-
1
-
-
0000216169
-
Ueber eine neue Art von Strahlen: Vorläufige Mitteilung
-
Röntgen W C 1895 Ueber eine neue Art von Strahlen: vorläufige Mitteilung Sitzungsberichte Med. Phys. Ges. Wurtzburg 137 132-41
-
(1895)
Sitzungsberichte Med. Phys. Ges. Wurtzburg
, vol.137
, pp. 132-141
-
-
Röntgen, W.C.1
-
2
-
-
0025793151
-
Benign and malignant adrenal masses: CT distinction with attenuation coefficients, size, and observer analysis
-
Lee M J, Hahn P F, Papanicolaou N, Egglin T K, Saini P R, Mueller S and Simeone J F 1991 Benign and malignant adrenal masses: CT distinction with attenuation coefficients, size, and observer analysis Radiology 179 415-8
-
(1991)
Radiology
, vol.179
, pp. 415-418
-
-
Lee, M.J.1
Hahn, P.F.2
Papanicolaou, N.3
Egglin, T.K.4
Saini, P.R.5
Mueller, S.6
Simeone, J.F.7
-
4
-
-
0025262173
-
Selenomethionyl proteins produced for analysis by multiwavelength anomalous diffraction (MAD): A vehicle for direct determination of three dimensional structure
-
Hendrickson W A, Horton J R and LeMaster D M 1990 Selenomethionyl proteins produced for analysis by multiwavelength anomalous diffraction (MAD): a vehicle for direct determination of three-dimensional structure EMBO J 9 1665-72 (Pubitemid 20137025)
-
(1990)
EMBO Journal
, vol.9
, Issue.5
, pp. 1665-1672
-
-
Hendrickson, W.A.1
Horton, J.R.2
LeMaster, D.M.3
-
7
-
-
0000969755
-
Problems associated with the measurement of X-ray attenuation coefficients: I. Silicon. Report of the International Union of Crystallography X-ray Attenuation Project
-
Creagh D C and Hubbell J H 1987 Problems associated with the measurement of X-ray attenuation coefficients: I. Silicon. Report of the International Union of Crystallography X-ray Attenuation Project Acta. Cryst. A 43 102-12
-
(1987)
Acta. Cryst.
, vol.43
, pp. 102-112
-
-
Creagh, D.C.1
Hubbell, J.H.2
-
8
-
-
0042267342
-
X-ray mass attenuation coefficient of silicon: Theory versus experiment
-
Tran C Q, Chantler C T and Barnea Z 2003 X-ray mass attenuation coefficient of silicon: theory versus experiment Phys. Rev. Lett. 90 257401
-
(2003)
Phys. Rev. Lett.
, vol.90
, pp. 257401
-
-
Tran, C.Q.1
Chantler, C.T.2
Barnea, Z.3
-
9
-
-
0034215176
-
Theoretical form factor, attenuation, and scattering tabulation for Z = 1-92 from e = 1-10 eV to e = 0.4-1.0 MeV
-
Chantler C T 2000 Theoretical form factor, attenuation, and scattering tabulation for Z = 1-92 from E = 1-10 eV to E = 0.4-1.0 MeV J. Phys. Chem. Ref. Data 29 597
-
(2000)
J. Phys. Chem. Ref. Data
, vol.29
, pp. 597
-
-
Chantler, C.T.1
-
10
-
-
0003966102
-
XCOM: Photon cross sections database
-
Berger M J, Hubbell J H, Seltzer S M, Coursey J S and Zucker D S 1998 XCOM: photon cross sections database Database 1 1
-
(1998)
Database
, vol.1
, pp. 1
-
-
Berger, M.J.1
Hubbell, J.H.2
Seltzer, S.M.3
Coursey, J.S.4
Zucker, D.S.5
-
11
-
-
18744370342
-
-
Chantler C T, Olsen K, Dragoset R A, Chang J, Kishore A R, Kotochigova S A and Zucker D S 2005 X-Ray Form factor, attenuation and scattering tables (version 2.1) Technical Report National Institute of Standards and Technology, Gaithersburg, MD (also available at 'http://physics.nist.gov/ffast')
-
(2005)
Technical Report
-
-
Chantler, C.T.1
Olsen, K.2
Dragoset, R.A.3
Chang, J.4
Kishore, A.R.5
Kotochigova, S.A.6
Zucker, D.S.7
-
12
-
-
27944452166
