-
1
-
-
0034989324
-
Skin injuries from fluoroscopically guided procedures: Part 1: Characteristics of radiation injury
-
Koenig, T. R., Wolff, D., Mettler, F. A. and Wagner, L. K. Skin injuries frCm fluoroscopically guided procedures: Part 1: characteristics of radiation injury. Am. J. Roentgenol. 177, 3-11 (2001).
-
(2001)
Am. J. Roentgenol.
, vol.177
, pp. 3-11
-
-
Koenig, T.R.1
Wolff, D.2
Mettler, F.A.3
Wagner, L.K.4
-
2
-
-
0034979308
-
Skin injuries from fluoroscopically guided procedures: Part 2: Review of 73 cases and recommendations for minimising dose delivered to patient
-
Koenig, T. R., Mettler, F. A. and Wagner, L. K. Skin injuries from flRoroscopically guided procedures: Part 2: review of 73 cases and recommendations for minimising dose delivered to patient. Am. J. Roentgenol. 177, 13-20 (2001).
-
(2001)
Am. J. Roentgenol.
, vol.177
, pp. 13-20
-
-
Koenig, T.R.1
Mettler, F.A.2
Wagner, L.K.3
-
3
-
-
0035834027
-
Real-time quantification and display of skin radiation during coronary angiography and intervention
-
den Boer, A., de Feijter, P. J., Serruys, P. W. and Roelandt, J. R. T. C. Real-time quantification and display of skin radiation during coronary angiography and intervention. Circulation 104, 1779-1784 (2001).
-
(2001)
Circulation
, vol.104
, pp. 1779-1784
-
-
den Boer, A.1
de Feijter, P.J.2
Serruys, P.W.3
Roelandt, J.R.T.C.4
-
4
-
-
0031976931
-
Real-time measurement of skin radiation during cardiac catheterisation
-
Hwang, E., Gaxiola, E., Vlietstra, R. E., Brenner, A., Ebersole, D. and Browne, K. Real-time measurement of skin radiation during cardiac catheterisation. Cathet. Cardiovasc. Diagn. 43, 367-370 (1998).
-
(1998)
Cathet. Cardiovasc. Diagn.
, vol.43
, pp. 367-370
-
-
Hwang, E.1
Gaxiola, E.2
Vlietstra, R.E.3
Brenner, A.4
Ebersole, D.5
Browne, K.6
-
5
-
-
0031040161
-
Patient dosemetry in interventional radiology using slow films
-
Vano, E., Guibelalde, E., Fernandez, J. M., Gonzalez, L. and Ten, J. I. Patient dosemetry in interventional radiology using slow films. Br. J. Radiol. 70, 195-200 (1997).
-
(1997)
Br. J. Radiol.
, vol.70
, pp. 195-200
-
-
Vano, E.1
Guibelalde, E.2
Fernandez, J.M.3
Gonzalez, L.4
Ten, J.I.5
-
6
-
-
85008998546
-
Avoidance of Radiation Injuries from Medical Interventional Procedures
-
International Commission on Radiological Protection. ICRP Publication 85. (Oxford: Pergamon Press)
-
International Commission on Radiological Protection. ICRP Publication 85. Avoidance of Radiation Injuries from Medical Interventional Procedures. Ann. ICRP 30(2) (Oxford: Pergamon Press) (2000).
-
(2000)
Ann. ICRP
, vol.30
, Issue.2
-
-
-
7
-
-
33645222219
-
Maximum skin dose assessment in interventional cardiology: Results in three different European hospitals
-
Vienna
-
Quai, E., Padovani, R., Peterzol, A., Vano, E., Guibelalde, E. and Toivonen, M. Maximum skin dose assessment in interventional cardiology: Results in three different European hospitals. In: Proceedings of European Congress of Radiology, Vienna (2003).
-
(2003)
Proceedings of European Congress of Radiology
-
-
Quai, E.1
Padovani, R.2
Peterzol, A.3
Vano, E.4
Guibelalde, E.5
Toivonen, M.6
-
8
-
-
33645235061
-
Maximum Skin Dose Assessment in Interventional Cardiology: Large Area Detectors and Calculation Methods
-
Florence, 542
-
Quai, E., Padovani, R., Peterzol, A., Vano, E., Guibelalde, E. and Toivonen, M. Maximum Skin Dose Assessment in Interventional Cardiology: Large Area Detectors and Calculation Methods. In: Proceedings of IRPA Congress, Florence, 542 (2002).
-
(2002)
Proceedings of IRPA Congress
-
-
Quai, E.1
Padovani, R.2
Peterzol, A.3
Vano, E.4
Guibelalde, E.5
Toivonen, M.6
-
9
-
-
0035194818
-
Skin radiation injuries in patients following repeated coronary angioplasty procedures
-
Vano, E., Goicolea, J., Galvan, C., Gonzales, L., Meiggs, L., Ten, J. and Macaya, C. Skin radiation injuries in patients following repeated coronary angioplasty procedures. Br. J. Radiol. 74, 1023-1031 (2001).
-
(2001)
Br. J. Radiol.
, vol.74
, pp. 1023-1031
-
-
Vano, E.1
Goicolea, J.2
Galvan, C.3
Gonzales, L.4
Meiggs, L.5
Ten, J.6
Macaya, C.7
-
10
-
-
0029654393
-
Scales for all anatomic sites
-
LENT-SOMA
-
LENT-SOMA. Scales for all anatomic sites. Int. J. Radiat. Oncol. Biol. Phys. 31, 1049-1091 (1995).
-
(1995)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.31
, pp. 1049-1091
-
-
|