메뉴 건너뛰기




Volumn 87, Issue 6, 2010, Pages 2087-2094

Virtual models of indoor-air-quality sensors

Author keywords

Air conditioning systems; Data mining; Heating; Indoor air quality; Neural networks; Sensor modeling; Sensor monitoring; Statistical control charts; Ventilation

Indexed keywords

AIR CONDITIONING; AIR QUALITY; CARBON DIOXIDE; CLIMATE CONTROL; HEATING; INDOOR AIR POLLUTION; NEURAL NETWORKS; VENTILATION;

EID: 77950951852     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2009.12.008     Document Type: Article
Times cited : (30)

References (35)
  • 1
    • 31144462109 scopus 로고    scopus 로고
    • Dynamic simulation of energy management control functions for HVAC systems in buildings
    • Huang W., Zaheeruddin M., and Cho S.H. Dynamic simulation of energy management control functions for HVAC systems in buildings. Energy Convers Manage 47 7-8 (2006) 926-943
    • (2006) Energy Convers Manage , vol.47 , Issue.7-8 , pp. 926-943
    • Huang, W.1    Zaheeruddin, M.2    Cho, S.H.3
  • 2
    • 84881375444 scopus 로고    scopus 로고
    • ; 2008 [Accessed 19.09.08.
    • ; 2008 [Accessed 19.09.08).
  • 3
    • 0035480209 scopus 로고    scopus 로고
    • HVAC control strategies to enhance comfort and minimize energy usage
    • Mathews E.H., Botha C.P., Arndt D.C., and Malan A. HVAC control strategies to enhance comfort and minimize energy usage. Energy Build 33 8 (2001) 853-863
    • (2001) Energy Build , vol.33 , Issue.8 , pp. 853-863
    • Mathews, E.H.1    Botha, C.P.2    Arndt, D.C.3    Malan, A.4
  • 4
    • 77950934926 scopus 로고    scopus 로고
    • A case study for influence of building thermal insulation on cooling load and air-conditioning system in the hot and humid regions
    • Aktacir M.A., Büyükalaca O., and Yilmaz T. A case study for influence of building thermal insulation on cooling load and air-conditioning system in the hot and humid regions. Appl Energy 87 2 (2010) 599-607
    • (2010) Appl Energy , vol.87 , Issue.2 , pp. 599-607
    • Aktacir, M.A.1    Büyükalaca, O.2    Yilmaz, T.3
  • 5
    • 77950928743 scopus 로고    scopus 로고
    • Thermal performance evaluation of a low-cost housing prototype made with plywood panels in Southern Brazil
    • Krüger E.L., and Laroca C. Thermal performance evaluation of a low-cost housing prototype made with plywood panels in Southern Brazil. Appl Energy 87 2 (2010) 661-672
    • (2010) Appl Energy , vol.87 , Issue.2 , pp. 661-672
    • Krüger, E.L.1    Laroca, C.2
  • 6
    • 58949104767 scopus 로고    scopus 로고
    • Thermal comfort in residential buildings: comfort values and scales for building energy simulation
    • Peeters L., de Dear R., Hensen J., and D'haeseleer W. Thermal comfort in residential buildings: comfort values and scales for building energy simulation. Appl Energy 86 5 (2009) 772-780
    • (2009) Appl Energy , vol.86 , Issue.5 , pp. 772-780
    • Peeters, L.1    de Dear, R.2    Hensen, J.3    D'haeseleer, W.4
  • 7
    • 49849101532 scopus 로고    scopus 로고
    • Development of a method for calculating steady-state equipment sensible heat ratio of direct expansion air conditioning units
    • Liang X., Chan M.Y., and Deng S. Development of a method for calculating steady-state equipment sensible heat ratio of direct expansion air conditioning units. Appl Energy 85 12 (2008) 1198-1207
