-
1
-
-
21244494043
-
Implementation of DRLs in the UK
-
0144-8420
-
B. F. Wall, " Implementation of DRLs in the UK., " Radiat. Prot. Dosim. 114, 183-187 (2005). 0144-8420
-
(2005)
Radiat. Prot. Dosim.
, vol.114
, pp. 183-187
-
-
Wall, B.F.1
-
2
-
-
21244473082
-
Unsolved or unsolvable problems with diagnostic reference levels
-
0144-8420
-
W. Leitz and A. Almen, " Unsolved or unsolvable problems with diagnostic reference levels., " Radiat. Prot. Dosim. 114, 180-182 (2005). 0144-8420
-
(2005)
Radiat. Prot. Dosim.
, vol.114
, pp. 180-182
-
-
Leitz, W.1
Almen, A.2
-
3
-
-
20244379100
-
Reference values for diagnostic radiology: Application and impact
-
0033-8419 10.1148/radiol.2352020016
-
J. E. Gray, B. R. Archer, P. F. Butler, B. B. Hobbs, F. A. Mettler, Jr., R. J. Pizzutiello, Jr., B. A. Schueler, K. J. Strauss, O. H. Suleiman, and M. J. Yaffe, " Reference values for diagnostic radiology: Application and impact., " Radiology 0033-8419 10.1148/radiol.2352020016 235, 354-358 (2005).
-
(2005)
Radiology
, vol.235
, pp. 354-358
-
-
Gray, J.E.1
Archer, B.R.2
Butler, P.F.3
Hobbs, B.B.4
Mettler Jr., F.A.5
Pizzutiello Jr., R.J.6
Schueler, B.A.7
Strauss, K.J.8
Suleiman, O.H.9
Yaffe, M.J.10
-
4
-
-
0038727162
-
Diagnostic reference levels in medical imaging: Review and additional advice
-
ICRP, " 0146-6453
-
ICRP, " Diagnostic reference levels in medical imaging: Review and additional advice., " Ann. ICRP 31, 33-52 (2001). 0146-6453
-
(2001)
Ann. ICRP
, vol.31
, pp. 33-52
-
-
-
5
-
-
0033008561
-
Patient doses from barium meal and barium enema examinations and potential for reduction through proper set-up of equipment
-
0007-1285
-
E. Yakoumakis, I. A. Tsalafoutas, P. Sandilos, H. Koulentianos, A. Kasfiki, L. Vlahos, and C. Proukakis, " Patient doses from barium meal and barium enema examinations and potential for reduction through proper set-up of equipment., " Br. J. Radiol. 72, 173-178 (1999). 0007-1285
-
(1999)
Br. J. Radiol.
, vol.72
, pp. 173-178
-
-
Yakoumakis, E.1
Tsalafoutas, I.A.2
Sandilos, P.3
Koulentianos, H.4
Kasfiki, A.5
Vlahos, L.6
Proukakis, C.7
-
6
-
-
0038142392
-
Radiation doses for barium enema and barium meal examinations in Ireland: Potential diagnostic reference levels
-
0007-1285
-
E. M. Carroll and P. C. Brennan, " Radiation doses for barium enema and barium meal examinations in Ireland: Potential diagnostic reference levels., " Br. J. Radiol. 76, 393-397 (2003). 0007-1285
-
(2003)
Br. J. Radiol.
, vol.76
, pp. 393-397
-
-
Carroll, E.M.1
Brennan, P.C.2
-
7
-
-
7744232592
-
A review of factors affecting patient doses for barium enemas and meals
-
0007-1285
-
C. J. Martin, " A review of factors affecting patient doses for barium enemas and meals., " Br. J. Radiol. 77, 864-868 (2004). 0007-1285
-
(2004)
Br. J. Radiol.
