메뉴 건너뛰기




Volumn 34, Issue 5, 2010, Pages 393-401

Optimizing the response from a passively controlled biventricular assist device

Author keywords

Biventricular support; Mechanical damping; Passive control; Physiological control; Rotary pump

Indexed keywords

BLOOD PRESSURE; CONTROLLERS; DAMPING; FIBER OPTIC SENSORS; LEFT VENTRICULAR ASSIST DEVICES; PHYSIOLOGICAL MODELS;

EID: 77952203037     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00870.x     Document Type: Article
Times cited : (7)

References (22)
  • 1
    • 33646242043 scopus 로고    scopus 로고
    • Progress of rotary blood pumps
    • Takatani S. Progress of rotary blood pumps. Artif Organs 2006 30 : 317 321.
    • (2006) Artif Organs , vol.30 , pp. 317-321
    • Takatani, S.1
  • 3
    • 0035158794 scopus 로고    scopus 로고
    • The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function
    • Endo G, Araki K, Kojima K, Nakamura K, Matsuzaki Y, Onitsuka T. The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function. Artif Organs 2001 25 : 697 702.
    • (2001) Artif Organs , vol.25 , pp. 697-702
    • Endo, G.1    Araki, K.2    Kojima, K.3    Nakamura, K.4    Matsuzaki, Y.5    Onitsuka, T.6
  • 4
    • 0033848032 scopus 로고    scopus 로고
    • Control strategy for biventricular assistance with mixed-flow pumps
    • Endo G, Araki K, Oshikawa M, et al. Control strategy for biventricular assistance with mixed-flow pumps. Artif Organs 2000 24 : 594 599.
    • (2000) Artif Organs , vol.24 , pp. 594-599
    • Endo, G.1    Araki, K.2    Oshikawa, M.3
  • 5
    • 0034823945 scopus 로고    scopus 로고
    • Control strategy for rotary blood pumps
    • Ohuchi K, Kikugawa D, Takahashi K, et al. Control strategy for rotary blood pumps. Artif Organs 2001 25 : 366 370.
    • (2001) Artif Organs , vol.25 , pp. 366-370
    • Ohuchi, K.1    Kikugawa, D.2    Takahashi, K.3
  • 6
    • 0033839985 scopus 로고    scopus 로고
    • Sensorless controlling method for a continuous flow left ventricular assist device
    • Oshikawa M, Araki K, Endo G, Anai H, Sato M. Sensorless controlling method for a continuous flow left ventricular assist device. Artif Organs 2000 24 : 600 605.
    • (2000) Artif Organs , vol.24 , pp. 600-605
    • Oshikawa, M.1    Araki, K.2    Endo, G.3    Anai, H.4    Sato, M.5
  • 8
    • 0001249135 scopus 로고
    • The regulation of the energy output of the heart
    • Starling EH, Visscher MB. The regulation of the energy output of the heart. J Physiol 1926 62 : 243 261.
    • (1926) J Physiol , vol.62 , pp. 243-261
    • Starling, E.H.1    Visscher, M.B.2
  • 9
    • 0036430262 scopus 로고    scopus 로고
    • Assessing the calf pulmonary function during a long-term biventricular assist device study with a centrifugal blood pump
    • Nonaka K, Linneweber J, Ichikawa S, et al. Assessing the calf pulmonary function during a long-term biventricular assist device study with a centrifugal blood pump. Artif Organs 2002 26 : 924 926.
    • (2002) Artif Organs , vol.26 , pp. 924-926
    • Nonaka, K.1    Linneweber, J.2    Ichikawa, S.3
  • 11
    • 38349148970 scopus 로고    scopus 로고
    • Acute in vivo evaluation of an implantable continuous flow biventricular assist system
    • Saeed D, Ootaki Y, Ootaki C, et al. Acute in vivo evaluation of an implantable continuous flow biventricular assist system. ASAIO J 2008 54 : 20 4.
    • (2008) ASAIO J , vol.54 , pp. 20-24
    • Saeed, D.1    Ootaki, Y.2    Ootaki, C.3
  • 12
    • 0035169631 scopus 로고    scopus 로고
    • Development of the Baylor Gyro permanently implantable centrifugal blood pump as a biventricular assist device
    • Nonaka K, Linneweber J, Ichikawa S, et al. Development of the Baylor Gyro permanently implantable centrifugal blood pump as a biventricular assist device. Artif Organs 2001 25 : 675 682.