    • (2008) Appl Energy , vol.85 , Issue.12 , pp. 1198-1207
    • Liang, X.1    Chan, M.Y.2    Deng, S.3
  • 8
    • 41549156589 scopus 로고    scopus 로고
    • A transient ventilation demand model for air-conditioned offices
    • Wong L.T., and Mui K.W. A transient ventilation demand model for air-conditioned offices. Appl Energy 85 7 (2008) 545-554
    • (2008) Appl Energy , vol.85 , Issue.7 , pp. 545-554
    • Wong, L.T.1    Mui, K.W.2
  • 9
    • 33749236977 scopus 로고    scopus 로고
    • An energy benchmarking model for ventilation systems of air-conditioned offices in subtropical climates
    • Mui K.W., Wong L.T., and Law L.Y. An energy benchmarking model for ventilation systems of air-conditioned offices in subtropical climates. Appl Energy 84 1 (2007) 89-98
    • (2007) Appl Energy , vol.84 , Issue.1 , pp. 89-98
    • Mui, K.W.1    Wong, L.T.2    Law, L.Y.3
  • 10
    • 34547450758 scopus 로고    scopus 로고
    • Data-driven modeling, fault diagnosis and optimal sensor selection for HVAC chillers
    • Namburu S.M., Azam M.S., Luo J., Choi K., and Pattipati K.R. Data-driven modeling, fault diagnosis and optimal sensor selection for HVAC chillers. IEEE Trans Automat Sci Eng 4 3 (2007) 469-473
    • (2007) IEEE Trans Automat Sci Eng , vol.4 , Issue.3 , pp. 469-473
    • Namburu, S.M.1    Azam, M.S.2    Luo, J.3    Choi, K.4    Pattipati, K.R.5
  • 11
    • 18444408086 scopus 로고    scopus 로고
    • Multi-fault detection and diagnosis of HVAC systems: an experimental study
    • Cho S., Hong Y., Kim W., and Zaheeruddin M. Multi-fault detection and diagnosis of HVAC systems: an experimental study. Int J Energy Res 29 6 (2005) 471-483
    • (2005) Int J Energy Res , vol.29 , Issue.6 , pp. 471-483
    • Cho, S.1    Hong, Y.2    Kim, W.3    Zaheeruddin, M.4
  • 12
    • 0033733620 scopus 로고    scopus 로고
    • Performance validation and energy analysis of HVAC systems using simulation
    • Salsbury T., and Diamond R. Performance validation and energy analysis of HVAC systems using simulation. Energy Build 32 1 (2000) 5-17
    • (2000) Energy Build , vol.32 , Issue.1 , pp. 5-17
    • Salsbury, T.1    Diamond, R.2
  • 13
    • 33646411785 scopus 로고    scopus 로고
    • Data mining based sensor fault diagnosis and validation for building air conditioning system
    • Hou Z., Lian Z., Yao Y., and Yuan X. Data mining based sensor fault diagnosis and validation for building air conditioning system. Energy Convers Manage 47 15-16 (2006) 2479-2490
    • (2006) Energy Convers Manage , vol.47 , Issue.15-16 , pp. 2479-2490
    • Hou, Z.1    Lian, Z.2    Yao, Y.3    Yuan, X.4
  • 14
    • 33748442297 scopus 로고    scopus 로고
    • A rule-based fault detection method for air handling units
    • Schein J., Bushby S.T., Castro N.S., and House J.M. A rule-based fault detection method for air handling units. Energy Build 38 12 (2006) 1485-1492
    • (2006) Energy Build , vol.38 , Issue.12 , pp. 1485-1492
    • Schein, J.1    Bushby, S.T.2    Castro, N.S.3    House, J.M.4
  • 15
    • 8344246718 scopus 로고    scopus 로고
    • Using control charts to monitor process and product quality profile
    • Woodall W.H., Spitzner D.J., Montgomery D.C., and Gupta S. Using control charts to monitor process and product quality profile. J Qual Technol 36 3 (2004) 309-320
    • (2004) J Qual Technol , vol.36 , Issue.3 , pp. 309-320
