompson IMG (1994) International standardization of reference radiations and calibration procedures for radiation protection instruments. In: Kölzer W, Maushart R (eds) Strahlenschutz: Physik und Meßtechnik, vol 1. Verlag TüV Rheinland, pp 181-188.
    • (1994) Strahlenschutz: Physik und Meßtechnik , vol.1 , pp. 181-188
    • Alberts, W.G.1    Böhm, J.2    Kramer, H.M.3    Iles, W.J.4    Schwartz, R.B.5    Thompson, I.M.G.6
  • 29
    • 42649140767 scopus 로고    scopus 로고
    • ICRP publication 103: Recommendations of the IRCP
    • ICRP
    • ICRP (2007) ICRP publication 103: recommendations of the IRCP. Ann ICRP 37:2-4.
    • (2007) Ann ICRP , vol.37 , pp. 2-4
  • 30
    • 77952544239 scopus 로고    scopus 로고
    • Computerized Imaging Reference Systems (CIRS), Accessed 2 Mar 2009
    • Computerized Imaging Reference Systems (CIRS) (2002) ATOM: adult female phantom handling instructions. http://www.cirsinc.com,admin@ cirsinc.com. Accessed 2 Mar 2009.
    • (2002) ATOM: Adult Female Phantom Handling Instructions
  • 31
    • 56849124126 scopus 로고    scopus 로고
    • Dose measurements on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters
    • Moritake T, Matsumau Y, Takigawa T, Nishizawa K, Matsumura A, Tsuboi K (2008) Dose measurements on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters. AJNR Am J Neuroradiol 29:1910-1917.
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1910-1917
    • Moritake, T.1    Matsumau, Y.2    Takigawa, T.3    Nishizawa, K.4    Matsumura, A.5    Tsuboi, K.6
  • 32
    • 21244493648 scopus 로고    scopus 로고
    • Patient and staff doses in interventional x-ray procedures in Sweden
    • Persliden (2005) Patient and staff doses in interventional x-ray procedures in Sweden. Radiat Prot Dosim 114:150-157.
    • (2005) Radiat Prot Dosim , vol.114 , pp. 150-157
    • Persliden1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.