Design and construction of a mock human circulatory system
-
Sonesta Beach Resort, Florida
-
Patel S, Allaire PE, Wood HG, Adams JM, Olsen DB. Design and construction of a mock human circulatory system. Summer Bioengineering Conference, Sonesta Beach Resort, Florida.
-
Summer Bioengineering Conference
-
-
Patel, S.1
Allaire, P.E.2
Wood, H.G.3
Adams, J.M.4
Olsen, D.B.5
-
2
-
-
0036630618
-
Sensorless estimation of pressure head and flow of a continuous flow artificial heart based on input power and rotational speed
-
Yoshizawa M, Sato T, Tanaka A, et al. Sensorless estimation of pressure head and flow of a continuous flow artificial heart based on input power and rotational speed. ASAIO J 2002;48:443-8.
-
(2002)
ASAIO J
, vol.48
, pp. 443-448
-
-
Yoshizawa, M.1
Sato, T.2
Tanaka, A.3
-
3
-
-
0035168269
-
Design and evaluation of a single-pivot supported centrifugal blood pump
-
Yoshino M, Uemura M, Takahashi K, et al. Design and evaluation of a single-pivot supported centrifugal blood pump. Artif Organs 2001;25:683-7.
-
(2001)
Artif Organs
, vol.25
, pp. 683-687
-
-
Yoshino, M.1
Uemura, M.2
Takahashi, K.3
-
4
-
-
0028089088
-
Internal hydraulic loss in a seal-less centrifugal gyro pump
-
Makinouchi K, Ohara Y, Sakuma I, et al. Internal hydraulic loss in a seal-less centrifugal gyro pump. Artif Organs 1994;18:25-31.
-
(1994)
Artif Organs
, vol.18
, pp. 25-31
-
-
Makinouchi, K.1
Ohara, Y.2
Sakuma, I.3
-
5
-
-
70349334253
-
Standard practice for assessment of hemolysis in continuous flow blood pumps
-
ASTM_F1841-97. Standard practice for assessment of hemolysis in continuous flow blood pumps. ASTM 1998;13:1-5.
-
(1998)
ASTM
, vol.13
, pp. 1-5
-
-
-
6
-
-
0032446613
-
Long-term mechanical circulatory support system reliability recommendation
-
Pantalos G, Altieri F, Berson A. Long-term mechanical circulatory support system reliability recommendation. Ann Thorac Surg 1998;66:1852-9.
-
(1998)
Ann Thorac Surg
, vol.66
, pp. 1852-1859
-
-
Pantalos, G.1
Altieri, F.2
Berson, A.3
-
7
-
-
0033848745
-
Evaluation of cardiac function during left ventricular assist by a centrifugal blood pump
-
Kikugawa D. Evaluation of cardiac function during left ventricular assist by a centrifugal blood pump. Artif Organs 2000;24:632-5.
-
(2000)
Artif Organs
, vol.24
, pp. 632-635
-
-
Kikugawa, D.1
-
8
-
-
0030250453
-
Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings
-
Bearnson GB, Olsen DB, Khanwilkar PS, Long JW, Allaire PE, Maslen EH. Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings. ASAIO J 1996;42: M620-4.
-
(1996)
ASAIO J
, vol.42
-
-
Bearnson, G.B.1
Olsen, D.B.2
Khanwilkar, P.S.3
Long, J.W.4
Allaire, P.E.5
Maslen, E.H.6
-
9
-
-
0030795951
-
Control of centrifugal blood pump based on the motor current
-
Iijima T, Inamoto T, Nogawa M, Takatani S. Control of centrifugal blood pump based on the motor current. Artif Organs 1997;21:655-60.
-
(1997)
Artif Organs
, vol.21
, pp. 655-660
-
-
Iijima, T.1
Inamoto, T.2
Nogawa, M.3
Takatani, S.4
-
10
-
-
0002844887
-
Pulmonary hemodynamics
-
Bergel DH, ed. Oxford: Academic Press
-
Milnor W. Pulmonary hemodynamics. In: Bergel DH, ed. Cardiovascular Fluid Dynamics. Oxford: Academic Press, 1972;299-340.
-
(1972)
Cardiovascular Fluid Dynamics
, pp. 299-340
-
-
Milnor, W.1
-
12
-
-
0348230939
-
Characterization of an adult mock circulation for testing cardiac support devices
-
Pantalos G, Koenig S, Gillars K, Girdharan G, Ewert D. Characterization of an adult mock circulation for testing cardiac support devices. ASAIO J 2004;50:37-46.
-
(2004)
ASAIO J
, vol.50
, pp. 37-46
-
-
Pantalos, G.1
Koenig, S.2
Gillars, K.3
Girdharan, G.4
Ewert, D.5
-
13
-
-
15444369229
-
A bridge from short-term to long-term left ventricular assist device: Experimental verification of a physiological controller
-
Wu Y, Allaire P, Tao G, et al. A bridge from short-term to long-term left ventricular assist device: experimental verification of a physiological controller. Artif Organs 2004;28:927-32.
-
(2004)
Artif Organs
, vol.28
, pp. 927-932
-
-
Wu, Y.1
Allaire, P.2
Tao, G.3
-
14
-
-
0016617573
-
Design of a hydraulic analog of the circulatory system for evaluating artificial hearts
-
Donovan F. Design of a hydraulic analog of the circulatory system for evaluating artificial hearts. Artif Organs 1975;3:439-49.
-
(1975)
Artif Organs
, vol.3
, pp. 439-449
-
-
Donovan, F.1
-
15
-
-
0141590368
-
Hydrodynamic and static performance evaluation of the moving-actuator type biventricular assist device, anyheart
-
Chung J, Lee JJ, Choi J, Kim J, Min BG. Hydrodynamic and static performance evaluation of the moving-actuator type biventricular assist device, anyheart. ASAIO J 2003;49:599-603.
-
(2003)
ASAIO J
, vol.49
, pp. 599-603
-
-
Chung, J.1
Lee, J.J.2
Choi, J.3
Kim, J.4
Min, B.G.5
-
16
-
-
12244265469
-
Outflow control for avoiding atrial suction in a continuous flow total artificial heart
-
Olegario PS, Yoshizawa M, Tanaka A, et al. Outflow control for avoiding atrial suction in a continuous flow total artificial heart. Artif Organs 2003;27:92-8.
-
(2003)
Artif Organs
, vol.27
, pp. 92-98
-
-
Olegario, P.S.1
Yoshizawa, M.2
Tanaka, A.3
-
17
-
-
0036430025
-
Physiologic control algorithms for rotary blood pumps using pressure sensor input
-
Bullister E, Reich S, Sluetz J. Physiologic control algorithms for rotary blood pumps using pressure sensor input. Artif Organs 2002;26:931-8.
-
(2002)
Artif Organs
, vol.26
, pp. 931-938
-
-
Bullister, E.1
Reich, S.2
Sluetz, J.3
-
18
-
-
27744465023
-
Evaluation of left ventricular assist device performance and hydraulic force in a complete mock circulation loop
-
Timms DL, Tan ACC, Pearcy MJ, Hayne M. Evaluation of left ventricular assist device performance and hydraulic force in a complete mock circulation loop. Artif Organs 2005;29:564-71.
-
(2005)
Artif Organs
, vol.29
, pp. 564-571
-
-
Timms, D.L.1
Tan, A.C.C.2
Pearcy, M.J.3
Hayne, M.4
|