    • (2001) Artif Organs , vol.25 , pp. 675-682
    • Nonaka, K.1    Linneweber, J.2    Ichikawa, S.3
  • 13
    • 10044219918 scopus 로고    scopus 로고
    • Current status of the Gyro centrifugal blood pump-development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project)
    • Nosé Y, Furukawa K. Current status of the Gyro centrifugal blood pump-development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project). Artif Organs 2004 28 : 953 958.
    • (2004) Artif Organs , vol.28 , pp. 953-958
    • Nosé, Y.1    Furukawa, K.2
  • 14
    • 33645474358 scopus 로고    scopus 로고
    • Physiological control of blood pumps using intrinsic pump parameters: A computer simulation study
    • Giridharan GA, Skliar M. Physiological control of blood pumps using intrinsic pump parameters: a computer simulation study. Artif Organs 2006 30 : 301 307.
    • (2006) Artif Organs , vol.30 , pp. 301-307
    • Giridharan, G.A.1    Skliar, M.2
  • 15
    • 77952124383 scopus 로고    scopus 로고
    • A passively controlled biventricular support device
    • in press).
    • Gaddum N, Timms D, Pearcy M. A passively controlled biventricular support device. Artif Organs 2010 (in press).
    • (2010) Artif Organs
    • Gaddum, N.1    Timms, D.2    Pearcy, M.3
  • 16
    • 54849415697 scopus 로고    scopus 로고
    • The BiVACOR rotary biventricular assist device: Concept and in vitro investigation
    • Timms D, Fraser J, Hayne M, Dunning J, McNeil K, Pearcy M. The BiVACOR rotary biventricular assist device: concept and in vitro investigation. Artif Organs 2008 32 : 816 819.
    • (2008) Artif Organs , vol.32 , pp. 816-819
    • Timms, D.1    Fraser, J.2    Hayne, M.3    Dunning, J.4    McNeil, K.5    Pearcy, M.6
  • 17
    • 27744465023 scopus 로고    scopus 로고
    • A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices
    • DOI 10.1111/j.1525-1594.2005.29094.x
    • Timms D, Hayne M, McNeil K, Galbraith A. A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices. Artif Organs 2005 29 : 564 572. (Pubitemid 41602856)
    • (2005) Artificial Organs , vol.29 , Issue.7 , pp. 564-572
    • Timms, D.1    Hayne, M.2    McNeil, K.3    Galbraith, A.4
  • 18
    • 27744452104 scopus 로고    scopus 로고
    • Computational fluid dynamics of gap flow in a biocentrifugal blood pump
    • Chua LP, Song G, Yu SC, Lim TM. Computational fluid dynamics of gap flow in a biocentrifugal blood pump. Artif Organs 2005 29 : 620 628.
    • (2005) Artif Organs , vol.29 , pp. 620-628
    • Chua, L.P.1    Song, G.2    Yu, S.C.3    Lim, T.M.4
  • 19
    • 0032874351 scopus 로고    scopus 로고
    • Computational fluid dynamics analysis to establish the design process of a centrifugal blood pump: Second report
    • Miyazoe Y, Sawairi T, Ito K, et al. Computational fluid dynamics analysis to establish the design process of a centrifugal blood pump: second report. Artif Organs 1999 23 : 762 768.
    • (1999) Artif Organs , vol.23 , pp. 762-768
    • Miyazoe, Y.1    Sawairi, T.2    Ito, K.3
  • 20
    • 0034838318 scopus 로고    scopus 로고
    • Computational fluid dynamics as a development tool for rotary blood pumps
    • Burgreen GW, Antaki JF, Wu ZJ, Holmes AJ. Computational fluid dynamics as a development tool for rotary blood pumps. Artif Organs 2001 25 : 336 340.
    • (2001) Artif Organs , vol.25 , pp. 336-340
    • Burgreen, G.W.1    Antaki, J.F.2    Wu, Z.J.3    Holmes, A.J.4
  • 21
    • 33644993283 scopus 로고    scopus 로고
    • Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump
    • Zhang J, Gellman B, Koert A, et al. Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump. Artif Organs 2006 30 : 168 177.
    • (2006) Artif Organs , vol.30 , pp. 168-177
    • Zhang, J.1    Gellman, B.2    Koert, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.