, vol.77
, pp. 864-868
-
-
Martin, C.J.1
-
8
-
-
0035025542
-
Approaches to establishing reference levels in interventional radiology
-
0144-8420
-
E. Vano and L. Gonzalez, " Approaches to establishing reference levels in interventional radiology., " Radiat. Prot. Dosim. 94, 109-112 (2001). 0144-8420
-
(2001)
Radiat. Prot. Dosim.
, vol.94
, pp. 109-112
-
-
Vano, E.1
Gonzalez, L.2
-
9
-
-
1942455802
-
Radiation exposure to patients undergoing percutaneous coronary interventions: Are current reference values too high?
-
0340-9937
-
E. Kuon, K. Empen, D. Rohde, and J. B. Dahm, " Radiation exposure to patients undergoing percutaneous coronary interventions: Are current reference values too high?, " Herz 29, 208-217 (2004). 0340-9937
-
(2004)
Herz
, vol.29
, pp. 208-217
-
-
Kuon, E.1
Empen, K.2
Rohde, D.3
Dahm, J.B.4
-
10
-
-
2442436781
-
Patient radiation doses and references levels in interventional radiology
-
0033-8362
-
M. Brambilla, G. Marano, M. Dominietto, A. R. Cotroneo, and A. Carriero, " Patient radiation doses and references levels in interventional radiology., " Radiol. Med. (Torino) 107, 408-418 (2004). 0033-8362
-
(2004)
Radiol. Med. (Torino)
, vol.107
, pp. 408-418
-
-
Brambilla, M.1
Marano, G.2
Dominietto, M.3
Cotroneo, A.R.4
Carriero, A.5
-
11
-
-
10744232211
-
Preliminary reference levels in interventional cardiology
-
0938-7994
-
V. Neofotistou, E. Vano, R. Padovani, J. Kotre, A. Dowling, M. Toivonen, S. Kottou, V. Tsapaki, S. Willis, G. Bernardi, and K. Faulkner, " Preliminary reference levels in interventional cardiology., " Eur. Radiol. 13, 2259-2263 (2003). 0938-7994
-
(2003)
Eur. Radiol.
, vol.13
, pp. 2259-2263
-
-
Neofotistou, V.1
Vano, E.2
Padovani, R.3
Kotre, J.4
Dowling, A.5
Toivonen, M.6
Kottou, S.7
Tsapaki, V.8
Willis, S.9
Bernardi, G.10
Faulkner, K.11
-
12
-
-
85027231712
-
-
ICRU, Report No. 74, Patient dosimetry for x rays used in medical imaging
-
ICRU, Report No. 74, Patient dosimetry for x rays used in medical imaging, 2005.
-
(2005)
-
-
-
13
-
-
85027237618
-
-
IEC, IEC Report No. 60601, Medical electrical equipment-Part 2-43: Particular requirements for the safety of x-ray equipment for interventional procedures, Geneva
-
IEC, IEC Report No. 60601, Medical electrical equipment-Part 2-43: Particular requirements for the safety of x-ray equipment for interventional procedures, Geneva, 2000.
-
(2000)
-
-
-
14
-
-
0036106457
-
Measuring skin dose with radiochromic dosimetry film in the cardiac catheterization laboratory
-
0017-9078 10.1097/00004032-200206000-00017
-
E. R. Giles and P. H. Murphy, " Measuring skin dose with radiochromic dosimetry film in the cardiac catheterization laboratory., " Health Phys. 0017-9078 10.1097/00004032-200206000-00017 82, 875-880 (2002).
-
(2002)
Health Phys.
, vol.82
, pp. 875-880
-
-
Giles, E.R.1
Murphy, P.H.2
-
15
-
-
33645220192
-
Reference levels in PTCA as a function of procedure complexity
-
0144-8420
-
A. Peterzol, E. Quai, R. Padovani, G. Bernardi, C. J. Kotre, and A. Dowling, " Reference levels in PTCA as a function of procedure complexity., " Radiat. Prot. Dosim. 117, 54-58 (2005). 0144-8420
-
(2005)
Radiat. Prot. Dosim.
