메뉴 건너뛰기




Volumn 34, Issue 6, 2010, Pages 473-480

A passively controlled biventricular support device

Author keywords

Baroreceptor response; Biventricular support; Mock circulation; Passive control; Rotary pump

Indexed keywords

SENSORY FEEDBACK;

EID: 77952124383     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00897.x     Document Type: Article
Times cited : (10)

References (14)
  • 1
    • 33646242043 scopus 로고    scopus 로고
    • Progress of rotary blood pumps
    • Takatani S. Progress of rotary blood pumps. Artif Organs 2006 30 : 317 321.
    • (2006) Artif Organs , vol.30 , pp. 317-321
    • Takatani, S.1
  • 2
    • 1542511338 scopus 로고    scopus 로고
    • Rotary blood pumps for cardiac assistance: A "must"?
    • Mesana TG. Rotary blood pumps for cardiac assistance: a "must"? Artif Organs 2004 28 : 218 225.
    • (2004) Artif Organs , vol.28 , pp. 218-225
    • Mesana, T.G.1
  • 3
    • 33646243597 scopus 로고    scopus 로고
    • Third-generation blood pumps with mechanical noncontact magnetic bearings
    • Hoshi H, Shinshi T, Takatani S. Third-generation blood pumps with mechanical noncontact magnetic bearings. Artif Organs 2006 30 : 324 338.
    • (2006) Artif Organs , vol.30 , pp. 324-338
    • Hoshi, H.1    Shinshi, T.2    Takatani, S.3
  • 4
    • 0033848032 scopus 로고    scopus 로고
    • Control strategy for biventricular assistance with mixed-flow pumps
    • Endo G, Araki K, Oshikawa M, et al. Control strategy for biventricular assistance with mixed-flow pumps. Artif Organs 2000 24 : 594 599.
    • (2000) Artif Organs , vol.24 , pp. 594-599
    • Endo, G.1    Araki, K.2    Oshikawa, M.3
  • 5
    • 0036430262 scopus 로고    scopus 로고
    • Assessing the calf pulmonary function during a long-term biventricular assist device study with a centrifugal blood pump
    • Nonaka K, Linneweber J, Ichikawa S, et al. Assessing the calf pulmonary function during a long-term biventricular assist device study with a centrifugal blood pump. Artif Organs 2002 26 : 924 926.
    • (2002) Artif Organs , vol.26 , pp. 924-926
    • Nonaka, K.1    Linneweber, J.2    Ichikawa, S.3
  • 7
    • 33645474358 scopus 로고    scopus 로고
    • Physiological control of blood pumps using intrinsic pump parameters: A computer simulation study
    • Giridharan GA, Skliar M. Physiological control of blood pumps using intrinsic pump parameters: a computer simulation study. Artif Organs 2006 30 : 301 307.
    • (2006) Artif Organs , vol.30 , pp. 301-307
    • Giridharan, G.A.1    Skliar, M.2
  • 8
    • 0033014684 scopus 로고    scopus 로고
    • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow
    • DOI 10.1046/j.1525-1594.1999.06397.x
    • Yuhki A, Hatoh E, Nogawa M, Miura M, Shimazaki Y, Takatani S. Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow. Artif Organs 1999 23 : 532 537. (Pubitemid 29293464)
    • (1999) Artificial Organs , vol.23 , Issue.6 , pp. 532-537
    • Yuhki, A.1    Hatoh, E.2    Nogawa, M.3    Miura, M.4    Shimazaki, Y.5    Takatani, S.6
  • 9
    • 0035158794 scopus 로고    scopus 로고
    • The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function
    • Endo G, Araki K, Kojima K, Nakamura K, Matsuzaki Y, Onitsuka T. The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function. Artif Organs 2001 25 : 697 702.
    • (2001) Artif Organs , vol.25 , pp. 697-702
    • Endo, G.1    Araki, K.2    Kojima, K.3    Nakamura, K.4    Matsuzaki, Y.5    Onitsuka, T.6
  • 10
    • 0033839985 scopus 로고    scopus 로고
    • Sensorless controlling method for a continuous flow left ventricular assist device
    • Oshikawa M, Araki K, Endo G, Anai H, Sato M. Sensorless controlling method for a continuous flow left ventricular assist device. Artif Organs 2000 24 : 600 605.
    • (2000) Artif Organs , vol.24 , pp. 600-605
    • Oshikawa, M.1    Araki, K.2    Endo, G.3    Anai, H.4    Sato, M.5
  • 11
    • 54849415697 scopus 로고    scopus 로고
    • The BiVACOR rotary biventricular assist device: Concept and in vitro investigation
    • Timms D, Fraser J, Hayne M, Dunning J, McNeil K, Pearcy M. The BiVACOR rotary biventricular assist device: concept and in vitro investigation. Artif Organs 2008 32 : 816 819.
    • (2008) Artif Organs , vol.32 , pp. 816-819
    • Timms, D.1    Fraser, J.2    Hayne, M.3    Dunning, J.4    McNeil, K.5    Pearcy, M.6
  • 14
    • 27744465023 scopus 로고    scopus 로고
    • A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices
    • DOI 10.1111/j.1525-1594.2005.29094.x
    • Timms D, Hayne M, McNeil K, Galbraith A. A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices. Artif Organs 2005 29 : 564 572. (Pubitemid 41602856)
    • (2005) Artificial Organs , vol.29 , Issue.7 , pp. 564-572
    • Timms, D.1    Hayne, M.2    McNeil, K.3    Galbraith, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.