Volumn 204, Issue 16-17, 2010, Pages 2841-2845
|
Microstructure, mechanical properties, and blood compatibility of zirconium nitride deposited on nickel-titanium shape memory alloy
|
Author keywords
Blood compatibility; Mechanical properties; Microstructure; NiTi shape memory alloy; ZrN film
|
Indexed keywords
BIOMEDICAL IMPLANTS;
BLOOD COMPATIBILITY;
BLOOD PLATELETS;
COMPOSITE HARDNESS;
ELECTROPOLISHED;
FIBROUS STRUCTURES;
MAXIMUM VALUES;
MODULUS VALUES;
NICKEL-TITANIUM SHAPE MEMORY ALLOYS;
NITI SHAPE MEMORY ALLOYS;
SEM;
SURFACE WETTABILITY;
SURFACE-TREATED MATERIALS;
THROMBORESISTANCE;
ZIRCONIUM NITRIDE;
ZRN FILMS;
ALLOYS;
BLOOD;
BLOOD SUBSTITUTES;
CERIUM ALLOYS;
HARDNESS;
MICROSTRUCTURE;
NANOINDENTATION;
PHOTODEGRADATION;
SCANNING ELECTRON MICROSCOPY;
SHAPE MEMORY EFFECT;
SURFACE PROPERTIES;
TITANIUM;
TITANIUM ALLOYS;
TITANIUM NITRIDE;
X RAY DIFFRACTION;
X RAY DIFFRACTION ANALYSIS;
X RAY PHOTOELECTRON SPECTROSCOPY;
ZIRCONIUM;
MECHANICAL PROPERTIES;
|
EID: 77951291124
PISSN: 02578972
EISSN: None
Source Type: Journal
DOI: 10.1016/j.surfcoat.2010.02.067 Document Type: Article |
Times cited : (12)
|
References (16)
|