, vol.117
, pp. 54-58
-
-
Peterzol, A.1
Quai, E.2
Padovani, R.3
Bernardi, G.4
Kotre, C.J.5
Dowling, A.6
-
16
-
-
0035025826
-
Patient dose related to the complexity of interventional cardiology procedures
-
0144-8420
-
R. Padovani, G. Bernardi, M. R. Malisan, E. Vano, G. Morocutti, and P. M. Fioretti, " Patient dose related to the complexity of interventional cardiology procedures., " Radiat. Prot. Dosim. 94, 189-192 (2001). 0144-8420
-
(2001)
Radiat. Prot. Dosim.
, vol.94
, pp. 189-192
-
-
Padovani, R.1
Bernardi, G.2
Malisan, M.R.3
Vano, E.4
Morocutti, G.5
Fioretti, P.M.6
-
17
-
-
0033858253
-
Clinical and technical determinants of the complexity of percutaneous transluminal coronary angioplasty procedures: Analysis in relation to radiation exposure parameters
-
1522-1946
-
G. Bernardi, R. Padovani, G. Morocutti, E. Vano, M. R. Malisan, M. Rinuncini, L. Spedicato, and P. M. Fioretti, " Clinical and technical determinants of the complexity of percutaneous transluminal coronary angioplasty procedures: Analysis in relation to radiation exposure parameters., " Catheter. Cardiovasc. Interv. 51, 1-9 (discussion 10) (2000). 1522-1946
-
(2000)
Catheter. Cardiovasc. Interv.
, vol.51
, pp. 1-9
-
-
Bernardi, G.1
Padovani, R.2
Morocutti, G.3
Vano, E.4
Malisan, M.R.5
Rinuncini, M.6
Spedicato, L.7
Fioretti, P.M.8
-
18
-
-
85027217023
-
-
IAEA, A Pilot Study Exploring the Possibility of Establishing Guidance Levels in X-Ray Directed Interventional Procedures: Report of a Coordinated Research Programme (in press).
-
IAEA, A Pilot Study Exploring the Possibility of Establishing Guidance Levels in X-Ray Directed Interventional Procedures: Report of a Coordinated Research Programme (in press).
-
-
-
-
19
-
-
0023740319
-
Guidelines for percutaneous transluminal coronary angioplasty. a report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty)
-
0009-7322
-
T. J. Ryan, " Guidelines for percutaneous transluminal coronary angioplasty. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty)., " Circulation 78, 486-502 (1988). 0009-7322
-
(1988)
Circulation
, vol.78
, pp. 486-502
-
-
Ryan, T.J.1
-
20
-
-
33846562368
-
Federal regulations (effective June 2006) require dose monitors on all new fluoroscopes: How will this help clinicians keep track of patient dose?
-
1546-1440
-
S. Balter, N. A. Detorie, and M. Mahesh, " Federal regulations (effective June 2006) require dose monitors on all new fluoroscopes: How will this help clinicians keep track of patient dose?, " J. Am. Coll. Radiol. 4, 130-132 (2007). 1546-1440
-
(2007)
J. Am. Coll. Radiol.
, vol.4
, pp. 130-132
-
-
Balter, S.1
Detorie, N.A.2
Mahesh, M.3
-
21
-
-
85027218941
-
-
IEC, PAS 61910-1, Radiation Dose Documentation Part 1: Equipment for radiography and radioscopy, Geneva
-
IEC, PAS 61910-1, Radiation Dose Documentation Part 1: Equipment for radiography and radioscopy, Geneva, 2007.
-
(2007)
-
-
-
22
-
-
85027238055
-
Capturing patient doses from fluoroscopically based diagnostic and interventional systems
-
0017-9078
-
S. Balter, " Capturing patient doses from fluoroscopically based diagnostic and interventional systems., " Health Phys. (in press). 0017-9078
-
Health Phys.
-
-
Balter, S.1
-
23
-
-
85027221744
-
-
http://www.leedstestobjects.com/.
-
-
-
|