-
X-ray absorption in atomic Cd in the K-edge region
-
DOI 10.1016/j.radphyschem.2005.09.001, PII S0969806X05002410
-
Kodre A, Padenik Gomilek J, Miheli A and Aron I 2006 X-ray absorption in atomic Cd in the K-edge region Radiat. Phys. Chem. 75 188-94 (Pubitemid 41680567)
-
(2006)
Radiation Physics and Chemistry
, vol.75
, Issue.2
, pp. 188-194
-
-
Kodre, A.1
Padeznik Gomilsek, J.2
Mihelic, A.3
Arcon, I.4
-
13
-
-
12344266607
-
Measurement of the x-ray mass attenuation coefficient of silver using the x-ray-extended range technique
-
DOI 10.1088/0953-4075/38/1/009
-
Tran C Q, Chantler C T, Barnea Z, de Jonge M D, Dhal B B, Chung C T Y, Paterson D and Wang J 2005 Measurement of the x-ray mass attenuation coefficient of silver using the x-ray-extended range technique J. Phys. B At. Mol. Phys. 38 89-107 (Pubitemid 40121783)
-
(2005)
Journal of Physics B: Atomic, Molecular and Optical Physics
, vol.38
, Issue.1
, pp. 89-107
-
-
Tran, C.Q.1
Chantler, C.T.2
Barnea, Z.3
De Jonge, M.D.4
Dhal, B.B.5
Chung, C.T.Y.6
Paterson, D.7
Wang, J.8
-
14
-
-
0035679458
-
Measurement of the x-ray mass attenuation coefficient of copper using 8.85-20 keV synchrotron radiation
-
062506
-
Chantler C T, Tran C Q, Barnea Z, Paterson D, Cookson D J and Balaic D X 2001 Measurement of the x-ray mass attenuation coefficient of copper using 8.85-20 keV synchrotron radiation. Phys. Rev. A 64 062506 (Pubitemid 34061525)
-
(2001)
Physical Review A. Atomic, Molecular, and Optical Physics
, vol.64
, Issue.6
-
-
Chantler, C.T.1
Tran, C.Q.2
Barnea, Z.3
Paterson, D.4
Cookson, D.J.5
Balaic, D.X.6
-
15
-
-
33847793474
-
Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form-factor of tin over the energy range of 29 keV-60 keV
-
de Jonge M D et al. 2007 Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form-factor of tin over the energy range of 29 keV-60 keV Phys. Rev. A 75 032702
-
(2007)
Phys. Rev.
, vol.75
, pp. 032702
-
-
De Jonge, M.D.1
-
16
-
-
76749156720
-
Measurement of the x-ray mass attenuation coefficients of gold in the 35 keV-50 keV energy range
-
Islam M T, Rae N A, Glover J L, Barnea Z, de Jonge M D, Tran C Q, Wang J and Chantler C T 2010 Measurement of the x-ray mass attenuation coefficients of gold in the 35 keV-50 keV energy range Phys. Rev. A 81 022903
-
(2010)
Phys. Rev.
, vol.81
, pp. 022903
-
-
Islam, M.T.1
Rae, N.A.2
Glover, J.L.3
Barnea, Z.4
De Jonge, M.D.5
Tran, C.Q.6
Wang, J.7
Chantler, C.T.8
-
18
-
-
36149022530
-
Measurement of total attenuation cross sections in aluminum and gold for 14.4-keV gamma rays
-
Alonso J and Grodzins L 1965 Measurement of total attenuation cross sections in aluminum and gold for 14.4-keV gamma rays Phys. Rev. 137 975-8
-
(1965)
Phys. Rev.
, vol.137
, Issue.A
, pp. 975-978
-
-
Alonso, J.1
Grodzins, L.2
-
19
-
-
0002215719
-
-
Hubbell J H 1995 Bibliography of photon total cross section (attenuation coefficient) measurements Technical Report Ionizing Radiation Division, National Institute of Standards and Technology, Gaithersburg, MD, USA (http://physics.nist.gov/PhysRefData/photoncs/html/attencoef.html)
-
(1995)
Technical Report
-
-
Hubbell, J.H.1
-
20
-
-
36149027627
-
The absorption of X-rays from λ =.08 to 4.0 A
-
Allen S J M 1926 The absorption of X-rays from λ =.08 to 4.0 A Phys. Rev. 28 907-22
-
(1926)
Phys. Rev.
