메뉴 건너뛰기




Volumn 32, Issue 10, 2008, Pages 816-819

The BiVACOR rotary biventricular assist device: Concept and in vitro investigation

Author keywords

Biventricular assist device; Heart failure; Rotary blood pump

Indexed keywords

FIBER OPTIC SENSORS; LEFT VENTRICULAR ASSIST DEVICES;

EID: 54849415697     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2008.00633.x     Document Type: Article
Times cited : (58)

References (11)
  • 1
    • 0032909782 scopus 로고    scopus 로고
    • The REMATCH Trial: Rationale, design and end points
    • Rose E, Moskowitz A, Packer M, et al. The REMATCH Trial: rationale, design and end points. Ann Thorac Surg 1999 67 : 723 30.
    • (1999) Ann Thorac Surg , vol.67 , pp. 723-730
    • Rose, E.1    Moskowitz, A.2    Packer, M.3
  • 2
    • 33644874425 scopus 로고    scopus 로고
    • Development of a small implantable right ventricular assist device
    • Fukamachi K, Horvath DJ, Massiello AL, et al. Development of a small implantable right ventricular assist device. ASAIO J 2005 51 : 730 5.
    • (2005) ASAIO J , vol.51 , pp. 730-735
    • Fukamachi, K.1    Horvath, D.J.2    Massiello, A.L.3
  • 3
    • 15444379022 scopus 로고    scopus 로고
    • Physiologic-insensitive left ventricular assist predisposes right-sided circulatory failure: A pilot simulation and validation study
    • Reesink K, Dekker A, van der Nagel T, et al. Physiologic-insensitive left ventricular assist predisposes right-sided circulatory failure: a pilot simulation and validation study. Artif Organs 2004 28 : 933 9.
    • (2004) Artif Organs , vol.28 , pp. 933-939
    • Reesink, K.1    Dekker, A.2    Van Der Nagel, T.3
  • 4
    • 0141702090 scopus 로고    scopus 로고
    • Biventricular support with the Jarvik 2000 axial flow pump: A feasibility study
    • Radovancevic B, Gregoric ID, Tamez D, et al. Biventricular support with the Jarvik 2000 axial flow pump: a feasibility study. ASAIO J 2003 49 : 604 7.
    • (2003) ASAIO J , vol.49 , pp. 604-607
    • Radovancevic, B.1    Gregoric, I.D.2    Tamez, D.3
  • 5
    • 4544361900 scopus 로고    scopus 로고
    • Biventricular support with the Jarvik 2000 ventricular assist device in a calf model of pulmonary hypertension
    • Kindo M, Radovancevic B, Gregoric ID, Conger JL, Kadipasaoglu K. Biventricular support with the Jarvik 2000 ventricular assist device in a calf model of pulmonary hypertension. ASAIO J 2004 50 : 444 50.
    • (2004) ASAIO J , vol.50 , pp. 444-450
    • Kindo, M.1    Radovancevic, B.2    Gregoric, I.D.3    Conger, J.L.4    Kadipasaoglu, K.5
  • 6
    • 0041807734 scopus 로고    scopus 로고
    • Biventricular support in patients with profound cardiogenic shock: A single center experience
    • Magliato KE, Kleisli T, Soukiasian HJ, et al. Biventricular support in patients with profound cardiogenic shock: a single center experience. ASAIO J 2003 49 : 475 9.
    • (2003) ASAIO J , vol.49 , pp. 475-479
    • Magliato, K.E.1    Kleisli, T.2    Soukiasian, H.J.3
  • 7
    • 27744465023 scopus 로고    scopus 로고
    • A complete mock circulation loop for the evaluation of left-, right-, and bi-ventricular assist devices
    • Timms DL, Hayne M, Galbraith A, McNeil K. A complete mock circulation loop for the evaluation of left-, right-, and bi-ventricular assist devices. Artif Organs 2005 29 : 564 71.
    • (2005) Artif Organs , vol.29 , pp. 564-571
    • Timms, D.L.1    Hayne, M.2    Galbraith, A.3    McNeil, K.4
  • 8
    • 33744967067 scopus 로고    scopus 로고
    • Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: A feasibility study
    • Frazier OH, Tuzun E, Cohn WE, Conger JL, Kadipasaoglu KA. Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: a feasibility study. ASAIO J 2006 52 : 145 9.
    • (2006) ASAIO J , vol.52 , pp. 145-149
    • Frazier, O.H.1    Tuzun, E.2    Cohn, W.E.3    Conger, J.L.4    Kadipasaoglu, K.A.5
  • 9
    • 0032865625 scopus 로고    scopus 로고
    • Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart
    • Wada H, Fukunaga S, Watari M, et al. Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart. Artif Organs 1999 23 : 741 6.
    • (1999) Artif Organs , vol.23 , pp. 741-746
    • Wada, H.1    Fukunaga, S.2    Watari, M.3
  • 10
    • 2342659640 scopus 로고    scopus 로고
    • Indirect bronchial shunt flow measurements in AbioCor implantable replacement heart recipients
    • Bhunia SK, Kung RTV. Indirect bronchial shunt flow measurements in AbioCor implantable replacement heart recipients. ASAIO J 2004 50 : 211 4.
    • (2004) ASAIO J , vol.50 , pp. 211-214
    • Bhunia, S.K.1    Kung, R.T.V.2
  • 11
    • 0036756730 scopus 로고    scopus 로고
    • A novel impeller TAH using magnetic bearings for load reduction
    • Qian KX, Ru WM, Zeng P, Yuan HY. A novel impeller TAH using magnetic bearings for load reduction. J Med Eng Technol 2002 26 : 214 6.
    • (2002) J Med Eng Technol , vol.26 , pp. 214-216
    • Qian, K.X.1    Ru, W.M.2    Zeng, P.3    Yuan, H.Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.