    • Woodall, W.H.1    Spitzner, D.J.2    Montgomery, D.C.3    Gupta, S.4
  • 18
    • 1642541495 scopus 로고    scopus 로고
    • On-line monitoring when the process yields a linear profile
    • Kang L., and Albin S.L. On-line monitoring when the process yields a linear profile. J Qual Technol 32 4 (2000) 418-426
    • (2000) J Qual Technol , vol.32 , Issue.4 , pp. 418-426
    • Kang, L.1    Albin, S.L.2
  • 19
    • 0345064229 scopus 로고
    • Multivariate control chart: control charts for calibration curves
    • Mestek O., Pavlik J., and Suchanek M. Multivariate control chart: control charts for calibration curves. J Anal Chem 350 6 (1994) 344-351
    • (1994) J Anal Chem , vol.350 , Issue.6 , pp. 344-351
    • Mestek, O.1    Pavlik, J.2    Suchanek, M.3
  • 21
    • 33746854229 scopus 로고    scopus 로고
    • Manufacturing and service applications
    • Kusiak A., and Mining Data. Manufacturing and service applications. Int J Prod Res 44 18-19 (2006) 4175-4191
    • (2006) Int J Prod Res , vol.44 , Issue.18-19 , pp. 4175-4191
    • Kusiak, A.1    Mining, Data.2
  • 25
    • 34447645110 scopus 로고    scopus 로고
    • Multilayer perceptron tumor diagnosis based on chromatography analysis of urinary nucleoside
    • Seidel P., Seidel A., and Herbarth O. Multilayer perceptron tumor diagnosis based on chromatography analysis of urinary nucleoside. Neural Networks 20 5 (2007) 646-651
    • (2007) Neural Networks , vol.20 , Issue.5 , pp. 646-651
    • Seidel, P.1    Seidel, A.2    Herbarth, O.3
  • 26
    • 33747401950 scopus 로고    scopus 로고
    • Combustion efficiency optimization and virtual testing: a data-mining approach
    • Kusiak A., and Song Z. Combustion efficiency optimization and virtual testing: a data-mining approach. IEEE Trans Indus Informat 2 3 (2006) 176-184
    • (2006) IEEE Trans Indus Informat , vol.2 , Issue.3 , pp. 176-184
    • Kusiak, A.1    Song, Z.2
  • 27
    • 54149110093 scopus 로고    scopus 로고
    • Models for monitoring of wind farm power
    • Kusiak A., Zheng H.Y., and Song Z. Models for monitoring of wind farm power. Renewable Energy 34 3 (2009) 583-590
    • (2009) Renewable Energy , vol.34 , Issue.3 , pp. 583-590
    • Kusiak, A.1    Zheng, H.Y.2    Song, Z.3
  • 28
    • 71849087182 scopus 로고    scopus 로고
    • Cooling output optimization of an air handling unit
    • Kusiak A., and Li M.-Y. Cooling output optimization of an air handling unit. Appl Energy 87 3 (2010) 901-909
    • (2010) Appl Energy , vol.87 , Issue.3 , pp. 901-909
    • Kusiak, A.1    Li, M.-Y.2
  • 29
    • 63449107930 scopus 로고    scopus 로고
    • Fault diagnosis for temperature, flow rate and pressure sensors in VAV systems using wavelet neural network
    • Du Z., Jin X., and Yang Y. Fault diagnosis for temperature, flow rate and pressure sensors in VAV systems using wavelet neural network. Appl Energy 86 9 (2009) 1624-1631
    • (2009) Appl Energy , vol.86 , Issue.9 , pp. 1624-1631
    • Du, Z.1    Jin, X.2    Yang, Y.3
  • 33
    • 4043137356 scopus 로고    scopus 로고
    • A tutorial on support vector regression
    • Smola A.J., and Schoelkopf B. A tutorial on support vector regression. Stat Comput 14 3 (2004) 199-222
    • (2004) Stat Comput , vol.14 , Issue.3 , pp. 199-222
    • Smola, A.J.1    Schoelkopf, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.