, vol.28
, pp. 907-922
-
-
Allen, S.J.M.1
-
21
-
-
84981784232
-
Die Massenschwächungs-, Photoabsorptions-und Streukoeffizienten monochromatischer Röntgenstrahlen von Ni (28), Cu (29), Ag (47), Cd (48), Sn (50), Ta (73), W (74), Ir (77), Pt (78), Au (79) und Pb (82)
-
Laubert S 1941 Die Massenschwächungs-, Photoabsorptions-und Streukoeffizienten monochromatischer Röntgenstrahlen von Ni (28), Cu (29), Ag (47), Cd (48), Sn (50), Ta (73), W (74), Ir (77), Pt (78), Au (79) und Pb (82) Ann. Phys., Lpz. 432 553-78
-
(1941)
Ann. Phys., Lpz.
, vol.432
, pp. 553-578
-
-
Laubert, S.1
-
22
-
-
3943056256
-
X-ray photoeffect cross sections in low-and medium-z absorbers for the energy range 852 eV to 40 keV
-
Bearden A J 1966 X-ray photoeffect cross sections in low-and medium-z absorbers for the energy range 852 eV to 40 keV J. Appl. Phys. 37 1681
-
(1966)
J. Appl. Phys.
, vol.37
, pp. 1681
-
-
Bearden, A.J.1
-
23
-
-
0004440521
-
Attenuation-coefficient measurements for 3.3- to 165.8-keV photons: Analysis in terms of total photoelectric cross sections
-
Parthasaradhi K and Hansen H H 1974 Attenuation-coefficient measurements for 3.3- to 165.8-keV photons: analysis in terms of total photoelectric cross sections Phys. Rev. A 10 563-568
-
(1974)
Phys. Rev.
, vol.10
, pp. 563-568
-
-
Parthasaradhi, K.1
Hansen, H.H.2
-
24
-
-
0016026642
-
Measurement of totally depleted silicon solid state detector thickness by x-ray attenuation
-
Hanser Frederick A and Sellers Bach 1974 Measurement of totally depleted silicon solid state detector thickness by x-ray attenuation Rev. Sci. Instrum. 45 226-31
-
(1974)
Rev. Sci. Instrum.
, vol.45
, pp. 226-231
-
-
Hanser Frederick, A.1
Bach, S.2
-
25
-
-
51249182744
-
Photoelectric cross-sections of low-energy photons
-
Rao V V and Shahnawaz 1978 Photoelectric cross-sections of low-energy photons Il Nuovo Cimento A 44 181
-
(1978)
Il Nuovo Cimento
, vol.44
, pp. 181
-
-
Rao, V.V.1
Shahnawaz2
-
26
-
-
0022892179
-
Measured 1 to 40 keV photoabsorption cross sections for: Fe, Ni, Sn, Ta, Pt, Au, Pb, U
-
Del Grande N K 1986 Measured 1 to 40 keV photoabsorption cross sections for: Fe, Ni, Sn, Ta, Pt, Au, Pb, U Proc. SPIE 691 2-9
-
(1986)
Proc. SPIE
, vol.691
, pp. 2-9
-
-
Del Grande, N.K.1
-
27
-
-
77951068142
-
Problems associated with the measurement of X-ray attenuation coefficients: II. Carbon. Report on the international union of crystallography x-ray attenuation project
-
Creagh D C and Hubbell J H 1990 Problems associated with the measurement of X-ray attenuation coefficients: II. Carbon. Report on the international union of crystallography x-ray attenuation project Acta Cryst. A 108 7673
-
(1990)
Acta Cryst.
, vol.108
, pp. 7673
-
-
Creagh, D.C.1
Hubbell, J.H.2
-
28
-
-
18444373555
-
Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of molybdenum over the 13.5-41.5-keV energy range
-
DOI 10.1103/PhysRevA.71.032702, 032702
-
de Jonge M D, Tran C Q, Chantler C T, Barnea Z, Dhal B B, Cookson D J, Lee W-K and Mashayekhi A 2005 Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of molybdenum over the 13.5-41.5-keV energy range Phys. Rev. A 71 032702 (Pubitemid 40648475)
-
(2005)
Physical Review A - Atomic, Molecular, and Optical Physics
, vol.71
, Issue.3
, pp. 1-16
-
-
De Jonge, M.D.1
Tran, C.Q.2
Chantler, C.T.3
Barnea, Z.4
Dhal, B.B.5
Cookson, D.J.6
Lee, W.-K.7
Mashayekhi, A.8
-
29
-
-
0037251926
-
Quantitative determination of major systematics in synchrotron x-ray experiments: Seeing through harmonic components
-
Tran C Q, Barnea Z, de Jonge M D, Dhal B B, Paterson D, Cookson D J and Chantler C T 2003 Quantitative determination of major systematics in synchrotron x-ray experiments: seeing through harmonic components X-Ray Spectrom. 32 69-74 (Pubitemid 36166257)
-
(2003)
X RAY SPECTROMETRY
, vol.32
, Issue.1
, pp. 69-74
-
-
Tran, C.Q.1
Barnea, Z.2
De Jonge, M.D.3
Dhal, B.B.4
Paterson, D.5
Cookson, D.J.6
Chantler, C.T.7
-
30
-
-
1942475756
-
X-ray bandwidth: Determination by on-edge absorption and effect on various absorption experiments
-
de Jonge M D, Barnea Z, Tran C Q and Chantler C T 2004 X-ray bandwidth: Determination by on-edge absorption and effect on various absorption experiments Phys. Rev. A 69 022717
-
(2004)
Phys. Rev.
, vol.69
, pp. 022717
-
-
De Jonge, M.D.1
Barnea, Z.2
Tran, C.Q.3
Chantler, C.T.4
-
31
-
-
4043100595
-
Full-foil x-ray mapping of integrated column density applied to the absolute determination of mass attenuation coefficients
-
DOI 10.1088/0957-0233/15/9/019, PII S0957023304786440
-
Tran C Q, de Jonge M D, Barnea Z and Chantler C T 2004 Absolute determination of the effect of scattering and fluorescence on x-ray attenuation measurements J. Phys. B: At. Mol. Opt. Phys. 37 3163-76 (Pubitemid 39443972)
-
(2004)
Measurement Science and Technology
, vol.15
, Issue.9
, pp. 1811-1822
-
-
De Jonge, M.D.1
Barnea, Z.2
Tran, C.Q.3
Chantler, C.T.4
-
32
-
-
60649103750
-
Nano-roughness in gold revealed from x-ray signature
-
Glover J L, Chantler C T and de Jonge M D 2009 Nano-roughness in gold revealed from x-ray signature Phys. Lett. A 373 1177-80
-
(2009)
Phys. Lett.
, vol.373
, pp. 1177-1180
-
-
Glover, J.L.1
Chantler, C.T.2
De Jonge, M.D.3
-
33
-
-
56349170446
-
Measurements of the x-ray mass-attenuation coefficient and imaginary component of the form factor of copper
-
Glover J L, Chantler C T, Barnea Z, Rae N A, Tran C Q, Creagh D C, Paterson D and Dhal B B 2008 Measurements of the x-ray mass-attenuation coefficient and imaginary component of the form factor of copper Phys. Rev. A 78 032702
-
(2008)
Phys. Rev.
, vol.78
, pp. 052902
-
-
Glover, J.L.1
Chantler, C.T.2
Barnea, Z.3
Rae, N.A.4
Tran, C.Q.5
Creagh, D.C.6
Paterson, D.7
Dhal, B.B.8
-
34
-
-
77951074418
-
-
de Jonge M D 2005 High accuracy measurements of the x-ray mass attenuation coefficients of molybdenum and tin: testing theories of photoabsorption PhD Thesis University of Melbourne (available from http://eprints.infodiv.unimelb.edu.au/archive/00002201/)
-
(2005)
PhD Thesis
-
-
De Jonge, M.D.1
-
35
-
-
0002178954
-
The statistical error in x-ray absorption measurements
-
Nordfors B 1960 The statistical error in x-ray absorption measurements Arkiv Fysik 18 37
-
(1960)
Arkiv Fysik
, vol.18
, pp. 37
-
-
Nordfors, B.1
-
38
-
-
33750185312
-
Accurate determination of X-ray energies using powder diffraction
-
DOI 10.1016/j.radphyschem.2005.09.018, PII S0969806X06003136
-
Rae N A, Chantler C T, Tran C Q and Barnea Z 2006 Accurate determination of X-ray energies using powder diffraction Radiat. Phys. Chem. 75 2063-6 (Pubitemid 44602540)
-
(2006)
Radiation Physics and Chemistry
, vol.75
, Issue.SPEC. ISS.
, pp. 2063-2066
-
-
Rae, N.A.1
Chantler, C.T.2
Tran, C.Q.3
Barnea, Z.4
-
39
-
-
4043100595
-
Full-foil x-ray mapping of integrated column density applied to the absolute determination of mass attenuation coefficients
-
DOI 10.1088/0957-0233/15/9/019, PII S0957023304786440
-
de Jonge M D, Barnea Z, Tran C Q and Chantler C T 2004 Full-foil x-ray mapping of integrated column density applied to the absolute determination of mass attenuation coefficients Meas. Sci. Technol. 15 1811-22 (Pubitemid 39443972)
-
(2004)
Measurement Science and Technology
, vol.15
, Issue.9
, pp. 1811-1822
-
-
De Jonge, M.D.1
Barnea, Z.2
Tran, C.Q.3
Chantler, C.T.4
-
40
-
-
0345531760
-
Detection of the contribution of harmonics to the diffracted x-ray intensity
-
Barnea Z and Mohyla J 1974 Detection of the contribution of harmonics to the diffracted x-ray intensity J. Appl. Cryst. 7 298-9
-
(1974)
J. Appl. Cryst.
, vol.7
, pp. 298-299
-
-
Barnea, Z.1
Mohyla, J.2
-
41
-
-
77951026046
-
A method to determine the absolute harmonic content of an X-ray beam using attenuation measurements
-
Glover J L and Chantler C T 2009 A method to determine the absolute harmonic content of an X-ray beam using attenuation measurements X-Ray Spectrom. 38 510-12
-
(2009)
X-Ray Spectrom.
, vol.38
, pp. 510-512
-
-
Glover, J.L.1
Chantler, C.T.2
-
42
-
-
0003894270
-
-
Thompson A C and Vaughan D 2001 and Center for X-ray optics and Advanced Light Source X-Ray Data Booklet (Lawrence Berkeley National Laboratory, University of California)
-
(2001)
X-Ray Data Booklet
-
-
Thompson, A.C.1
Vaughan, D.2
-
43
-
-
0034341602
-
CODATA recommended values of the fundamental physical constants: 1998
-
Mohr P J and Taylor B N 2000 CODATA recommended values of the fundamental physical constants: 1998 Rev. Mod. Phys. 72 351-495
-
(2000)
Rev. Mod. Phys.
, vol.72
, pp. 351-495
-
-
Mohr, P.J.1
Taylor, B.N.2
-
44
-
-
0035476814
-
3 by EXAFS under in situ laser irradiation
-
DOI 10.1016/S0038-1098(01)00354-4, PII S0038109801003544
-
3 by EXAFS under in situ laser irradiation Solid State Commun. 120 149-53 (Pubitemid 32935053)
-
(2001)
Solid State Communications
, vol.120
, Issue.4
, pp. 149-153
-
-
Chen, G.1
Jain, H.2
Khalid, S.3
Li, J.4
Drabold, D.A.5
Elliott, S.R.6
-
45
-
-
0000269670
-
Spin-dependent extended x-ray absorption fine structure in magnetic oxides
-
Ahlers D, Attenkofer K and Schutz G 1998 Spin-dependent extended x-ray absorption fine structure in magnetic oxides J. Appl. Phys. 83 7085
-
(1998)
J. Appl. Phys.
, vol.83
, pp. 7085
-
-
Ahlers, D.1
Attenkofer, K.2
Schutz, G.3
-
46
-
-
11644251454
-
3,2 edges of 3d elements
-
PII S0953898498864564
-
Lemke L et al. 1998 Magnetic extended x-ray absorption fine structure at the L 3.2 edges of 3d elements J. Phys.: Condens. Matter 10 1917-30 (Pubitemid 128586806)
-
(1998)
Journal of Physics Condensed Matter
, vol.10
, Issue.8
, pp. 1917-1930
-
-
Lemke, L.1
Wende, H.2
Srivastava, P.3
Chauvistre, R.4
Haack, N.5
Baberschke, K.6
Hunter-Dunn, J.7
Arvanitis, D.8
Martensson, N.9
Ankudinov, A.10
Rehr, J.J.11
-
47
-
-
0036503339
-
2,3 edge magnetic circular dichroism study of 5d moment formation in ferromagnetic Ir-Fe alloys
-
DOI 10.1016/S0921-4526(01)01540-X, PII S092145260101540X
-
Krishnamurthy V V, Suzuki M, Kawamura N, Ishikawa T and Kohori Y 2002 Iridium L2, 3 edge magnetic circular dichroism study of 5d moment formation in ferromagnetic Ir-Fe alloys Phys. B: Phys. Condens. Matter 312 647-9 (Pubitemid 34434551)
-
(2002)
Physica B: Condensed Matter
, vol.312-313
, pp. 647-649
-
-
Krishnamurthy, V.V.1
Suzuki, M.2
Kawamura, N.3
Ishikawa, T.4
Kohori, Y.5
-
48
-
-
0035868722
-
Structure and bonding of gold metal clusters, colloids, and nanowires studied by EXAFS, XANES, and WAXS
-
Benfield R E, Grandjean D, Kroll M, Pugin R, Sawitowski T and Schmid G 2001 Structure and bonding of gold metal clusters, colloids, and nanowires studied by EXAFS, XANES, and WAXS J. Phys. Chem. B 105 1961-70 (Pubitemid 33764219)
-
(2001)
Journal of Physical Chemistry B
, vol.105
, Issue.10
, pp. 1961-1970
-
-
Benfield, R.E.1
Grandjean, D.2
Kroll, M.3
Pugin, R.4
Sawitowski, T.5
Schmid, G.6
-
49
-
-
0001435454
-
X-ray-absorption fine-structure standards: A comparison of experiment and theory
-
Li G G, Bridges F and Booth C H 1995 X-ray-absorption fine-structure standards: A comparison of experiment and theory Phys. Rev. B 52 6332-48
-
(1995)
Phys. Rev.
, vol.52
, pp. 6332-6348
-
-
Li, G.G.1
Bridges, F.2
Booth, C.H.3
-
50
-
-
33750160442
-
-
Smale L F, Chantler C T, de Jonge M D, Barnea Z and Tran C Q 2006 Rad. Phys. Chem. 75 1559-63
-
(2006)
Rad. Phys. Chem.
, vol.75
, pp. 1559-1563
-
-
Smale, L.F.1
Chantler, C.T.2
De Jonge, M.D.3
Barnea, Z.4
Tran, C.Q.5
-
51
-
-
0031122709
-
XAFS measurements of Rb-O bonds in ambient and supercritical water
-
Newville M, Fulton J L, Pfund D M, Wallen S L, Stern E A and Ma Y 1997 XAFS measurements of Rb-O bonds in ambient and supercritical water J. Phys. IV France 7 C2-1007 (Pubitemid 127817957)
-
(1997)
Journal De Physique. IV : JP
, vol.7
, Issue.PART 2
-
-
Newville, M.1
Fulton, J.L.2
Pfund, D.M.3
Wallen, S.L.4
Stern, E.A.5
Ma, Y.6
-
54
-
-
0031494845
-
EXAFS debye-waller factor and thermal vibrations of crystals
-
DOI 10.1107/S0909049597006900
-
Dalba G and Fornasini P 1997 EXAFS Debye-Waller factor and thermal vibrations of crystals J. Synchrotron Radiat. 4 243-55 (Pubitemid 127091829)
-
(1997)
Journal of Synchrotron Radiation
, vol.4
, Issue.4
, pp. 243-255
-
-
Dalba, G.1
Fornasini, P.2
-
56
-
-
0023966097
-
High-temperature thermal expansion of six metallic elements measured by dilatation method and X-ray diffraction
-
Suh I K, Ohta H and Waseda Y 1988 High-temperature thermal expansion of six metallic elements measured by dilatation method and X-ray diffraction J. Mater. Sci. 23 757-60 (Pubitemid 18592717)
-
(1988)
Journal of Materials Science
, vol.23
, Issue.2
, pp. 757-760
-
-
Suh In-Kook1
Ohta, H.2
Waseda, Y.3
-
57
-
-
7444240471
-
Accurate determination of the thickness or mass per unit area of thin foils and single-crystal wafers for x-ray attenuation measurements
-
Tran C Q, Chantler C T, Barnea Z and de Jonge M D 2004 Accurate determination of the thickness or mass per unit area of thin foils and single-crystal wafers for x-ray attenuation measurements Rev. Sci. Instrum. 75 2943-9
-
(2004)
Rev. Sci. Instrum.
, vol.75
, pp. 2943-2949
-
-
Tran, C.Q.1
Chantler, C.T.2
Barnea, Z.3
De Jonge, M.D.4
|